MPManuel Puga

Manuel Puga

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Manuel Puga has a total of 44 co-authors. Here are the top co-authors by number of shared publications:

  • Laura Rivas

    Research Group in Gastrointestinal Oncology-Ourense, Ourense, Spain; Department of Gastroenterology, Hospital Universitario de Ourense, Ourense, Spain; Centro de Investigación Biomédica en Red Enfermedades Hepáticas y Digestivas, Ourense, Spain

    8 shared publications
  • Eloy Sánchez

    Department of Gastroenterology, Hospital Universitario de Ourense, Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBEREHD), 32005 Ourense, Spain

    7 shared publications
  • Alba Nogueira-Rodríguez

    Department of Computer Science, ESEI - Escuela Superior de Ingeniería Informática, Universidade de Vigo, Ourense 32004, Spain; Next Generation Computer Systems Research Group (SING), Galicia Sur Health Research Institute (IIS Galicia Sur), SERGAS-UVIGO, Spain

    6 shared publications
  • Daniel Glez-Peña

    Department of Computer Science, ESEI - Escuela Superior de Ingeniería Informática, Universidade de Vigo, Ourense 32004, Spain; Next Generation Computer Systems Research Group (SING), Galicia Sur Health Research Institute (IIS Galicia Sur), SERGAS-UVIGO, Spain

    6 shared publications
  • Florentino Fdez-Riverola

    CINBIO, Universidade de Vigo

    6 shared publications
  • Hugo López-Fernández

    Department of Computer Science, ESEI - Escuela Superior de Ingeniería Informática, Universidade de Vigo, Ourense 32004, Spain; Next Generation Computer Systems Research Group (SING), Galicia Sur Health Research Institute (IIS Galicia Sur), SERGAS-UVIGO, Spain

    6 shared publications

Latest Publications

  • Open Access

    PIBAdb: a public cohort of multimodal colonoscopy videos and images including polyps with histological information

    by Alba Nogueira-Rodríguez, Rubén Domínguez-Carbajales, Fernando Campos-Tato, Jesús Herrero, Manuel Puga, Laura Rivas, Eloy Sánchez, Águeda Iglesias, Laura Codesido, Ástrid Irene Díez-Martín, et al.


  • Open Access

    Clinical Evaluation of PolyDeep, A Computer-Aided Detection System: A Multicenter Randomized Tandem Colonoscopy Trial

    by Pedro Davila-Piñón, Astrid Irene Díez Martín, Alba Nogueira-Rodríguez, Ruben Domínguez-Carbajales, Florentino Fdez-Riverola, Sara Zarraquiños, Luisa de Castro, Jesús Herrero, Nereida Fernández, Pablo Vega, et al.

    Background/Objectives: Computer-aided detection (CADe) systems are increasingly used in endoscopy to enhance lesion recognition. PolyDeep is a CADe/x tool previously assessed in an observational study. The aim of our study is to determine if PolyDeep-assisted colonoscopy reduces the adenoma miss rate (AMR) compared with conventional colonoscopy. Methods: We carried out a multicenter randomized controlled trial with a tandem colonoscopy design in participants from a colorectal cancer screening program (positive fecal immunochemical test-FIT or surveillance). Expert endoscopists performed all colonoscopies, and patients were allocated to groups by a computer-generated sequence. The primary endpoint was AMR; secondary endpoints included polyp miss rate (PMR), serrated lesion miss rate (SLMR) and advanced polyp miss rate (APMR). Results: From May to November 2023, we recruited 260 patients and excluded 20, leaving 240 for analysis. Baseline characteristics were balanced between groups (62.1% male; mean age 62.3 ± 6.5 years; 65.8% FIT-positive; mean first withdrawal time 13:38 ± 08:07 min; mean second withdrawal time 07:50 ± 03:38 min; lesion detection rate 76.6%; mean polyps per patient 3.4 ± 3.1). We did not find statistically significant differences between PolyDeep-assisted and conventional colonoscopy groups in AMR (21.3% vs. 18.1%, p = 0.5), PMR (21.8% vs. 20.3%, p = 0.7), SLMR (23.4% vs. 25.6%, p = 0.9) or APMR (7.3% vs. 11.3%, p = 0.5). In the subgroup analysis according to indication, we did not find any statistically significant differences. Conclusions: In the context of a CRC screening program, PolyDeep-assisted colonoscopy did not reduce AMR.


