Nasiq Hasan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nasiq Hasan has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
- Jay Chhablani
UPMC Eye Center, University of Pittsburgh, Pittsburgh, Pennsylvania
9 shared publications - Kiran Kumar Vupparaboina
Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, USA
4 shared publications - Adarsh Gadari
Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA 15260, USA
3 shared publications - Charles Clifton Wykoff
Retina Consultants of Texas, Houston, Texas
3 shared publications Dheepak Sundar
Dr. Rajendra Prasad Centre for Ophthalmic Sciences, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, New Delhi, India
3 shared publications- Elham Sadeghi
School of Medicine, University of Pittsburgh, Pittsburgh, USA
3 shared publications
Latest Publications
- 1 December 2026
- Published by Wolters Kluwer Health in Retina
- Vol. 46 (12) , 2115-2124
CLINICAL VARIATIONS AND OUTCOMES OF CENTRAL SEROUS CHORIORETINOPATHY IN BLACK AND WHITE PATIENTS
Purpose: To compare baseline characteristics and outcomes of central serous chorioretinopathy (CSCR) between people who identify as Black and those who identify as White. Methods: This retrospective, multicenter study from the MICRoN study group, included Black and White patients with CSCR. Demographic information and multimodal imaging parameters were analyzed and compared in the two groups. Regression models were used to identify factors affecting visual outcomes, anatomical changes, and disease recurrence/persistence. Results: We included a total of 450 patients (312 men and 138 women), of whom 100 were Black patients, and 350 were White patients. Black patients were significantly older (51.9 vs. 48.8 years, P = 0.03) but had shorter symptom duration at presentation (1 vs. 3 months, P = 0.003). Black patients demonstrated worse baseline visual acuity (0.3 ± 0.3 vs. 0.2 ± 0.2 logMAR, P < 0.001), greater retinal detachment height (157.9 vs. 107.5 µ m, P = 0.002), and more frequent peripapillary retinal pigment epithelium changes (27% vs. 9.4%, P < 0.001). During a median follow-up of 24 months (IQR 10–60 months), White patients experienced significantly higher rates of disease recurrence (35.7% vs. 19%, P = 0.002), persistent subretinal fluid (13.1% vs. 4%, P = 0.01), and macular neovascularization development (21.1% vs. 4%, P < 0.001). Multivariable regression confirmed that Black patients were associated with reduced recurrence risk (Odds Ratio 0.52, P = 0.03). Conclusion: Despite presenting with more severe morphologic changes and worse initial vision, Black patients demonstrate substantially lower rates of recurrences and sequelae, suggesting biological differences in disease pathophysiology.
- 1 December 2026
- Published by Wolters Kluwer Health in Retina
- Vol. 46 (12) , 2115-2124
CLINICAL VARIATIONS AND OUTCOMES OF CENTRAL SEROUS CHORIORETINOPATHY IN BLACK AND WHITE PATIENTS
Purpose: To compare baseline characteristics and outcomes of central serous chorioretinopathy (CSCR) between people who identify as Black and those who identify as White. Methods: This retrospective, multicenter study from the MICRoN study group, included Black and White patients with CSCR. Demographic information and multimodal imaging parameters were analyzed and compared in the two groups. Regression models were used to identify factors affecting visual outcomes, anatomical changes, and disease recurrence/persistence. Results: We included a total of 450 patients (312 men and 138 women), of whom 100 were Black patients, and 350 were White patients. Black patients were significantly older (51.9 vs. 48.8 years, P = 0.03) but had shorter symptom duration at presentation (1 vs. 3 months, P = 0.003). Black patients demonstrated worse baseline visual acuity (0.3 ± 0.3 vs. 0.2 ± 0.2 logMAR, P < 0.001), greater retinal detachment height (157.9 vs. 107.5 µ m, P = 0.002), and more frequent peripapillary retinal pigment epithelium changes (27% vs. 9.4%, P < 0.001). During a median follow-up of 24 months (IQR 10–60 months), White patients experienced significantly higher rates of disease recurrence (35.7% vs. 19%, P = 0.002), persistent subretinal fluid (13.1% vs. 4%, P = 0.01), and macular neovascularization development (21.1% vs. 4%, P < 0.001). Multivariable regression confirmed that Black patients were associated with reduced recurrence risk (Odds Ratio 0.52, P = 0.03). Conclusion: Despite presenting with more severe morphologic changes and worse initial vision, Black patients demonstrate substantially lower rates of recurrences and sequelae, suggesting biological differences in disease pathophysiology.
