Georges Atallah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Georges Atallah has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Adeeb Ali Kunju Abdulla Kutty
Mechanical and Industrial Engineering Department College of Engineering Qatar University Doha Qatar
1 shared publication Ahmed Abadi
Mechanical and Industrial Engineering Department College of Engineering Qatar University Doha Qatar
1 shared publication- Faris Tarlochan
Qatar University
1 shared publication - Murat Kucukvar
Qatar Transportation and Traffic Safety Research Center, College of Engineering, Qatar University, Doha, Qatar
1 shared publication - Nasser M. Al Jurf
Department of Mechanical and Industrial Engineering, College of Engineering, Qatar University, Doha P.O. Box 2713, Qatar
1 shared publication Salim Ali Al Yafei
Mechanical and Industrial Engineering Department College of Engineering Qatar University Doha Qatar
1 shared publication
Latest Publications
- Open Access
- 17 September 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (18) , 10374
Comparison between Variable and Constant Refrigerant Flow Air Conditioning Systems in Arid Climate: Life Cycle Cost Analysis and Energy Savings
All over the world, there is a call to encourage sustainable energy thinking and implementation. There is an urgent need to consider sustainable solutions in any design projects that are able to reduce energy consumption. In the heating, ventilation, and air conditioning field, the rise of the variable refrigerant flow systems has made big progress. This study presents a life cycle cost analysis to evaluate the economic feasibility of constant refrigerant flow (CRF), and in particular, the conventional ducted unit air conditioning system and the variable refrigerant flow (VRF) system by using detailed cooling load profiles, as well as initial, operating, and maintenance costs. Two operating hours scenarios are utilized and the present worth value technique for life cycle cost analysis is applied to an existing office building located in Qatar, which can be conditioned by CRF and VRF systems. The results indicate that, although the initial cost of the VRF system is higher than that of the CRF system by 23%, the present worth cost of the VRF system is much lower than that of the CRF system at the end of the lifetime due to lower operating costs. There is also a significant energy saving of 27% by using VRF compared to the CRF. The implementation of these results on a national scale will promote the use of sustainable energy technologies such as the VRF system.
- 17 September 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (18) , 10374
Open AccessComparison between Variable and Constant Refrigerant Flow Air Conditioning Systems in Arid Climate: Life Cycle Cost Analysis and Energy Savings
All over the world, there is a call to encourage sustainable energy thinking and implementation. There is an urgent need to consider sustainable solutions in any design projects that are able to reduce energy consumption. In the heating, ventilation, and air conditioning field, the rise of the variable refrigerant flow systems has made big progress. This study presents a life cycle cost analysis to evaluate the economic feasibility of constant refrigerant flow (CRF), and in particular, the conventional ducted unit air conditioning system and the variable refrigerant flow (VRF) system by using detailed cooling load profiles, as well as initial, operating, and maintenance costs. Two operating hours scenarios are utilized and the present worth value technique for life cycle cost analysis is applied to an existing office building located in Qatar, which can be conditioned by CRF and VRF systems. The results indicate that, although the initial cost of the VRF system is higher than that of the CRF system by 23%, the present worth cost of the VRF system is much lower than that of the CRF system at the end of the lifetime due to lower operating costs. There is also a significant energy saving of 27% by using VRF compared to the CRF. The implementation of these results on a national scale will promote the use of sustainable energy technologies such as the VRF system.
- Open Access
- 17 August 2021
- Published by IEOM Society International
- Vol. 11 (8)
A Comparative Study on Pandemic Response and Their Impact on Economic Growth: Evidence From COVID-19 Outbreak In Scandanavia
Coronavirus strikes again with the delta variant and puts the world in a phase 3 pandemic state. Countries all over the world have adopted different response mechanisms to contain the virus's spread. Health officials call for lockdown strategies as Covid-19 cases rise in most countries. In a faster and more effective worldwide vaccination scenario, leading economies are racing towards
- 17 August 2021
- Published by IEOM Society International
- Vol. 11 (8)
Open AccessA Comparative Study on Pandemic Response and Their Impact on Economic Growth: Evidence From COVID-19 Outbreak In Scandanavia
Coronavirus strikes again with the delta variant and puts the world in a phase 3 pandemic state. Countries all over the world have adopted different response mechanisms to contain the virus's spread. Health officials call for lockdown strategies as Covid-19 cases rise in most countries. In a faster and more effective worldwide vaccination scenario, leading economies are racing towards