Job Nicolaas Doornberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Job Nicolaas Doornberg has a total of 352 co-authors. Here are the top co-authors by number of shared publications:
- Frank F. A. Ijpma
Department of Trauma Surgery, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
28 shared publications - Ruurd Lucas Jaarsma
Department of Orthopaedic & Trauma Surgery, Flinders University, Flinders Medical Centre, Adelaide, Australia
27 shared publications - Kaj Ten Duis
Department of Trauma Surgery, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
14 shared publications - Nick Assink
Department of Trauma Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
12 shared publications - Paul Christiaan Jutte
Department of Orthopaedic Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
12 shared publications - Anne M. L. Meesters
D Lab, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
8 shared publications
Latest Publications
- Open Access
- 16 October 2026
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14, e94586
Three Ambient Listening Systems in Simulated Dutch-Language Multispeaker and Multidialect Clinical Encounters: Comparative Study
Background: Clinicians spend a lot of time on electronic health record (EHR) documentation, often at the expense of direct patient interaction. Ambient listening technology uses AI to passively record and summarize clinical encounters. Although early studies are promising, there is limited evidence on system performance in complex, non-English settings. Objective: This study aimed to compare the documentation performance of 3 commercially available ambient listening systems in simulated Dutch-language outpatient consultations by assessing note completeness, correctness, and conciseness under predefined linguistic and interactional challenges. Methods: Standardized audio recordings of 10 scripted physician-patient interactions across 2 specialties were used. Scenarios included multispeaker dynamics (patient companion), conversational disruptions (nurse interruption), evasive patient communication, and a regional dialect (Gronings). Three ambient listening providers (provider 1, provider 2, and provider 3) processed the audio files. Generated notes were divided into 4 note sections: patient history, physical examination, diagnostic impression, and treatment plan. For each system output, each note section was scored for completeness, conciseness, and correctness using a 5-point ordinal scale against physician-developed reference summaries. In total, 8 clinicians participated in scoring: 4 junior clinicians evaluated all outputs, and 4 senior clinicians each reviewed a subset of scenarios. Analyses were based on 351 rater-averaged section-domain scores. Interrater agreement was assessed using Gwet agreement coefficient 2 (Gwet AC-2). System-level technical characteristics were assessed alongside clinical performance to aid interpretation of between-provider differences. Results: Across 351 rater-averaged section-domain scores on a 5-point scale, overall interrater agreement was high (Gwet AC-2=0.827). Provider-level mean scores ranged from 3.82 to 4.26 (4.26, SD 0.73 for provider 3, 4.00, SD 0.90 for provider 2, and 3.82, SD 1.07 for provider 1). Mean scores were higher in otolaryngology than in surgical oncology (4.36, SD 0.56 vs 3.68, SD 1.10). Across scoring domains, correctness received the highest mean score (4.21, SD 0.98), while completeness received the lowest (3.81, SD 0.90). Variation in mean scores was observed across script scenarios. Dialect-containing scenarios had the lowest mean score overall (3.77, SD 1.21), although this pattern was not uniform across specialties and systems. Median summary generation times ranged from 13.5 seconds (IQR 12-15; provider 3) to 22.0 seconds (IQR 18-24; provider 2). Conclusions: Ambient listening systems demonstrated generally strong performance in this simulated Dutch-language evaluation, including under several common conversational challenges. However, mean scores varied across scripted scenarios, with lower scores observed in some dialect-containing and otherwise challenging interactions. Future deployment studies must prioritize linguistic equity, real-world validation of efficiency gains, and evaluation of both clinician and patient perceptions to understand how these systems influence consultation dynamics and care delivery across diverse patient populations.
