Kim Greenwood
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kim Greenwood has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- James Robert Green
Department of Systems and Computer Engineering, Carleton University, Ottawa, ON K1S 5B6, Canada
6 shared publications - JoAnn Harrold
Neonatology, Children’s Hospital of Eastern Ontario, Ottawa, ON K1H 8L1, Canada
6 shared publications - Yasmina Souley Dosso
Department of Systems and Computer Engineering, Carleton University, Ottawa, Canada
5 shared publications - Daniel G. Kyrollos
Department of Systems and Computer Engineering, Carleton University Biomedical Informatics Collaboratory, Carleton University, Ottawa, ON, Canada
3 shared publications - Anthony Fuller
Department of Systems and Computer Engineering, Carleton University, Ottawa, ON, Canada
2 shared publications Amente Bekele
Systems and Computer Engineering, Carleton University, Ottawa, Canada
1 shared publication
Latest Publications
- Open Access
Depth-Based Intervention Detection in the Neonatal Intensive Care Unit Using Vision Transformers
Depth cameras can provide an effective, noncontact, and privacy-preserving means to monitor patients in the Neonatal Intensive Care Unit (NICU). Clinical interventions and routine care events can disrupt video-based patient monitoring. Automatically detecting these periods can decrease the time required for hand-annotating recordings, which is needed for system development. Moreover, the automatic detection can be used in the future for real-time or retrospective intervention event classification. An intervention detection method based solely on depth data was developed using a vision transformer (ViT) model utilizing real-world data from patients in the NICU. Multiple design parameters were investigated, including encoding of depth data and perspective transform to account for nonoptimal camera placement. The best-performing model utilized ∼85 M trainable parameters, leveraged both perspective transform and HHA (Horizontal disparity, Height above ground, and Angle with gravity) encoding, and achieved a sensitivity of 85.6%, a precision of 89.8%, and an F1-Score of 87.6%.
Open AccessDepth-Based Intervention Detection in the Neonatal Intensive Care Unit Using Vision Transformers
Depth cameras can provide an effective, noncontact, and privacy-preserving means to monitor patients in the Neonatal Intensive Care Unit (NICU). Clinical interventions and routine care events can disrupt video-based patient monitoring. Automatically detecting these periods can decrease the time required for hand-annotating recordings, which is needed for system development. Moreover, the automatic detection can be used in the future for real-time or retrospective intervention event classification. An intervention detection method based solely on depth data was developed using a vision transformer (ViT) model utilizing real-world data from patients in the NICU. Multiple design parameters were investigated, including encoding of depth data and perspective transform to account for nonoptimal camera placement. The best-performing model utilized ∼85 M trainable parameters, leveraged both perspective transform and HHA (Horizontal disparity, Height above ground, and Angle with gravity) encoding, and achieved a sensitivity of 85.6%, a precision of 89.8%, and an F1-Score of 87.6%.
- Open Access
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 144168-144179
Uncertainty Measurements in Non-Contact Neonatal Heart Rate Monitoring
Continuously monitoring patient vital signs in the neonatal intensive care unit (NICU) requires wired sensors that can irritate fragile skin, motivating the development of non-contact physiologic signal estimation approaches. Such estimators typically involve a pipeline of multiple data analysis stages, including pre-processing, region of interest detection and tracking, and physiologic parameter estimation. Uncertainty in the estimated physiologic signal is often quantified strictly from the signal quality indicator (SQI) generated by the final stage of the pipeline. This manuscript proposes a framework to account for SQIs generated by each stage in a physiologic signal estimation pipeline and using the fusion of all SQIs to arrive at a refined measure of uncertainty in the final estimated physiologic parameter. This framework is demonstrated for heart rate (HR) estimation of newborns admitted in the NICU, where the pipeline includes bed occupancy detection, face detection, face tracking, and physiologic signal estimation. Different SQIs are derived at each stage and a novel fusion of all SQI metrics is shown to produce a more effective estimate of uncertainty in the final estimated HR.
