Hossein Afzali Gorouh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hossein Afzali Gorouh has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Abolfazl Hayati
Department of Building Engineering, Energy Systems and Sustainability Science, University of Gävle, 801 76 Gävle, Sweden
3 shared publications - Diogo Cabral
Department of Building Engineering, Energy Systems and Sustainability Science, University of Gävle, Kungsbäcksvägen 47, 801 76 Gävle, Sweden
3 shared publications - Mazyar Salmanzadeh
Department of Mechanical Engineering, Shahid Bahonar University of Kerman, Kerman, Iran
2 shared publications - Pouriya Nasseriyan
Department of Mechanical Engineering, Shahid Bahonar University of Kerman, Kerman 76175 133, Iran
2 shared publications - Ahmad Hassanzadeh
Maelgwyn Mineral Services Ltd., Ty Maelgwyn, 1A Gower Street, Cathays, Cardiff CF24 4PA, UK
1 shared publication Björn Karlsson
1 shared publication
Latest Publications
- 25 December 2025
- Published by Elsevier in Minerals Engineering
- Vol. 237
CFD study of two-phase flow hydrodynamics in the Imhoflot™ G-06 flotation cell using Eulerian and Lagrangian approaches
- 25 December 2025
- Published by Elsevier in Minerals Engineering
- Vol. 237
CFD study of two-phase flow hydrodynamics in the Imhoflot™ G-06 flotation cell using Eulerian and Lagrangian approaches
- Open Access
Experimental Electrical Assessment Evaluation of a Vertical n-PERT Half-Size Bifacial Solar Cell String Receiver on a Parabolic Trough Solar Collector
A two-trough parabolic-shaped concentrating photovoltaic solar collector with a vertical half-size ‘phosphorus-passivated emitter rear totally diffused’ bifacial cell string receiver was designed and built for household applications, with the aim of smooth the electrical ‘duck curve’. The study consisted in testing the concentrating photovoltaic solar collector outdoors, under real weather conditions, for its daily electrical peak power and efficiency, as well as for its electrical transversal and longitudinal Incidence Angle Modifier direction. The outdoor testing measurements were conducted in a parabolic trough with low concentration coupled with a central vertical half-size ‘phosphorus-passivated emitter rear totally diffused’ bifacial cell string receiver. Furthermore, the electrical transversal Incidence Angle Modifier showed to be very delicate due to the position and outline of the receiver, which led to an electrical peak efficiency close to 10% at ±25° (i.e., for an electrical power output of around 49.3 W/m2). To validate the measured parameters, a ray-tracing software has been used, where the measured Incidence Angle Modifiers have a very good agreement with the simulated Incidence Angle Modifiers (e.g., deviation of <4%). Consequently, the concentrating solar collector met the objective of lowering the Photovoltaic cell stress and high radiation intensity, by shifting the electrical peak power at normal (e.g., at 0°) to higher incidence angles (e.g., ±25°); this aids the electrical demand peak shaving, by having the highest electrical power production displaced from the highest intensity solar radiation during the day.
Open AccessExperimental Electrical Assessment Evaluation of a Vertical n-PERT Half-Size Bifacial Solar Cell String Receiver on a Parabolic Trough Solar Collector
A two-trough parabolic-shaped concentrating photovoltaic solar collector with a vertical half-size ‘phosphorus-passivated emitter rear totally diffused’ bifacial cell string receiver was designed and built for household applications, with the aim of smooth the electrical ‘duck curve’. The study consisted in testing the concentrating photovoltaic solar collector outdoors, under real weather conditions, for its daily electrical peak power and efficiency, as well as for its electrical transversal and longitudinal Incidence Angle Modifier direction. The outdoor testing measurements were conducted in a parabolic trough with low concentration coupled with a central vertical half-size ‘phosphorus-passivated emitter rear totally diffused’ bifacial cell string receiver. Furthermore, the electrical transversal Incidence Angle Modifier showed to be very delicate due to the position and outline of the receiver, which led to an electrical peak efficiency close to 10% at ±25° (i.e., for an electrical power output of around 49.3 W/m2). To validate the measured parameters, a ray-tracing software has been used, where the measured Incidence Angle Modifiers have a very good agreement with the simulated Incidence Angle Modifiers (e.g., deviation of <4%). Consequently, the concentrating solar collector met the objective of lowering the Photovoltaic cell stress and high radiation intensity, by shifting the electrical peak power at normal (e.g., at 0°) to higher incidence angles (e.g., ±25°); this aids the electrical demand peak shaving, by having the highest electrical power production displaced from the highest intensity solar radiation during the day.
