MPMariana N. São Pedro

Mariana N. São Pedro

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mariana N. São Pedro has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Real‐time detection of mAb aggregates in an integrated downstream process

    by Mariana N. São Pedro, Madelène Isaksson, Joaquín Gomis‐Fons, Michel H. M. Eppink, Bernt Nilsson, Marcel Ottens

    The implementation of continuous processing in the biopharmaceutical industry is hindered by the scarcity of process analytical technologies (PAT). To monitor and control a continuous process, PAT tools will be crucial to measure real‐time product quality attributes such as protein aggregation. Miniaturizing these analytical techniques can increase measurement speed and enable faster decision‐making. A fluorescent dye (FD)‐based miniaturized sensor has previously been developed: a zigzag microchannel which mixes two streams under 30 s. Bis‐ANS and CCVJ, two established FDs, were employed in this micromixer to detect aggregation of the biopharmaceutical monoclonal antibody (mAb). Both FDs were able to robustly detect aggregation levels starting at 2.5%. However, the real‐time measurement provided by the microfluidic sensor still needs to be implemented and assessed in an integrated continuous downstream process. In this work, the micromixer is implemented in a lab‐scale integrated system for the purification of mAbs, established in an ÄKTA™ unit. A viral inactivation and two polishing steps were reproduced, sending a sample of the product pool after each phase directly to the microfluidic sensor for aggregate detection. An additional UV sensor was connected after the micromixer and an increase in its signal would indicate that aggregates were present in the sample. The at‐line miniaturized PAT tool provides a fast aggregation measurement, under 10 min, enabling better process understanding and control.


  • Open Access

    Application of a fluorescent dye‐based microfluidic sensor for real‐time detection of mAb aggregates

    by Mariana N. São Pedro, Michel H. M. Eppink, Marcel Ottens

    The lack of process analytical technologies able to provide real‐time information and process control over a biopharmaceutical process has long impaired the transition to continuous biomanufacturing. For the monoclonal antibody (mAb) production, aggregate formation is a major critical quality attribute (CQA) with several known process parameters (i.e., protein concentration and agitation) influencing this phenomenon. The development of a real‐time tool to monitor aggregate formation is then crucial to gain control and achieve a continuous processing. Due to an inherent short operation time, miniaturized biosensors placed after each step can be a powerful solution. In this work, the development of a fluorescent dye‐based microfluidic sensor for fast at‐line PAT is described, using fluorescent dyes to examine possible mAb size differences. A zigzag microchannel, which provides 90% of mixing efficiency under 30 s, coupled to an UV–Vis detector, and using four FDs, was studied and validated. With different generated mAb aggregation samples, the FDs Bis‐ANS and CCVJ were able to robustly detect from, at least, 2.5% to 10% of aggregation. The proposed FD‐based micromixer is then ultimately implemented and validated in a lab‐scale purification system, demonstrating the potential of a miniaturized biosensor to speed up CQAs measurement in a continuous process.


  • Open Access

    Design of a microfluidic mixer channel: First steps into creating a fluorescent dye‐based biosensor for mAb aggregate detection

    by Mariana N. São Pedro, Mafalda S. Santos, Michel H. M. Eppink, Marcel Ottens

    A major challenge in the transition to continuous biomanufacturing is the lack of process analytical technology (PAT) tools which are able to collect real‐time information on the process and elicit a response to facilitate control. One of the critical quality attributes (CQAs) of interest during monoclonal antibodies production is aggregate formation. The development of a real‐time PAT tool to monitor aggregate formation is then crucial to have immediate feedback and process control. Miniaturized sensors placed after each unit operation can be a powerful solution to speed up an analytical measurement due to their characteristic short reaction time. In this work, a micromixer structure capable of mixing two streams is presented, to be employed in the detection of mAb aggregates using fluorescent dyes. Computational fluid dynamics (CFD) simulations were used to compare the mixing performance of a series of the proposed designs. A final design of a zigzag microchannel with 45° angle was reached and this structure was subsequently fabricated and experimentally validated with colour dyes and, later, with a FITC‐IgG molecule. The designed zigzag micromixer presents a mixing index of around 90%, obtained in less than 30 seconds. Therefore, a micromixer channel capable of a fast and efficient mixing is hereby demonstrated, to be used as a real‐time PAT tool for a fluorescence based detection of protein aggregation.


  • Open Access

    Process analytical technique (PAT) miniaturization for monoclonal antibody aggregate detection in continuous downstream processing

    by Mariana N. São Pedro, Marieke E Klijn, Michel H.M. Eppink, Marcel Ottens

    The transition to continuous biomanufacturing is considered the next step to reduce costs and improve process robustness in the biopharmaceutical industry, while also improving productivity and product quality. The platform production process for monoclonal antibodies (mAbs) is eligible for continuous processing to lower manufacturing costs due to patent expiration and subsequent growing competition. One of the critical quality attributes of interest during mAb purification is aggregate formation, with several processing parameters and environmental factors known to influence antibody aggregation. Therefore, a real‐time measurement to monitor aggregate formation is crucial to have immediate feedback and process control and to achieve a continuous downstream processing. Miniaturized biosensors as an in‐line process analytical technology tool could play a pivotal role to facilitate the transition to continuous manufacturing. In this review, miniaturization of already well‐established methods to detect protein aggregation, such as dynamic light scattering, Raman spectroscopy and circular dichroism, will be extensively evaluated for the possibility of providing a real‐time measurement of mAb aggregation. The method evaluation presented in this review shows which limitations of each analytical method still need to be addressed and provides application examples of each technique for mAb aggregate characterization. Additionally, challenges related to miniaturization are also addressed, such as the design of the microfluidic chip and the microfabrication material. The evaluation provided in this review shows why the development of microfluidic biosensors is considered the key for real‐time measurement of mAb aggregates and how it can contribute to the transition to a continuous processing. © 2021 The Authors. Journal of Chemical Technology and Biotechnology published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry (SCI).