- 1 December 2026
- Published by Wolters Kluwer Health in Retina
- Vol. 46 (12) , 2125-2132
HISPANIC VERSUS NON-HISPANIC PATIENTS WITH CENTRAL SEROUS CHORIORETINOPATHY
Purpose: To compare baseline characteristics and clinical course between Hispanic and non-Hispanic patients with central serous chorioretinopathy (CSC). Methods: This retrospective, multicenter study from the Macula Society CSC Research Network included Hispanic and non-Hispanic patients with CSC. Demographic characteristics and multimodal imaging variables were compared between groups. Regression analyses identified factors associated with visual outcomes, structural changes, and disease recurrence/persistence. Results: A total of 480 patients were included (130 Hispanic and 350 non-Hispanic). Non-Hispanic patients were significantly older at presentation (48.8 ± 11.1 vs. 45.3 ± 11.6 years, P = 0.003) and had better baseline best-recorded visual acuity (20/25 vs. 20/40, P < 0.001). A significantly higher percentage of Hispanic patients presented with complex CSC (73.8% vs. 28.3%, P < 0.001), multifocal retinal pigment epithelium (RPE) alterations (58.5% vs. 9.7%, P < 0.001), and greater neurosensory detachment height (193 [IQR: 100–301] vs. 113 [IQR: 66–193] microns, P < 0.001). Conversely, non-Hispanic patients demonstrated larger areas of RPE alteration (1.5 [IQR: 1–3] vs. 1 [IQR: 0.25–1.5] disk areas, P < 0.001). At last follow-up, both groups showed significant improvement in best-recorded visual acuity (Hispanics: 20/40–20/25, P < 0.001; non-Hispanics: 20/25–20/20, P < 0.001), with no significant difference in rates of recurrence (40% vs. 35.7%, P = 0.08) or persistence (11.5% vs. 13.1%, P = 0.08). Conclusion: In our cohort, Hispanic patients more commonly presented with complex CSC, multifocal RPE alterations, and greater neurosensory detachment height, while non-Hispanic patients were older with better baseline vision and larger areas of RPE alteration. Despite these differences, visual outcomes improved meaningfully in both groups, with comparable rates of recurrence and persistence.
