Juhyoun Kwak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Juhyoun Kwak has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Jun Hui Park
Department of Chemistry Education and Institute of Fusion Science, Chonbuk National University , Jeonju 54896, Korea
2 shared publications- Haesik Yang
Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, Korea
1 shared publication Hochun Lee
Department of Chemistry, Korea Advanced Institute of Science and Technology (KAIST), 373-1 Kusong-dong Yusong-gu, 373-1 Kusong-dong yusong-gu, Taejon 305-701, Republic of Korea
1 shared publicationNian Bing Li
Department of Chemistry, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Korea
1 shared publication- Seongpil Hwang
Myongji Univ, Dept Chem, Yongin 449728, South Korea
1 shared publication - Seongpil Hwang
Department of Advanced Materials Chemistry, Korea University, Sejong 30019, Korea
1 shared publication
Latest Publications
- 8 June 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (24) , 20955-20962
Programmable Electrochemical Rectifier Based on a Thin-Layer Cell
A programmable electrochemical rectifier based on thin-layer electrochemistry is described here. Both the rectification ratio and the response time of the device are programmable by controlling the gap distance of the thin-layer electrochemical cell, which is easily controlled using commercially available beads. One of the electrodes was modified using a ferrocene-terminated self-assembled monolayer to offer unidirectional charge transfers via soluble redox species. The thin-layer configuration provided enhanced mass transport, which was determined by the gap thickness. The device with the smallest gap thickness (∼4 μm) showed an unprecedented, high rectification ratio (up to 160) with a fast response time in a two-terminal configuration using conventional electronics.
- 8 June 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (24) , 20955-20962
Programmable Electrochemical Rectifier Based on a Thin-Layer Cell
A programmable electrochemical rectifier based on thin-layer electrochemistry is described here. Both the rectification ratio and the response time of the device are programmable by controlling the gap distance of the thin-layer electrochemical cell, which is easily controlled using commercially available beads. One of the electrodes was modified using a ferrocene-terminated self-assembled monolayer to offer unidirectional charge transfers via soluble redox species. The thin-layer configuration provided enhanced mass transport, which was determined by the gap thickness. The device with the smallest gap thickness (∼4 μm) showed an unprecedented, high rectification ratio (up to 160) with a fast response time in a two-terminal configuration using conventional electronics.
- 2 June 2011
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 27 (13) , 8548-8553
Ordered Polymeric Microhole Array Made by Selective Wetting and Applications for Electrochemical Microelectrode Array
In this paper, we report the microelectrode array fabrication using selective wetting/dewetting of polymers on a chemical pattern which is a simple and convenient method capable of creating negative polymeric replicas using polyethylene glycol (PEG) as a clean and nontoxic sacrificial layer. The fabricated hole-patterned polypropylene film on gold demonstrated enhanced electrochemical properties. The chemical pattern is fabricated by microcontact printing using octadecanethiol (ODT) as an ink on gold substrate. When PEG is spin-cast on the chemical pattern, PEG solution selectively dewets the ODT patterned areas and wets the remaining bare gold areas, leading to the formation of arrayed PEG dots. A negative replicas of the PEG dot array is obtained by spin-coating of polypropylene (PP) solution in hexane which preferentially interacts with the hydrophobic ODT region on the patterned gold surface. The arrayed PEG dots are not affected the during PP spin-coating step because of their intrinsic immiscibility. Consequently, the hole-patterned PP film is obtained after PEG removal. The electrochemical signal of the PP film demonstrates the negligible leakage current by high dielectric and self-healing of defects on the chemical pattern by the polymer. This method is applicable to fabrication of microelectrode arrays and possibly can be employed to fabricate a variety of functional polymeric structures, such as photomasks, arrays of biomolecules, cell arrays, and arrays of nanomaterials.
- 2 June 2011
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 27 (13) , 8548-8553
Ordered Polymeric Microhole Array Made by Selective Wetting and Applications for Electrochemical Microelectrode Array
In this paper, we report the microelectrode array fabrication using selective wetting/dewetting of polymers on a chemical pattern which is a simple and convenient method capable of creating negative polymeric replicas using polyethylene glycol (PEG) as a clean and nontoxic sacrificial layer. The fabricated hole-patterned polypropylene film on gold demonstrated enhanced electrochemical properties. The chemical pattern is fabricated by microcontact printing using octadecanethiol (ODT) as an ink on gold substrate. When PEG is spin-cast on the chemical pattern, PEG solution selectively dewets the ODT patterned areas and wets the remaining bare gold areas, leading to the formation of arrayed PEG dots. A negative replicas of the PEG dot array is obtained by spin-coating of polypropylene (PP) solution in hexane which preferentially interacts with the hydrophobic ODT region on the patterned gold surface. The arrayed PEG dots are not affected the during PP spin-coating step because of their intrinsic immiscibility. Consequently, the hole-patterned PP film is obtained after PEG removal. The electrochemical signal of the PP film demonstrates the negligible leakage current by high dielectric and self-healing of defects on the chemical pattern by the polymer. This method is applicable to fabrication of microelectrode arrays and possibly can be employed to fabricate a variety of functional polymeric structures, such as photomasks, arrays of biomolecules, cell arrays, and arrays of nanomaterials.
- 20 November 2007
- Published by Wiley in Electroanalysis
- Vol. 19 (23) , 2428-2436
A Penicillamine Biosensor Based on Tyrosinase Immobilized on Nano‐Au/ PAMAM Dendrimer Modified Gold Electrode
- 20 November 2007
- Published by Wiley in Electroanalysis
- Vol. 19 (23) , 2428-2436
A Penicillamine Biosensor Based on Tyrosinase Immobilized on Nano‐Au/ PAMAM Dendrimer Modified Gold Electrode
- 1 February 2002
- Published by Elsevier in Electrochemistry Communications
- Vol. 4 (2) , 128-133
Effects of dopant anions and N-substituents on the electrochemical behavior of polypyrrole films in propylene carbonate solution
- 1 February 2002
- Published by Elsevier in Electrochemistry Communications
- Vol. 4 (2) , 128-133
Effects of dopant anions and N-substituents on the electrochemical behavior of polypyrrole films in propylene carbonate solution