MWMark G. E. White

Mark G. E. White

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mark G. E. White has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A novel measure to quantify technical ability in on-water rowing

    by Sam Jones, Chris Bailey, Dave Thomas, Mark G.E. White, Paul Rees, Huw D. Summers, Neil E. Bezodis

    This study developed a new measure that quantifies technical ability in on-water rowing by accounting for the effects of an athlete's physiological capabilities and the given environmental conditions. Maximal 2000 m efforts for both ergometer and on-water (n = 340 of each) were collected from 162 national and international athletes (78 women, 84 men) over 16 years. A linear mixed model predicted on-water performance from static ergometer performance (physiological capability), accounting for day of on-water testing (environmental condition effects). On-water delta was the difference between predicted and actual on-water performance. The model revealed significant fixed effects (intercept = 17.70 s, 95% CI = [8.43, 26.97], p < 0.001; ergometer coefficient = 0.87, 95% CI = [0.81, 0.93], p < 0.001), and random effects for year ranged from -15.43 s to 47.98 s (median = -6.29 s). On-water delta ranged from -32.8 s (faster than predicted) to 51.1 s (slower). On-water delta provides a new dependent variable that can be used to quantify technical ability in future investigations. The current data provide contextual on-water delta values from a large sample of high-level athletes, and the outlined modelling approach can be applied to new datasets to provide population-specific quantifications of technical ability.


  • Open Access

    Wearable Sensors for Athletic Performance: A Comparison of Discrete and Continuous Feature-Extraction Methods for Prediction Models

    by Mark White, Beatrice De Lazzari, Neil Bezodis, Valentina Camomilla

    Wearable sensors have become increasingly popular for assessing athletic performance, but the optimal methods for processing and analyzing the data remain unclear. This study investigates the efficacy of discrete and continuous feature-extraction methods, separately and in combination, for modeling countermovement jump performance using wearable sensor data. We demonstrate that continuous features, particularly those derived from Functional Principal Component Analysis, outperform discrete features in terms of model performance, robustness to variations in data distribution and volume, and consistency across different datasets. Our findings underscore the importance of methodological choices, such as signal type, alignment methods, and model selection, in developing accurate and generalizable predictive models. We also highlight the potential pitfalls of relying solely on domain knowledge for feature selection and the benefits of data-driven approaches. Furthermore, we discuss the implications of our findings for the broader field of sports biomechanics and provide practical recommendations for researchers and practitioners aiming to leverage wearable sensor data for athletic performance assessment. Our results contribute to the development of more reliable and widely applicable predictive models, facilitating the use of wearable technology for optimizing training and enhancing athletic outcomes across various sports disciplines.


  • Open Access

    Wearable Sensors for Athletic Performance: A Comparison of Discrete and Continuous Feature Extraction Methods for Prediction Models

    by Mark White, Beatrice De Lazzari, Neil Bezodis, Valentina Camomilla

    Wearable sensors have become increasingly popular for assessing athletic performance, but the optimal methods for processing and analysing the data remain unclear. This study investigates the efficacy of discrete and continuous feature extraction methods, separately and in combination, for modelling countermovement jump performance using wearable sensor data. We demonstrate that continuous features, particularly those derived from Functional Principal Component Analysis, outperform discrete features in terms of model performance, robustness to variations in data distribution and volume, and consistency across different datasets. Our findings underscore the importance of methodological choices, such as signal type, alignment methods, and model selection, in developing accurate and generalisable predictive models. We also highlight the potential pitfalls of relying solely on domain knowledge for feature selection and the benefits of data-driven approaches. Furthermore, we discuss the implications of our findings for the broader field of sports biomechanics and provide practical recommendations for researchers and practitioners aiming to leverage wearable sensor data for athletic performance assessment. Our results contribute to the development of more reliable and widely applicable predictive models, facilitating the use of wearable technology for optimising training and enhancing athletic outcomes across various sports disciplines.


