Narges Torabi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Narges Torabi has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
H. Burak Gunay
2 shared publicationsRicardo Moromisato
CopperTree Analytics, Vancouver, BC, Canada
2 shared publicationsWilliam O'BRien
Carleton University
2 shared publications- Burak Gunay
Carleton University, Ottawa, Canada
1 shared publication H Burak Gunay
Carleton University
1 shared publicationHuseyin Burak Gunay
Department of Civil and Environmental Engineering, Carleton University, Ottawa, ON, Canada
1 shared publication
Latest Publications
- Open Access
- 20 July 2024
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 33 (9) , 1665-1679
A simulation-based investigation of the robustness of sequences of operation to zone-level faults in single-duct multi-zone variable air volume air handling unit systems
High-performance sequences of operation for variable air volume (VAV) air handling units (AHUs) respond to requests from zones, leaving these sequences vulnerable to faults that occur at the zone level. While prior research has shown that ASHRAE Guideline 36 reduces energy consumption, its ability to withstand zone-level faults is understudied. This paper investigates the fault tolerance of supply air temperature (SAT) setpoint, duct static pressure (DSP) setpoint and mode of operation (MOP) in single-duct multi-zone VAV AHUs. First, customized sequences were defined for different scenarios in EnergyPlus in this study. Then, common actuator/sensor faults were injected into one zone to identify the most efficient fault-tolerant scenario. The results indicate that trim and respond reset logic is the most fault-tolerant scenario for this paper’s case study, with a 12% energy use intensity (EUI) increase for the SAT setpoint and an 11% increase for the DSP setpoint. Moreover, implementing an average temperature–based control for MOP significantly reduces the setup/setback mode activation, resulting in a lower EUI.
- 20 July 2024
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 33 (9) , 1665-1679
Open AccessA simulation-based investigation of the robustness of sequences of operation to zone-level faults in single-duct multi-zone variable air volume air handling unit systems
High-performance sequences of operation for variable air volume (VAV) air handling units (AHUs) respond to requests from zones, leaving these sequences vulnerable to faults that occur at the zone level. While prior research has shown that ASHRAE Guideline 36 reduces energy consumption, its ability to withstand zone-level faults is understudied. This paper investigates the fault tolerance of supply air temperature (SAT) setpoint, duct static pressure (DSP) setpoint and mode of operation (MOP) in single-duct multi-zone VAV AHUs. First, customized sequences were defined for different scenarios in EnergyPlus in this study. Then, common actuator/sensor faults were injected into one zone to identify the most efficient fault-tolerant scenario. The results indicate that trim and respond reset logic is the most fault-tolerant scenario for this paper’s case study, with a 12% energy use intensity (EUI) increase for the SAT setpoint and an 11% increase for the DSP setpoint. Moreover, implementing an average temperature–based control for MOP significantly reduces the setup/setback mode activation, resulting in a lower EUI.
- 23 June 2022
- Published by Elsevier in Building and Environment
- Vol. 221, 109333
Common human errors in design, installation, and operation of VAV AHU control systems – A review and a practitioner interview
- 23 June 2022
- Published by Elsevier in Building and Environment
- Vol. 221, 109333
Common human errors in design, installation, and operation of VAV AHU control systems – A review and a practitioner interview
- Open Access
- 6 June 2022
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 43 (5) , 605-625
A holistic sequential fault detection and diagnostics framework for multiple zone variable air volume air handling unit systems
A holistic fault detection and diagnostics (FDD) method should explicitly consider the dependencies between faults at the system- and zone-level to isolate the root cause. A system-level fault can trigger false alarms at the zone-level, while concealing the presence of a zone-level fault. However, most FDD methods have focused on a single component/equipment without considering the importance of the interactions between zone- and system-level devices. This paper proposes a holistic hierarchical framework for FDD, combining the process of detection and diagnosis of controls hardware and sequencing logic faults affecting the actuators at the system- and zone-level. The proposed framework follows a holistic sequential procedure to diagnose faults and suppress false alarms in this order: hard faults in air handling units (AHUs), hard faults in variable air volume (VAV) zones, sequencing logic faults in AHUs, and sequencing logic faults in VAV zones. The detection of faults is performed by visualizing the discrepancies between the expected and measured operational behaviour of AHUs and VAV boxes. Examples demonstrating the framework are provided with data from 10 different VAV AHU systems. Practical application: This paper provides a sequential hierarchical FDD framework to address two main issues in VAV AHU systems: detectability and significance. Regarding detectability, the framework prioritizes hard faults over sequencing logic faults to avoid false positives and false negatives; about significance, system-level faults are prioritized over zone-level faults to triage high-impact faults in the system. The detection of faults is performed via visualizing the biases from the expected behaviour of AHU and VAV characteristics to provide an envisioning interpretation for the experts in facilities management in commercial buildings to find the root cause of the fault and fix them on-site.
