MSMichael Single

Michael Single

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael Single has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Iterative Development and Usability Evaluation of an Open-Source Rehabilitation Follow-Up Platform: User-Centered Development Study

    by Noora Emilia Angelva, Franziska Gurschler, Michael Single, Valerie Frischknecht, Dominik Näf, Noel Kampus, Eva Cioffi, Thimo Marcin, Branislav Savic, Matthias Wilhelm, et al.

    Background: Rehabilitation frequently extends beyond supervised clinical settings, creating a demand for scalable digital tools to support structured follow-up. We propose a novel open-source telerehabilitation platform. Objective: We describe the iterative, user-centered development of an open-source rehabilitation follow-up platform and report findings from an initial formative usability evaluation with patients, health care professionals, and additional end users. Methods: The platform was developed through repeated cycles of stakeholder engagement, prototyping, and evaluation within the rehabilitation department of Insel Group, University of Bern. A formative usability evaluation was conducted with 24 participants (8 health care professionals, 9 patients, and 7 additional participants; mean age 41.1, SD 12.9 y) using a task-based protocol. Perceived usability was assessed with the System Usability Scale (scored 0‐100) and the Post-Study System Usability Questionnaire (scored 1‐7; higher is better). Open-ended written responses were processed by one researcher using rapid content analysis. Results: A web-based telerehabilitation platform enables therapists to manage patient caseloads, assign and track personalized rehabilitation interventions, and monitor patient progress through Fitbit activity data and rehabilitation plan adherence. It supports multiclinic workflows with role-based access, REDCap patient importing (Vanderbilt University), automated background processing via Celery, and multilingual content. Its mean System Usability Scale score was 82.8 (SD 14.1), placing the platform in the “excellent” usability range. The mean Post-Study System Usability Questionnaire overall score was 6.02 (SD 0.77), with all 3 subscales scoring above 5.7. Most participants (20/24, 83%) rated the task set as easy or very easy; no participant rated any task as difficult. Among health care professionals, 7 out of 8 (88%) reported an intention to use the platform in practice. Qualitative themes highlighted the value of a rehabilitation plan overview, structured intervention scheduling, and progress tracking. Conclusions: The platform, released as open-source (Massachusetts Institute of Technology [MIT] License), demonstrated promising perceived usability across both patient and clinician user groups in a formative evaluation. These findings provide preliminary support for the platform’s perceived usability and justify further evaluation in real-world rehabilitation settings. Future work will evaluate deployment in real-world outpatient settings and assess clinical effectiveness.

  • Open Access

    Feasibility of Privacy-Preserving LiDAR-Based Continuous Gait and Activity Monitoring in Three People with Multiple Sclerosis: A Technical Proof-of-Concept Case Study

    by Michael Single, Sara Mollà-Casanova, Lena C. Bruhin, Vasileios Skaramagkas, Stephan M. Gerber, Andrew Chan, Tobias Nef, Iris-Katharina Penner

    Multiple sclerosis (MS) is a chronic central nervous system disease with heterogeneous symptoms, including gait disturbances and motor fatigue, affecting daily functioning and quality of life. Episodic assessments may miss within-day functional fluctuations, whereas home-like monitoring may characterize them. This technical proof-of-concept case study quantified gait parameters (velocity, step length, and variability) during natural walking, explored temporal changes in gait and activity as potentially fatigue-relevant motor-performance patterns, and examined the feasibility of deriving candidate digital measures in MS. Three individuals with MS (one EDSS 1; two EDSS 3) were monitored in an instrumented apartment for 6.5–9.0 h using three LiDAR sensors. Gait parameters, region transitions, activity patterns, EDSS, FSMC, VAS-F, and available data-yield indicators were summarized descriptively. Compared with published healthy-adult references, P01 and P03 showed lower walking velocity, and P03 showed reduced step length. P01 maintained stable gait, P02 increased afternoon walking velocity, and P03 showed an afternoon velocity decline and a smaller step length decrease. The behavioral profiles described different spatial activity patterns, and the activity levels remained low during monitoring. LiDAR-based monitoring may provide a privacy-preserving approach to capture gait and activity variations as candidate variables for future validation without establishing fatigue specificity, clinical validity, or diagnostic thresholds.

