Marco Rocca
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marco Rocca has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Emmanuel Delamarche
IBM Research Europe—Zurich Säumerstrasse 4 CH-8803 Rüschlikon Zurich Switzerland
3 shared publications Marie L. Salva
IBM Research Europe—Zurich Säumerstrasse 4 CH-8803 Rüschlikon Zurich Switzerland
3 shared publications- Christof M. Niemeyer
Karlsruhe Institute of Technology
2 shared publications Maxime Dufresne
IBM Research Europe—Zurich Säumerstrasse 4 CH-8803 Rüschlikon Zurich Switzerland
2 shared publicationsChristof M. Niemeyer
Institute of Biological Interfaces (IBG1) Karlsruhe Institute of Technology Hermann-von-Helmholtz-Platz 1 76344 Eggenstein-Leopoldshafen Germany
1 shared publicationSamuel Castonguay
Department of Engineering Physics, Polytechnique Montreal, Montreal, Quebec, Canada
1 shared publication
Latest Publications
- Open Access
- 30 August 2021
- Published by Wiley in Angewandte Chemie
- Vol. 133 (45) , 24266-24271
Microscale Interfacial Polymerization on a Chip
Forming hydrogels with precise geometries is challenging and mostly done using photopolymerization, which involves toxic chemicals, rinsing steps, solvents, and bulky optical equipment. Here, we introduce a new method for in situ formation of hydrogels with a well‐defined geometry in a sealed microfluidic chip by interfacial polymerization. The geometry of the hydrogel is programmed by microfluidic design using capillary pinning structures and bringing into contact solutions containing hydrogel precursors from vicinal channels. The characteristics of the hydrogel (mesh size, molecular weight cut‐off) can be readily adjusted. This method is compatible with capillary‐driven microfluidics, fast, uses small volumes of reagents and samples, and does not require specific laboratory equipment. Our approach creates opportunities for filtration, hydrogel functionalization, and hydrogel‐based assays, as exemplified by a rapid, compact competitive immunoassay that does not require a rinsing step.
- 30 August 2021
- Published by Wiley in Angewandte Chemie
- Vol. 133 (45) , 24266-24271
Open AccessMicroscale Interfacial Polymerization on a Chip
Forming hydrogels with precise geometries is challenging and mostly done using photopolymerization, which involves toxic chemicals, rinsing steps, solvents, and bulky optical equipment. Here, we introduce a new method for in situ formation of hydrogels with a well‐defined geometry in a sealed microfluidic chip by interfacial polymerization. The geometry of the hydrogel is programmed by microfluidic design using capillary pinning structures and bringing into contact solutions containing hydrogel precursors from vicinal channels. The characteristics of the hydrogel (mesh size, molecular weight cut‐off) can be readily adjusted. This method is compatible with capillary‐driven microfluidics, fast, uses small volumes of reagents and samples, and does not require specific laboratory equipment. Our approach creates opportunities for filtration, hydrogel functionalization, and hydrogel‐based assays, as exemplified by a rapid, compact competitive immunoassay that does not require a rinsing step.
- Open Access
- 30 August 2021
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 60 (45) , 24064-24069
Microscale Interfacial Polymerization on a Chip
Forming hydrogels with precise geometries is challenging and mostly done using photopolymerization, which involves toxic chemicals, rinsing steps, solvents, and bulky optical equipment. Here, we introduce a new method for in situ formation of hydrogels with a well‐defined geometry in a sealed microfluidic chip by interfacial polymerization. The geometry of the hydrogel is programmed by microfluidic design using capillary pinning structures and bringing into contact solutions containing hydrogel precursors from vicinal channels. The characteristics of the hydrogel (mesh size, molecular weight cut‐off) can be readily adjusted. This method is compatible with capillary‐driven microfluidics, fast, uses small volumes of reagents and samples, and does not require specific laboratory equipment. Our approach creates opportunities for filtration, hydrogel functionalization, and hydrogel‐based assays, as exemplified by a rapid, compact competitive immunoassay that does not require a rinsing step.
- 30 August 2021
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 60 (45) , 24064-24069
Open AccessMicroscale Interfacial Polymerization on a Chip
Forming hydrogels with precise geometries is challenging and mostly done using photopolymerization, which involves toxic chemicals, rinsing steps, solvents, and bulky optical equipment. Here, we introduce a new method for in situ formation of hydrogels with a well‐defined geometry in a sealed microfluidic chip by interfacial polymerization. The geometry of the hydrogel is programmed by microfluidic design using capillary pinning structures and bringing into contact solutions containing hydrogel precursors from vicinal channels. The characteristics of the hydrogel (mesh size, molecular weight cut‐off) can be readily adjusted. This method is compatible with capillary‐driven microfluidics, fast, uses small volumes of reagents and samples, and does not require specific laboratory equipment. Our approach creates opportunities for filtration, hydrogel functionalization, and hydrogel‐based assays, as exemplified by a rapid, compact competitive immunoassay that does not require a rinsing step.
- Open Access
- 27 July 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (18) , 3573-3582
Rapid quantitative assays for glucose-6-phosphate dehydrogenase (G6PD) and hemoglobin combined on a capillary-driven microfluidic chip
Rapid tests for glucose-6-phosphate dehydrogenase (G6PD) are extremely important for determining G6PD deficiency, a widespread metabolic disorder which triggers hemolytic anemia in response to primaquine and tafenoquine medication, the most effective drugs for the radical cure of malaria caused by Plasmodium parasites. Current point-of-care diagnostic devices for G6PD are either qualitative, do not normalize G6PD activity to the hemoglobin concentration, or are very expensive. In this work we developed a capillary-driven microfluidic chip to perform a quantitative G6PD test and a hemoglobin measurement within 2 minutes and using less than 2 μL of sample. We used a powerful microfluidic module to integrate and resuspend locally the reagents needed for the G6PD assay and controls. We also developed a theoretical model that successfully predicts the enzymatic reactions on-chip, guides on-chip reagent spotting and allows efficient integration of multiple assays in miniaturized formats with only a few nanograms of reagents.
- 27 July 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (18) , 3573-3582
Open AccessRapid quantitative assays for glucose-6-phosphate dehydrogenase (G6PD) and hemoglobin combined on a capillary-driven microfluidic chip
Rapid tests for glucose-6-phosphate dehydrogenase (G6PD) are extremely important for determining G6PD deficiency, a widespread metabolic disorder which triggers hemolytic anemia in response to primaquine and tafenoquine medication, the most effective drugs for the radical cure of malaria caused by Plasmodium parasites. Current point-of-care diagnostic devices for G6PD are either qualitative, do not normalize G6PD activity to the hemoglobin concentration, or are very expensive. In this work we developed a capillary-driven microfluidic chip to perform a quantitative G6PD test and a hemoglobin measurement within 2 minutes and using less than 2 μL of sample. We used a powerful microfluidic module to integrate and resuspend locally the reagents needed for the G6PD assay and controls. We also developed a theoretical model that successfully predicts the enzymatic reactions on-chip, guides on-chip reagent spotting and allows efficient integration of multiple assays in miniaturized formats with only a few nanograms of reagents.