- 6 June 2022
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 43 (5) , 605-625
Open AccessA holistic sequential fault detection and diagnostics framework for multiple zone variable air volume air handling unit systems
A holistic fault detection and diagnostics (FDD) method should explicitly consider the dependencies between faults at the system- and zone-level to isolate the root cause. A system-level fault can trigger false alarms at the zone-level, while concealing the presence of a zone-level fault. However, most FDD methods have focused on a single component/equipment without considering the importance of the interactions between zone- and system-level devices. This paper proposes a holistic hierarchical framework for FDD, combining the process of detection and diagnosis of controls hardware and sequencing logic faults affecting the actuators at the system- and zone-level. The proposed framework follows a holistic sequential procedure to diagnose faults and suppress false alarms in this order: hard faults in air handling units (AHUs), hard faults in variable air volume (VAV) zones, sequencing logic faults in AHUs, and sequencing logic faults in VAV zones. The detection of faults is performed by visualizing the discrepancies between the expected and measured operational behaviour of AHUs and VAV boxes. Examples demonstrating the framework are provided with data from 10 different VAV AHU systems. Practical application: This paper provides a sequential hierarchical FDD framework to address two main issues in VAV AHU systems: detectability and significance. Regarding detectability, the framework prioritizes hard faults over sequencing logic faults to avoid false positives and false negatives; about significance, system-level faults are prioritized over zone-level faults to triage high-impact faults in the system. The detection of faults is performed via visualizing the biases from the expected behaviour of AHU and VAV characteristics to provide an envisioning interpretation for the experts in facilities management in commercial buildings to find the root cause of the fault and fix them on-site.
- 1 December 2021
- Published by Elsevier in Energy and Buildings
- Vol. 253
Inverse model-based virtual sensors for detection of hard faults in air handling units
- 1 December 2021
- Published by Elsevier in Energy and Buildings
- Vol. 253
Inverse model-based virtual sensors for detection of hard faults in air handling units
- Open Access
- 1 November 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2042 (1) , 012130
A review of common human errors in design, installation, and operation of multiple-zone VAV AHU systems
Faults in air-based heating, ventilation, and air conditioning (HVAC) systems lead to energy waste and discomfort. While the emphasis of fault detection and diagnostic (FDD) research has been on hard faults in actuators, sensors, and equipment, faults arising from human errors account for a significant portion of faults occurring in HVAC systems. In this paper, human errors occurring in air handling units (AHUs) and variable air volume (VAV) thermal zones during design, construction, and operation phases are identified through a review of the literature. Then, the faults are divided into six main categories. Based on case studies investigating these faults, the impact of each fault category on occupant comfort, energy consumption, and equipment life is discussed. The authors provide recommendations to minimize human errors in AHUs and VAV zones throughout the building life cycle.
- 1 November 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2042 (1) , 012130
Open AccessA review of common human errors in design, installation, and operation of multiple-zone VAV AHU systems
Faults in air-based heating, ventilation, and air conditioning (HVAC) systems lead to energy waste and discomfort. While the emphasis of fault detection and diagnostic (FDD) research has been on hard faults in actuators, sensors, and equipment, faults arising from human errors account for a significant portion of faults occurring in HVAC systems. In this paper, human errors occurring in air handling units (AHUs) and variable air volume (VAV) thermal zones during design, construction, and operation phases are identified through a review of the literature. Then, the faults are divided into six main categories. Based on case studies investigating these faults, the impact of each fault category on occupant comfort, energy consumption, and equipment life is discussed. The authors provide recommendations to minimize human errors in AHUs and VAV zones throughout the building life cycle.