- 16 October 2026
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14, e94586
Open AccessThree Ambient Listening Systems in Simulated Dutch-Language Multispeaker and Multidialect Clinical Encounters: Comparative Study
Background: Clinicians spend a lot of time on electronic health record (EHR) documentation, often at the expense of direct patient interaction. Ambient listening technology uses AI to passively record and summarize clinical encounters. Although early studies are promising, there is limited evidence on system performance in complex, non-English settings. Objective: This study aimed to compare the documentation performance of 3 commercially available ambient listening systems in simulated Dutch-language outpatient consultations by assessing note completeness, correctness, and conciseness under predefined linguistic and interactional challenges. Methods: Standardized audio recordings of 10 scripted physician-patient interactions across 2 specialties were used. Scenarios included multispeaker dynamics (patient companion), conversational disruptions (nurse interruption), evasive patient communication, and a regional dialect (Gronings). Three ambient listening providers (provider 1, provider 2, and provider 3) processed the audio files. Generated notes were divided into 4 note sections: patient history, physical examination, diagnostic impression, and treatment plan. For each system output, each note section was scored for completeness, conciseness, and correctness using a 5-point ordinal scale against physician-developed reference summaries. In total, 8 clinicians participated in scoring: 4 junior clinicians evaluated all outputs, and 4 senior clinicians each reviewed a subset of scenarios. Analyses were based on 351 rater-averaged section-domain scores. Interrater agreement was assessed using Gwet agreement coefficient 2 (Gwet AC-2). System-level technical characteristics were assessed alongside clinical performance to aid interpretation of between-provider differences. Results: Across 351 rater-averaged section-domain scores on a 5-point scale, overall interrater agreement was high (Gwet AC-2=0.827). Provider-level mean scores ranged from 3.82 to 4.26 (4.26, SD 0.73 for provider 3, 4.00, SD 0.90 for provider 2, and 3.82, SD 1.07 for provider 1). Mean scores were higher in otolaryngology than in surgical oncology (4.36, SD 0.56 vs 3.68, SD 1.10). Across scoring domains, correctness received the highest mean score (4.21, SD 0.98), while completeness received the lowest (3.81, SD 0.90). Variation in mean scores was observed across script scenarios. Dialect-containing scenarios had the lowest mean score overall (3.77, SD 1.21), although this pattern was not uniform across specialties and systems. Median summary generation times ranged from 13.5 seconds (IQR 12-15; provider 3) to 22.0 seconds (IQR 18-24; provider 2). Conclusions: Ambient listening systems demonstrated generally strong performance in this simulated Dutch-language evaluation, including under several common conversational challenges. However, mean scores varied across scripted scenarios, with lower scores observed in some dialect-containing and otherwise challenging interactions. Future deployment studies must prioritize linguistic equity, real-world validation of efficiency gains, and evaluation of both clinician and patient perceptions to understand how these systems influence consultation dynamics and care delivery across diverse patient populations.
- Open Access
- 13 October 2026
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 7 (10) , 1304-1311
Substantial improvement in short-term survivorship in patients receiving robotic arm-assisted medial unicompartmental knee arthroplasty
Aims: Robotic arm-assisted unicompartmental knee arthroplasty (R-UKA) has been shown to improve alignment and accuracy of component placement compared with conventional unicompartmental knee arthroplasty (C-UKA). Despite this, there is conflicting evidence for whether this has an impact on revision rates. Methods: We performed a retrospective analysis of a prospective database, comparing patients who underwent R-UKA using the Stryker Restoris MCK implant with those who underwent C-UKA using the cemented Oxford Partial Knee implant, between January 2002 and December 2024 at The Prince Charles Hospital (Brisbane, Australia), with a minimum six-month follow-up. Patient selection for UKA mirrored the recommendations by Kozinn and Scott. The primary outcome of interest was to compare the all-cause revision rate between these two groups. Secondary outcomes of interest were to compare hospital length of stay (HLOS), surgical duration, the odds of superficial surgical site infection, and the odds of periprosthetic joint infection (PJI) between the same groups. The analysis of individual outcomes were adjusted for age, sex, BMI, American Society of Anesthesiologists grade, Charlson Comorbidity Index, and primary surgeon grade. Results: The hazard of all-cause revision significantly decreased by 78% in the R-UKA group as compared with the C-UKA group (p = 0.046). HLOS was also significantly shorter by 2.2 days (95% CI 1.0 to 3.3) in the R-UKA group (p < 0.001). There was no significant difference in the surgical duration (p = 0.733), odds of superficial surgical site infection (p = 0.845), nor in the odds of PJI (p = 0.415) between the two groups. Conclusion: The substantial improvement in revision outcomes suggests that R-UKA is the option of choice for managing symptomatic unicompartmental knee arthritis in carefully selected patients with isolated medial compartmental osteoarthritis, especially in the hands of low-volume surgeons. Decreased HLOS should be interpreted with caution, given the non-contemporaneous nature of the two cohorts. Cite this article: Bone Jt Open 2026;7(10):1304–1311.