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 144168-144179
Open AccessUncertainty Measurements in Non-Contact Neonatal Heart Rate Monitoring
Continuously monitoring patient vital signs in the neonatal intensive care unit (NICU) requires wired sensors that can irritate fragile skin, motivating the development of non-contact physiologic signal estimation approaches. Such estimators typically involve a pipeline of multiple data analysis stages, including pre-processing, region of interest detection and tracking, and physiologic parameter estimation. Uncertainty in the estimated physiologic signal is often quantified strictly from the signal quality indicator (SQI) generated by the final stage of the pipeline. This manuscript proposes a framework to account for SQIs generated by each stage in a physiologic signal estimation pipeline and using the fusion of all SQIs to arrive at a refined measure of uncertainty in the final estimated physiologic parameter. This framework is demonstrated for heart rate (HR) estimation of newborns admitted in the NICU, where the pipeline includes bed occupancy detection, face detection, face tracking, and physiologic signal estimation. Different SQIs are derived at each stage and a novel fusion of all SQI metrics is shown to produce a more effective estimate of uncertainty in the final estimated HR.
- 1 July 2023
- Published by Wolters Kluwer Health in Journal of Clinical Engineering
- Vol. 48 (3) , 122-129
Strategic Budget Planning for Complex Medical Devices: A Case Study on Surgical Microscopes
Dramatic developments in medical device technologies significantly influence the cost of equipment acquisition and operating expenses. Sometimes the budget estimation needed for rudimentary medical equipment can be complicated, even more so for a complex device with several add-on features. In Canada, the budget allocated to capital equipment purchases is challenging because the budget comes from the provincial government to the hospitals. The capital equipment budget amount is challenging because of the public healthcare funding model, whereby fiscal budgets come from the provincial government to the hospitals. The capital equipment budget allocation is limited and restricted in hospital as “big ticket” items compete with other capital requests. Having a strategic budgeting plan, completed by a clinical engineer, ensures a sufficient budget for the capital request. A strategic budgeting plan was central to this study to estimate the required funding for replacing aged existing surgical microscopes at the Children's Hospital of Eastern Ontario. This study demonstrates the development of a methodology to guide budget planning and includes inventory assessment, market analysis, the identification of clinical requirements, cost analysis, and the utilization of the outputs of these steps for capital planning requests. A basic step-by-step approach can be followed by any clinical engineering department before submitting a capital planning request for complex medical devices.
- 1 July 2023
- Published by Wolters Kluwer Health in Journal of Clinical Engineering
- Vol. 48 (3) , 122-129
Strategic Budget Planning for Complex Medical Devices: A Case Study on Surgical Microscopes
Dramatic developments in medical device technologies significantly influence the cost of equipment acquisition and operating expenses. Sometimes the budget estimation needed for rudimentary medical equipment can be complicated, even more so for a complex device with several add-on features. In Canada, the budget allocated to capital equipment purchases is challenging because the budget comes from the provincial government to the hospitals. The capital equipment budget amount is challenging because of the public healthcare funding model, whereby fiscal budgets come from the provincial government to the hospitals. The capital equipment budget allocation is limited and restricted in hospital as “big ticket” items compete with other capital requests. Having a strategic budgeting plan, completed by a clinical engineer, ensures a sufficient budget for the capital request. A strategic budgeting plan was central to this study to estimate the required funding for replacing aged existing surgical microscopes at the Children's Hospital of Eastern Ontario. This study demonstrates the development of a methodology to guide budget planning and includes inventory assessment, market analysis, the identification of clinical requirements, cost analysis, and the utilization of the outputs of these steps for capital planning requests. A basic step-by-step approach can be followed by any clinical engineering department before submitting a capital planning request for complex medical devices.
