Corey A. Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Corey A. Smith has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Balwantray C. Chauhan
Department of Ophthalmology and Visual Sciences, Dalhousie University and Nova Scotia Health, Halifax, Nova Scotia, Canada
7 shared publications Glen P Sharpe
Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
2 shared publications- Jayme Augusto Rocha Vianna
Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
2 shared publications - Kathleen A. Hill
Department of Biology, University of Western Ontario
2 shared publications Lesya M Shuba
Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
2 shared publicationsMarcelo T Nicolela
Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
2 shared publications
Latest Publications
- Open Access
- 7 July 2026
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 25 (1)
Biomechanics of the retina: experimental and clinical perspectives
The retina is an essential component of the visual system, a delicate neural tissue that converts light signals into electrical impulses and links the visual environment to the brain. Its structure and functional performance depend on multiple layers of interconnected cells and extracellular matrix components that together provide mechanical support. The retina’s biomechanical properties, including elasticity, stiffness, and tensile strength, govern how it deforms and recovers under physiological load and mechanical stress. Quantifying these properties is essential for understanding how the retina resists tractional and compressive forces that can lead to injury or disease. Techniques including tensile testing, atomic force microscopy, optical coherence elastography, Brillouin microscopy, and computational modeling have advanced our understanding of retinal stiffness and revealed altered tissue mechanics in ocular disease. This review describes current knowledge of retinal structure and material behavior, experimental and computational approaches used to assess mechanical properties, and how biomechanical changes contribute to the development and progression of retinal disorders.
- 7 July 2026
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 25 (1)
Open AccessBiomechanics of the retina: experimental and clinical perspectives
The retina is an essential component of the visual system, a delicate neural tissue that converts light signals into electrical impulses and links the visual environment to the brain. Its structure and functional performance depend on multiple layers of interconnected cells and extracellular matrix components that together provide mechanical support. The retina’s biomechanical properties, including elasticity, stiffness, and tensile strength, govern how it deforms and recovers under physiological load and mechanical stress. Quantifying these properties is essential for understanding how the retina resists tractional and compressive forces that can lead to injury or disease. Techniques including tensile testing, atomic force microscopy, optical coherence elastography, Brillouin microscopy, and computational modeling have advanced our understanding of retinal stiffness and revealed altered tissue mechanics in ocular disease. This review describes current knowledge of retinal structure and material behavior, experimental and computational approaches used to assess mechanical properties, and how biomechanical changes contribute to the development and progression of retinal disorders.
- Open Access
- 13 February 2026
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 61 (3) , 575-581
Rhegmatogenous retinal detachment in Canadian population: a retrospective cohort study examining incidence and risk factors
- 13 February 2026
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 61 (3) , 575-581
Open AccessRhegmatogenous retinal detachment in Canadian population: a retrospective cohort study examining incidence and risk factors
- Open Access
- 25 February 2025
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 60 (4) , e566-e571
Effect of ginkgo biloba extract on macula and peripapillary perfusion examined using optical coherence tomography angiography
- 25 February 2025
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 60 (4) , e566-e571
Open AccessEffect of ginkgo biloba extract on macula and peripapillary perfusion examined using optical coherence tomography angiography
- 19 October 2023
- Published by BMJ in British Journal of Ophthalmology
- Vol. 108 (7) , 978-983
Variability of scan quality and perfusion density in longitudinal optical coherence tomography angiography imaging
Background/aims Optical coherence tomography angiography (OCT-A) images are subject to variability, but the extent to which learning impacts OCT-A measurements is unknown. We determined whether there is a learning effect in glaucoma patients and healthy controls imaged with OCT-A. Methods Ninety-one open-angle glaucoma patients and 54 healthy controls were imaged every 4 months over a period of approximately 1 year in this longitudinal cohort study. We analysed 15°×15° scans, centred on the fovea, in one eye of each participant. Two-dimensional projection images for the superficial, intermediate and deep vascular plexuses were exported and binarised after which perfusion density was calculated. Linear mixed-effects models were used to investigate the association between perfusion density and follow-up time. Results The mean (SD) age of glaucoma patients and healthy controls was 67.3 (8.1) years and 62.1 (9.0) years, respectively. There was a significant correlation between perfusion density and scan quality in both glaucoma patients (r=0.50 (95% CI 0.42 to 0.58); pConclusions Perfusion density measurements are subject to increasing experience of either the operator or participant, or a combination of both. These findings have implications for the interpretation of longitudinal measurements with OCT-A.