- 1 December 2026
- Published by Wolters Kluwer Health in Retina
- Vol. 46 (12) , 2125-2132
HISPANIC VERSUS NON-HISPANIC PATIENTS WITH CENTRAL SEROUS CHORIORETINOPATHY
Purpose: To compare baseline characteristics and clinical course between Hispanic and non-Hispanic patients with central serous chorioretinopathy (CSC). Methods: This retrospective, multicenter study from the Macula Society CSC Research Network included Hispanic and non-Hispanic patients with CSC. Demographic characteristics and multimodal imaging variables were compared between groups. Regression analyses identified factors associated with visual outcomes, structural changes, and disease recurrence/persistence. Results: A total of 480 patients were included (130 Hispanic and 350 non-Hispanic). Non-Hispanic patients were significantly older at presentation (48.8 ± 11.1 vs. 45.3 ± 11.6 years, P = 0.003) and had better baseline best-recorded visual acuity (20/25 vs. 20/40, P < 0.001). A significantly higher percentage of Hispanic patients presented with complex CSC (73.8% vs. 28.3%, P < 0.001), multifocal retinal pigment epithelium (RPE) alterations (58.5% vs. 9.7%, P < 0.001), and greater neurosensory detachment height (193 [IQR: 100–301] vs. 113 [IQR: 66–193] microns, P < 0.001). Conversely, non-Hispanic patients demonstrated larger areas of RPE alteration (1.5 [IQR: 1–3] vs. 1 [IQR: 0.25–1.5] disk areas, P < 0.001). At last follow-up, both groups showed significant improvement in best-recorded visual acuity (Hispanics: 20/40–20/25, P < 0.001; non-Hispanics: 20/25–20/20, P < 0.001), with no significant difference in rates of recurrence (40% vs. 35.7%, P = 0.08) or persistence (11.5% vs. 13.1%, P = 0.08). Conclusion: In our cohort, Hispanic patients more commonly presented with complex CSC, multifocal RPE alterations, and greater neurosensory detachment height, while non-Hispanic patients were older with better baseline vision and larger areas of RPE alteration. Despite these differences, visual outcomes improved meaningfully in both groups, with comparable rates of recurrence and persistence.
- Open Access
- 26 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (21) , 3497
Deep Learning-Based Automated Detection, Segmentation, and Quantification of Retinal Fluid on Optical Coherence Tomography: A Validation Study
Objectives: To validate a deep learning-based algorithm for automated detection, segmentation, and quantitative assessment of retinal fluid on optical coherence tomography (OCT) across multiple retinal diseases. Methods: In this retrospective validation study, spectral-domain OCT volume scans from eyes with neovascular age-related macular degeneration (nAMD), diabetic macular edema (DME), and macular telangiectasia type 2 (MacTel) were analyzed. Automated segmentation was performed using the fluid analyzer on Skopix by NetraMind Innovations, a deep learning-based framework trained to identify intraretinal fluid (IRF), subretinal fluid (SRF), pigment epithelial detachment (PED), and subretinal hyperreflective material (SHRM). Automated segmentations were reviewed and manually corrected by two masked experienced retina graders, with discrepancies adjudicated by a senior retina specialist. Scan-level detection performance was evaluated using accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), area under the receiver operating characteristic curve (AUC), and Gwet’s first-order agreement coefficient (AC1). Spatial segmentation agreement across all B-scans was assessed using the Dice coefficient. Quantitative agreement between automated and manually corrected fluid volumes was evaluated using correlation and Bland–Altman analyses. Inter-grader reliability was assessed using the intraclass correlation coefficient (ICC). Results: A total of 98 OCT volumes comprising 31 nAMD, 25 DME, and 42 MacTel eyes were included. In nAMD, IRF detection demonstrated a sensitivity of 81.8%, specificity of 83.0%, and AUC of 0.876, while SRF demonstrated a sensitivity of 81.4%, specificity of 96.7%, and AUC of 0.901. In DME, sensitivity, specificity, and AUC were 99.6%, 97.3%, and 0.989 for IRF and 98.4%, 96.4%, and 0.978 for SRF, respectively. In MacTel, IRF demonstrated a sensitivity of 87.3%, specificity of 95.1%, and AUC of 0.927, while SRF demonstrated a sensitivity of 86.8%, specificity of 98.4%, and AUC of 0.929. Segmentation agreement between automated and manually corrected annotations was high across disease groups, with Dice coefficients of 0.829 and 0.922 for IRF and SRF in nAMD, 0.858 and 0.941 in DME, and 0.908 and 0.97 in MacTel, respectively. Automated fluid volumes demonstrated strong correlations with manually corrected measurements, with minimal systematic bias on Bland–Altman analysis. Conclusions: The automated segmentation algorithm demonstrated strong validation performance for the detection and quantitative assessment of retinal fluid across nAMD, DME, and MacTel. High segmentation agreement, particularly for IRF and SRF, and strong volumetric agreement with expert-corrected measurements support the potential use of automated OCT fluid quantification in clinical practice and research.
