Chad Seidel
Chad Seidel has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Carleigh Samson
Corona Environmental Consulting, LLC Louisville Colorado USA
5 shared publications - Sheldon V. Masters
Environmental Engineering Program
3 shared publications - Anthony Kennedy
Brown and Caldwell Lakewood Colorado USA
2 shared publications - Brittany Gregory
Corona Environmental Consulting, LLC Louisville Colorado USA
2 shared publications Christian Mathews
Corona Environmental Consulting LLC, CO Louisville Colorado USA
2 shared publications- Amlan Ghosh
Corona Environmental Consulting, Lewisville, Texas 75067, United States
1 shared publication
Latest Publications
- Open Access
- 14 September 2026
- Published by Wiley in AWWA Water Science
- Vol. 8 (5) , e70060
Responding to Post‐Wildfire Water System VOCs and SVOCs
The 2021 Marshall Fire burned 593 properties within the City of Louisville, CO, and over 1,000 properties total. Responding to fire impacts on the drinking water system, Louisville developed a sampling and flushing recovery plan to address volatile organic compounds (VOCs) and semi‐volatile organic compounds (SVOCs). Of the 882 samples collected and 94,469 individual VOC and SVOC analyses conducted, 528 (0.56%) analyses were above the method reporting limit, and 31 of those (0.03%) exceeded an MCL. VOC analysis alone captured 85% of all detections and captured 100% of all MCL exceedances. Benzene was not a comprehensive surrogate for the presence of all VOCs detected in Louisville. Flushing reduced fire‐related contamination below health limits in Louisville's distribution system. After one flush, > 95% of samples were below the MCL; all samples were below the MCL after a second flush. Key findings are summarized for water systems preparing for and responding to wildfires.
- 14 September 2026
- Published by Wiley in AWWA Water Science
- Vol. 8 (5) , e70060
Open AccessResponding to Post‐Wildfire Water System VOCs and SVOCs
The 2021 Marshall Fire burned 593 properties within the City of Louisville, CO, and over 1,000 properties total. Responding to fire impacts on the drinking water system, Louisville developed a sampling and flushing recovery plan to address volatile organic compounds (VOCs) and semi‐volatile organic compounds (SVOCs). Of the 882 samples collected and 94,469 individual VOC and SVOC analyses conducted, 528 (0.56%) analyses were above the method reporting limit, and 31 of those (0.03%) exceeded an MCL. VOC analysis alone captured 85% of all detections and captured 100% of all MCL exceedances. Benzene was not a comprehensive surrogate for the presence of all VOCs detected in Louisville. Flushing reduced fire‐related contamination below health limits in Louisville's distribution system. After one flush, > 95% of samples were below the MCL; all samples were below the MCL after a second flush. Key findings are summarized for water systems preparing for and responding to wildfires.
- Open Access
- 21 May 2026
- Published by Wiley in AWWA Water Science
- Vol. 8 (3) , e70055
Legionella Occurrence in Buildings: Implications of Public Water System Disinfectant and Residual
Legionella pneumophila is an opportunistic drinking water microorganism of serious health concern. Anticipated revisions to U.S. EPA's Microbial and Disinfection Byproduct Rules may propose a numeric minimum disinfectant residual—rather than the current “detectable”—in part to better control Legionella in drinking water distribution systems and buildings served. Data to inform distribution system disinfectant residual concentration impacts on L. pneumophila concerns in buildings are scarce. In 2024, the General Services Administration tested water quality, including Legionella , at ~8250 federally owned and leased buildings. This study analyzed summary data from ~5600 buildings, detailed results from 40 buildings, and corresponding distribution system disinfectant residuals to assess links between residual levels and Legionella occurrence. Utilizing this largest and most nationally representative dataset available to date, findings varied by building and water system, with no clear numeric distribution system residual threshold consistently linked to lower Legionella occurrence in buildings.
