Sachin K. Khiste
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sachin K. Khiste has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Faruq Mohammad
College of Science, King Saud University
3 shared publications - Hamad A. Al-Lohedan
Surfactant Research Chair, Chemistry Department, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
2 shared publications - Murthy Chavali
Office of the DEAN (International Relations), PSG College of Arts and Science, Tamil Nadu, Coimbatore, India
2 shared publications - Aisha Nawaf Al Balawi
Biology Department University College of Haql University of Tabuk Tabuk Saudi Arabia
1 shared publication - B. Kunaal Kumar
Department of Mechanical Engineering, Amrita School of Engineering, Bengaluru Campus, Amrita Vishwa Vidyapeetham University, Coimbatore 641112, India
1 shared publication - Fatin Nabilah Mohd Faudzi
Institute of Advanced Technology, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia
1 shared publication
Latest Publications
- Open Access
- 12 November 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (11) , 3039
Investigation of the Tribological Characteristics of Aluminum 6061-Reinforced Titanium Carbide Metal Matrix Composites
The current trend in the materials engineering sector is to develop newer materials that can replace the existing materials in various engineering sectors in order to be more and more efficient. Therefore, the present research work is aimed at fabricating and determining the physical, mechanical, and dry sliding wear properties of titanium carbide (TiC)-reinforced aluminum alloy (Al6061) metal matrix composites (MMCs). For the study, the Al6061-TiC microparticle-reinforced composites were fabricated via the liquid metallurgy route through the stir casting method, where the reinforcement of the TiC particles into the Al6061 alloy matrix was added in the range of 0 to 8.0 wt.%, i.e., in the steps of 2.0 wt.%. The synthesis procedure followed the investigation of the various mechanical properties of Al6061-TiC MMCs, such as the density and structure, as well as mechanical and dry wear experimentation. The tests performed on the casted Al6061, as well as its TiC composites, were in harmony with ASTM standards. As per the experimental outcome, it can be confirmed that the increase in the weight percentage of TiC into the Al6061 alloy substantially increases the density, hardness, and tensile strength, at the expense of the percentage of elongation. In addition, the dry wear experiments, performed on a pin-on-disc tribometer, showed that the Al6061-TiC MMCs have superior wear-resistance properties, as compared to those of pure Al6061 alloy. Furthermore, optical micrograph (OM), powdered X-ray diffraction (XRD), energy dispersive spectroscopy (EDS), and scanning electron microscopy (SEM) analyses were employed for the developed Al6061-TiC MMCs before and after the fracture and wear test studies. From the overall analysis of the results, it can be observed that the Al6061-TiC composite material with higher TiC reinforcement displays superior mechanical characteristics.
- 12 November 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (11) , 3039
Open AccessInvestigation of the Tribological Characteristics of Aluminum 6061-Reinforced Titanium Carbide Metal Matrix Composites
The current trend in the materials engineering sector is to develop newer materials that can replace the existing materials in various engineering sectors in order to be more and more efficient. Therefore, the present research work is aimed at fabricating and determining the physical, mechanical, and dry sliding wear properties of titanium carbide (TiC)-reinforced aluminum alloy (Al6061) metal matrix composites (MMCs). For the study, the Al6061-TiC microparticle-reinforced composites were fabricated via the liquid metallurgy route through the stir casting method, where the reinforcement of the TiC particles into the Al6061 alloy matrix was added in the range of 0 to 8.0 wt.%, i.e., in the steps of 2.0 wt.%. The synthesis procedure followed the investigation of the various mechanical properties of Al6061-TiC MMCs, such as the density and structure, as well as mechanical and dry wear experimentation. The tests performed on the casted Al6061, as well as its TiC composites, were in harmony with ASTM standards. As per the experimental outcome, it can be confirmed that the increase in the weight percentage of TiC into the Al6061 alloy substantially increases the density, hardness, and tensile strength, at the expense of the percentage of elongation. In addition, the dry wear experiments, performed on a pin-on-disc tribometer, showed that the Al6061-TiC MMCs have superior wear-resistance properties, as compared to those of pure Al6061 alloy. Furthermore, optical micrograph (OM), powdered X-ray diffraction (XRD), energy dispersive spectroscopy (EDS), and scanning electron microscopy (SEM) analyses were employed for the developed Al6061-TiC MMCs before and after the fracture and wear test studies. From the overall analysis of the results, it can be observed that the Al6061-TiC composite material with higher TiC reinforcement displays superior mechanical characteristics.
- Open Access
Adsorption, Equilibrium Isotherm, and Thermodynamic Studies towards the Removal of Reactive Orange 16 Dye Using Cu(I)-Polyaninile Composite
To overcome some of the limitations of activated carbon like efficiency, cost-effectiveness, and reusability, the present work deals with Cu(I)-based polyaniline (PANI) composite for the removal of reactive orange 16 (RO16) dye. Following the synthesis and characterization of formed Cu(I)-PANI composite, the batch experiments performed for the removal of RO16 dye indicated that the composite has the capacity to reduce the coloring from RO16. The experiments were conducted for the study of effects against changes in pH, time, and dose at room temperature, where we observed for a pH impact on the dye adsorption capacity in the range of 2–12. Among all, the optimal RO16 removal was found to be 94.77% at a pH of 4 and in addition, the adsorption kinetics confirmed to be pseudo-second-order with more suitability towards the Langmuir isotherm, where it is presumed to be the formation of a monolayer of dye molecule at the homogeneous absorbent surface. The calculated maximum capacity, qm, determined from the Langmuir model was 392.156 mg/g. Further application of isotherms to attain thermodynamic parameters, a slight positive value of ΔS° for RO16 adsorption was observed, meaning that there is an increased randomness in the irregular pattern at the specific Cu(I)-PANI interface for an adsorption process. This mechanism plays an essential role in maintaining the effects of water pollution; and, based on the analysis therefore, it is prominent that the Cu(I)-PANI composite can be employed as a promising and economical adsorbent for the treatment of RO16 and other dye molecules from the sewage in wastewater.