- Open Access
Under the Cover Infant Pose Estimation using Multimodal Data
Infant pose monitoring during sleep has multiple applications in both healthcare and home settings. In a healthcare setting, pose detection can be used for region of interest detection and movement detection for noncontact based monitoring systems. In a home setting, pose detection can be used to detect sleep positions which has shown to have a strong influence on multiple health factors. However, pose monitoring during sleep is challenging due to heavy occlusions from blanket coverings and low lighting. To address this, we present a novel dataset, Simultaneously-collected multimodal Mannequin Lying pose (SMaL) dataset, for under the cover infant pose estimation. We collect depth and pressure imagery of an infant mannequin in different poses under various cover conditions. We successfully infer full body pose under the cover by training state-of-art pose estimation methods and leveraging existing multimodal adult pose datasets for transfer learning. We demonstrate a hierarchical pretraining strategy for transformer-based models to significantly improve performance on our dataset. Our best performing model was able to detect joints under the cover within 25mm 86% of the time with an overall mean error of 16.9mm. Data, code and models publicly available at https://github.com/DanielKyr/SMaL
Open AccessUnder the Cover Infant Pose Estimation using Multimodal Data
Infant pose monitoring during sleep has multiple applications in both healthcare and home settings. In a healthcare setting, pose detection can be used for region of interest detection and movement detection for noncontact based monitoring systems. In a home setting, pose detection can be used to detect sleep positions which has shown to have a strong influence on multiple health factors. However, pose monitoring during sleep is challenging due to heavy occlusions from blanket coverings and low lighting. To address this, we present a novel dataset, Simultaneously-collected multimodal Mannequin Lying pose (SMaL) dataset, for under the cover infant pose estimation. We collect depth and pressure imagery of an infant mannequin in different poses under various cover conditions. We successfully infer full body pose under the cover by training state-of-art pose estimation methods and leveraging existing multimodal adult pose datasets for transfer learning. We demonstrate a hierarchical pretraining strategy for transformer-based models to significantly improve performance on our dataset. Our best performing model was able to detect joints under the cover within 25mm 86% of the time with an overall mean error of 16.9mm. Data, code and models publicly available at https://github.com/DanielKyr/SMaL
- 13 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-12
Under the Cover Infant Pose Estimation Using Multimodal Data
Infant pose monitoring during sleep has multiple applications in both healthcare and home settings. In a healthcare setting, pose detection can be used for region of interest detection and movement detection for noncontact-based monitoring systems. In a home setting, pose detection can be used to detect sleep positions which has shown to have a strong influence on multiple health factors. However, pose monitoring during sleep is challenging due to heavy occlusions from blanket coverings and low lighting. To address this, we present a novel dataset, Simultaneously-collected multimodal Mannequin Lying pose (SMaL) dataset, for under the cover infant pose estimation. We collect depth and pressure imagery of an infant mannequin in different poses under various cover conditions. We successfully infer full body pose under the cover by training state-of-art pose estimation methods and leveraging existing multimodal adult pose datasets for transfer learning. We demonstrate a hierarchical pretraining strategy for transformer-based models to significantly improve performance on our dataset. Our best performing model was able to detect joints under the cover within 25mm 86% of the time with an overall mean error of 16.9mm. Data, code and models publicly available at https://github.com/DanielKyr/SMaL.
- 13 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-12
Under the Cover Infant Pose Estimation Using Multimodal Data
Infant pose monitoring during sleep has multiple applications in both healthcare and home settings. In a healthcare setting, pose detection can be used for region of interest detection and movement detection for noncontact-based monitoring systems. In a home setting, pose detection can be used to detect sleep positions which has shown to have a strong influence on multiple health factors. However, pose monitoring during sleep is challenging due to heavy occlusions from blanket coverings and low lighting. To address this, we present a novel dataset, Simultaneously-collected multimodal Mannequin Lying pose (SMaL) dataset, for under the cover infant pose estimation. We collect depth and pressure imagery of an infant mannequin in different poses under various cover conditions. We successfully infer full body pose under the cover by training state-of-art pose estimation methods and leveraging existing multimodal adult pose datasets for transfer learning. We demonstrate a hierarchical pretraining strategy for transformer-based models to significantly improve performance on our dataset. Our best performing model was able to detect joints under the cover within 25mm 86% of the time with an overall mean error of 16.9mm. Data, code and models publicly available at https://github.com/DanielKyr/SMaL.