- 26 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (21) , 3497
Open AccessDeep Learning-Based Automated Detection, Segmentation, and Quantification of Retinal Fluid on Optical Coherence Tomography: A Validation Study
Objectives: To validate a deep learning-based algorithm for automated detection, segmentation, and quantitative assessment of retinal fluid on optical coherence tomography (OCT) across multiple retinal diseases. Methods: In this retrospective validation study, spectral-domain OCT volume scans from eyes with neovascular age-related macular degeneration (nAMD), diabetic macular edema (DME), and macular telangiectasia type 2 (MacTel) were analyzed. Automated segmentation was performed using the fluid analyzer on Skopix by NetraMind Innovations, a deep learning-based framework trained to identify intraretinal fluid (IRF), subretinal fluid (SRF), pigment epithelial detachment (PED), and subretinal hyperreflective material (SHRM). Automated segmentations were reviewed and manually corrected by two masked experienced retina graders, with discrepancies adjudicated by a senior retina specialist. Scan-level detection performance was evaluated using accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), area under the receiver operating characteristic curve (AUC), and Gwet’s first-order agreement coefficient (AC1). Spatial segmentation agreement across all B-scans was assessed using the Dice coefficient. Quantitative agreement between automated and manually corrected fluid volumes was evaluated using correlation and Bland–Altman analyses. Inter-grader reliability was assessed using the intraclass correlation coefficient (ICC). Results: A total of 98 OCT volumes comprising 31 nAMD, 25 DME, and 42 MacTel eyes were included. In nAMD, IRF detection demonstrated a sensitivity of 81.8%, specificity of 83.0%, and AUC of 0.876, while SRF demonstrated a sensitivity of 81.4%, specificity of 96.7%, and AUC of 0.901. In DME, sensitivity, specificity, and AUC were 99.6%, 97.3%, and 0.989 for IRF and 98.4%, 96.4%, and 0.978 for SRF, respectively. In MacTel, IRF demonstrated a sensitivity of 87.3%, specificity of 95.1%, and AUC of 0.927, while SRF demonstrated a sensitivity of 86.8%, specificity of 98.4%, and AUC of 0.929. Segmentation agreement between automated and manually corrected annotations was high across disease groups, with Dice coefficients of 0.829 and 0.922 for IRF and SRF in nAMD, 0.858 and 0.941 in DME, and 0.908 and 0.97 in MacTel, respectively. Automated fluid volumes demonstrated strong correlations with manually corrected measurements, with minimal systematic bias on Bland–Altman analysis. Conclusions: The automated segmentation algorithm demonstrated strong validation performance for the detection and quantitative assessment of retinal fluid across nAMD, DME, and MacTel. High segmentation agreement, particularly for IRF and SRF, and strong volumetric agreement with expert-corrected measurements support the potential use of automated OCT fluid quantification in clinical practice and research.
