Sergio Bernardini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sergio Bernardini has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Magrini
Department of Occupational Medicine, University of Rome “Tor Vergata”, 00100 Rome, Italy
2 shared publications - Beatrice Francavilla
Department of Otorhinolaryngology, University of Rome Tor Vergata, Rome 00133, Italy
2 shared publications - Denise Fiorelli
Department of Experimental Medicine, University of Rome Tor Vergata, Via Montpellier 1, 00133 Rome, Italy
2 shared publications - Francesco Maria Passali
Department of Clinical Sciences and Translational Medicine, Otorhinolaryngology Unit, Tor Vergata University of Rome, Via Cracovia 50, 00133 Rome, Italy
2 shared publications - Giuseppina Somma
Department of Biomedicine and Prevention, University of Rome Tor Vergata, 00133 Rome, Italy
2 shared publications - Luca Coppeta
Department of Biomedicine and Prevention, University of Rome Tor Vergata, 00133 Rome, Italy
2 shared publications
Latest Publications
- Open Access
Performance Evaluation of the New Chemiluminescence Immunoassay CL-1200i for HBV, HIV Panels
Infectious diseases such as HIV and HBV are a global concern for their impact in terms of public health and costs for national health services. A central role in contrasting the spread of the infections is represented by timely diagnosis. The speed of detection depends on several factors including the type of test used. Antibody response to hepatitis B surface antigens (anti-HBs) is an important serological marker used for HBV-infection detection. The aim of this study was to compare the performance of the Abbott system and of the new analyser Mindray 1200i in the detection of HBV- and HIV-infections. Clinical serum samples were collected from patients randomly selected from PTV University Hospital of University of Rome “Tor Vergata” and tested for HBV and HIV antibodies. Samples were evaluated by Mindray Cl 1200i CLIA screening tests for HBV and HIV and the results were compared with the Abbott Architect analytical system, the routine instrument of the hospital clinical biochemistry laboratory. Precision study, linearity, and carryover were performed on the results obtained. The agreement between the results of the Abbott and Mindray CLIA ranged from 99% to 100% and the discrepancy rate from 0% to 1%. The measurements demonstrated that the Mindray CL-1200i platform offers high-level performance with accurate and consistent test results and could represent a valuable tool if implemented in routine analysis.
Open AccessPerformance Evaluation of the New Chemiluminescence Immunoassay CL-1200i for HBV, HIV Panels
Infectious diseases such as HIV and HBV are a global concern for their impact in terms of public health and costs for national health services. A central role in contrasting the spread of the infections is represented by timely diagnosis. The speed of detection depends on several factors including the type of test used. Antibody response to hepatitis B surface antigens (anti-HBs) is an important serological marker used for HBV-infection detection. The aim of this study was to compare the performance of the Abbott system and of the new analyser Mindray 1200i in the detection of HBV- and HIV-infections. Clinical serum samples were collected from patients randomly selected from PTV University Hospital of University of Rome “Tor Vergata” and tested for HBV and HIV antibodies. Samples were evaluated by Mindray Cl 1200i CLIA screening tests for HBV and HIV and the results were compared with the Abbott Architect analytical system, the routine instrument of the hospital clinical biochemistry laboratory. Precision study, linearity, and carryover were performed on the results obtained. The agreement between the results of the Abbott and Mindray CLIA ranged from 99% to 100% and the discrepancy rate from 0% to 1%. The measurements demonstrated that the Mindray CL-1200i platform offers high-level performance with accurate and consistent test results and could represent a valuable tool if implemented in routine analysis.
- Open Access
Correction: Guerrieri et al. Nasal and Salivary Mucosal Humoral Immune Response Elicited by mRNA BNT162b2 COVID-19 Vaccine Compared to SARS-CoV-2 Natural Infection. Vaccines 2021, 9, 1499
The authors wish to make the following corrections to this paper
Open AccessCorrection: Guerrieri et al. Nasal and Salivary Mucosal Humoral Immune Response Elicited by mRNA BNT162b2 COVID-19 Vaccine Compared to SARS-CoV-2 Natural Infection. Vaccines 2021, 9, 1499
The authors wish to make the following corrections to this paper
- Open Access
Nasal and Salivary Mucosal Humoral Immune Response Elicited by mRNA BNT162b2 COVID-19 Vaccine Compared to SARS-CoV-2 Natural Infection
SARS-CoV-2 antibody assays are crucial in managing the COVID-19 pandemic. Approved mRNA COVID-19 vaccines are well known to induce a serum antibody responses against the spike protein and its RBD. Mucosal immunity plays a major role in the fight against COVID-19 directly at the site of virus entry; however, vaccine abilities to elicit mucosal immune responses have not been reported. We detected anti-SARS-CoV-2 IgA-S1 and IgG-RBD in three study populations (healthy controls, vaccinated subjects, and subjects recovered from COVID-19 infection) on serum, saliva, and nasal secretions using two commercial immunoassays (ELISA for IgA-S1 and chemiluminescent assay for IgG-RBD). Our results show that the mRNA BNT162b2 vaccine Comirnaty (Pfizer/BioNTech, New York, NY, USA) determines the production of nasal and salivary IgA-S1 and IgG-RBD against SARS-CoV-2. This mucosal humoral immune response is stronger after the injection of the second vaccine dose compared to subjects recovered from COVID-19. Since there is a lack of validated assays on saliva and nasal secretions, this study shows that our pre-analytical and analytical procedures are consistent with the data. Our findings indicate that the mRNA COVID-19 vaccine elicits antigen-specific nasal and salivary immune responses, and that mucosal antibody assays could be used as candidates for non-invasive monitoring of vaccine-induced protection against viral infection.