Open AccessAdsorption, Equilibrium Isotherm, and Thermodynamic Studies towards the Removal of Reactive Orange 16 Dye Using Cu(I)-Polyaninile Composite
To overcome some of the limitations of activated carbon like efficiency, cost-effectiveness, and reusability, the present work deals with Cu(I)-based polyaniline (PANI) composite for the removal of reactive orange 16 (RO16) dye. Following the synthesis and characterization of formed Cu(I)-PANI composite, the batch experiments performed for the removal of RO16 dye indicated that the composite has the capacity to reduce the coloring from RO16. The experiments were conducted for the study of effects against changes in pH, time, and dose at room temperature, where we observed for a pH impact on the dye adsorption capacity in the range of 2–12. Among all, the optimal RO16 removal was found to be 94.77% at a pH of 4 and in addition, the adsorption kinetics confirmed to be pseudo-second-order with more suitability towards the Langmuir isotherm, where it is presumed to be the formation of a monolayer of dye molecule at the homogeneous absorbent surface. The calculated maximum capacity, qm, determined from the Langmuir model was 392.156 mg/g. Further application of isotherms to attain thermodynamic parameters, a slight positive value of ΔS° for RO16 adsorption was observed, meaning that there is an increased randomness in the irregular pattern at the specific Cu(I)-PANI interface for an adsorption process. This mechanism plays an essential role in maintaining the effects of water pollution; and, based on the analysis therefore, it is prominent that the Cu(I)-PANI composite can be employed as a promising and economical adsorbent for the treatment of RO16 and other dye molecules from the sewage in wastewater.
- Open Access
- 20 September 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (9) , 2446
Aptasensor for the Detection of Mycobacterium tuberculosis in Sputum Utilising CFP10-ESAT6 Protein as a Selective Biomarker
A portable electrochemical aptamer-antibody based sandwich biosensor has been designed and successfully developed using an aptamer bioreceptor immobilized onto a screen-printed electrode surface for Mycobacterium tuberculosis (M. tuberculosis) detection in clinical sputum samples. In the sensing strategy, a CFP10-ESAT6 binding aptamer was immobilized onto a graphene/polyaniline (GP/PANI)-modified gold working electrode by covalent binding via glutaraldehyde linkage. Upon interaction with the CFP10-ESAT6 antigen target, the aptamer will capture the target where the nano-labelled Fe3O4/Au MNPs conjugated antibody is used to complete the sandwich format and enhance the signal produced from the aptamer–antigen interaction. Using this strategy, the detection of CFP10-ESAT6 antigen was conducted in the concentration range of 5 to 500 ng/mL. From the analysis, the detection limit was found to be 1.5 ng/mL, thereby demonstrating the efficiency of the aptamer as a bioreceptor. The specificity study was carried out using bovine serum albumin (BSA), MPT64, and human serum, and the result demonstrated good specificity that is 7% higher than the antibody–antigen interaction reported in a previous study. The fabricated aptasensor for M. tuberculosis analysis shows good reproducibility with an relative standard deviation (RSD) of 2.5%. Further analysis of M. tuberculosis in sputum samples have shown good correlation with the culture method with 100% specificity and sensitivity, thus making the aptasensor a promising candidate for M. tuberculosis detection considering its high specificity and sensitivity with clinical samples.
- 20 September 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (9) , 2446
Open AccessAptasensor for the Detection of Mycobacterium tuberculosis in Sputum Utilising CFP10-ESAT6 Protein as a Selective Biomarker
A portable electrochemical aptamer-antibody based sandwich biosensor has been designed and successfully developed using an aptamer bioreceptor immobilized onto a screen-printed electrode surface for Mycobacterium tuberculosis (M. tuberculosis) detection in clinical sputum samples. In the sensing strategy, a CFP10-ESAT6 binding aptamer was immobilized onto a graphene/polyaniline (GP/PANI)-modified gold working electrode by covalent binding via glutaraldehyde linkage. Upon interaction with the CFP10-ESAT6 antigen target, the aptamer will capture the target where the nano-labelled Fe3O4/Au MNPs conjugated antibody is used to complete the sandwich format and enhance the signal produced from the aptamer–antigen interaction. Using this strategy, the detection of CFP10-ESAT6 antigen was conducted in the concentration range of 5 to 500 ng/mL. From the analysis, the detection limit was found to be 1.5 ng/mL, thereby demonstrating the efficiency of the aptamer as a bioreceptor. The specificity study was carried out using bovine serum albumin (BSA), MPT64, and human serum, and the result demonstrated good specificity that is 7% higher than the antibody–antigen interaction reported in a previous study. The fabricated aptasensor for M. tuberculosis analysis shows good reproducibility with an relative standard deviation (RSD) of 2.5%. Further analysis of M. tuberculosis in sputum samples have shown good correlation with the culture method with 100% specificity and sensitivity, thus making the aptasensor a promising candidate for M. tuberculosis detection considering its high specificity and sensitivity with clinical samples.