- Open Access
- 16 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1872
Deep Learning-Based Automated Segmentation and Quantification of the Ellipsoid Zone and the RPE–Bruch’s Membrane Complex in Healthy Subjects and in Geographic Atrophy
Purpose: This study aimed to validate a deep learning algorithm for automated segmentation and quantitative assessment of the ellipsoid zone (EZ) and the retinal pigment epithelium (RPE)–Bruch’s membrane (BM) complex in healthy eyes and geographic atrophy (GA) eyes. Methods: In this retrospective study, spectral-domain optical coherence tomography (SD-OCT) volume scans from 30 healthy eyes and 30 eyes with GA were analyzed. An NMI-Outer Retina Analyzer was used to segment the inner EZ, inner RPE, and outer BM. Average thicknesses of the EZ-RPE, EZ-BM, and RPE-BM were calculated from volumes and across nine ETDRS sectors. Manual segmentations were corrected by two masked expert graders and compared using intraclass correlation coefficients (ICCs). Dice coefficients (DCs), Pearson correlation coefficients, and absolute thickness differences were used to assess agreement between automated and manual segmentation. Heat maps were generated to visualize thickness. Results: Thirty healthy eyes and thirty GA eyes were included in the analysis. Mean EZ-RPE, EZ-BM, and RPE-BM thicknesses were 47.55 ± 6.75 µm, 69.49 ± 6.92 µm, and 21.94 ± 3.46 µm, respectively, in the healthy eyes and 15.65 ± 11.09 µm, 39.18 ± 23.28 µm, and 23.52 ± 16.21 µm, respectively, in GA eyes. The model demonstrated high segmentation accuracy, with a mean DC of 0.998 in healthy eyes and 0.995–0.998 in GA eyes. In healthy eyes, differences between automated and manual measurements were minimal (1.42 ± 3.39 μm (2.98%) for EZ-RPE, 1.31 ± 3.18 μm (1.88%) for EZ-BM, and 0.67 ± 1.71 μm (3.05%) for RPE-BM), all within 1.88–3.05% of the gold standard (manual corrections). In contrast, GA eyes showed greater variability (mean differences of 3.61 ± 8.62 μm (23.06%) for EZ-RPE, 4.28 ± 11.34 μm (10.92%) for EZ-BM, and 4.4 ± 10.45 μm (18.71%) for RPE-BM). Heat maps revealed increased variability in the junctional zone surrounding the atrophy. Automated and manual measurements showed strong correlations across all sectors in GA eyes (r = 0.97 for EZ-BM, 0.96 for EZ-RPE, and 0.89 for RPE-BM). Conclusions: The NMI-ORA enables accurate, automated segmentation and quantification of outer retinal layers, with performance comparable to that of expert graders.
- 16 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1872
Open AccessDeep Learning-Based Automated Segmentation and Quantification of the Ellipsoid Zone and the RPE–Bruch’s Membrane Complex in Healthy Subjects and in Geographic Atrophy
Purpose: This study aimed to validate a deep learning algorithm for automated segmentation and quantitative assessment of the ellipsoid zone (EZ) and the retinal pigment epithelium (RPE)–Bruch’s membrane (BM) complex in healthy eyes and geographic atrophy (GA) eyes. Methods: In this retrospective study, spectral-domain optical coherence tomography (SD-OCT) volume scans from 30 healthy eyes and 30 eyes with GA were analyzed. An NMI-Outer Retina Analyzer was used to segment the inner EZ, inner RPE, and outer BM. Average thicknesses of the EZ-RPE, EZ-BM, and RPE-BM were calculated from volumes and across nine ETDRS sectors. Manual segmentations were corrected by two masked expert graders and compared using intraclass correlation coefficients (ICCs). Dice coefficients (DCs), Pearson correlation coefficients, and absolute thickness differences were used to assess agreement between automated and manual segmentation. Heat maps were generated to visualize thickness. Results: Thirty healthy eyes and thirty GA eyes were included in the analysis. Mean EZ-RPE, EZ-BM, and RPE-BM thicknesses were 47.55 ± 6.75 µm, 69.49 ± 6.92 µm, and 21.94 ± 3.46 µm, respectively, in the healthy eyes and 15.65 ± 11.09 µm, 39.18 ± 23.28 µm, and 23.52 ± 16.21 µm, respectively, in GA eyes. The model demonstrated high segmentation accuracy, with a mean DC of 0.998 in healthy eyes and 0.995–0.998 in GA eyes. In healthy eyes, differences between automated and manual measurements were minimal (1.42 ± 3.39 μm (2.98%) for EZ-RPE, 1.31 ± 3.18 μm (1.88%) for EZ-BM, and 0.67 ± 1.71 μm (3.05%) for RPE-BM), all within 1.88–3.05% of the gold standard (manual corrections). In contrast, GA eyes showed greater variability (mean differences of 3.61 ± 8.62 μm (23.06%) for EZ-RPE, 4.28 ± 11.34 μm (10.92%) for EZ-BM, and 4.4 ± 10.45 μm (18.71%) for RPE-BM). Heat maps revealed increased variability in the junctional zone surrounding the atrophy. Automated and manual measurements showed strong correlations across all sectors in GA eyes (r = 0.97 for EZ-BM, 0.96 for EZ-RPE, and 0.89 for RPE-BM). Conclusions: The NMI-ORA enables accurate, automated segmentation and quantification of outer retinal layers, with performance comparable to that of expert graders.