- 19 October 2023
- Published by BMJ in British Journal of Ophthalmology
- Vol. 108 (7) , 978-983
Variability of scan quality and perfusion density in longitudinal optical coherence tomography angiography imaging
Background/aims Optical coherence tomography angiography (OCT-A) images are subject to variability, but the extent to which learning impacts OCT-A measurements is unknown. We determined whether there is a learning effect in glaucoma patients and healthy controls imaged with OCT-A. Methods Ninety-one open-angle glaucoma patients and 54 healthy controls were imaged every 4 months over a period of approximately 1 year in this longitudinal cohort study. We analysed 15°×15° scans, centred on the fovea, in one eye of each participant. Two-dimensional projection images for the superficial, intermediate and deep vascular plexuses were exported and binarised after which perfusion density was calculated. Linear mixed-effects models were used to investigate the association between perfusion density and follow-up time. Results The mean (SD) age of glaucoma patients and healthy controls was 67.3 (8.1) years and 62.1 (9.0) years, respectively. There was a significant correlation between perfusion density and scan quality in both glaucoma patients (r=0.50 (95% CI 0.42 to 0.58); pConclusions Perfusion density measurements are subject to increasing experience of either the operator or participant, or a combination of both. These findings have implications for the interpretation of longitudinal measurements with OCT-A.
- Open Access
- 11 July 2023
- Published by Wolters Kluwer Health in Cornea
- Vol. 43 (3) , 349-355
Association Between Indication for Descemet Stripping Automated Endothelial Keratoplasty and Rural Residency
Purpose: Residing in rural locations can be a barrier to health care access. This study investigated the impact of residing in rural and small town (RST) areas on Descemet stripping automated endothelial keratoplasty (DSAEK) indications and outcomes in Atlantic Canada. Methods: A retrospective cohort analysis examined consecutive DSAEKs performed in Nova Scotia between 2017 and 2020. Patient rurality was determined by the Statistical Area Classification system developed by Statistics Canada. Univariate and multivariate logistic regression models were used to assess for factors associated with DSAEK indication, including repeat keratoplasty, RST residence status, and travel time. Results: Of 271 DSAEKs during the study period, 87 (32.1%) were performed on the eyes of RST residents. The median postoperative follow-up time was 1.6 years. Undergoing DSAEK for a previous failed keratoplasty was not associated with a higher odds of RST residency (odds ratio [OR], 0.50; 95% confidence interval [CI], 0.19–1.16; P = 0.13) but was associated with travel time (OR, 0.78 for each increasing hour of travel; 95% CI, 0.61–0.99; P = 0.044). RST residency was not associated with the occurrence of graft failure (OR, 0.48; 95% CI, 0.17–1.17; P = 0.13). Conclusions: Residing in a rural area in Atlantic Canada was not associated with DSAEK graft failure. Repeat endothelial keratoplasty was associated with shorter travel time for corneal surgery but not rural residency status. Further research in this field could inform regional health strategies aimed at improving equity and accessibility to ophthalmology subspecialist care.
- 11 July 2023
- Published by Wolters Kluwer Health in Cornea
- Vol. 43 (3) , 349-355
Open AccessAssociation Between Indication for Descemet Stripping Automated Endothelial Keratoplasty and Rural Residency
Purpose: Residing in rural locations can be a barrier to health care access. This study investigated the impact of residing in rural and small town (RST) areas on Descemet stripping automated endothelial keratoplasty (DSAEK) indications and outcomes in Atlantic Canada. Methods: A retrospective cohort analysis examined consecutive DSAEKs performed in Nova Scotia between 2017 and 2020. Patient rurality was determined by the Statistical Area Classification system developed by Statistics Canada. Univariate and multivariate logistic regression models were used to assess for factors associated with DSAEK indication, including repeat keratoplasty, RST residence status, and travel time. Results: Of 271 DSAEKs during the study period, 87 (32.1%) were performed on the eyes of RST residents. The median postoperative follow-up time was 1.6 years. Undergoing DSAEK for a previous failed keratoplasty was not associated with a higher odds of RST residency (odds ratio [OR], 0.50; 95% confidence interval [CI], 0.19–1.16; P = 0.13) but was associated with travel time (OR, 0.78 for each increasing hour of travel; 95% CI, 0.61–0.99; P = 0.044). RST residency was not associated with the occurrence of graft failure (OR, 0.48; 95% CI, 0.17–1.17; P = 0.13). Conclusions: Residing in a rural area in Atlantic Canada was not associated with DSAEK graft failure. Repeat endothelial keratoplasty was associated with shorter travel time for corneal surgery but not rural residency status. Further research in this field could inform regional health strategies aimed at improving equity and accessibility to ophthalmology subspecialist care.
