SZSamuel Zibman

Samuel Zibman

*This is an algorithmically generated author record based on publicly available information.

Samuel Zibman has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Revisiting the Rotational Field TMS Method for Neurostimulation

    by Yiftach Roth, Samuel Zibman, Gaby S. Pell, Abraham Zangen, Aron Tendler

    Transcranial magnetic stimulation (TMS) is a non-invasive technique that has shown high efficacy in the treatment of major depressive disorder (MDD) and is increasingly utilized for various neuropsychiatric disorders. However, conventional TMS is limited to activating only a small fraction of neurons that have components parallel to the induced electric field. This likely contributes to the significant variability observed in clinical outcomes. A novel method termed rotational field TMS (rfTMS or TMS 360°) enables the activation of a greater number of neurons by reducing the sensitivity to orientation. Recruitment of a larger number of neurons offers the potential to enhance efficacy and reduce variability in the treatment of clinical indications for which neuronal recruitment and organization may play a significant role, such as MDD and stroke. The potential of the method remains to be validated in clinical trials. Here, we revisit and describe in detail the rfTMS method, its principles, mode of operation, effects on the brain, and potential benefits for clinical TMS.


  • Open Access

    Auditory Fine-Tuned Suppressor of TMS-Clicks (TMS-Click AFTS): A Novel, Perceptually Driven/Tuned Approach for the Reduction in AEP Artifacts in TMS-EEG Studies

    by Konstantinos Pastiadis, Ioannis Vlachos, Evangelia Chatzikyriakou, Yiftach Roth, Samuel Zibman, Abraham Zangen, Dimitris Kugiumtzis, Vasilios K. Kimiskidis

    TMS contaminates concurrent EEG recordings with Auditory Evoked Potentials (AEPs), which are caused by the perceived impulsive acoustic noise of the TMS coils. We hereby introduce a novel and perceptually motivated/tuned method for the suppression of auditory evoked EEG artifacts of rTMS under the name of “Auditory Fine-Tuned Suppressor of TMS-Clicks” (TMS-click AFTS). The proposed method is based on the deployment of a psychophysically-matched wide-band noise (WBN) masking stimulus, whose parametric synthesis and presentation are based upon adaptive psychophysical optimization. The masking stimulus is constructed individually for each patient/subject, thus facilitating aspects of precision medicine. A specially designed automation software is used for the realization of an adaptive procedure for optimal parameterization of masking noise level, optimizing both the subject’s comfort and the degree of AEP reduction. The proposed adaptive procedure also takes into account the combined effect of TMS intensity level and can as well account for any possibly available subject’s hearing acuity data. To assess the efficacy of the proposed method in reducing the acoustic effects of TMS, we performed TMS-EEG recordings with a 60 channel TMS-compatible EEG system in a cohort of healthy subjects (n = 10) and patients with epilepsy (n = 10) under four conditions (i.e., resting EEG with and without acoustic mask and sham TMS-EEG with and without acoustic mask at various stimulus intensity levels). The proposed approach shows promising results in terms of efficiency of AEP suppression and subject’s comfort and warrants further investigation in research and clinical settings.


  • Open Access

    Efficacy of Deep TMS with the H1 Coil for Anxious Depression

    by Gaby S. Pell, Tal Harmelech, Sam Zibman, Yiftach Roth, Aron Tendler, Abraham Zangen

    (1) Background: While the therapeutic efficacy of Transcranial Magnetic Stimulation (TMS) for major depressive disorder (MDD) is well established, less is known about the technique’s efficacy for treating comorbid anxiety. (2) Methods: Data were retrospectively analyzed from randomized controlled trials (RCTs) that used Deep TMS with the H1 Coil for MDD treatment. The primary endpoint was the difference relative to sham treatment following 4 weeks of stimulation. The effect size was compared to literature values for superficial TMS and medication treatments. (3) Results: In the pivotal RCT, active Deep TMS compared with sham treatment showed significantly larger improvements in anxiety score (effect size = 0.34, p = 0.03 (FDR)) which were sustained until 16 weeks (effect size = 0.35, p = 0.04). The pooled effect size between all the RCTs was 0.55, which compares favorably to alternative treatments. A direct comparison to Figure-8 Coil treatment indicated that treatment with the H1 Coil was significantly more effective (p = 0.042). In contrast to previously reported studies using superficial TMS and medication for which anxiety has been shown to be a negative predictor of effectiveness, higher baseline anxiety was found to be predictive of successful outcome for the H1-Coil treatment. (4) Conclusions: Deep TMS is effective in treating comorbid anxiety in MDD and, unlike alternative treatments, the outcome does not appear to be adversely affected by high baseline anxiety levels.