VRVinitha L. Rashme

Vinitha L. Rashme

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vinitha L. Rashme has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Cataract surgery risk stratification in phacoemulsification and manual small incision cataract surgery in a teaching hospital

    by Madhu Shekhar, Payal Choudhury, Gomati Ramya, R. Sankarananthan, Sundar Balagiri, Hiruni Kaushalya Wijesinghe

    Purpose To evaluate a system that objectively assesses the risk of cataract surgery complications performed with phacoemulsification and manual small incision cataract surgery (MSICS) techniques. Methods The study was a retrospective comparative interventional case series. Electronic medical records of consecutive eyes that underwent cataract surgery from January 2019 to December 2019 were evaluated. Patient’s demographic data and preoperative risk factors were identified, and cataract was categorized as per Lens Opacities Classification System (III). Cataract eyes were grouped into normal cataract cases (G1) and complex cataract cases (G2 and G3), based on the risk factors. The rate of complications in each group and the rate of each complication were calculated and compared. Results The overall rate of anyone complication was 2.2% with 2.3% in G1, 1.0% in G2 and 3.9% in G3 (p < 0.001). MSICS technique, mostly used for complex cases (54.2%), reported a higher complication rate than the phacoemulsification technique (2.9% vs 1.4%, p < 0.001). However, the complication rates among the normal and complex cases were similar (2.3% vs 2.2%, p = 0.376). The total posterior capsular tear rate was 1.1% with no vitreous loss in nearly 1 in eight eyes. Conclusion A preoperative risk stratification system is crucial for obtaining informed consent and better allocation of cases to surgeons based on their expertise to minimize intraoperative complications.


  • Comparison of two phacoemulsification system handpieces: prospective randomized comparative study

    by Dhanya Cyril, Pathakamuri Dnb Brahmani, Senthil Prasad, Vinitha L. Rashme, Sankarananthan R, Nikhil Rajendra Kamble, Logesh M.Sc Balakrishnan, Kamatchi Nagu, Madhu Shekhar

    Purpose: To compare the safety and efficacy of Active Sentry handpiece with Ozil handpiece for Centurion phacoemulsification system. Setting: Tertiary eye center, South India. Design: Prospective observational study. Methods: 204 eyes of 204 patients with uncomplicated cataract who underwent phacoemulsification cataract surgery with Centurion Vision System were randomized into 2 groups: Ozil handpiece (n = 101) and Active Sentry handpiece (n = 103). Intraoperative factors such as patient pain perception, surgeon comfort level, amount of phacoemulsification energy and aspiration fluid used, and frequency of activation of active surge mitigation (ASM) were analyzed, and postoperatively, corrected distance visual acuity (CDVA) and corneal edema on day 1 were compared. Results: A total of 204 eyes of 204 patients were included among which 101 underwent surgery with ozil hand piece and 103 with Active Sentry handpiece. Patient pain perception was comparable between the groups with no statistically significant differences in patients who had pain-free surgery (66% vs 61.3%) and those who experienced moderate pain (24.3% vs 28.7%). Surgeons were more comfortable using Ozil handpiece during entry into anterior chamber and emulsification of hard nuclei (48.5% vs 28.6%). The mean cumulative dissipated energy for soft and hard cataracts was 5.6 and 4.8 and 9.3 and 9.4 for Ozil and Active Sentry groups, respectively. ASM was activated for 53 eyes (51.5%), of which 42 eyes (79.2%) had soft cataract and 11 eyes (20.7%) hard cataract. Postoperative CDVA and incidence of corneal edema were comparable between the groups. Conclusions: For Centurion Vision System, Active Sentry handpiece was as safe and efficacious as the Ozil handpiece with added benefit of operating at lower intraocular pressure levels.