- Open Access
- 8 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 62893-62909
NICUface: Robust Neonatal Face Detection in Complex NICU Scenes
The development of non-contact patient monitoring applications for the neonatal intensive care unit (NICU) is an active research area, particularly in facial video analysis. Recent studies have used facial video data to estimate vital signs, assess pain from facial expression, differentiate sleep-wake status, detect jaundice, and in face recognition. These applications depend on an accurate definition of the patient’s face as a region of interest (ROI). Most studies have required manual ROI definition, while others have leveraged automated face detectors developed for adult patients, without systematic validation for the neonatal population. To overcome these issues, this paper first evaluates the state-of-the-art in face detection in the NICU setting. Finding that such methods often fail in complex NICU environments, we demonstrate how fine-tuning can increase neonatal face detector robustness, resulting in our NICUface models. A large and diverse neonatal dataset was gathered from actual patients admitted to the NICU across three studies and gold standard face annotations were completed. In comparison to state-of-the-art face detectors, our NICUface models address NICU-specific challenges such as ongoing clinical intervention, phototherapy lighting, occlusions from hospital equipment, etc. These analyses culminate in the creation of robust NICUface detectors with improvements on our most challenging neonatal dataset of +36.14, +35.86, and +32.19 in AP30, AP50, and mAP respectively, relative to state-of-the-art CE-CLM, MTCNN, img2pose, RetinaFace, and YOLO5Face models. Face orientation estimation is also addressed, leading to an accuracy of 99.45%. Fine-tuned NICUface models, gold-standard face annotation data, and the face orientation estimation method are also released here.
- 8 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 62893-62909
Open AccessNICUface: Robust Neonatal Face Detection in Complex NICU Scenes
The development of non-contact patient monitoring applications for the neonatal intensive care unit (NICU) is an active research area, particularly in facial video analysis. Recent studies have used facial video data to estimate vital signs, assess pain from facial expression, differentiate sleep-wake status, detect jaundice, and in face recognition. These applications depend on an accurate definition of the patient’s face as a region of interest (ROI). Most studies have required manual ROI definition, while others have leveraged automated face detectors developed for adult patients, without systematic validation for the neonatal population. To overcome these issues, this paper first evaluates the state-of-the-art in face detection in the NICU setting. Finding that such methods often fail in complex NICU environments, we demonstrate how fine-tuning can increase neonatal face detector robustness, resulting in our NICUface models. A large and diverse neonatal dataset was gathered from actual patients admitted to the NICU across three studies and gold standard face annotations were completed. In comparison to state-of-the-art face detectors, our NICUface models address NICU-specific challenges such as ongoing clinical intervention, phototherapy lighting, occlusions from hospital equipment, etc. These analyses culminate in the creation of robust NICUface detectors with improvements on our most challenging neonatal dataset of +36.14, +35.86, and +32.19 in AP30, AP50, and mAP respectively, relative to state-of-the-art CE-CLM, MTCNN, img2pose, RetinaFace, and YOLO5Face models. Face orientation estimation is also addressed, leading to an accuracy of 99.45%. Fine-tuned NICUface models, gold-standard face annotation data, and the face orientation estimation method are also released here.