- Open Access
- 21 April 2026
- Published by MDPI AG in Preprints.org
Deep Learning–Based Automated Segmentation and Quantification of Ellipsoid Zone and RPE–Bruch’s Membrane Complex in Healthy Subjects and Geographic Atrophy
Purpose: To validate a deep learning algorithm for automated segmentation and quantitative assessment of the ellipsoid zone (EZ) and RPE–Bruch’s membrane (BM) complex in healthy and geographic atrophy (GA) eyes. Methods: In this retrospective study, SD-OCT volume scans from 30 healthy and 30 eyes with GA were analysed. NMI-Outer Retina Analyzer was used to segment the inner EZ, inner RPE, and outer BM. Average thicknesses of EZ-RPE, EZ-BM, and RPE-BM were calculated from volumes and across nine ETDRS sectors. Manual segmentations were corrected by two masked expert graders and were compared using ICC. Dice coefficients (DC), Pearson correlation, and absolute thickness differences were used to assess agreement between automated and manual segmentation. Heat maps were generated to visualize thicknesses. Results: Thirty healthy eyes and thirty GA eyes were included in the analysis. Mean EZ–RPE, EZ–BM, and RPE–BM thicknesses were 47.55 ± 6.75 µm, 69.49 ± 6.92 µm, and 21.94 ± 3.46 µm, in the healthy eyes and 15.65 ± 11.09 µm, 39.18 ± 23.28 µm, and 23.52 ± 16.21 µm in GA eyes respectively. The model demonstrated high segmentation accuracy, with mean DC of 0.998 in healthy eyes and 0.995–0.998 in GA eyes. In healthy eyes, differences between automated and manual measurements were minimal (1.42 ± 3.39 μm (2.98%) for EZ–RPE, 1.31 ± 3.18 μm (1.88%) for EZ–BM, and 0.67 ± 1.71 μm (3.05%) for RPE–BM) which is within 1.88-3.05% from the gold standard (manual corrections), whereas GA eyes showed greater variability (mean differences of 3.61 ± 8.62 μm (23.06%) for EZ–RPE, 4.28 ± 11.34 μm (10.92%) for EZ–BM, and 4.4 ± 10.45 μm (18.71%) for RPE–BM). Heat maps revealed increased variability at the junctional zone surrounding atrophy. Automated and manual measurements showed strong correlations across all sectors in GA eyes (r = 0.97 for EZ–BM, 0.96 for EZ–RPE, and 0.89 for RPE–BM). Conclusions: The NMI-ORA enables accurate, automated segmentation and quantification of outer retinal layers, with performance comparable to expert graders.
