GBGiulia Bassani

Giulia Bassani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Giulia Bassani has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Novel Compact Rolling Element Eccentric Planetary Gearbox Design for Lightweight and Backdrivable Wearable Robots Actuators

    by Riccardo Bezzini, Simon Fritsch, Giulia Bassani, Carlo Alberto Avizzano, Alessandro Filippeschi

    Wearable assistive exoskeletons require lightweight, compact, and backdrivable transmission systems with low output impedance to ensure safe and comfortable human–robot interaction. These efficient, modular actuators benefit from reduction mechanisms that minimize axial bulk while providing high motion regularity. While existing transmissions perform well on some of these metrics, their practical implementation is often constrained by geometric complexity, low backdrivability, limited reduction ratios, or standard component sizes. This paper presents a novel combination of a Rolling Element Eccentric (REE) stage and a planetary gearbox, specifically designed for wearable exoskeleton actuation. The proposed architecture integrates a bearing-based REE drive concentrically within the sun gear of a planetary transmission, reducing mechanical complexity and friction and improving regularity. Moreover, the design exploits additively manufactured bearings, enabling substantial weight reduction, reduced encumbrance, and increased design freedom without reliance on standard bearing dimensions. A prototype reducer has been designed and fabricated using additive manufacturing techniques. It was experimentally evaluated and compared with state-of-the-art transmission designs. These investigations demonstrated low friction, minimal backlash, good torsional stiffness, and sufficient backdrivability, despite the high reduction ratio, while maintaining a compact, flat form factor. The experimental results indicate that the proposed rolling element eccentric planetary transmission is a viable and effective solution for lightweight, efficient, axially compact (independently of the implemented reduction ratio), and backdrivable actuators in assistive wearable robotics.


  • Open Access

    Human Body Segment Volume Estimation With Front and Back RGB-D Images

    by Giulia Bassani, Emilio Maoddi, Usman Asghar, Carlo Alberto Avizzano, Alessandro Filippeschi

  • Open Access

    Design of a Novel Flat Cycloidal-Planetary Series Reducer and Experimental Assessment for Assistive Exoskeletons Actuation-CYPLO

    by Riccardo Bezzini, Giulia Bassani, Carlo Alberto Avizzano, Alessandro Filippeschi

    The recent advancements in assistive exoskeletons have highlighted their effectiveness in reducing the users’ metabolic consumption, providing functional compensation, and preventing biomechanical overloads. The exoskeletons’ transmission mechanisms are essential for guaranteeing their effectiveness, safety, and comfort. Therefore, lightweight, efficient, backdriveable, and minimally bulky reduction gearboxes with low mechanical output impedance have become a widespread choice in modular assistive exoskeletons. In previous works, the value of the cycloid-planetary series transmission has been assessed. However, the previous design turned out to be too bulky in the axial direction. In this paper, we propose a novel CYcloidal-PLanetary cOncentric series combination (CYPLO) that exploits a compact-cam cycloidal architecture nested inside the sun of a planetary stage. This design enables valuable performance regarding key gearbox features such as regularity, friction, and gear play, while maintaining an extremely advantageous compactness in the axial direction and significant backdriveability even for high transmission ratios. A reducer implementing this novel solution has been designed, developed through 3D printing, and examined experimentally to evaluate its performance with respect to the previous designs and state-of-the-art gearboxes employed in wearable devices’ actuators. The results show that this transmission architecture represents a valid solution for lightweight assistive exoskeletons, allowing for high reduction ratios while maintaining compactness and backdriveability.


  • Open Access

    Deep Learning Algorithms for Human Activity Recognition in Manual Material Handling Tasks

    by Giulia Bassani, Carlo Alberto Avizzano, Alessandro Filippeschi

    Human Activity Recognition (HAR) is widely used for healthcare, but few works focus on Manual Material Handling (MMH) activities, despite their diffusion and impact on the workers’ health. We propose four Deep Learning algorithms for HAR in MMH: Bidirectional Long Short-Term Memory (BiLSTM), Sparse Denoising Autoencoder (Sp-DAE), Recurrent Sp-DAE, and Recurrent Convolutional Neural Network (RCNN). We explored different hyperparameter combinations to maximize the classification performance (F1-score,) using wearable sensors’ data gathered from 14 subjects. We investigated the best three-parameter combinations for each network using the full dataset to select the two best-performing networks, which were then compared using 14 datasets with increasing subject numerosity, 70–30% split, and Leave-One-Subject-Out (LOSO) validation, to evaluate whether they may perform better with a larger dataset. The benchmarking network DeepConvLSTM was tested on the full dataset. BiLSTM performs best in classification and complexity (95.7% 70–30% split; 90.3% LOSO). RCNN performed similarly (95.9%; 89.2%) with a positive trend with subject numerosity. DeepConvLSTM achieves similar classification performance (95.2%; 90.3%) but requires ×57.1 and ×31.3 more Multiply and ACcumulate (MAC) and ×100.8 and ×28.3 more Multiplication and Addition (MA) operations, which measure the complexity of the network’s inference process, than BiLSTM and RCNN, respectively. The BILSTM and RCNN perform close to DeepConvLSTM while being computationally lighter, fostering their use in embedded systems. Such lighter algorithms can be readily used in the automatic ergonomic and biomechanical risk assessment systems, enabling personalization of risk assessment and easing the adoption of safety measures in industrial practices involving MMH.