  • Open Access

    Prediction of Center-of-Mass Kinematics of Sensopro Exercises with Neural Network Models

    by Heinz Hegi, Michael Single, Tobias Nef, Ralf Kredel

    Monitoring center-of-mass is crucial for assessing postural control, but field measurements are often impractical or cost-prohibitive. This study investigates the feasibility of predicting center-of-mass kinematics from the motion of an unstable base—the Sensopro Luna—using deep learning, eliminating the need for wearable sensors. We conducted a cross-sectional study in which 64 participants were recorded performing three coordination exercises (Single-Leg Stance, Stepping, and Waves). Marker-based motion capture and auxiliary inertial sensors were used to record reference and tape kinematics. The model inputs consisted of IMU- and motion-capture-derived tape segment orientations, IMU accelerations and angular velocities, and algorithmic estimates of the lowest tape positions. Nine axis-specific exercise models were developed using a hybrid Encoder–LSTM–Decoder architecture and compared against linear regression baselines. Our results indicate that the deep learning models successfully predicted horizontal center-of-mass displacements (DNN Mean Absolute Errors of 16.1–23.7 mm for X-axis and 4.4–31.3 mm for Y-axis) and exhibited descriptively lower errors than linear models in mean absolute error and signal morphology. However, vertical predictions were less reliable, likely due to the physical constraints inherent to the kinematics of the unstable base. Error analysis revealed that prediction accuracy was highest within common postural ranges, but decreased for extreme displacements. These findings provide a proof-of-concept for wearable-free postural monitoring, particularly for movement along the mediolateral and sagittal axes. Such a system could facilitate automated, cost-effective postural feedback and performance tracking in rehabilitation and fitness environments, supporting autonomous coordination training without the practical constraints of traditional measurement systems.

  • Open Access

    Iterative Development and Usability Evaluation of an Open-Source Rehabilitation Follow-Up Platform (Preprint)

    by Noora Emilia Angelva, Franziska Gurschler, Michael Single, Valerie Frischnecht, Dominik Näf, Noel Kampus, Eva Cioffi, Thimo Marcin, Branislav Savec, Matthias Wilhelm, et al.

    BACKGROUND Rehabilitation frequently extends beyond supervised clinical settings, creating demand for scalable digital tools to support structured follow-up. We propose a novel open-source telerehabilitation platform. OBJECTIVE We describe the iterative, user-centred development of an open-source rehabilitation follow-up platform, and report findings from an initial formative usability evaluation with patients, health care professionals, and additional end users. METHODS The platform was developed through repeated cycles of stakeholder engagement, prototyping, and evaluation within the rehabilitation department of Insel Group, University Bern. A formative usability evaluation was conducted with 24 participants (8 health care professionals, 9 patients, 7 additional participants; mean age 41.1 years, SD 12.9) using a task-based protocol. Perceived usability was assessed with the System Usability Scale (scored 0--100) and the Post-Study System Usability Questionnaire (scored 1--7; higher is better). Open-ended written responses were processed by one researcher using rapid content analysis. RESULTS A web-based telerehabilitation platform that enables therapists to manage patient caseloads, assign and track personalised rehabilitation interventions, and monitor patient progress through Fitbit activity data, and rehabilitation plan adherence. It supports multi-clinic workflows with role-based access, REDCap patient importing, automated background processing via Celery, and multilingual content. Its mean System Usability Scale score was 82.8 (SD 14.1), placing the platform in the ``excellent'' usability range. Mean Post-Study System Usability Questionnaire overall score was 6.02 (SD 0.77), with all three subscales scoring above 5.7. Most participants (20/24, 83\%) rated the task set as easy or very easy; no participant rated any task as difficult. Among health care professionals, 7/8 (88\%) reported intention to use the platform in practice. Qualitative themes highlighted the value of rehabilitation plan overview, structured intervention scheduling, and progress tracking. CONCLUSIONS The platform, released as open-source (MIT license), demonstrated promising perceived usability across both patient and clinician user groups in a formative evaluation. these findings provide preliminary support for the perceived usability of the platform and justify further evaluation in real-world rehabilitation settings. Future work will evaluate deployment in real-world outpatient settings and assess clinical effectiveness.