- 13 October 2026
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 7 (10) , 1304-1311
Open AccessSubstantial improvement in short-term survivorship in patients receiving robotic arm-assisted medial unicompartmental knee arthroplasty
Aims: Robotic arm-assisted unicompartmental knee arthroplasty (R-UKA) has been shown to improve alignment and accuracy of component placement compared with conventional unicompartmental knee arthroplasty (C-UKA). Despite this, there is conflicting evidence for whether this has an impact on revision rates. Methods: We performed a retrospective analysis of a prospective database, comparing patients who underwent R-UKA using the Stryker Restoris MCK implant with those who underwent C-UKA using the cemented Oxford Partial Knee implant, between January 2002 and December 2024 at The Prince Charles Hospital (Brisbane, Australia), with a minimum six-month follow-up. Patient selection for UKA mirrored the recommendations by Kozinn and Scott. The primary outcome of interest was to compare the all-cause revision rate between these two groups. Secondary outcomes of interest were to compare hospital length of stay (HLOS), surgical duration, the odds of superficial surgical site infection, and the odds of periprosthetic joint infection (PJI) between the same groups. The analysis of individual outcomes were adjusted for age, sex, BMI, American Society of Anesthesiologists grade, Charlson Comorbidity Index, and primary surgeon grade. Results: The hazard of all-cause revision significantly decreased by 78% in the R-UKA group as compared with the C-UKA group (p = 0.046). HLOS was also significantly shorter by 2.2 days (95% CI 1.0 to 3.3) in the R-UKA group (p < 0.001). There was no significant difference in the surgical duration (p = 0.733), odds of superficial surgical site infection (p = 0.845), nor in the odds of PJI (p = 0.415) between the two groups. Conclusion: The substantial improvement in revision outcomes suggests that R-UKA is the option of choice for managing symptomatic unicompartmental knee arthritis in carefully selected patients with isolated medial compartmental osteoarthritis, especially in the hands of low-volume surgeons. Decreased HLOS should be interpreted with caution, given the non-contemporaneous nature of the two cohorts. Cite this article: Bone Jt Open 2026;7(10):1304–1311.
- Open Access
- 22 August 2026
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 6 (4)
What is the preferred timing for surgery after proximal humerus fractures: an e-modified Delphi Survey Study
- 22 August 2026
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 6 (4)
Open AccessWhat is the preferred timing for surgery after proximal humerus fractures: an e-modified Delphi Survey Study
- Open Access
- 14 August 2026
- Published by Elsevier in JSES International
- Vol. 10 (6) , 101784
Corrective osteotomies of malunited proximal humerus fractures with 3D patient-specific guides: a feasibility study
- 14 August 2026
- Published by Elsevier in JSES International
- Vol. 10 (6) , 101784
Open AccessCorrective osteotomies of malunited proximal humerus fractures with 3D patient-specific guides: a feasibility study
- Open Access
- 24 June 2026
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 36 (1) , 249
Development of intraoperative fluoroscopic protocols to avoid rotational malalignment during nailing of femoral fractures: a step-by-step guideline using the lesser trochanter profile or true lateral view
Purpose: Rotational malalignment (≥ 15°) occurs in up to 35% of femoral fractures after intramedullary nailing, and standardized fluoroscopy protocols to prevent malrotation are lacking. We developed and evaluated two easy-to-use intraoperative fluoroscopy techniques to reduce malrotation. Methods: A human specimen study was performed to compare two standardized fluoroscopy protocols—the lesser trochanter profile and the true lateral view—with current clinical practice. A mid-shaft femoral fracture was created in a full-body cadaver, and an unlocked intramedullary nail was inserted. Random degrees of rotational malalignment were applied using a goniometer and reference wires at the fracture site. Ten physicians (consultants and residents) first estimated malrotation and then performed 150 rotational corrections: 50 according to (unstandardized) clinical practice, 50 using the lesser trochanter profile, and 50 using the true lateral view. The primary outcome was rotational malalignment, measured using reference wires at the fracture site. Results: Clinicians’ visual estimation deviated 15.5° [IQR 18.5–12.0] from actual malrotation. Corrections using unstandardized methods resulted in 12.5° [IQR 18.2–6.1] of malrotation. In contrast, the lesser trochanter and true lateral protocols reduced malrotation to 3.9° [6.8–2.1] and 3.6° [8.6–1.4], respectively. Both were significantly more accurate than current practice ( p = 0.009 and p = 0.017). Surgeons favoured the lesser trochanter profile for its efficiency, ease-to-use, and minimal need for C-arm repositioning. Conclusion: This study introduces two step-by-step standardized fluoroscopy protocols to prevent rotational malalignment in femoral nailing. Both outperform traditional, unstandardized correction methods, with the lesser trochanter profile offering a more practical and time-efficient option for intraoperative use.
