Keisuke Tochigi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Keisuke Tochigi has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Kazuhito Arai
Department of Orthodontics, School of Life Dentistry, The Nippon Dental University, Tokyo, Japan
3 shared publications Akihiko Tachi
Graduate School of Life Dentistry at Tokyo, the Nippon Dental University, Tokyo, Japan
2 shared publicationsKazuhito Arai
Department of Orthodontics, School of Life Dentistry at Tokyo, The Nippon Dental University, Tokyo, Japan
2 shared publications- Naomi Saze
Department of Orthodontics, School of Life Dentistry at Tokyo, The Nippon Dental University, Tokyo, Japan
2 shared publications - Akihiko Tachi
Nippon Dent Univ Hosp, Dept Orthodont & Pediat Dent, Tokyo, Japan
1 shared publication Naomi Saze
Department of Orthodontics, School of Life Dentistry at Tokyo, The Nippon Dental University, Tokyo, Japan
1 shared publication
Latest Publications
- 5 June 2023
- Published by SAGE Publications in Journal of Orthodontics
- Vol. 50 (4) , 378-384
A new orthodontic force simulation system with a simulated periodontal ligament to measure the delivered force at the root apex
Objective: To develop a new orthodontic force simulation system with a simulated periodontal ligament (PDL) that enables measurement of the delivered force at the root apex and to clarify the relationship between the applied orthodontic force and the delivered force at the root apex. Design: In vitro study. Setting: Orthodontics department of a university, Tokyo, Japan. Methods: A new orthodontic force simulation system that enables measurement of the force at the root apex of the maxillary central incisor, was developed. Lingual and intrusion movements were simulated with applied orthodontic force at three levels: 50, 100 and 200 gf. The delivered forces at the root apex were compared between the two movements. Furthermore, the ratio of delivered force at the root apex to the applied orthodontic force (the apex force ratio) was calculated. Results: The magnitudes of delivered forces at the root apex were significantly greater in intrusion movement than in lingual movement ( P < 0.01). The apex force ratios were in the range of 47.3%–56.2% for lingual movement and 85.6%–86.2% for intrusion movement. Conclusion: The present study, of a newly developed orthodontic force simulation system, showed that the characteristics of the delivered force at the root apex differed according to the direction of tooth movement.
- 5 June 2023
- Published by SAGE Publications in Journal of Orthodontics
- Vol. 50 (4) , 378-384
A new orthodontic force simulation system with a simulated periodontal ligament to measure the delivered force at the root apex
Objective: To develop a new orthodontic force simulation system with a simulated periodontal ligament (PDL) that enables measurement of the delivered force at the root apex and to clarify the relationship between the applied orthodontic force and the delivered force at the root apex. Design: In vitro study. Setting: Orthodontics department of a university, Tokyo, Japan. Methods: A new orthodontic force simulation system that enables measurement of the force at the root apex of the maxillary central incisor, was developed. Lingual and intrusion movements were simulated with applied orthodontic force at three levels: 50, 100 and 200 gf. The delivered forces at the root apex were compared between the two movements. Furthermore, the ratio of delivered force at the root apex to the applied orthodontic force (the apex force ratio) was calculated. Results: The magnitudes of delivered forces at the root apex were significantly greater in intrusion movement than in lingual movement ( P < 0.01). The apex force ratios were in the range of 47.3%–56.2% for lingual movement and 85.6%–86.2% for intrusion movement. Conclusion: The present study, of a newly developed orthodontic force simulation system, showed that the characteristics of the delivered force at the root apex differed according to the direction of tooth movement.