  • Open Access

    Deep Learning Algorithms for Human Activity Recognition in Manual Material Handling Tasks

    by Giulia Bassani, Carlo Alberto Avizzano, Alessandro Filippeschi

    Human Activity Recognition (HAR) is widely used for healthcare, but few works focus on Manual Material Handling (MMH) activities, despite their diffusion and impact on the workers’ health. We propose four Deep Learning algorithms for HAR in MMH: Bidirectional Long Short-Term Memory (BiLSTM), Sparse Denoising Autoencoder (Sp-DAE), Recurrent Sp-DAE; and Recurrent Convolutional Neural Network (RCNN). We explored different hyperparameter combinations to maximize the classification performance (F1-score) using wearable sensors’ data gathered from 14 subjects. We investigated the best three-parameter combinations for each network using the full dataset to select the two best-performing networks, that were then compared using 14 datasets with increasing subject numerosity, 70%-30% split and Leave-One-Subject-Out (LOSO) validation, to evaluate whether they may perform better with a larger dataset. The benchmarking network DeepConvLSTM was tested on the full dataset. BiLSTM performs best in classification and complexity (95.7% 70%-30% split, 90.3% LOSO). RCNN performed similarly (95.9%, 89.2%) with a positive trend with subject numerosity. DeepConvLSTM achieves similar classification performance (95.2%, 90.3%) requiring more than 100 greater Multiply and ACcumulate and Multiplication and Addition operations, which measure the networks’ complexity. The BILSTM and RCNN perform close to DeepConvLSTM while being much computationally lighter, fostering their use in embedded systems. Such lighter algorithms can be readily used in the automatic ergonomic and biomechanical risk assessment systems, enabling personalization of risk assessment and easing the adoption of safety measures in industrial practices involving MMH.


  • Open Access

    Human Body Segment Volume Estimation with Two RGB-D Cameras

    by Giulia Bassani, Emilio Maoddi, Usman Asghar, Carlo Alberto Avizzano, Alessandro Filippeschi

    In the field of human biometry, accurately estimating the volume of the whole body and its individual segments is of fundamental importance. Such measurements support a wide range of applications that include assessing health, optimizing ergonomic design, and customizing biomechanical models. In this work, we presented a Body Segment Volume Estimation (BSV) system to automatically compute whole-body and segment volumes using only two RGB-D cameras, thus limiting the system complexity. However, to maintain the accuracy comparable to 3D laser scanners, we enhanced the As-Rigid-As-Possible (ARAP) non-rigid registration techniques, disconnecting its energy from the single triangle mesh. Thus, we improved the geometrical coherence of the reconstructed mesh, especially in the lateral gap areas. We evaluated BSV starting from the RGB-D camera performances, through the results obtained with FAUST dataset human body models, and comparing with a state-of-the-art work, up to real acquisitions. It showed superior ability in accurately estimating human body volumes, and it allows evaluating volume ratios between proximal and distal body segments, which are useful indices in many clinical applications.

  • Open Access

    Design and Experimental Evaluation of Multiple 3D-Printed Reduction Gearboxes for Wearable Exoskeletons

    by Riccardo Bezzini, Giulia Bassani, Carlo Alberto Avizzano, Alessandro Filippeschi

    The recent advancements in wearable exoskeletons have highlighted their effectiveness in assisting humans for both rehabilitation and augmentation purposes. These devices interact with the user; therefore, their actuators and power transmission mechanisms are crucial for enhancing physical human–robot interaction (pHRI). The advanced progression of 3D printing technology as a valuable method for creating lightweight and efficient gearboxes enables the exploration of multiple reducer designs. However, to the authors’ knowledge, only sporadic implementations with relatively low reduction ratios have been reported, and the respective experimental validations usually vary, preventing a comprehensive evaluation of different design and implementation choices. In this paper, we design, develop, and examine experimentally multiple 3D-printed gearboxes conceived for wearable assistive devices. Two relevant transmission ratios (1:30 and 1:80) and multiple designs, which include single- and double-stage compact cam cycloidal drives, compound planetary gearboxes, and cycloidal and planetary architectures, are compared to assess the worth of 3D-printed reducers in human–robot interaction applications. The resulting prototypes were examined by evaluating their weight, cost, backdrivability, friction, regularity of the reduction ratio, gear play, and stiffness. The results show that the developed gearboxes represent valuable alternatives for actuating wearable exoskeletons in multiple applications.