- 24 June 2026
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 36 (1) , 249
Open AccessDevelopment of intraoperative fluoroscopic protocols to avoid rotational malalignment during nailing of femoral fractures: a step-by-step guideline using the lesser trochanter profile or true lateral view
Purpose: Rotational malalignment (≥ 15°) occurs in up to 35% of femoral fractures after intramedullary nailing, and standardized fluoroscopy protocols to prevent malrotation are lacking. We developed and evaluated two easy-to-use intraoperative fluoroscopy techniques to reduce malrotation. Methods: A human specimen study was performed to compare two standardized fluoroscopy protocols—the lesser trochanter profile and the true lateral view—with current clinical practice. A mid-shaft femoral fracture was created in a full-body cadaver, and an unlocked intramedullary nail was inserted. Random degrees of rotational malalignment were applied using a goniometer and reference wires at the fracture site. Ten physicians (consultants and residents) first estimated malrotation and then performed 150 rotational corrections: 50 according to (unstandardized) clinical practice, 50 using the lesser trochanter profile, and 50 using the true lateral view. The primary outcome was rotational malalignment, measured using reference wires at the fracture site. Results: Clinicians’ visual estimation deviated 15.5° [IQR 18.5–12.0] from actual malrotation. Corrections using unstandardized methods resulted in 12.5° [IQR 18.2–6.1] of malrotation. In contrast, the lesser trochanter and true lateral protocols reduced malrotation to 3.9° [6.8–2.1] and 3.6° [8.6–1.4], respectively. Both were significantly more accurate than current practice ( p = 0.009 and p = 0.017). Surgeons favoured the lesser trochanter profile for its efficiency, ease-to-use, and minimal need for C-arm repositioning. Conclusion: This study introduces two step-by-step standardized fluoroscopy protocols to prevent rotational malalignment in femoral nailing. Both outperform traditional, unstandardized correction methods, with the lesser trochanter profile offering a more practical and time-efficient option for intraoperative use.
- Open Access
- 1 May 2026
- Published by Elsevier in JSES International
- Vol. 10 (4) , 101724
Articular varus angles of the elbow are not associated with coronoid fracture type
- 1 May 2026
- Published by Elsevier in JSES International
- Vol. 10 (4) , 101724
Open AccessArticular varus angles of the elbow are not associated with coronoid fracture type
- 1 May 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 40 (5) , 237-244
Are 6- to 12-Week Radiographic Union Scores Associated With Healing After Lateral Locked Plating of Distal Femur Fractures?