  • Open Access

    Clinical Evaluation of PolyDeep, a Computer Aided Detection system: A Multicenter Randomized Tandem Colonoscopy Trial

    by Pedro Davila-Piñón, Astrid Irene Díez Martín, Alba Nogueira-Rodríguez, Ruben Domínguez-Carbajales, Florentino Fdez-Riverola, Sara Zarraquiños, Luisa de Castro, Jesús Herrero, Nereida Fernández, Pablo Vega, et al.

    Background/Objectives: Computer-aided detection (CADe) systems are increasingly used in endoscopy to enhance lesion recognition. PolyDeep is a CADe/x tool previously assessed in an observational study. The aim of our study is to determine if PolyDeep-assisted colonoscopy reduces the adenoma miss rate (AMR) compared with conventional colonoscopy. Methods: We carried out a multicenter randomized controlled trial with a tandem colonoscopy design in participants from a colorectal cancer screening program (positive fecal immunochemical test-FIT or surveillance). Expert endoscopists performed all colonoscopies, and patients were allocated to groups by a computer-generated sequence. The primary endpoint was AMR; secondary endpoints included polyp miss rate (PMR), serrated lesion miss rate (SLMR) and advanced polyp miss rate (APMR). Results: From May to November 2023, we recruited 260 patients and excluded 20, leaving 240 for analysis. Baseline characteristics were balanced between groups (62.1% male; mean age 62.3 ± 6.5 years; 65.8% FIT-positive; mean first withdrawal time 13:38 ± 08:07 minutes; mean second withdrawal time 07:50 ± 03:38 minutes; lesion detection rate 76.6%; mean polyps per patient 3.4 ± 3.1). We did not find statistically significant differences between PolyDeep-assisted and conventional colonoscopy groups in AMR (21.3% vs 18.1%, p = 0.5), PMR (21.8% vs 20.3%, p = 0.7), SLMR (23.4% vs 25.6%, p = 0.9) or APMR (7.3% vs 11.3%, p = 0.5). In the subgroup analysis according to indication, we did not find any statistically significant differences. Conclusions: In the context of a CRC screening program, PolyDeep-assisted colonoscopy did not reduce AMR.

  • Open Access

    PolyDeep Advance 1: Clinical Validation of a Computer-Aided Detection System for Colorectal Polyp Detection with a Second Observer Design

    by Pedro Davila-Piñón, Teresa Pedrido, Astrid Irene Díez-Martín, Jesús Herrero, Manuel Puga, Laura Rivas, Eloy Sánchez, Sara Zarraquiños, Noel Pin, Pablo Vega, et al.

