Humberto S. Sanchez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Humberto S. Sanchez has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Connie B. Chang
Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota, United States of America
2 shared publications - Aaron S. Brewster
Lawrence Berkeley National Laboratory
1 shared publication - Aina E. Cohen
Stanford Synchrotron Radiation Lightsource; Menlo Park, CA 94025, USA
1 shared publication - Artem Lyubimov
Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
1 shared publication - Asmit Bhowmick
Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, USA
1 shared publication - Barkan Sidar
Department of Chemical and Biological Engineering, Montana State University, Bozeman, MT, United States of America
1 shared publication
Latest Publications
- Open Access
Structure of active methyl-CoM reductase, Earth’s main methane producer
Summary: Our work reveals the structure of the active state of Methyl-Coenzyme M Reductase (MCR), the key and rate-limiting enzyme in biological methane formation. We find large differences between the active Ni(I) and inactive Ni(II) proteins and provide insight into how nature makes and breaks the C-H bond of methane. The Ni(II)-F430 center in inactive MCR contains four planar nitrogen ligands, a lower axial glutamine oxo, and an upper axial thiolate. The Ni(I)-enzyme replaces the axial ligands with a single water. The one-electron redox change results in movement of the Ni ion and upward swing of the β-lactam ring in the tetrapyrrole coupled to a domino-like protein quake through second sphere residues, inter-subunit interactions, a substrate tunnel, affecting even the dimensions of the unit cell. These structural changes lead Ni(I)-MCR to release a charge clamp that, in the Ni(II) state, locks down substrate Coenzyme B. Determining the Ni(I)-MCR structure required development of rigorous anaerobic crystallographic techniques. Validation of the MCR redox state was accomplished by in-line and parallel spectroscopic and unit cell analyses. This structure has large implications for developing technologies to limit methane emissions and efficiently produce biofuels. Methodology described here will enhance structural biology for other oxygen-sensitive enzymes.
Open AccessStructure of active methyl-CoM reductase, Earth’s main methane producer
Summary: Our work reveals the structure of the active state of Methyl-Coenzyme M Reductase (MCR), the key and rate-limiting enzyme in biological methane formation. We find large differences between the active Ni(I) and inactive Ni(II) proteins and provide insight into how nature makes and breaks the C-H bond of methane. The Ni(II)-F430 center in inactive MCR contains four planar nitrogen ligands, a lower axial glutamine oxo, and an upper axial thiolate. The Ni(I)-enzyme replaces the axial ligands with a single water. The one-electron redox change results in movement of the Ni ion and upward swing of the β-lactam ring in the tetrapyrrole coupled to a domino-like protein quake through second sphere residues, inter-subunit interactions, a substrate tunnel, affecting even the dimensions of the unit cell. These structural changes lead Ni(I)-MCR to release a charge clamp that, in the Ni(II) state, locks down substrate Coenzyme B. Determining the Ni(I)-MCR structure required development of rigorous anaerobic crystallographic techniques. Validation of the MCR redox state was accomplished by in-line and parallel spectroscopic and unit cell analyses. This structure has large implications for developing technologies to limit methane emissions and efficiently produce biofuels. Methodology described here will enhance structural biology for other oxygen-sensitive enzymes.
- Open Access
- 12 July 2023
- Published by IOP Publishing in Engineering Research Express
- Vol. 5 (3) , 035014
Open-source pneumatic pressure pump for drop-based microfluidic flow controls
An open-source pneumatic pressure pump is engineered for driving fluid flow in a microfluidic device. It is designed to be a cost-effective and customizable alternative to commercial systems. The pneumatic pressure pump utilizes a single open-source microcontroller to control four dual-valve pressure regulators. The control scheme is written in the Arduino development environment and the user interface is written in Python. The pump was used to pressurize water and a fluorinated oil that have similar viscosities. The pump can accurately control pressures to a resolution of less than 0.02 psig with rapid response times of less than one second, overshoot of desired pressures by less than 30%, and setting response times of less than two seconds. The pump was also validated in its ability to produce water-in-oil drops using a drop-making microfluidic device. The resultant drop size scaled as expected with the pressures applied to the emulsion phases. The pump is the first custom-made dual-valve regulator that is used to precisely control fluid flow in a microfluidic device. The presented design is an advancement towards making more fully open-source pneumatic pressure pumps for controlling flow in microfluidic devices.
- 12 July 2023
- Published by IOP Publishing in Engineering Research Express
- Vol. 5 (3) , 035014
Open AccessOpen-source pneumatic pressure pump for drop-based microfluidic flow controls
An open-source pneumatic pressure pump is engineered for driving fluid flow in a microfluidic device. It is designed to be a cost-effective and customizable alternative to commercial systems. The pneumatic pressure pump utilizes a single open-source microcontroller to control four dual-valve pressure regulators. The control scheme is written in the Arduino development environment and the user interface is written in Python. The pump was used to pressurize water and a fluorinated oil that have similar viscosities. The pump can accurately control pressures to a resolution of less than 0.02 psig with rapid response times of less than one second, overshoot of desired pressures by less than 30%, and setting response times of less than two seconds. The pump was also validated in its ability to produce water-in-oil drops using a drop-making microfluidic device. The resultant drop size scaled as expected with the pressures applied to the emulsion phases. The pump is the first custom-made dual-valve regulator that is used to precisely control fluid flow in a microfluidic device. The presented design is an advancement towards making more fully open-source pneumatic pressure pumps for controlling flow in microfluidic devices.