- Open Access
- 17 May 2023
- Published by SAGE Publications in Journal of Vitreoretinal Diseases
- Vol. 7 (5) , 397-403
Risk for Surgical Team Hearing Loss With Vitrectomy
Purpose: To assess sound-level exposure during vitrectomy using 3 of the most common commercially available machines. Methods: This noninterventional cross-sectional study examined sound emission from the Constellation, Stellaris, and EVA vitrector systems. For each machine, a noise dosimeter was used to measure the sound-level exposure of the surgeon during 3 surgical cases in which vitrectomy was performed. Sound levels associated with progressively increasing cut rates and vacuum pressures were also measured. Finally, sound measurements were taken during the use of various additional functions of each machine, including diathermy, laser, and extrusion. Sound levels were compared with occupational health guidelines in Canada and the United States. Results: The maximum sound level recorded during vitrectomy surgery was 88.2 dBA. The mean sound level during vitrectomy surgical cases ranged from 58.5 to 66.8 dBA. A strong positive linear correlation was found between the cut rate and sound level ( r = 0.88-0.98) and the vacuum pressure and sound level ( r = 0.83-0.97). This relationship was consistent across the 3 vitrector systems ( P < .001). Conclusions: Noise exposure during vitrectomy procedures was acceptable but may be sufficient for surgical team activity interference, as described by World Health Organization recommendations. A strong correlation was found between the cut rate and noise exposure. If cut rates continue to increase, attention should be given to ensure that the resulting noise exposure does not threaten the hearing of vitreoretinal surgeons and the operating room staff.
- 17 May 2023
- Published by SAGE Publications in Journal of Vitreoretinal Diseases
- Vol. 7 (5) , 397-403
Open AccessRisk for Surgical Team Hearing Loss With Vitrectomy
Purpose: To assess sound-level exposure during vitrectomy using 3 of the most common commercially available machines. Methods: This noninterventional cross-sectional study examined sound emission from the Constellation, Stellaris, and EVA vitrector systems. For each machine, a noise dosimeter was used to measure the sound-level exposure of the surgeon during 3 surgical cases in which vitrectomy was performed. Sound levels associated with progressively increasing cut rates and vacuum pressures were also measured. Finally, sound measurements were taken during the use of various additional functions of each machine, including diathermy, laser, and extrusion. Sound levels were compared with occupational health guidelines in Canada and the United States. Results: The maximum sound level recorded during vitrectomy surgery was 88.2 dBA. The mean sound level during vitrectomy surgical cases ranged from 58.5 to 66.8 dBA. A strong positive linear correlation was found between the cut rate and sound level ( r = 0.88-0.98) and the vacuum pressure and sound level ( r = 0.83-0.97). This relationship was consistent across the 3 vitrector systems ( P < .001). Conclusions: Noise exposure during vitrectomy procedures was acceptable but may be sufficient for surgical team activity interference, as described by World Health Organization recommendations. A strong correlation was found between the cut rate and noise exposure. If cut rates continue to increase, attention should be given to ensure that the resulting noise exposure does not threaten the hearing of vitreoretinal surgeons and the operating room staff.
- 1 May 2022
- Published by Elsevier in Progress in Retinal and Eye Research
- Vol. 88, 101021
Age and intraocular pressure in murine experimental glaucoma
- 1 May 2022
- Published by Elsevier in Progress in Retinal and Eye Research
- Vol. 88, 101021
Age and intraocular pressure in murine experimental glaucoma
- 27 February 2020
- Published by BMJ in British Journal of Ophthalmology
- Vol. 104 (12) , 1724-1729
Asymmetry analysis of macular optical coherence tomography angiography in patients with glaucoma and healthy subjects
Background/aims Quantitative analysis of optical coherence tomography angiography (OCT-A) images requires a reproducible approach that accounts for sectoral loss. The objective of this study was to determine whether an index that accounts for both global (perfusion density, PD) and asymmetric loss of perfusion, rather than PD alone, more reliably measures loss of perfusion in patients with glaucoma. Methods We analysed macular OCT-A scans of 95 glaucoma patients and 59 control subjects. Two-dimensional projection images corresponding to the superficial vascular plexus were exported and analyses performed to calculate global PD and image asymmetry. An unsigned perfusion asymmetry index (PAI) that included PD and asymmetry (with 1:1 wt) was calculated. Perfusion density and PAI were compared with 10-2 visual field mean deviation and ganglion cell layer (GCL) thickness. Results Median (IQR) visual field mean deviation was −1.73 (−3.76, 0.30) dB for the glaucoma group and 0.67 (0.16, 1.18) dB for the control group. The strength of the correlation with mean deviation was stronger for PAI (r=0.47), compared with PD (r=0.35), whereas with GCL thickness they were comparable (r=0.45 and 0.43, respectively). Compared with controls, mean PD was 12% lower in patients with glaucoma (0.27 vs 0.30), while PAI was 17% lower (0.40 vs 0.48). However, diagnostic accuracy of either PD or PAI was worse than GCL thickness. Conclusions While PAI yielded better correlation with mean deviation and GCL thickness, and a slightly improved separation between patients with glaucoma and healthy controls, diagnostic accuracy was inferior compared with GCL thickness.