- 21 May 2026
- Published by Wiley in AWWA Water Science
- Vol. 8 (3) , e70055
Open AccessLegionella Occurrence in Buildings: Implications of Public Water System Disinfectant and Residual
Legionella pneumophila is an opportunistic drinking water microorganism of serious health concern. Anticipated revisions to U.S. EPA's Microbial and Disinfection Byproduct Rules may propose a numeric minimum disinfectant residual—rather than the current “detectable”—in part to better control Legionella in drinking water distribution systems and buildings served. Data to inform distribution system disinfectant residual concentration impacts on L. pneumophila concerns in buildings are scarce. In 2024, the General Services Administration tested water quality, including Legionella , at ~8250 federally owned and leased buildings. This study analyzed summary data from ~5600 buildings, detailed results from 40 buildings, and corresponding distribution system disinfectant residuals to assess links between residual levels and Legionella occurrence. Utilizing this largest and most nationally representative dataset available to date, findings varied by building and water system, with no clear numeric distribution system residual threshold consistently linked to lower Legionella occurrence in buildings.
- 1 January 2026
- Published by Wiley in AWWA Water Science
- Vol. 8 (1)
Disinfection Byproducts: Health Risks, Occurrence, Control, and Implications for Regulatory Revision
Research on drinking water disinfection continues to find both supporting and non‐supporting evidence that trihalomethanes (THMs) and haloacetic acids (HAAs) are causative agents for adverse human health effects such as bladder cancer and that they are appropriate surrogates for reducing adverse health effects through further regulation. The EPA is revising the microbial/disinfection byproduct (M/DBP) rules to further protect public health; however, the decision to change or add regulations is hindered by uncertainty about the causative agents of DBP‐associated risk and the role of compliance strategies to protect public health. Research conducted since the Stage 2 DBP rule was established helps fill some gaps and outlines lingering uncertainties that should be acknowledged as part of revised rulemaking. This thematic review summarizes regulatory implications of the state of the science in epidemiology, toxicology, occurrence/monitoring, and treatment/compliance, and identifies actions toward meaningful regulatory revisions despite ongoing uncertainty of DBP‐associated human health risk drivers.
- 1 January 2026
- Published by Wiley in AWWA Water Science
- Vol. 8 (1)
Disinfection Byproducts: Health Risks, Occurrence, Control, and Implications for Regulatory Revision
Research on drinking water disinfection continues to find both supporting and non‐supporting evidence that trihalomethanes (THMs) and haloacetic acids (HAAs) are causative agents for adverse human health effects such as bladder cancer and that they are appropriate surrogates for reducing adverse health effects through further regulation. The EPA is revising the microbial/disinfection byproduct (M/DBP) rules to further protect public health; however, the decision to change or add regulations is hindered by uncertainty about the causative agents of DBP‐associated risk and the role of compliance strategies to protect public health. Research conducted since the Stage 2 DBP rule was established helps fill some gaps and outlines lingering uncertainties that should be acknowledged as part of revised rulemaking. This thematic review summarizes regulatory implications of the state of the science in epidemiology, toxicology, occurrence/monitoring, and treatment/compliance, and identifies actions toward meaningful regulatory revisions despite ongoing uncertainty of DBP‐associated human health risk drivers.
- Open Access
- 1 September 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (5)
Estimating the impact of the proposed Lead and Copper Rule Improvements
Lead in drinking water can lead to serious health effects, including neurodevelopmental issues and heart disease. In December 2023, the U.S. Environmental Protection Agency (EPA) proposed the Lead and Copper Rule Improvements (LCRI), which lower the Lead and Copper Rule's (LCR's) lead action level (AL) from 15 parts per billion (ppb) to 10 ppb and require both first‐ and fifth‐liter sampling and 90th percentile compliance calculations based on the highest lead levels at sites with lead service lines. A methodology for estimating the likelihood a system will have an AL exceedance (ALE) under the LCRI was developed using Michigan LCR compliance data and applied to national LCR compliance data. Findings were compared to EPA's estimates, indicating EPA may have underestimated the percent of smaller systems (serving 3300) with ALEs and overestimated the percent of larger systems (serving > 10,000), thus underestimating costs and overestimating the benefits of this rulemaking.
- 1 September 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (5)
Open AccessEstimating the impact of the proposed Lead and Copper Rule Improvements
Lead in drinking water can lead to serious health effects, including neurodevelopmental issues and heart disease. In December 2023, the U.S. Environmental Protection Agency (EPA) proposed the Lead and Copper Rule Improvements (LCRI), which lower the Lead and Copper Rule's (LCR's) lead action level (AL) from 15 parts per billion (ppb) to 10 ppb and require both first‐ and fifth‐liter sampling and 90th percentile compliance calculations based on the highest lead levels at sites with lead service lines. A methodology for estimating the likelihood a system will have an AL exceedance (ALE) under the LCRI was developed using Michigan LCR compliance data and applied to national LCR compliance data. Findings were compared to EPA's estimates, indicating EPA may have underestimated the percent of smaller systems (serving 3300) with ALEs and overestimated the percent of larger systems (serving > 10,000), thus underestimating costs and overestimating the benefits of this rulemaking.