    Background: PolyDeep is a computer-aided detection and characterization system that has demonstrated a high diagnostic yield for in vitro detection of colorectal polyps. Our objective is to compare the diagnostic performance of expert endoscopists and PolyDeep for colorectal polyp detection. Methods: PolyDeep Advance 1 (NCT05514301) is an unicentric diagnostic test study with a second observer design. Endoscopists performed colonoscopy blinded to PolyDeep’s detection results. The main endpoint was the sensitivity for colorectal polyp (adenoma, serrated or hyperplastic lesion) detection. The secondary endpoints were the diagnostic performance for diminutive lesions (≤5 mm), neoplasia (adenoma, serrated lesion) and adenoma detection. Results: We included 205 patients (55.1% male, 63.0 ± 6.2 years of age) referred to colonoscopy (positive faecal immunochemical occult blood test = 60.5%, surveillance colonoscopy = 39.5%). We excluded eight patients due to incomplete colonoscopy. Endoscopists detected 384 lesions, of which 39 were not detected by PolyDeep. In contrast, PolyDeep predicted 410 possible additional lesions, 26 of these predictions confirmed by endoscopists as lesions, resulting in a potential 6.8% detection increase with respect to the 384 lesions detected by the endoscopists. In total, 410 lesions were detected, 20 were not retrieved, five were colorectal adenocarcinoma, 343 were colorectal polyps (231 adenomas, 39 serrated and 73 hyperplastic polyps), 42 were normal mucosa and 289 were ≤5 mm. We did not find statistically significant differences between endoscopists and PolyDeep for colorectal polyp detection (Sensitivity = 94.2%, 91.5%, p = 0.2; Specificity = 9.5%, 14.3%, p = 0.7), diminutive lesions (Sensitivity = 92.3%, 89.5%, p = 0.4; Specificity = 9.8%, 14.6%, p = 0.7), neoplasia (Sensitivity = 95.2%, 92.9%, p = 0.3; Specificity = 9.6%, 13.9%, p = 0.4) and adenoma detection (Sensitivity = 94.4%, 92.6%, p = 0.5; Specificity = 7.2%, 11.8%, p = 0.2). Conclusions: Expert endoscopists and PolyDeep have similar diagnostic performance for colorectal polyp detection.


  • Open Access

    PolyDeep Advance 1: Clinical Validation of a Computer-Aided Detection System for Colorectal Polyp Detection with a Second Observer Design

    by Pedro Davila-Piñón, Teresa Pedrido, Astrid Irene Díez-Martín, Jesús Herrero, Manuel Puga, Laura Rivas, Eloy Sánchez, Sara Zarraquiños, Noel Pin, Pablo Vega, et al.

    Background: PolyDeep is a computer-aided detection and characterization system that has demonstrated a high diagnostic yield for in vitro detection of colorectal polyps. Our objective is to compare the diagnostic performance of expert endoscopists and PolyDeep for colorectal polyp detection. Methods: PolyDeep Advance 1 (NCT05514301) is an unicentric diagnostic test study with a second observer design. Endoscopists performed the colonoscopy blinded to PolyDeep. The main endpoint was the sensitivity for colorectal polyp (adenoma, serrated or hyperplastic lesion) detection. The secondary endpoints were the diagnostic performance for diminutive lesions (≤5 mm), neoplasia (adenoma, serrated lesion) and adenoma detection. Results: We included 205 patients (55.1% male, 63.0 ± 6.2 years of age) referred to colonoscopy (positive faecal immunochemical occult blood test = 60.5%, surveillance colonoscopy = 39.5%). We excluded 8 patients due to incomplete colonoscopy. Endoscopists detected 384 lesions, of which 39 were not detected by PolyDeep. In contrast, PolyDeep predicted 410 possible additional lesions, 26 of these predictions confirmed by endoscopists as lesions, resulting in a potential 6.8% detection increase with respect to the 384 lesions detected by the endoscopists. In total, 410 lesions were detected, 20 were not retrieved, 5 were colorectal adenocarcinoma, 343 were colorectal polyps (231 adenomas, 39 serrated and 73 hyperplastic polyps), 42 were normal mucosa and 289 were ≤5mm. We did not find statistically significant differences between endoscopists and PolyDeep for colorectal polyp detection (Sensitivity = 94.2%, 91.5%, p = 0.2; Specificity = 9.5%, 14.3%, p = 0.7), diminutive lesions (Sensitivity = 92.3%,89.5%, p = 0.4; Specificity = 9.8%, 14.6%, p = 0.7), neoplasia (Sensitivity = 95.2%, 92.9%, p = 0.3; Specificity = 9.6%, 13.9%, p = 0.4) and adenoma detection (Sensitivity = 94.4%, 92.6%, p = 0.5; Specificity = 7.2%, 11.8%, p = 0.2). Conclusion: Expert endoscopists and PolyDeep have similar diagnostic performance for colorectal polyp detection.

