Peter Dziewulski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Peter Dziewulski has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Charles Yuen Yung Loh
Department of Plastic Surgery, Addenbrookes Hospital, Cambridge, United Kingdom
1 shared publication - Georgina Phillips
Department of General Surgery, Imperial College NHS London, London, UK
1 shared publication - Ishan Radotra
Univ Hosp North Midlands, Dept Plast Surg, Newcastle Rd, Stoke on Trent ST4 6QG, England
1 shared publication - Joseph Ward
Department of Plastic Surgery, Queen Victoria Hospital, East Grinstead RH19 3DZ, UK
1 shared publication - Joshua Michael Peterson
The University of Texas Medical Branch at Galveston, Galveston, USA
1 shared publication - Jufen Zhang
School of Medicine, Anglia Ruskin University, Chelmsford, UK
1 shared publication
Latest Publications
- Open Access
- 1 September 2021
- Published by Georg Thieme Verlag KG in Archives of Plastic Surgery
- Vol. 48 (05) , 570-571
A multistep approach to preventing wrong site surgery in skin lesion excision
- 1 September 2021
- Published by Georg Thieme Verlag KG in Archives of Plastic Surgery
- Vol. 48 (05) , 570-571
Open AccessA multistep approach to preventing wrong site surgery in skin lesion excision
- 1 April 2021
- Published by Oxford University Press (OUP) in Journal of Burn Care & Research
- Vol. 42 (Supplement) , S173-S174
635 Free Versus Pedicled Flaps for Primary Reconstruction of Electrical Injuries: A Systematic Review and Observational Meta-Analysis
Both high-voltage (>1000 V) and low-voltage (< 1000 V) electrical burns can cause serious injuries due to dissipation of heat as electric current passes through deep tissues. Because of tissue loss and vital structure exposure, flap-based reconstruction is frequently performed in patients with these injuries. Depending on clinical presentation, both free and pedicled flaps may be indicated. We wondered if reported reconstructive outcomes after electrical injury differ between free and pedicled flaps when implemented in the immediate post-injury period. A systematic literature review following PRISMA guidelines was conducted using PubMed and Ovid MEDLINE databases. Articles that were included described patients with electrical burn injuries who underwent reconstruction with either free or pedicled flaps within 90 days of injury. Technique articles or articles lacking outcomes analysis were excluded. Data was extracted from articles that met inclusion and exclusion criteria, including flap type, timing of reconstruction, complications, and patient demographics. Statistical analysis was performed with chi-square tests. Of 536 articles obtained from the literature search, 37 met criteria. To date, no randomized control trials comparing these modalities have been performed. In total, these studies reported on 364 total patients who experienced high- and low-voltage electrical burn injuries. Pooled reported outcomes of 374 flap reconstructions were analyzed, including 145 free flaps and 229 pedicled flaps. Reported complication rates did not differ significantly between free flaps (30/145, 20.7%) and pedicled flaps (46/229, 20.1%; p = .89). However, free flaps experienced significantly higher failure rates than pedicled flaps (13/145, 9.0% vs. 0/229, 0%; p = < .05). Electrical burn injuries present a unique indication for flap-based reconstruction in the immediate post-burn phase of care. However, substantial variation exists amongst physicians regarding whether to proceed with a free flap or pedicled flap surgery when indicated. Our data identified an overall significant difference between free versus pedicled flap failure rate but did not identify a significant difference between overall complication rates.
- 1 April 2021
- Published by Oxford University Press (OUP) in Journal of Burn Care & Research
- Vol. 42 (Supplement) , S173-S174
635 Free Versus Pedicled Flaps for Primary Reconstruction of Electrical Injuries: A Systematic Review and Observational Meta-Analysis
Both high-voltage (>1000 V) and low-voltage (< 1000 V) electrical burns can cause serious injuries due to dissipation of heat as electric current passes through deep tissues. Because of tissue loss and vital structure exposure, flap-based reconstruction is frequently performed in patients with these injuries. Depending on clinical presentation, both free and pedicled flaps may be indicated. We wondered if reported reconstructive outcomes after electrical injury differ between free and pedicled flaps when implemented in the immediate post-injury period. A systematic literature review following PRISMA guidelines was conducted using PubMed and Ovid MEDLINE databases. Articles that were included described patients with electrical burn injuries who underwent reconstruction with either free or pedicled flaps within 90 days of injury. Technique articles or articles lacking outcomes analysis were excluded. Data was extracted from articles that met inclusion and exclusion criteria, including flap type, timing of reconstruction, complications, and patient demographics. Statistical analysis was performed with chi-square tests. Of 536 articles obtained from the literature search, 37 met criteria. To date, no randomized control trials comparing these modalities have been performed. In total, these studies reported on 364 total patients who experienced high- and low-voltage electrical burn injuries. Pooled reported outcomes of 374 flap reconstructions were analyzed, including 145 free flaps and 229 pedicled flaps. Reported complication rates did not differ significantly between free flaps (30/145, 20.7%) and pedicled flaps (46/229, 20.1%; p = .89). However, free flaps experienced significantly higher failure rates than pedicled flaps (13/145, 9.0% vs. 0/229, 0%; p = < .05). Electrical burn injuries present a unique indication for flap-based reconstruction in the immediate post-burn phase of care. However, substantial variation exists amongst physicians regarding whether to proceed with a free flap or pedicled flap surgery when indicated. Our data identified an overall significant difference between free versus pedicled flap failure rate but did not identify a significant difference between overall complication rates.