- 8 June 2022
- Published by IOP Publishing in Biomedical Materials
- Vol. 17 (4) , 045020
Granular Matrigel: restructuring a trusted extracellular matrix material for improved permeability
Matrigel is a polymeric extracellular matrix material produced by mouse cancer cells. Over the past four decades, Matrigel has been shown to support a wide variety of two- and three-dimensional cell and tissue culture applications including organoids. Despite widespread use, transport of molecules, cells, and colloidal particles through Matrigel can be limited. These limitations restrict cell growth, viability, and function and limit Matrigel applications. A strategy to improve transport through a hydrogel without modifying the chemistry or composition of the gel is to physically restructure the material into microscopic microgels and then pack them together to form a porous material. These ‘granular’ hydrogels have been created using a variety of synthetic hydrogels, but granular hydrogels composed of Matrigel have not yet been reported. Here we present a drop-based microfluidics approach for structuring Matrigel into a three-dimensional, mesoporous material composed of packed Matrigel microgels, which we call granular Matrigel. We show that restructuring Matrigel in this manner enhances the transport of colloidal particles and human dendritic cells (DCs) through the gel while providing sufficient mechanical support for culture of human gastric organoids (HGOs) and co-culture of human DCs with HGOs.
- 8 June 2022
- Published by IOP Publishing in Biomedical Materials
- Vol. 17 (4) , 045020
Granular Matrigel: restructuring a trusted extracellular matrix material for improved permeability
Matrigel is a polymeric extracellular matrix material produced by mouse cancer cells. Over the past four decades, Matrigel has been shown to support a wide variety of two- and three-dimensional cell and tissue culture applications including organoids. Despite widespread use, transport of molecules, cells, and colloidal particles through Matrigel can be limited. These limitations restrict cell growth, viability, and function and limit Matrigel applications. A strategy to improve transport through a hydrogel without modifying the chemistry or composition of the gel is to physically restructure the material into microscopic microgels and then pack them together to form a porous material. These ‘granular’ hydrogels have been created using a variety of synthetic hydrogels, but granular hydrogels composed of Matrigel have not yet been reported. Here we present a drop-based microfluidics approach for structuring Matrigel into a three-dimensional, mesoporous material composed of packed Matrigel microgels, which we call granular Matrigel. We show that restructuring Matrigel in this manner enhances the transport of colloidal particles and human dendritic cells (DCs) through the gel while providing sufficient mechanical support for culture of human gastric organoids (HGOs) and co-culture of human DCs with HGOs.
- Open Access
Single cell infection with influenza A virus using drop-based microfluidics
Summary: Influenza A virus (IAV) is an RNA virus with high genetic diversity which necessitates the development of new vaccines targeting emerging mutations each year. As IAV exists in genetically heterogeneous populations, current studies focus on understanding population dynamics at the single cell level. These studies include novel methodology that can be used for probing populations at the single cell level, such as single cell sequencing and microfluidics. Here, we introduce a drop-based microfluidics method to study IAV infection at a single cell level by isolating infected host cells in microscale drops. Single human alveolar basal epithelial (A549), Madin-Darby Canine Kidney cells (MDCK) and MDCK + human siat7e gene (Siat7e) cells infected with the pandemic A/California/07/2009 (H1N1) strain were encapsulated within 50 μm radii drops and incubated at 37°C. We demonstrate that drops remain stable over 24 hours, that 75% of cells remain viable, and that IAV virus can propagate within the drops. Drop-based microfluidics therefore enables single cell analysis of viral populations produced from individually infected cells.
Open AccessSingle cell infection with influenza A virus using drop-based microfluidics
Summary: Influenza A virus (IAV) is an RNA virus with high genetic diversity which necessitates the development of new vaccines targeting emerging mutations each year. As IAV exists in genetically heterogeneous populations, current studies focus on understanding population dynamics at the single cell level. These studies include novel methodology that can be used for probing populations at the single cell level, such as single cell sequencing and microfluidics. Here, we introduce a drop-based microfluidics method to study IAV infection at a single cell level by isolating infected host cells in microscale drops. Single human alveolar basal epithelial (A549), Madin-Darby Canine Kidney cells (MDCK) and MDCK + human siat7e gene (Siat7e) cells infected with the pandemic A/California/07/2009 (H1N1) strain were encapsulated within 50 μm radii drops and incubated at 37°C. We demonstrate that drops remain stable over 24 hours, that 75% of cells remain viable, and that IAV virus can propagate within the drops. Drop-based microfluidics therefore enables single cell analysis of viral populations produced from individually infected cells.