BSBohumil Skala

Bohumil Skala

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bohumil Skala has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and Validation of Segmented CFRP Lamella-Based Composite End Shield for Bearing Current Mitigation

    by Jiří Sika, Michal Křížek, Tomáš Kavalír, Bohumil Skala

    This study addresses the premature failure of electric motor bearings caused by inverter-induced parasitic currents. We propose a novel segmented end shield design utilizing 24 carbon fiber-reinforced polymer (CFRP) lamellae to provide both structural support and galvanic isolation. The “main working” of the design relies on a segmented architecture where the lamellae are adhesively bonded between a central bearing housing and an outer mounting flange, creating a high-impedance path that interrupts circulating currents. Experimental validation focused on both mechanical stability and dielectric performance. Results indicate that the assembly maintains rotor positional integrity under nominal loads while providing an insulation resistance > 1 GΩ at 1 kV and a structural capacitance of 2.47 nF. These parameters effectively mitigate low-frequency circulating currents. Data analysis, derived from the mean values of repeated test cycles, confirms that the composite architecture serves as a viable, mechanically robust alternative to conventional metallic end shields.

  • Open Access

    Dynamic wireless power transfer in E-mobility using AC power bus and matrix converter: implementation suitability study

    by Martin Zavrel, Vladimir Kindl, Michal Frivaldsky, Bohumil Skala

    Presented paper discusses power distribution bus of dynamic wireless charging track for e-mobility applications. The focus is applied to the matrix converter and AC power distribution bus adaptation. The key behavior of matrix one-to-one phase converter and three-to-one phase converter is presented to get topologies for adaptation. Get matrix converter features are discussed regarding to the wireless power transfer and dynamic charging in electromobility. Feasibility of power topologies and control approaches are discussed as well. Proposed dynamic charging using three-phase matrix converter adaptation is compared to the conventional topologies using DC power distribution bus and corresponding inverters topologies. Knowledge taken from literature and theoretical discussion is verified by MATLAB–Simulink simulations and by basic experiments. Finally, feasibility study decisions are made in conclusion.


  • Open Access

    Effect of open phase condition on asynchronous machine

    by Bohumil Skala, Vladimir Kindl, Michal Frivaldsky, Lukas Sobotka, Martin Zavrel

    This paper investigates the influence of an asymmetrical power supply on induction machines, focusing on key parameters such as temperature rise, torque, efficiency, and power factor. Various three-phase voltage asymmetries are examined to determine their impact on the magnitude of the negative-sequence voltage component. The study further explores how a drop in phase voltage leads to a significant negative component, the effect of phasor rotation from its ideal position, and the number of phases subject to voltage drops or phase shift errors. A voltage synthesis approach is employed to analyse the roles of the positive and negative components, with one component held constant to evaluate the resulting changes in power factor, efficiency, and torque. In addition, a dynamic thermal model is implemented to assess the machine’s temperature rise under load conditions.

  • Open Access

    Complex Design Method of Filtration Station Considering Harmonic Components

    by Vaclav Kus, Bohumil Skala, Pavel Drabek

    The paper deals with a new methodology for calculating the filter parameters. The basis is respect for the fact that the real filter current consists of other harmonic components, which filter is tuned. The proposed methodology was used to design filters for traction substation 25 kV/50 Hz. The operation of the locomotives in the AC supply systems of 25 kV/50 Hz leads to a rising of higher order harmonic currents. Due to the 1-phase supply system, these are mainly the 3rd and 5th harmonics. By simulation and subsequent measurement of the proposed traction power station filters the proposed methodology was verified. Thus, the filter design can also be used for filter compensating stations of the standard 3-phase distribution network. The described method presents an optimal filter design without unnecessary oversizing. This fact reduces the size and cost of the filter. It is shown that it is possible to design a filter that meets the requirements for power quality under extreme load and to minimise distortion of line voltage.


  • Open Access

    TRANSIENT THERMAL ANALYSIS OF SMALL SQUIRREL CAGE MOTOR THROUGH COUPLED FEA

    by Roman Pechanek, Vladimir Kindl, Bohumil Skala