- 1 July 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (4)
Risks of stannous chloride without filtration for hexavalent chromium treatment
With increasing interest in using stannous chloride without filtration to achieve hexavalent chromium maximum contaminant level compliance in California, there is new urgency to quantify its effects on water quality and risks to public health manifested in distribution and premise plumbing systems. Accordingly, a 12‐week groundwater pilot study was completed using ubiquitous premise plumbing materials under flowing (to waste) and stagnating conditions of hexavalent chromium‐containing groundwater following stannous chloride addition without filtration. Results quantified the accumulation and release of chromium and tin, with total chromium concentrations exceeding regulatory or acceptable levels under stagnating conditions. Sediment with elevated chromium, tin, arsenic, and manganese concentrations was also observed. Given these observations would likely occur and worsen over time in distribution systems that cumulatively serve large populations, the use of stannous chloride without filtration represents an unacceptable risk to public health compared to other, more well‐established, best available technologies.
- 1 July 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (4)
Risks of stannous chloride without filtration for hexavalent chromium treatment
With increasing interest in using stannous chloride without filtration to achieve hexavalent chromium maximum contaminant level compliance in California, there is new urgency to quantify its effects on water quality and risks to public health manifested in distribution and premise plumbing systems. Accordingly, a 12‐week groundwater pilot study was completed using ubiquitous premise plumbing materials under flowing (to waste) and stagnating conditions of hexavalent chromium‐containing groundwater following stannous chloride addition without filtration. Results quantified the accumulation and release of chromium and tin, with total chromium concentrations exceeding regulatory or acceptable levels under stagnating conditions. Sediment with elevated chromium, tin, arsenic, and manganese concentrations was also observed. Given these observations would likely occur and worsen over time in distribution systems that cumulatively serve large populations, the use of stannous chloride without filtration represents an unacceptable risk to public health compared to other, more well‐established, best available technologies.
- 1 May 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (3)
Impacts of setting a numeric minimum disinfectant residual for public water system distribution systems
US Environmental Protection Agency (EPA) requires public water systems (PWSs) that disinfect to maintain a detectable disinfectant residual throughout the distribution system (DS) to protect consumers against risks from microbial pathogens. The EPA is tasked with proposing revisions to the Microbial, Disinfectant, and Disinfection Byproduct rules by July 2025. Potential revisions could include a numeric minimum disinfectant residual level in place of the “detectable” requirement. Twenty‐three states have defined a required DS numeric minimum disinfectant residual level. Only three such states, Louisiana, Colorado, and Pennsylvania, have made recent changes and have sufficient data available to assess implications. These states were used as case studies to assess the impact this regulatory change had on disinfectant residual levels and microbial and disinfection byproduct (DBP) occurrence in PWS DSs. Results included increases in disinfectant residual levels, decreases in total coliform positive occurrences and violations, and temporary increases in DBP occurrence and violations.
- 1 May 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (3)
Impacts of setting a numeric minimum disinfectant residual for public water system distribution systems
US Environmental Protection Agency (EPA) requires public water systems (PWSs) that disinfect to maintain a detectable disinfectant residual throughout the distribution system (DS) to protect consumers against risks from microbial pathogens. The EPA is tasked with proposing revisions to the Microbial, Disinfectant, and Disinfection Byproduct rules by July 2025. Potential revisions could include a numeric minimum disinfectant residual level in place of the “detectable” requirement. Twenty‐three states have defined a required DS numeric minimum disinfectant residual level. Only three such states, Louisiana, Colorado, and Pennsylvania, have made recent changes and have sufficient data available to assess implications. These states were used as case studies to assess the impact this regulatory change had on disinfectant residual levels and microbial and disinfection byproduct (DBP) occurrence in PWS DSs. Results included increases in disinfectant residual levels, decreases in total coliform positive occurrences and violations, and temporary increases in DBP occurrence and violations.