  • Applying German word vectors to assess flexibility performance in the associative fluency task.

    by Magdalena Camenzind, Michael Single, Stephan M. Gerber, Tobias Nef, Claudio L. Bassetti, René M. Müri, Aleksandra K. Eberhard-Moscicka


  • Open Access

    Smartphone-Based Auditory Motion Stimulation for Hemispatial Neglect: Development and Usability Study

    by Tobias Nef, Nora Geiser, Brigitte C Kaufmann, Noora Emilia Angelva, Nic Krummenacher, Michael Single, Dario Cazzoli, Thomas Nyffeler

    Background: Hemispatial neglect affects approximately 33% of patients after acute stroke and is linked to poor recovery. Auditory motion stimulation, particularly using spatial cues, can enhance spatial awareness and has shown promise in experimental settings. Objective: This study aimed to develop and evaluate Neglect Radio, a smartphone app that delivers auditory motion stimulation, focusing on sound realism and usability in healthy volunteers. Methods: Two auditory motion rendering methods, dynamic stereo volume control and standardized head-related transfer functions (HRTFs), were implemented in a mobile app streaming public radio content. In an online study, 37 healthy volunteers rated spatial realism (0-100 scale) of 5 audio sources in 3 conditions: static stereo, volume control motion, and HRTF-based motion. Independent samples 1-tailed t tests compared realism scores. Ten participants tested the app for 15 minutes and completed the System Usability Scale (SUS). Results: HRTF-based audio was rated as being significantly more realistic than volume control (t72=3.722; P<.001), and both motion conditions scored significantly higher than static stereo. The mean SUS score was 86.5 (SD 6.9), exceeding the 68-point threshold for above-average usability and a rating of “excellent.” Conclusions: Neglect Radio successfully produced realistic spatial auditory motion and achieved excellent usability ratings in healthy participants. This smartphone-based platform is scalable, accessible, and engaging, with potential to complement hemispatial neglect rehabilitation. However, clinical efficacy in stroke patients with hemispatial neglect has not yet been evaluated and requires confirmation in controlled trials.


  • Open Access

    Smartphone-Based Auditory Motion Stimulation for Hemispatial Neglect: Development and Usability Study (Preprint)

    by Tobias Nef, Nora Geiser, Brigitte C Kaufmann, Noora Emilia Angelva, Nic Krummenacher, Michael Single, Dario Cazzoli, Thomas Nyffeler

    BACKGROUND Hemispatial neglect affects approximately 33% of patients after acute stroke and is linked to poor recovery. Auditory motion stimulation, particularly using spatial cues, can enhance spatial awareness and has shown promise in experimental settings. OBJECTIVE This study aimed to develop and evaluate Neglect Radio, a smartphone app that delivers auditory motion stimulation, focusing on sound realism and usability in healthy volunteers. METHODS Two auditory motion rendering methods, dynamic stereo volume control and standardized head-related transfer functions (HRTFs), were implemented in a mobile app streaming public radio content. In an online study, 37 healthy volunteers rated spatial realism (0-100 scale) of 5 audio sources in 3 conditions: static stereo, volume control motion, and HRTF-based motion. Independent samples 1-tailed t tests compared realism scores. Ten participants tested the app for 15 minutes and completed the System Usability Scale (SUS). RESULTS HRTF-based audio was rated as being significantly more realistic than volume control (t72=3.722; P<.001), and both motion conditions scored significantly higher than static stereo. The mean SUS score was 86.5 (SD 6.9), exceeding the 68-point threshold for above-average usability and a rating of “excellent.” CONCLUSIONS Neglect Radio successfully produced realistic spatial auditory motion and achieved excellent usability ratings in healthy participants. This smartphone-based platform is scalable, accessible, and engaging, with potential to complement hemispatial neglect rehabilitation. However, clinical efficacy in stroke patients with hemispatial neglect has not yet been evaluated and requires confirmation in controlled trials. CLINICALTRIAL

  • Open Access

    A Usability Pilot Study of a Sensor-Guided Interactive System for Dexterity Training in Parkinson’s Disease

    by Nic Krummenacher, Stephan M. Gerber, Manuela Pastore-Wapp, Michael Single, Stephan Bohlhalter, Tobias Nef, Tim Vanbellingen