- 27 February 2020
- Published by BMJ in British Journal of Ophthalmology
- Vol. 104 (12) , 1724-1729
Asymmetry analysis of macular optical coherence tomography angiography in patients with glaucoma and healthy subjects
Background/aims Quantitative analysis of optical coherence tomography angiography (OCT-A) images requires a reproducible approach that accounts for sectoral loss. The objective of this study was to determine whether an index that accounts for both global (perfusion density, PD) and asymmetric loss of perfusion, rather than PD alone, more reliably measures loss of perfusion in patients with glaucoma. Methods We analysed macular OCT-A scans of 95 glaucoma patients and 59 control subjects. Two-dimensional projection images corresponding to the superficial vascular plexus were exported and analyses performed to calculate global PD and image asymmetry. An unsigned perfusion asymmetry index (PAI) that included PD and asymmetry (with 1:1 wt) was calculated. Perfusion density and PAI were compared with 10-2 visual field mean deviation and ganglion cell layer (GCL) thickness. Results Median (IQR) visual field mean deviation was −1.73 (−3.76, 0.30) dB for the glaucoma group and 0.67 (0.16, 1.18) dB for the control group. The strength of the correlation with mean deviation was stronger for PAI (r=0.47), compared with PD (r=0.35), whereas with GCL thickness they were comparable (r=0.45 and 0.43, respectively). Compared with controls, mean PD was 12% lower in patients with glaucoma (0.27 vs 0.30), while PAI was 17% lower (0.40 vs 0.48). However, diagnostic accuracy of either PD or PAI was worse than GCL thickness. Conclusions While PAI yielded better correlation with mean deviation and GCL thickness, and a slightly improved separation between patients with glaucoma and healthy controls, diagnostic accuracy was inferior compared with GCL thickness.
- Open Access
- 1 April 2019
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 60 (5) , 1556-1565
Optical Coherence Tomography Angiography in Mice: Quantitative Analysis After Experimental Models of Retinal Damage
Purpose: We implemented optical coherence tomography angiography (OCT-A) in mice to: (1) develop quantitative parameters from OCT-A images, (2) measure the reproducibility of the parameters, and (3) determine the impact of experimental models of inner and outer retinal damage on OCT-A findings. Methods: OCT-A images were acquired with a customized system (Spectralis Multiline OCT2). To assess reproducibility, imaging was performed five times over 1 month. Inner retinal damage was induced with optic nerve transection, crush, or intravitreal N-methyl-d-aspartic acid injection in transgenic mice with fluorescently labeled retinal ganglion cells (RGCs). Light-induced retinal damage was induced in albino mice. Mice were imaged at baseline and serially post injury. Perfusion density, vessel length, and branch points were computed from OCT-A images of the superficial, intermediate, and deep vascular plexuses. Results: The range of relative differences measured between sessions across the vascular plexuses were: perfusion density (2.8%–7.0%), vessel length (1.9%–4.1%), and branch points (1.9%–5.0%). In mice with progressive RGC loss, imaged serially and culminating in around 70% loss in the fluorescence signal and 18% loss in inner retinal thickness, there were no measurable changes in any OCT-A parameter up to 4 months post injury that exceeded measurement variability. However, light-induced retinal damage elicited a progressive loss of the deep vascular plexus signal, starting as early as 3 days post injury. Conclusions: Vessel length and branch points were generally the most reproducible among the parameters. Injury causing RGC loss in mice did not elicit an early change in the OCT-A signal.