- Open Access
- 17 January 2023
- Published by Wiley in AWWA Water Science
- Vol. 5 (1)
The Marshall Fire: Scientific and policy needs for water system disaster response
The 2021 Marshall Fire was the costliest fire in Colorado's history and destroyed more than 1,000 homes and businesses. The disaster displaced over 40,000 people and damaged six public drinking water systems. A case study was developed to better understand decisions, resources, expertise, and response limitations during and after the wildfire. The fire caused all water systems to lose power. Power loss was sometimes coupled with structure destruction, distribution depressurization, and the failure of backup power systems. These consequences jeopardized fire‐fighting support and allowed for volatile organic compound and semi‐volatile organic compound contamination of water distribution systems. Water system staff, with help from neighboring systems and external technical experts, stabilized the infrastructure, found and removed the contamination, and restored services. Actions were identified for utilities, governments, and researchers that could help communities minimize wildfire impacts, better protect workers and the population, and enable water systems to more rapidly respond and recover.
- 17 January 2023
- Published by Wiley in AWWA Water Science
- Vol. 5 (1)
Open AccessThe Marshall Fire: Scientific and policy needs for water system disaster response
The 2021 Marshall Fire was the costliest fire in Colorado's history and destroyed more than 1,000 homes and businesses. The disaster displaced over 40,000 people and damaged six public drinking water systems. A case study was developed to better understand decisions, resources, expertise, and response limitations during and after the wildfire. The fire caused all water systems to lose power. Power loss was sometimes coupled with structure destruction, distribution depressurization, and the failure of backup power systems. These consequences jeopardized fire‐fighting support and allowed for volatile organic compound and semi‐volatile organic compound contamination of water distribution systems. Water system staff, with help from neighboring systems and external technical experts, stabilized the infrastructure, found and removed the contamination, and restored services. Actions were identified for utilities, governments, and researchers that could help communities minimize wildfire impacts, better protect workers and the population, and enable water systems to more rapidly respond and recover.
- 6 January 2023
- Published by Wiley in AWWA Water Science
- Vol. 5 (1)
Improvements in the reduction coagulation filtration process for hexavalent chromium treatment
Reduction coagulation filtration using ferrous iron (Fe(II)‐RCF), or reduction filtration using stannous tin (Sn(II)‐RF), for the removal of hexavalent chromium (Cr(VI)) from drinking water represent attractive alternatives to ion exchange or reverse osmosis. With a new maximum contaminant level for Cr(VI) anticipated in California, this study sought to expand on previous research by applying Fe(II)‐RCF and Sn(II)‐RF to multiple groundwaters under a variety of reductant dose and reduction time scenarios. Four different granular filter media were also tested for removal of total chromium (Cr(T)) following Cr(VI) reduction to trivalent chromium (Cr(III)). Sodium hypochlorite, instead of aeration, was used to oxidize excess Fe(II) to Fe(III) prior to filtration, with minimal Cr(III) to Cr(VI) reoxidation. Sn(II)‐RF was also able to achieve Cr(T) and Cr(VI) treatment goals without dedicated reduction time prior to filtration. Results of this study were used to develop more up‐to‐date, feasibility‐level, 20‐year annualized cost estimates.
- 6 January 2023
- Published by Wiley in AWWA Water Science
- Vol. 5 (1)
Improvements in the reduction coagulation filtration process for hexavalent chromium treatment
Reduction coagulation filtration using ferrous iron (Fe(II)‐RCF), or reduction filtration using stannous tin (Sn(II)‐RF), for the removal of hexavalent chromium (Cr(VI)) from drinking water represent attractive alternatives to ion exchange or reverse osmosis. With a new maximum contaminant level for Cr(VI) anticipated in California, this study sought to expand on previous research by applying Fe(II)‐RCF and Sn(II)‐RF to multiple groundwaters under a variety of reductant dose and reduction time scenarios. Four different granular filter media were also tested for removal of total chromium (Cr(T)) following Cr(VI) reduction to trivalent chromium (Cr(III)). Sodium hypochlorite, instead of aeration, was used to oxidize excess Fe(II) to Fe(III) prior to filtration, with minimal Cr(III) to Cr(VI) reoxidation. Sn(II)‐RF was also able to achieve Cr(T) and Cr(VI) treatment goals without dedicated reduction time prior to filtration. Results of this study were used to develop more up‐to‐date, feasibility‐level, 20‐year annualized cost estimates.