- Open Access
- 1 December 2021
- Published by Springer Nature in Progress in Orthodontics
- Vol. 22 (1) , 1-12
Impact of the prefabricated forms of NiTi archwires on orthodontic forces delivered to the mandibular dental arch
Background: Although preformed archwires with a variety of arch forms are currently commercially available, the effects of variation in the shape of these archwires on the orthodontic force at each tooth are not well understood. Therefore, we evaluated the forces delivered by various types of commercially available preformed nickel–titanium alloy (NiTi) archwires in a simulated mandibular dental arch.Methods: Sixty-three types of 0.019 × 0.025-inch preformed NiTi archwires from 15 manufactures were selected for analysis. The intercanine width (ICW) and intermolar width (IMW) of each archwire were measured at the mean canine and first molar depths of 30 untreated subjects with normal occlusions. Each archwire was placed in a multi-sensor measurement system simulating the mandibular dental arch of subjects with normal occlusions, and orthodontic forces in the facial-lingual direction at the central incisors, canines, and first molars were measured. Correlations between the ICW, IMW, and ICW/IMW ratio of archwires and the delivered forces were analyzed. The archwires were classified into the following four groups according to the ICW and IMW: Control group, ICW and IMW are within the means ± standard deviations of the normal ranges; Ovoid group, narrow ICW and IMW; Tapered group, narrow ICW; and Square group, narrow IMW. The forces were compared among these groups for each tooth.Results: Significant correlations between the measured archwire width and force to each tooth were found, except between IMW and forces at the central incisors and canines. Significant differences in the forces were found among all groups, except between the Ovoid and Tapered groups at all teeth and between the Ovoid/Tapered and Control groups at the first molar. Significantly greater orthodontic forces in the facial direction were delivered at the central incisors by the archwires in the Ovoid and Tapered groups when compared with the archwires in the other groups.Conclusion: These findings suggest that there is a possible risk of a clinically significant level of unfavorable orthodontic force being delivered to the mandibular incisors in labial inclination when using a preformed archwire with an ICW that is narrower than the dental arch.
- 1 December 2021
- Published by Springer Nature in Progress in Orthodontics
- Vol. 22 (1) , 1-12
Open AccessImpact of the prefabricated forms of NiTi archwires on orthodontic forces delivered to the mandibular dental arch
Background: Although preformed archwires with a variety of arch forms are currently commercially available, the effects of variation in the shape of these archwires on the orthodontic force at each tooth are not well understood. Therefore, we evaluated the forces delivered by various types of commercially available preformed nickel–titanium alloy (NiTi) archwires in a simulated mandibular dental arch.Methods: Sixty-three types of 0.019 × 0.025-inch preformed NiTi archwires from 15 manufactures were selected for analysis. The intercanine width (ICW) and intermolar width (IMW) of each archwire were measured at the mean canine and first molar depths of 30 untreated subjects with normal occlusions. Each archwire was placed in a multi-sensor measurement system simulating the mandibular dental arch of subjects with normal occlusions, and orthodontic forces in the facial-lingual direction at the central incisors, canines, and first molars were measured. Correlations between the ICW, IMW, and ICW/IMW ratio of archwires and the delivered forces were analyzed. The archwires were classified into the following four groups according to the ICW and IMW: Control group, ICW and IMW are within the means ± standard deviations of the normal ranges; Ovoid group, narrow ICW and IMW; Tapered group, narrow ICW; and Square group, narrow IMW. The forces were compared among these groups for each tooth.Results: Significant correlations between the measured archwire width and force to each tooth were found, except between IMW and forces at the central incisors and canines. Significant differences in the forces were found among all groups, except between the Ovoid and Tapered groups at all teeth and between the Ovoid/Tapered and Control groups at the first molar. Significantly greater orthodontic forces in the facial direction were delivered at the central incisors by the archwires in the Ovoid and Tapered groups when compared with the archwires in the other groups.Conclusion: These findings suggest that there is a possible risk of a clinically significant level of unfavorable orthodontic force being delivered to the mandibular incisors in labial inclination when using a preformed archwire with an ICW that is narrower than the dental arch.
- 19 September 2021
- Published by Taylor & Francis in Orthodontic Waves
- Vol. 80 (4) , 232-240
Effects of dental arch size variation on orthodontic forces delivered by preformed Ni-Ti archwires
The purpose of the present study was to investigate the effect of the size variation of the mandibular dental arch on the magnitude and direction of orthodontic forces delivered by a variety of com...
- 19 September 2021
- Published by Taylor & Francis in Orthodontic Waves
- Vol. 80 (4) , 232-240
Effects of dental arch size variation on orthodontic forces delivered by preformed Ni-Ti archwires
The purpose of the present study was to investigate the effect of the size variation of the mandibular dental arch on the magnitude and direction of orthodontic forces delivered by a variety of com...