  • Open Access

    Design and Experimental Evaluation of Multiple 3D-Printed Reduction Gearboxes for Wearable Exoskeletons

    by Riccardo Bezzini, Giulia Bassani, Carlo Alberto Avizzano, Alessandro Filippeschi

    The recent development of Wearable Exoskeletons has stressed their effectiveness in assisting humans for rehabilitation and augmentation purposes. These devices interact with the user, therefore their actuators and power transmission mechanisms are fundamental for improving physical Human-Robot Interaction (pHRI). The enhanced advancement of 3D-printing technology as a valuable approach for creating light and efficient gearboxes allows for exploring multiple reducers’ designs. However, to the authors’ knowledge, only sporadic implementations with relatively low reduction ratios are reported, and the respective experimental validations usually differ from each other, preventing a comprehensive evaluation of different design and implementation choices. In this paper, we design, develop, and examine experimentally multiple 3D-printed gearboxes conceived for wearable assistive devices. Two relevant transmission ratios (1:30 and 1:80) and multiple designs, that include single and double-stage compact cam cycloidal drives, compound planetary gearboxes, and the series of cycloidal and planetary architectures have been compared to assess the worth of 3D-printed reducers in Human-Robot Interaction applications. The resulting prototypes were examined by evaluating their weight, cost, back-driveability, friction, regularity of the reduction ratio, gear play, and stiffness. The results show that the developed gearboxes represent valuable alternatives for actuating wearable exoskeletons in multiple applications.


  • Open Access

    User-Centered Evaluation of the Wearable Walker Lower Limb Exoskeleton; Preliminary Assessment Based on the Experience Protocol

    by Cristian Camardella, Vittorio Lippi, Francesco Porcini, Giulia Bassani, Lucia Lencioni, Christoph Mauer, Christian Haverkamp, Carlo Alberto Avizzano, Antonio Frisoli, Alessandro Filippeschi

    Using lower limb exoskeletons provides potential advantages in terms of productivity and safety associated with reduced stress. However, complex issues in human–robot interactions are still open, such as the physiological effects of exoskeletons and the impact on the user’s subjective experience. In this work, an innovative exoskeleton, the Wearable Walker, is assessed using the EXPERIENCE benchmarking protocol from the EUROBENCH project. The Wearable Walker is a lower-limb exoskeleton that enhances human abilities, such as carrying loads. The device uses a unique control approach called Blend Control that provides smooth assistance torques. It operates two models simultaneously, one in the case in which the left foot is grounded and another for the grounded right foot. These models generate assistive torques combined to provide continuous and smooth overall assistance, preventing any abrupt changes in torque due to model switching. The EXPERIENCE protocol consists of walking on flat ground while gathering physiological signals, such as heart rate, its variability, respiration rate, and galvanic skin response, and completing a questionnaire. The test was performed with five healthy subjects. The scope of the present study is twofold: to evaluate the specific exoskeleton and its current control system to gain insight into possible improvements and to present a case study for a formal and replicable benchmarking of wearable robots.


  • Open Access

    User-centered evaluation of the Wearable Walker lower limb exoskeleton, preliminary assessment based on the Experience protocol

    by Cristian Camardella, Vittorio Lippi, Francesco Porcini, Giulia Bassani, Lucia Lencioni, Christoph Mauer, Christian Haverkamp, Carlo Alberto Avizzano, Antonio Frisoli, Alessandro Filippeschi

    Using lower-limbs exoskeletons provides potential advantages in terms of productivity and safety associated with reduced stress. However, complex issues in human-robot interaction are still open, such as the physiological effects of exoskeletons and the impact on the user's subjective experience. In this work, an innovative exoskeleton, the Wearable Walker, is assessed using the EXPERIENCE benchmarking protocol from the EUROBENCH project. The Wearable Walker is a lower-limb exoskeleton that enhances human abilities, such as carrying loads. The device uses a unique control approach called Blend Control that provides smooth assistance torques. It operates two models simultaneously, one in the case in which the left foot is grounded and another for the grounded right foot. These models generate assistive torques combined to provide continuous and smooth overall assistance, preventing any abrupt changes in torque due to model switching. The EXPERIENCE protocol consists of walking on flat ground while gathering physiological signals such as heart rate, its variability, respiration rate, and galvanic skin response and completing a questionnaire. The test was performed with five healthy subjects. The scope of the present study is twofold: to evaluate the specific exoskeleton and its current control system to gain insight into possible improvements and to present a case study for a formal and replicable benchmarking of wearable robots.