- 3 November 2022
- Published by Wiley in AWWA Water Science
- Vol. 4 (6)
Assessing national HAA9 occurrence and impacts of a potential HAA9 regulation
The US Environmental Protection Agency is tasked with proposing revisions to Microbial and Disinfectant and Disinfection Byproducts rules (DBPR) by 2025. Disinfection byproducts are currently regulated by the Stage 2 DBPR, inclusive of total trihalomethane and five haloacetic acids (HAA5). EPA's Fourth Unregulated Contaminant Monitoring Rule (UCMR4) included monitoring for HAA5, six brominated haloacetic acids (HAA6Br), and nine haloacetic acids (HAA9). UCMR4 and state‐managed compliance data were utilized to assess the potential impacts of regulating HAA9. HAA9 modeling techniques were validated and applied for greater representation of smaller systems. Outcomes suggest a HAA9 maximum contaminant level (MCL) equivalent to the HAA5 MCL by number of public water systems (PWSs) implicated would be between 72–77 μg/L. An additional 395 PWSs (2%) not currently implicated by Stage 2 DBPR would have compliance challenges if HAA9 is regulated with an MCL equal to the 60 μg/L HAA5 MCL.
- 3 November 2022
- Published by Wiley in AWWA Water Science
- Vol. 4 (6)
Assessing national HAA9 occurrence and impacts of a potential HAA9 regulation
The US Environmental Protection Agency is tasked with proposing revisions to Microbial and Disinfectant and Disinfection Byproducts rules (DBPR) by 2025. Disinfection byproducts are currently regulated by the Stage 2 DBPR, inclusive of total trihalomethane and five haloacetic acids (HAA5). EPA's Fourth Unregulated Contaminant Monitoring Rule (UCMR4) included monitoring for HAA5, six brominated haloacetic acids (HAA6Br), and nine haloacetic acids (HAA9). UCMR4 and state‐managed compliance data were utilized to assess the potential impacts of regulating HAA9. HAA9 modeling techniques were validated and applied for greater representation of smaller systems. Outcomes suggest a HAA9 maximum contaminant level (MCL) equivalent to the HAA5 MCL by number of public water systems (PWSs) implicated would be between 72–77 μg/L. An additional 395 PWSs (2%) not currently implicated by Stage 2 DBPR would have compliance challenges if HAA9 is regulated with an MCL equal to the 60 μg/L HAA5 MCL.
- 6 July 2022
- Published by Wiley in AWWA Water Science
- Vol. 4 (4)
Comparison of coupon and pipe rack studies for selecting corrosion control treatment
This study directly compared the data obtained from coupon studies and flow‐through pipe rack studies from two sources in the Denver Water system. The pipe rack study was completed over multiple years using harvested lead service lines. The coupon studies were completed in about 2 months using pure lead coupons. Orthophosphate at 2 mg/L was found to reduce lead concentrations by about 81% in the pipe racks, whereas 74%–81% was observed in the coupons. At an orthophosphate dose of 1 mg/L lead concentrations were reduced by 62%–65% in the pipe loop and by 55%–75% in the coupons, pH at 8.8 reduced lead by 45%–60% in the pipe racks and by 27%–48% in the coupons. The pipe racks were able to give insights into the transition from one condition to another, which is time‐based and dependent on existing pipe scales. Both types of demonstration studies produced similar conclusions about treatment options. The pipe rack was more representative of conditions in the distribution system while the coupon studies were performed in a fraction of the time.
- 6 July 2022
- Published by Wiley in AWWA Water Science
- Vol. 4 (4)
Comparison of coupon and pipe rack studies for selecting corrosion control treatment
This study directly compared the data obtained from coupon studies and flow‐through pipe rack studies from two sources in the Denver Water system. The pipe rack study was completed over multiple years using harvested lead service lines. The coupon studies were completed in about 2 months using pure lead coupons. Orthophosphate at 2 mg/L was found to reduce lead concentrations by about 81% in the pipe racks, whereas 74%–81% was observed in the coupons. At an orthophosphate dose of 1 mg/L lead concentrations were reduced by 62%–65% in the pipe loop and by 55%–75% in the coupons, pH at 8.8 reduced lead by 45%–60% in the pipe racks and by 27%–48% in the coupons. The pipe racks were able to give insights into the transition from one condition to another, which is time‐based and dependent on existing pipe scales. Both types of demonstration studies produced similar conclusions about treatment options. The pipe rack was more representative of conditions in the distribution system while the coupon studies were performed in a fraction of the time.