- 1 April 2019
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 60 (5) , 1556-1565
Open AccessOptical Coherence Tomography Angiography in Mice: Quantitative Analysis After Experimental Models of Retinal Damage
Purpose: We implemented optical coherence tomography angiography (OCT-A) in mice to: (1) develop quantitative parameters from OCT-A images, (2) measure the reproducibility of the parameters, and (3) determine the impact of experimental models of inner and outer retinal damage on OCT-A findings. Methods: OCT-A images were acquired with a customized system (Spectralis Multiline OCT2). To assess reproducibility, imaging was performed five times over 1 month. Inner retinal damage was induced with optic nerve transection, crush, or intravitreal N-methyl-d-aspartic acid injection in transgenic mice with fluorescently labeled retinal ganglion cells (RGCs). Light-induced retinal damage was induced in albino mice. Mice were imaged at baseline and serially post injury. Perfusion density, vessel length, and branch points were computed from OCT-A images of the superficial, intermediate, and deep vascular plexuses. Results: The range of relative differences measured between sessions across the vascular plexuses were: perfusion density (2.8%–7.0%), vessel length (1.9%–4.1%), and branch points (1.9%–5.0%). In mice with progressive RGC loss, imaged serially and culminating in around 70% loss in the fluorescence signal and 18% loss in inner retinal thickness, there were no measurable changes in any OCT-A parameter up to 4 months post injury that exceeded measurement variability. However, light-induced retinal damage elicited a progressive loss of the deep vascular plexus signal, starting as early as 3 days post injury. Conclusions: Vessel length and branch points were generally the most reproducible among the parameters. Injury causing RGC loss in mice did not elicit an early change in the OCT-A signal.
- Open Access
- 24 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-11
In vivo imaging of adeno-associated viral vector labelled retinal ganglion cells
A defining characteristic of optic neuropathies, such as glaucoma, is progressive loss of retinal ganglion cells (RGCs). Current clinical tests only provide weak surrogates of RGC loss, but the possibility of optically visualizing RGCs and quantifying their rate of loss could represent a radical advance in the management of optic neuropathies. In this study we injected two different adeno-associated viral (AAV) vector serotypes in the vitreous to enable green fluorescent protein (GFP) labelling of RGCs in wild-type mice for in vivo and non-invasive imaging. GFP-labelled cells were detected by confocal scanning laser ophthalmoscopy 1-week post-injection and plateaued in density at 4 weeks. Immunohistochemical analysis 5-weeks post-injection revealed labelling specificity to RGCs to be significantly higher with the AAV2-DCX-GFP vector compared to the AAV2-CAG-GFP vector. There were no adverse functional or structural effects of the labelling method as determined with electroretinography and optical coherence tomography, respectively. The RGC-specific positive and negative scotopic threshold responses had similar amplitudes between control and experimental eyes, while inner retinal thickness was also unchanged after injection. As a positive control experiment, optic nerve transection resulted in a progressive loss of labelled RGCs. AAV vectors provide strong and long-lasting GFP labelling of RGCs without detectable adverse effects.
- 24 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-11
Open AccessIn vivo imaging of adeno-associated viral vector labelled retinal ganglion cells
A defining characteristic of optic neuropathies, such as glaucoma, is progressive loss of retinal ganglion cells (RGCs). Current clinical tests only provide weak surrogates of RGC loss, but the possibility of optically visualizing RGCs and quantifying their rate of loss could represent a radical advance in the management of optic neuropathies. In this study we injected two different adeno-associated viral (AAV) vector serotypes in the vitreous to enable green fluorescent protein (GFP) labelling of RGCs in wild-type mice for in vivo and non-invasive imaging. GFP-labelled cells were detected by confocal scanning laser ophthalmoscopy 1-week post-injection and plateaued in density at 4 weeks. Immunohistochemical analysis 5-weeks post-injection revealed labelling specificity to RGCs to be significantly higher with the AAV2-DCX-GFP vector compared to the AAV2-CAG-GFP vector. There were no adverse functional or structural effects of the labelling method as determined with electroretinography and optical coherence tomography, respectively. The RGC-specific positive and negative scotopic threshold responses had similar amplitudes between control and experimental eyes, while inner retinal thickness was also unchanged after injection. As a positive control experiment, optic nerve transection resulted in a progressive loss of labelled RGCs. AAV vectors provide strong and long-lasting GFP labelling of RGCs without detectable adverse effects.