- Open Access
- 1 January 2022
- Published by Elsevier in Renewable Energy
- Vol. 181, 535-553
Thermal modelling and experimental evaluation of a novel concentrating photovoltaic thermal collector (CPVT) with parabolic concentrator
- 1 January 2022
- Published by Elsevier in Renewable Energy
- Vol. 181, 535-553
Open AccessThermal modelling and experimental evaluation of a novel concentrating photovoltaic thermal collector (CPVT) with parabolic concentrator
- Open Access
Numerical and Experimental Study of an Asymmetric CPC-PVT Solar Collector
Photovoltaic (PV) panels and thermal collectors are commonly known as mature technologies to capture solar energy. The efficiency of PV cells decreases as operating cell temperature increases. Photovoltaic Thermal Collectors (PVT) offer a way to mitigate this performance reduction by coupling solar cells with a thermal absorber that can actively remove the excess heat from the solar cells to the Heat Transfer Fluid (HTF). In order for PVT collectors to effectively counter the negative effects of increased operating cell temperature, it is fundamental to have an adequate heat transfer from the cells to the HTF. This paper analyzes the operating temperature of the cells in a low concentrating PVT solar collector, by means of both experimental and Computational Fluid Dynamics (CFD) simulation results on the Solarus asymmetric Compound Parabolic Concentrator (CPC) PowerCollector (PC). The PC solar collector features a Compound Parabolic Concentrator (CPC) reflector geometry called the Maximum Reflector Concentration (MaReCo) geometry. This collector is suited for applications such as Domestic Hot Water (DHW). An experimental setup was installed in the outdoor testing laboratory at Gävle University (Sweden) with the ability to measure ambient, cell and HTF temperature, flow rate and solar radiation. The experimental results were validated by means of an in-house developed CFD model. Based on the validated model, the effect of collector tilt angle, HTF, insulation (on the back side of the reflector), receiver material and front glass on the collector performance were considered. The impact of tilt angle is more pronounced on the thermal production than the electrical one. Furthermore, the HTF recirculation with an average temperature of 35.1 °C and 2.2 L/min flow rate showed that the electrical yield can increase by 25%. On the other hand, by using insulation, the thermal yield increases up to 3% when working at a temperature of 23 °C above ambient.
Open AccessNumerical and Experimental Study of an Asymmetric CPC-PVT Solar Collector
Photovoltaic (PV) panels and thermal collectors are commonly known as mature technologies to capture solar energy. The efficiency of PV cells decreases as operating cell temperature increases. Photovoltaic Thermal Collectors (PVT) offer a way to mitigate this performance reduction by coupling solar cells with a thermal absorber that can actively remove the excess heat from the solar cells to the Heat Transfer Fluid (HTF). In order for PVT collectors to effectively counter the negative effects of increased operating cell temperature, it is fundamental to have an adequate heat transfer from the cells to the HTF. This paper analyzes the operating temperature of the cells in a low concentrating PVT solar collector, by means of both experimental and Computational Fluid Dynamics (CFD) simulation results on the Solarus asymmetric Compound Parabolic Concentrator (CPC) PowerCollector (PC). The PC solar collector features a Compound Parabolic Concentrator (CPC) reflector geometry called the Maximum Reflector Concentration (MaReCo) geometry. This collector is suited for applications such as Domestic Hot Water (DHW). An experimental setup was installed in the outdoor testing laboratory at Gävle University (Sweden) with the ability to measure ambient, cell and HTF temperature, flow rate and solar radiation. The experimental results were validated by means of an in-house developed CFD model. Based on the validated model, the effect of collector tilt angle, HTF, insulation (on the back side of the reflector), receiver material and front glass on the collector performance were considered. The impact of tilt angle is more pronounced on the thermal production than the electrical one. Furthermore, the HTF recirculation with an average temperature of 35.1 °C and 2.2 L/min flow rate showed that the electrical yield can increase by 25%. On the other hand, by using insulation, the thermal yield increases up to 3% when working at a temperature of 23 °C above ambient.