OBJECTIVES: To determine whether 6–12 weeks modified Radiographic Union Score for Tibial fractures (mRUST) scores after lateral locked plating (LLP) of distal femur fractures were associated with nonunion versus healing. METHODS: Design: Retrospective case–control study. Setting: Two Level 1 Trauma Centers. Patient Selection Criteria: Included were adult patients with distal femur fractures (OTA/AO 33A/C) treated with LLP between 2006 and 2024 and with available postoperative radiographs between 6 and 12 weeks. Nonunion cases were defined as patients undergoing reoperation for nonunion after 12 weeks and were randomly matched 1:2 to controls, defined as those not undergoing reoperation for nonunion and with documented healing or an mRUST score of ≥12 at final follow-up. Outcome Measures and Comparisons: Total mRUST (scale: 4–16) and combined medial and posterior mRUST (scale: 2-8) scores were compared between nonunion cases and controls. Associations of mRUST scores with nonunion versus healing were estimated using logistic regression with adjustment for sampling distribution and time from surgery to mRUST assessment. RESULTS: Thirty distal femur nonunion cases and 60 controls were included (median ages 58 and 63 years; with 70% and 67% women, respectively). The median total mRUST score was 6 (interquartile range 6–7) for nonunion cases and 10 (interquartile range 8–11) for controls ( P < 0.001). Each 1-point increase in mRUST score was associated with a 57% reduction in odds of nonunion (odds ratio: 0.43, 95% confidence interval: 0.24–0.66; area under the curve 0.91). For the combined medial and posterior cortex scores, each 1-point increase was associated with a 70% reduction in odds of nonunion (odds ratio: 0.30, 95% confidence interval: 0.12–0.61; area under the curve 0.84). CONCLUSIONS: mRUST scores between 6 and 12 weeks demonstrated strong association with nonunion versus healing after LLP of distal femur fractures. This was consistent in analysis limited to medial and posterior cortices, although wide confidence intervals suggest imprecision in the effect estimate. Early mRUST assessment may serve as a helpful adjunct to support clinical decision making and patient counseling after LLP of distal femur fractures. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 May 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 40 (5) , 237-244
Are 6- to 12-Week Radiographic Union Scores Associated With Healing After Lateral Locked Plating of Distal Femur Fractures?
OBJECTIVES: To determine whether 6–12 weeks modified Radiographic Union Score for Tibial fractures (mRUST) scores after lateral locked plating (LLP) of distal femur fractures were associated with nonunion versus healing. METHODS: Design: Retrospective case–control study. Setting: Two Level 1 Trauma Centers. Patient Selection Criteria: Included were adult patients with distal femur fractures (OTA/AO 33A/C) treated with LLP between 2006 and 2024 and with available postoperative radiographs between 6 and 12 weeks. Nonunion cases were defined as patients undergoing reoperation for nonunion after 12 weeks and were randomly matched 1:2 to controls, defined as those not undergoing reoperation for nonunion and with documented healing or an mRUST score of ≥12 at final follow-up. Outcome Measures and Comparisons: Total mRUST (scale: 4–16) and combined medial and posterior mRUST (scale: 2-8) scores were compared between nonunion cases and controls. Associations of mRUST scores with nonunion versus healing were estimated using logistic regression with adjustment for sampling distribution and time from surgery to mRUST assessment. RESULTS: Thirty distal femur nonunion cases and 60 controls were included (median ages 58 and 63 years; with 70% and 67% women, respectively). The median total mRUST score was 6 (interquartile range 6–7) for nonunion cases and 10 (interquartile range 8–11) for controls ( P < 0.001). Each 1-point increase in mRUST score was associated with a 57% reduction in odds of nonunion (odds ratio: 0.43, 95% confidence interval: 0.24–0.66; area under the curve 0.91). For the combined medial and posterior cortex scores, each 1-point increase was associated with a 70% reduction in odds of nonunion (odds ratio: 0.30, 95% confidence interval: 0.12–0.61; area under the curve 0.84). CONCLUSIONS: mRUST scores between 6 and 12 weeks demonstrated strong association with nonunion versus healing after LLP of distal femur fractures. This was consistent in analysis limited to medial and posterior cortices, although wide confidence intervals suggest imprecision in the effect estimate. Early mRUST assessment may serve as a helpful adjunct to support clinical decision making and patient counseling after LLP of distal femur fractures. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 30 April 2026
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 52 (1) , 156
Publisher Correction: Experience with patient-specific guides, instead of general surgical experience, improves the accuracy of 3D-guided corrective osteotomies
- 30 April 2026
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 52 (1) , 156
Open AccessPublisher Correction: Experience with patient-specific guides, instead of general surgical experience, improves the accuracy of 3D-guided corrective osteotomies