Yuanyuan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuanyuan Li has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Xiaoling Chen
Department of Laboratory Medicine, the First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China; Zhejiang Key Laboratory of Clinical In Vitro Diagnostic Techniques, Hangzhou, China; Institute of Laboratory Medicine, Zhejiang University, Hangzhou, China
1 shared publication- Xiaoling Chen
Key Laboratory for Animal Disease-Resistance Nutrition of China Ministry of Education, Institute of Animal Nutrition, Sichuan Agricultural University, Chengdu, P. R. China
1 shared publication - Xiaoling Chen
Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
1 shared publication - Xiaoyan Zhang
Department of Laboratory Medicine, the First Affiliated Hospital, College of Medicine Zhejiang University Hangzhou China
1 shared publication - Ying Zhao
Department of Laboratory Medicine, the First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China; Zhejiang Key Laboratory of Clinical In Vitro Diagnostic Techniques, Hangzhou, China; Institute of Laboratory Medicine, Zhejiang University, Hangzhou, China
1 shared publication - Ying Zhao
Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
1 shared publication
Latest Publications
- Open Access
- 6 August 2026
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
Patient-Based Real-Time Quality Control for Semiquantitative Tests Based on Hierarchical Differences
Yuanyuan Li, M.S., Xiaoling Chen, M.T., and Ying Zhao, M.D.. Ann Lab Med -0001;0:. https://doi.org/10.3343/alm.2026.0055
- 6 August 2026
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
Open AccessPatient-Based Real-Time Quality Control for Semiquantitative Tests Based on Hierarchical Differences
Yuanyuan Li, M.S., Xiaoling Chen, M.T., and Ying Zhao, M.D.. Ann Lab Med -0001;0:. https://doi.org/10.3343/alm.2026.0055
- 24 February 2025
- Published by Elsevier in Clinica Chimica Acta
- Vol. 570, 120214
Double-module ratio as a patient-based real-time quality control index for small shift detection and comparative assay
- 24 February 2025
- Published by Elsevier in Clinica Chimica Acta
- Vol. 570, 120214
Double-module ratio as a patient-based real-time quality control index for small shift detection and comparative assay
- Open Access
- 14 September 2021
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 35 (10) , e23985
Comparison and optimization of various moving patient‐based real‐time quality control procedures for serum sodium
Background: Patient‐based real‐time quality control (PBRTQC) is a valuable tool for monitoring the performance of testing processes. We aimed to compare and optimize various PBRTQC procedures for serum sodium.Methods: In a computer simulation, artificial errors were added to 680,000 real patients’ results. The characteristics of error detection of various algorithms—moving average, moving median, moving SD and moving proportion of normal results including different control limits (CLs)—were assessed on their ability to detect critical errors early.Results: The moving average and moving median were sensitive to system error, and the moving SD tended to detect random error. P3SD (moving proportion of normal results, CLs based on mean and SD of proportion of normal results) demonstrated excellent performance for both system error and random error. The increase of block sizes (N) leads to the delay of error detection and the decrease of false rejection, except for QC procedures with minimum and maximum as CLs. CLs calculation with “0.1% false alarm rate” had more effective performance than that set false alarm to zero (minimum and maximum as CLs). The impact of truncation on QC performance depended on truncation limits, algorithms and the types of error. The significant improvement in QC performance due to truncation was only found in moving SD.Conclusion: “P3SD,N = 50, without truncation” and “moving SD, N = 25, set 0.1% false alarm as CLs and set 1% outliers exclusion as truncation limits” were recommended as the optimized procedures for serum sodium to monitor system error and random error, respectively.
- 14 September 2021
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 35 (10) , e23985
Open AccessComparison and optimization of various moving patient‐based real‐time quality control procedures for serum sodium
Background: Patient‐based real‐time quality control (PBRTQC) is a valuable tool for monitoring the performance of testing processes. We aimed to compare and optimize various PBRTQC procedures for serum sodium.Methods: In a computer simulation, artificial errors were added to 680,000 real patients’ results. The characteristics of error detection of various algorithms—moving average, moving median, moving SD and moving proportion of normal results including different control limits (CLs)—were assessed on their ability to detect critical errors early.Results: The moving average and moving median were sensitive to system error, and the moving SD tended to detect random error. P3SD (moving proportion of normal results, CLs based on mean and SD of proportion of normal results) demonstrated excellent performance for both system error and random error. The increase of block sizes (N) leads to the delay of error detection and the decrease of false rejection, except for QC procedures with minimum and maximum as CLs. CLs calculation with “0.1% false alarm rate” had more effective performance than that set false alarm to zero (minimum and maximum as CLs). The impact of truncation on QC performance depended on truncation limits, algorithms and the types of error. The significant improvement in QC performance due to truncation was only found in moving SD.Conclusion: “P3SD,N = 50, without truncation” and “moving SD, N = 25, set 0.1% false alarm as CLs and set 1% outliers exclusion as truncation limits” were recommended as the optimized procedures for serum sodium to monitor system error and random error, respectively.