Jorge Camacho-Espino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jorge Camacho-Espino has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Graciliano Nicolás Marichal
Higher Polytechnic School of Engineering (EPSI), University of La Laguna, 38001 Tenerife, Spain
3 shared publications - Baltasar Peñate
Water Department, Canary Islands Institute of Technology (ITC), 35119 Santa Lucía, Spain
2 shared publications - Antonio Marrero-Domínguez
Department of Agricultural and Rural Engineering, (EPSI), University of La Laguna, Santa Cruz de Tenerife, Spain
1 shared publication - Deivis Avila
Escuela Politécnica Superior de Ingeniería, Universidad de La Laguna (ULL), Avenida Ángel Guimerá Jorge, s/n. 456-38200, 38200 Santa Cruz de Tenerife, Tenerife, Spain
1 shared publication - Domingo Felix Sáenz Pisaca
Department of Agricultural and Rural Engineering, (EPSI), University of La Laguna, Santa Cruz de Tenerife, Spain
1 shared publication - Evangelos Dimitriou
Department of Natural Resources Management and Agricultural Engineering, Agricultural University of Athens, 75 Iera Odos Street, 11855 Athens, Greece
1 shared publication
Latest Publications
- Open Access
- 4 April 2025
- Published by Elsevier in Desalination and Water Treatment
- Vol. 322
Experimental investigation of the performance of a seawater Reverse Osmosis spiral wound membrane under variable feed water temperature
- 4 April 2025
- Published by Elsevier in Desalination and Water Treatment
- Vol. 322
Open AccessExperimental investigation of the performance of a seawater Reverse Osmosis spiral wound membrane under variable feed water temperature
- Open Access
- 7 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (6) , 3392
Energy Efficiency Optimization in Onboard SWRO Desalination Plants Based on a Genetic Neuro-Fuzzy System
This work presents a novel intelligent control system based on a Genetic Neuro-Fuzzy tool to optimize and improve the performance of a seawater reverse osmosis desalination plant (SWRO) on board a marine vessel. This investigation pays special attention to minimizing energy consumption to improve the energy efficiency of this marine installation. The system analyzes measurements of different variables—seawater pH, seawater conductivity, permeate flow rate, permeate conductivity, and total energy consumed—in order to provide the most appropriate value of permeate flow rate control and operating pressure of the high-pressure pump (HPP). This intelligent method allows the plant to achieve output values nearer to the desired setpoints set by the plant operators.
- 7 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (6) , 3392
Open AccessEnergy Efficiency Optimization in Onboard SWRO Desalination Plants Based on a Genetic Neuro-Fuzzy System
This work presents a novel intelligent control system based on a Genetic Neuro-Fuzzy tool to optimize and improve the performance of a seawater reverse osmosis desalination plant (SWRO) on board a marine vessel. This investigation pays special attention to minimizing energy consumption to improve the energy efficiency of this marine installation. The system analyzes measurements of different variables—seawater pH, seawater conductivity, permeate flow rate, permeate conductivity, and total energy consumed—in order to provide the most appropriate value of permeate flow rate control and operating pressure of the high-pressure pump (HPP). This intelligent method allows the plant to achieve output values nearer to the desired setpoints set by the plant operators.
- Open Access
Machine Learning Models Applied to Manage the Operation of a Simple SWRO Desalination Plant and Its Application in Marine Vessels
In this work, two machine learning techniques, specifically decision trees (DTs) and support vector machines (SVMs), were applied to optimize the performance of a seawater reverse osmosis (SWRO) desalination plant with a capacity of 100 m3 per day. The input variables to the system were seawater pH, seawater conductivity, and three requirements: permeate flow rate, permeate conductivity, and total energy consumed by the desalination plant. These requirements were decided based on a cost function that prioritizes the water needs in a vessel and the maximum possible energy savings. The intelligent system modifies the actuators of the plant: feed flow rate control and high-pressure pump (HPP) operating pressure. This tool is proposed for the optimal use of desalination plants in marine vessels. Although both machine learning techniques output satisfactory results, it was concluded that the DTs technique (HPP pressure: root mean square error (RMSE) = 0.0104; feed flow rate: RMSE = 0.0196) is more accurate than SVMs (HPP pressure: RMSE = 0.0918; feed flow rate: RMSE = 0.0198) based on the metrics used. The final objective of the paper is to extrapolate the implementation of this smart system to other shipboard desalination plants and optimize their performance.
Open AccessMachine Learning Models Applied to Manage the Operation of a Simple SWRO Desalination Plant and Its Application in Marine Vessels
In this work, two machine learning techniques, specifically decision trees (DTs) and support vector machines (SVMs), were applied to optimize the performance of a seawater reverse osmosis (SWRO) desalination plant with a capacity of 100 m3 per day. The input variables to the system were seawater pH, seawater conductivity, and three requirements: permeate flow rate, permeate conductivity, and total energy consumed by the desalination plant. These requirements were decided based on a cost function that prioritizes the water needs in a vessel and the maximum possible energy savings. The intelligent system modifies the actuators of the plant: feed flow rate control and high-pressure pump (HPP) operating pressure. This tool is proposed for the optimal use of desalination plants in marine vessels. Although both machine learning techniques output satisfactory results, it was concluded that the DTs technique (HPP pressure: root mean square error (RMSE) = 0.0104; feed flow rate: RMSE = 0.0196) is more accurate than SVMs (HPP pressure: RMSE = 0.0918; feed flow rate: RMSE = 0.0198) based on the metrics used. The final objective of the paper is to extrapolate the implementation of this smart system to other shipboard desalination plants and optimize their performance.