Lei Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lei Li has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Qingmiao Yang
College of Chemical Engineering, Sichuan University of Science and Engineering, Zigong 643000, China
2 shared publications - Caijing Xie
School of Chemical Engineering, Sichuan University of Science and Engineering, Zigong 643000, China
1 shared publication - Chenxi Xu
School of Chemical Engineering, Sichuan University of Science and Engineering, Zigong 643000, China
1 shared publication - Hong-Ying Liu
School of Chemical and Environmental Engineering, China University of Mining & Technology, Haidian District, China
1 shared publication Jie Liu
School of Chemical and Environmental Engineering, China University of Mining & Technology, Haidian District, China
1 shared publication- Jie Liu
College of Petroleum Engineering, Liaoning Petrochemical University, Fushun 113001, China
1 shared publication
Latest Publications
- Open Access
Numerical Simulation Analysis of Cu2+ Concentration for Marine Biological Control Based on Seawater Lifting Pump
To prevent marine biofouling in seawater lift pumps, electrolyzed seawater containing Cu2+ needs to be injected into the pumps. This study employs Computational Fluid Dynamics (CFD) to simulate the variation in Cu2+ injection concentration required to achieve a Cu2+ concentration of 3 ppb within a 10 cm range around the pump under different operating conditions, including the installation of baffles and varying seawater flow rates. The simulation results demonstrate that CFD can accurately predict the distribution of Cu2+ concentration in electrolyzed seawater, with the distribution significantly influenced by seawater flow direction, necessitating reference to upstream data. When the lift pumps are idle, the required Cu2+ injection concentration increases with rising seawater flow rates, reaching 41.9 μg/L at the maximum flow rate of 1.9 m/s. During alternating pump operation, the required Cu2+ injection concentration also increases with the flow rate, significantly affected by the pump’s operational position: lower concentrations are required when the upstream pump is active compared to the downstream pump. Additionally, installing baffles around the pumps effectively mitigates the impact of seawater flow on Cu2+ distribution, significantly reducing the required injection concentration. This study provides theoretical and data-driven insights for optimising marine biofouling prevention in seawater lift pumps.
Open AccessNumerical Simulation Analysis of Cu2+ Concentration for Marine Biological Control Based on Seawater Lifting Pump
To prevent marine biofouling in seawater lift pumps, electrolyzed seawater containing Cu2+ needs to be injected into the pumps. This study employs Computational Fluid Dynamics (CFD) to simulate the variation in Cu2+ injection concentration required to achieve a Cu2+ concentration of 3 ppb within a 10 cm range around the pump under different operating conditions, including the installation of baffles and varying seawater flow rates. The simulation results demonstrate that CFD can accurately predict the distribution of Cu2+ concentration in electrolyzed seawater, with the distribution significantly influenced by seawater flow direction, necessitating reference to upstream data. When the lift pumps are idle, the required Cu2+ injection concentration increases with rising seawater flow rates, reaching 41.9 μg/L at the maximum flow rate of 1.9 m/s. During alternating pump operation, the required Cu2+ injection concentration also increases with the flow rate, significantly affected by the pump’s operational position: lower concentrations are required when the upstream pump is active compared to the downstream pump. Additionally, installing baffles around the pumps effectively mitigates the impact of seawater flow on Cu2+ distribution, significantly reducing the required injection concentration. This study provides theoretical and data-driven insights for optimising marine biofouling prevention in seawater lift pumps.
- Open Access
Preparation and Flame-Retardant Mechanism of MgAlZn-Based Hydrotalcite-like Coal Spontaneous Combustion Inhibitor
In this work, the coprecipitation approach was successfully used to create Mg-Al hydrotalcite-like inhibitors modified with varying amounts of Zn, and their characteristics were assessed. The findings indicate that the flame retardancy of Mg-Al hydrotalcite (MgAl-LDHs) is not significantly affected by Zn content. By adding MgAl-LDHs, the temperature at which the exothermic reaction started to occur was raised from 146.2 °C to 193.6 °C, according to the test of spontaneous combustion tendency. In the excavation route, the utility model can serve as a temporary fire prevention and extinguishment tool. Furthermore, the analysis of the functional group changes during the reaction was conducted using FTIR. After applying MgAl-LDHs, the oxidation of organic groups on the coal surface was clearly prevented, indicating that the inhibitor had a substantial flame-retardant effect on coal. In conclusion, this work creates a material that resembles hydrotalcite and is easy to use, inexpensive, and effective in preventing coal from spontaneously combusting.
Open AccessPreparation and Flame-Retardant Mechanism of MgAlZn-Based Hydrotalcite-like Coal Spontaneous Combustion Inhibitor
In this work, the coprecipitation approach was successfully used to create Mg-Al hydrotalcite-like inhibitors modified with varying amounts of Zn, and their characteristics were assessed. The findings indicate that the flame retardancy of Mg-Al hydrotalcite (MgAl-LDHs) is not significantly affected by Zn content. By adding MgAl-LDHs, the temperature at which the exothermic reaction started to occur was raised from 146.2 °C to 193.6 °C, according to the test of spontaneous combustion tendency. In the excavation route, the utility model can serve as a temporary fire prevention and extinguishment tool. Furthermore, the analysis of the functional group changes during the reaction was conducted using FTIR. After applying MgAl-LDHs, the oxidation of organic groups on the coal surface was clearly prevented, indicating that the inhibitor had a substantial flame-retardant effect on coal. In conclusion, this work creates a material that resembles hydrotalcite and is easy to use, inexpensive, and effective in preventing coal from spontaneously combusting.
- 21 September 2021
- Published by Springer Nature in Chemistry and Technology of Fuels and Oils
- Vol. 57 (4) , 705-712
Experimental Research on a Cyclone Air Flotation Separator for Polymer-Containing Wastewater
- 21 September 2021
- Published by Springer Nature in Chemistry and Technology of Fuels and Oils
- Vol. 57 (4) , 705-712
Experimental Research on a Cyclone Air Flotation Separator for Polymer-Containing Wastewater