  • Open Access

    El caso estructural en América Latina

    by Mariela Gladys Puga

    Este artigo propõe-se a refletir sobre a definição do caso estrutural a partir de uma perspectiva teórico-jurídica situada no sistema jurídico argentino, embora conscientemente acolhida pela projeção da jurisdição estrutural do direito latino-americano. Os dois elementos da definição proposta, tais como a normatividade expansiva da decisão e a configuração policêntrica do caso, são analisados separadamente. Através de decisões paradigmáticas da região, explica-se a relação entre eles e o modo como funcionam como determinantes das regras do processo coletivo e dos remédios complexos. Finalmente, contrasta-se a definição apresentada com a de Owen Fiss para os litígios de reforma pública, e oferece-se razões para preferir a perspectiva aqui proposta no contexto latino-americano.


  • Evaluation of the effectiveness and safety of single-operator cholangiopancreatoscopy with the SpyGlass™ system

    by Coral Tejido, Manuel Puga, Cristina Regueiro, María Francisco, Laura Rivas, Eloy Sánchez


  • Open Access

    Real-time polyp detection model using convolutional neural networks

    by Alba Nogueira-Rodríguez, Domínguez- Carbajales, Rubén, Fernando Campos-Tato, Jesús Herrero, Manuel Puga, David Remedios, Laura Rivas, Eloy Sánchez, Águeda Iglesias, et al.

    Colorectal cancer is a major health problem, where advances towards computer-aided diagnosis (CAD) systems to assist the endoscopist can be a promising path to improvement. Here, a deep learning model for real-time polyp detection based on a pre-trained YOLOv3 (You Only Look Once) architecture and complemented with a post-processing step based on an object-tracking algorithm to reduce false positives is reported. The base YOLOv3 network was fine-tuned using a dataset composed of 28,576 images labelled with locations of 941 polyps that will be made public soon. In a frame-based evaluation using isolated images containing polyps, a general F1 score of 0.88 was achieved (recall = 0.87, precision = 0.89), with lower predictive performance in flat polyps, but higher for sessile, and pedunculated morphologies, as well as with the usage of narrow band imaging, whereas polyp size < 5 mm does not seem to have significant impact. In a polyp-based evaluation using polyp and normal mucosa videos, with a positive criterion defined as the presence of at least one 50-frames-length (window size) segment with a ratio of 75% of frames with predicted bounding boxes (frames positivity), 72.61% of sensitivity (95% CI 68.99–75.95) and 83.04% of specificity (95% CI 76.70–87.92) were achieved (Youden = 0.55, diagnostic odds ratio (DOR) = 12.98). When the positive criterion is less stringent (window size = 25, frames positivity = 50%), sensitivity reaches around 90% (sensitivity = 89.91%, 95% CI 87.20–91.94; specificity = 54.97%, 95% CI 47.49–62.24; Youden = 0.45; DOR = 10.76). The object-tracking algorithm has demonstrated a significant improvement in specificity whereas maintaining sensitivity, as well as a marginal impact on computational performance. These results suggest that the model could be effectively integrated into a CAD system.


  • Open Access

    A novel rescue maneuver for a distal dislodged lumen-apposing metal stent (LAMS): LAMS-in-LAMS technique

    by Maria Curieses Luengo, Claudia F. Consiglieri, Manuel Puga, Joan B. Gornals

    The appearance of the lumen-apposing metal stent (LAMS) has meant an authentic revolution. To date, the results are promising but it is necessary to note the technical incidents and LAMS-related complications. an EUS-transmural guided drainage using a HotAXIOS was planned for a 36-year-old man with oral intolerance due to a voluminous walled-off necrosis. The distal flange was left in the collection, but a total distal malposition occurred during the proximal flange delivery, despite correct apposition with visualization of the black mark. A rescue technique was performed inserting a second LAMS over-the-guidewire salvaging the initial failed transmural drainage. This case is a reminder that in similar scenarios, extreme tension of the echoendoscope can cause a malfunction of the AXIOS stent delivery system, and lead to a total distal malposition. This "LAMS-in-LAMS" technique is feasible, effective, and a very helpful rescue technique in cases of dislodged LAMS.