    This pilot study aimed to evaluate the usability of a new, feedback-based dexterity training system in people with Parkinson’s disease (PwPD) and healthy adults. Seven PwPD and seven healthy adults participated in the study. The System Usability Scale (SUS) and the Post-Study System Usability Questionnaire Version 3 (PSSUQ) were used to assess usability. Additionally, the feedback shown as a counter, detected through newly developed algorithms, was evaluated by comparing the device-detected repetitions during six exercises to those counted by a supervisor. High median SUS scores of 92.5 were obtained in both PwPD (IQR = 81.25–98.75) and healthy adults (IQR = 87.5–93.75, maximum score 100, minimum score 0). Similarly, high PSSUQ median scores were achieved after the session (1.14, IQR = 1.00–1.33, PD; 1.08, IQR = 1.00–1.58, healthy adults, maximum score 1, minimum score 7). PwPD completed 648 repetitions, with 551 (85%) correctly recognized by the system. For healthy adults, 883 out of 913 (97%) repetitions were classified as right. The present study showed high usability and high perceived user satisfaction for the new training system in all study participants. The system effectively detects exercise repetition rates but requires further refinement to enhance accuracy for specific pinch grip exercises.

  • Open Access

    Unobtrusive measurement of gait parameters using seismographs: An observational study

    by Michael Single, Lena C. Bruhin, Aileen C. Naef, Paul Krack, Tobias Nef, Stephan M. Gerber

    Analyzing irregularities in walking patterns helps detect human locomotion abnormalities that can signal health changes. Traditional observation-based assessments have limitations due to subjective biases and capture only a single time point. Ambient and wearable sensor technologies allow continuous and objective locomotion monitoring but face challenges due to the need for specialized expertise and user compliance. This work proposes a seismograph-based algorithm for quantifying human gait, incorporating a step extraction algorithm derived from mathematical morphologies, with the goal of achieving the accuracy of clinical reference systems. To evaluate our method, we compared the gait parameters of 50 healthy participants, as recorded by seismographs, and those obtained from reference systems (a pressure-sensitive walkway and a camera system). Participants performed four walking tests, including traversing a walkway and completing the timed up-and-go (TUG) test. In our findings, we observed linear relationships with strong positive correlations (R2 > 0.9) and tight 95% confidence intervals for all gait parameters (step time, cycle time, ambulation time, and cadence). We demonstrated that clinical gait parameters and TUG mobility test timings can be accurately derived from seismographic signals, with our method exhibiting no significant differences from established clinical reference systems.


  • Open Access

    A Transferable Lidar-Based Method to Conduct Contactless Assessments of Gait Parameters in Diverse Home-like Environments

    by Michael Single, Lena C. Bruhin, Aaron Colombo, Kevin Möri, Stephan M. Gerber, Jacob Lahr, Paul Krack, Stefan Klöppel, René M. Müri, Urs P. Mosimann, et al.

    Gait abnormalities in older adults are linked to increased risks of falls, institutionalization, and mortality, necessitating accurate and frequent gait assessments beyond traditional clinical settings. Current methods, such as pressure-sensitive walkways, often lack the continuous natural environment monitoring needed to understand an individual’s gait fully during their daily activities. To address this gap, we present a Lidar-based method capable of unobtrusively and continuously tracking human leg movements in diverse home-like environments, aiming to match the accuracy of a clinical reference measurement system. We developed a calibration-free step extraction algorithm based on mathematical morphology to realize Lidar-based gait analysis. Clinical gait parameters of 45 healthy individuals were measured using Lidar and reference systems (a pressure-sensitive walkway and a video recording system). Each participant participated in three predefined ambulation experiments by walking over the walkway. We observed linear relationships with strong positive correlations (R2>0.9) between the values of the gait parameters (step and stride length, step and stride time, cadence, and velocity) measured with the Lidar sensors and the pressure-sensitive walkway reference system. Moreover, the lower and upper 95% confidence intervals of all gait parameters were tight. The proposed algorithm can accurately derive gait parameters from Lidar data captured in home-like environments, with a performance not significantly less accurate than clinical reference systems.