Open AccessNasal and Salivary Mucosal Humoral Immune Response Elicited by mRNA BNT162b2 COVID-19 Vaccine Compared to SARS-CoV-2 Natural Infection
SARS-CoV-2 antibody assays are crucial in managing the COVID-19 pandemic. Approved mRNA COVID-19 vaccines are well known to induce a serum antibody responses against the spike protein and its RBD. Mucosal immunity plays a major role in the fight against COVID-19 directly at the site of virus entry; however, vaccine abilities to elicit mucosal immune responses have not been reported. We detected anti-SARS-CoV-2 IgA-S1 and IgG-RBD in three study populations (healthy controls, vaccinated subjects, and subjects recovered from COVID-19 infection) on serum, saliva, and nasal secretions using two commercial immunoassays (ELISA for IgA-S1 and chemiluminescent assay for IgG-RBD). Our results show that the mRNA BNT162b2 vaccine Comirnaty (Pfizer/BioNTech, New York, NY, USA) determines the production of nasal and salivary IgA-S1 and IgG-RBD against SARS-CoV-2. This mucosal humoral immune response is stronger after the injection of the second vaccine dose compared to subjects recovered from COVID-19. Since there is a lack of validated assays on saliva and nasal secretions, this study shows that our pre-analytical and analytical procedures are consistent with the data. Our findings indicate that the mRNA COVID-19 vaccine elicits antigen-specific nasal and salivary immune responses, and that mucosal antibody assays could be used as candidates for non-invasive monitoring of vaccine-induced protection against viral infection.
- Open Access
- 20 September 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (18) , 4256
Post-Mortem RT-PCR Assay for SARS-CoV-2 RNA in COVID-19 Patients’ Corneal Epithelium, Conjunctival and Nasopharyngeal Swabs
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) disease has been described to possibly be associated with ocular surface disturbances. However, whether the virus could invade ocular tissues still remains elusive. In the present study, we tried to investigate the post-mortem presence of SARS-CoV-2 RNA in corneal epithelium gathered by patients with an ante-mortem confirmed diagnosis of Coronavirus disease-19 (COVID-19). Cadavers with an ante-mortem confirmed diagnosis of moderate to severe COVID-19 were examined. Clinical and demographic features were retrieved from hospital patients’ notes. For each cadaver, corneal scrapings, conjunctival swabs (CS) and nasopharyngeal swabs (NPS) were collected to perform real-time reverse transcriptase polymerase chain reaction ((RT)-PCR) for SARS-CoV-2. Fourteen consecutive cadavers with an ante-mortem confirmed diagnosis of moderate to severe COVID-19 were examined. The last NPS performed ante-mortem confirmed SARS-CoV-2 infection in 12/14 (85.7%) patients. The mean death-to-swab time (DtS) was 3.15 ± 0.5 (2.10–5.1) h. The post-mortem NPS and CS found positive for SARS-CoV-2 RNA were 9/14 (64.3%) and 3/28 (10.7%), respectively. None of the corneal epithelium scrapes tested positive to RT-PCR for SARS-CoV-2 RNA. These data promote the SARS-CoV-2 as not able to contaminate the post-mortem corneal epithelium, while it can persist in different other structures of the ocular surface (i.e., the conjunctiva). It is reasonable to assume that such a contamination can occur ante-mortem too.
- 20 September 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (18) , 4256
Open AccessPost-Mortem RT-PCR Assay for SARS-CoV-2 RNA in COVID-19 Patients’ Corneal Epithelium, Conjunctival and Nasopharyngeal Swabs
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) disease has been described to possibly be associated with ocular surface disturbances. However, whether the virus could invade ocular tissues still remains elusive. In the present study, we tried to investigate the post-mortem presence of SARS-CoV-2 RNA in corneal epithelium gathered by patients with an ante-mortem confirmed diagnosis of Coronavirus disease-19 (COVID-19). Cadavers with an ante-mortem confirmed diagnosis of moderate to severe COVID-19 were examined. Clinical and demographic features were retrieved from hospital patients’ notes. For each cadaver, corneal scrapings, conjunctival swabs (CS) and nasopharyngeal swabs (NPS) were collected to perform real-time reverse transcriptase polymerase chain reaction ((RT)-PCR) for SARS-CoV-2. Fourteen consecutive cadavers with an ante-mortem confirmed diagnosis of moderate to severe COVID-19 were examined. The last NPS performed ante-mortem confirmed SARS-CoV-2 infection in 12/14 (85.7%) patients. The mean death-to-swab time (DtS) was 3.15 ± 0.5 (2.10–5.1) h. The post-mortem NPS and CS found positive for SARS-CoV-2 RNA were 9/14 (64.3%) and 3/28 (10.7%), respectively. None of the corneal epithelium scrapes tested positive to RT-PCR for SARS-CoV-2 RNA. These data promote the SARS-CoV-2 as not able to contaminate the post-mortem corneal epithelium, while it can persist in different other structures of the ocular surface (i.e., the conjunctiva). It is reasonable to assume that such a contamination can occur ante-mortem too.