- Open Access
- 1 November 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 138, 104873
RGB-D scene analysis in the NICU
- 1 November 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 138, 104873
Open AccessRGB-D scene analysis in the NICU
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Real-time Neonatal Respiratory Rate Estimation using a Pressure-Sensitive Mat
We present an approach for real-time respiratory rate (RR) estimation in a neonatal intensive care unit (NICU) using a pressure-sensitive mat (PSM). Real patient data were collected in an NICU from four sources simultaneously: a PSM placed under the patient, a Draeger patient monitor, a video camera placed directly above the patient, and a custom bedside event annotation application running on a tablet. The PSM data were used to develop an algorithm for estimating the patient's RR. The results were evaluated against impedance pneumography (IP) based RR measurements from the patient monitor. In comparison to the IP estimates, we achieved a mean absolute error of 4.51 breaths per minute (bpm) for 3 hours of data collected from a single patient. Moreover, we show that our newer approach performs better than the previous frequency-based approach that was developed based on patient simulator data. The estimation accuracy achieved by the new algorithm meets clinical requirements for the determination of RR.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Real-time Neonatal Respiratory Rate Estimation using a Pressure-Sensitive Mat
We present an approach for real-time respiratory rate (RR) estimation in a neonatal intensive care unit (NICU) using a pressure-sensitive mat (PSM). Real patient data were collected in an NICU from four sources simultaneously: a PSM placed under the patient, a Draeger patient monitor, a video camera placed directly above the patient, and a custom bedside event annotation application running on a tablet. The PSM data were used to develop an algorithm for estimating the patient's RR. The results were evaluated against impedance pneumography (IP) based RR measurements from the patient monitor. In comparison to the IP estimates, we achieved a mean absolute error of 4.51 breaths per minute (bpm) for 3 hours of data collected from a single patient. Moreover, we show that our newer approach performs better than the previous frequency-based approach that was developed based on patient simulator data. The estimation accuracy achieved by the new algorithm meets clinical requirements for the determination of RR.
- 1 January 2014
- Published by Wolters Kluwer Health in Journal of Clinical Engineering
- Vol. 39 (1) , 28-32
The Dividends of an Effective Clinical Technology Management Program
The growth of clinical engineering (CE) departments in the last 20 years has stalled within healthcare facilities despite the fact that the inventory of medical devices within all facilities has grown substantially during this interval. In many organizations, CE’s role is only to maintain the organization’s clinical equipment. The developmental strategy used by CE at the Children’s Hospital of Eastern Ontario has reversed this trend at this facility. This was accomplished by taking on the role of the health technology manager for the institution. Clinical engineering has, since 2001, coordinated the long-range planning function for capital equipment at Children’s Hospital of Eastern Ontario. Since taking on this role, CE has also been assigned the management of annual corporate capital equipment procurement process and coordination of the ongoing implementation of new clinical equipment.
- 1 January 2014
- Published by Wolters Kluwer Health in Journal of Clinical Engineering
- Vol. 39 (1) , 28-32
The Dividends of an Effective Clinical Technology Management Program
The growth of clinical engineering (CE) departments in the last 20 years has stalled within healthcare facilities despite the fact that the inventory of medical devices within all facilities has grown substantially during this interval. In many organizations, CE’s role is only to maintain the organization’s clinical equipment. The developmental strategy used by CE at the Children’s Hospital of Eastern Ontario has reversed this trend at this facility. This was accomplished by taking on the role of the health technology manager for the institution. Clinical engineering has, since 2001, coordinated the long-range planning function for capital equipment at Children’s Hospital of Eastern Ontario. Since taking on this role, CE has also been assigned the management of annual corporate capital equipment procurement process and coordination of the ongoing implementation of new clinical equipment.
- Open Access
- 1 June 2013
- Published by BMJ in Archives of Disease in Childhood
- Vol. 98 (Suppl 1) , A63-A65
G137(P) How to Save a Smile!
- 1 June 2013
- Published by BMJ in Archives of Disease in Childhood
- Vol. 98 (Suppl 1) , A63-A65
Open AccessG137(P) How to Save a Smile!