  • Open Access

    Determining jumping performance from a single body-worn accelerometer using machine learning

    by Mark G. E. White, Neil E. Bezodis, Jonathon Neville, Huw Summers, Paul Rees

    External peak power in the countermovement jump is frequently used to monitor athlete training. The gold standard method uses force platforms, but they are unsuitable for field-based testing. However, alternatives based on jump flight time or Newtonian methods applied to inertial sensor data have not been sufficiently accurate for athlete monitoring. Instead, we developed a machine learning model based on characteristic features (functional principal components) extracted from a single body-worn accelerometer. Data were collected from 69 male and female athletes at recreational, club or national levels, who performed 696 jumps in total. We considered vertical countermovement jumps (with and without arm swing), sensor anatomical locations, machine learning models and whether to use resultant or triaxial signals. Using a novel surrogate model optimisation procedure, we obtained the lowest errors with a support vector machine when using the resultant signal from a lower back sensor in jumps without arm swing. This model had a peak power RMSE of 2.3 W·kg-1(5.1% of the mean), estimated using nested cross validation and supported by an independent holdout test (2.0 W·kg-1). This error is lower than in previous studies, although it is not yet sufficiently accurate for a field-based method. Our results demonstrate that functional data representations work well in machine learning by reducing model complexity in applications where signals are aligned in time. Our optimisation procedure also was shown to be robust can be used in wider applications with low-cost, noisy objective functions.


  • Generalisable FPCA-based Models for Predicting Peak Power in Vertical Jumping using Accelerometer Data

    by Mark G. E. White

    Peak power in the countermovement jump is correlated with various measures of sports performance and can be used to monitor athlete training. The gold standard method for determining peak power uses force platforms, but they are unsuitable for field-based testing favoured by practitioners. Alternatives include predicting peak power from jump flight times, or using Newtonian methods based on body-worn inertial sensor data, but so far neither has yielded sufficiently accurate estimates. This thesis aims to develop a generalisable model for predicting peak power based on Functional Principal Component Analysis applied to body-worn accelerometer data. Data was collected from 69 male and female adults, engaged in sports at recreational, club or national levels. They performed up to 16 countermovement jumps each, with and without arm swing, 696 jumps in total. Peak power criterion measures were obtained from force platforms, and characteristic features from accelerometer data were extracted from four sensors attached to the lower back, upper back and both shanks. The best machine learning algorithm, jump type and sensor anatomical location were determined in this context. The investigation considered signal representation (resultant, triaxial or a suitable transform), preprocessing (smoothing, time window and curve registration), feature selection and data augmentation (signal rotations and SMOTER). A novel procedure optimised the model parameters based on Particle Swarm applied to a surrogate Gaussian Process model. Model selection and evaluation were based on nested cross validation (Monte Carlo design). The final optimal model had an RMSE of 2.5 W·kg-1, which compares favourably to earlier research (4.9 ± 1.7 W·kg-1 for flight-time formulae and 10.7 ± 6.3 W·kg-1 for Newtonian sensor-based methods). Whilst this is not yet sufficiently accurate for applied practice, this thesis has developed and comprehensively evaluated new techniques, which will be valuable to future biomechanical applications.

  • Open Access

    Determining jumping performance from a single body-worn accelerometer using machine learning

    by Mark White, Neil Bezodis, Jonathon Neville, Huw Summers, Paul Rees

    External peak power in the countermovement jump is frequently used to monitor athlete training. The gold standard method uses force platforms, but they are unsuitable for field-based testing. However, alternatives based on jump flight time or Newtonian methods applied to inertial sensor data have not been sufficiently accurate for athlete monitoring. Instead, we developed a machine learning model based on characteristic features (functional principal components) extracted from a single body-worn accelerometer. Data were collected from 69 male and female athletes at recreational, club or national levels, who performed 696 jumps in total. We considered vertical countermovement jumps (with and without arm swing), sensor anatomical locations, machine learning models and whether to use resultant or triaxial signals. Using a novel surrogate model optimisation procedure, we obtained the lowest errors with a support vector machine when using the resultant signal from a lower back sensor in jumps without arm swing. This model had a peak power RMSE of 2.3 W·kg-1 (5.1% of the mean), estimated using nested cross validation and supported by an independent holdout test (2.0 W·kg-1). This error is lower than in previous studies, although it is not yet sufficiently accurate for a field-based method. Our results demonstrate that functional data representations work well in machine learning by reducing model complexity in applications where signals are aligned in time. Our optimisation procedure also was shown to be robust can be used in wider applications with low-cost, noisy objective functions.