- 21 April 2026
- Published by MDPI AG in Preprints.org
Open AccessDeep Learning–Based Automated Segmentation and Quantification of Ellipsoid Zone and RPE–Bruch’s Membrane Complex in Healthy Subjects and Geographic Atrophy
Purpose: To validate a deep learning algorithm for automated segmentation and quantitative assessment of the ellipsoid zone (EZ) and RPE–Bruch’s membrane (BM) complex in healthy and geographic atrophy (GA) eyes. Methods: In this retrospective study, SD-OCT volume scans from 30 healthy and 30 eyes with GA were analysed. NMI-Outer Retina Analyzer was used to segment the inner EZ, inner RPE, and outer BM. Average thicknesses of EZ-RPE, EZ-BM, and RPE-BM were calculated from volumes and across nine ETDRS sectors. Manual segmentations were corrected by two masked expert graders and were compared using ICC. Dice coefficients (DC), Pearson correlation, and absolute thickness differences were used to assess agreement between automated and manual segmentation. Heat maps were generated to visualize thicknesses. Results: Thirty healthy eyes and thirty GA eyes were included in the analysis. Mean EZ–RPE, EZ–BM, and RPE–BM thicknesses were 47.55 ± 6.75 µm, 69.49 ± 6.92 µm, and 21.94 ± 3.46 µm, in the healthy eyes and 15.65 ± 11.09 µm, 39.18 ± 23.28 µm, and 23.52 ± 16.21 µm in GA eyes respectively. The model demonstrated high segmentation accuracy, with mean DC of 0.998 in healthy eyes and 0.995–0.998 in GA eyes. In healthy eyes, differences between automated and manual measurements were minimal (1.42 ± 3.39 μm (2.98%) for EZ–RPE, 1.31 ± 3.18 μm (1.88%) for EZ–BM, and 0.67 ± 1.71 μm (3.05%) for RPE–BM) which is within 1.88-3.05% from the gold standard (manual corrections), whereas GA eyes showed greater variability (mean differences of 3.61 ± 8.62 μm (23.06%) for EZ–RPE, 4.28 ± 11.34 μm (10.92%) for EZ–BM, and 4.4 ± 10.45 μm (18.71%) for RPE–BM). Heat maps revealed increased variability at the junctional zone surrounding atrophy. Automated and manual measurements showed strong correlations across all sectors in GA eyes (r = 0.97 for EZ–BM, 0.96 for EZ–RPE, and 0.89 for RPE–BM). Conclusions: The NMI-ORA enables accurate, automated segmentation and quantification of outer retinal layers, with performance comparable to expert graders.
- 11 October 2025
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 264 (1) , 73-80
Predictors of persistent central serous chorioretinopathy: a multicenter retrospective study – MICRoN report number four
Purpose While central serous chorioretinopathy (CSCR) frequently resolves after the first episode, in 30–50% of cases, subretinal fluid (SRF) persists and can substantially impair vision. To identify persistence predictors, this study compared demographic, clinical, and imaging data between patients with resolution and SRF persistence. Methods Retrospective data were collected at baseline and follow-up from 308 eyes of 295 patients with CSCR in collaboration with the Macula Society CSCR Study Group. Patients were divided into a resolved (RG) and a persistent CSCR group (PG). Patients with known recurrence after resolution were excluded. Optical coherence tomography (OCT) biomarkers including central macular thickness (CMT), subfoveal choroidal thickness (SFCT), neurosensory detachment height (NSD), Haller layer thickness, inner choroidal thickness (ICT), and choroidal vascularity index (CVI) were analysed. Results PG had 148 eyes and RG had 160 eyes. Mean age in PG vs RG was 47.62 ± 11.63 vs. 44.89 ± 10.12 years (p = 0.029). Mean presenting symptom duration was significantly greater in PG than RG (8.67 ± 23.33 vs. 4.33 ± 31.18 months) (p = 0.005). There was a higher frequency of complex cases (21.6%) in PG (p < 0.001). Baseline mean CMT (358.11 ± 157.02 microns) and NSD height (175.78 ± 134.34 microns) were significantly lower in PG (p = 0.007). Multivariate logistic regression analysis showed that each additional year of age was associated with a 22.3% increase in the odds of having persistent SRF. Conclusion Age at presentation, symptom duration, baseline CMT and NSD height may serve as practical risk stratifiers to identify eyes at high risk for chronicity in CSCR. Key messages What is known Delayed presentation and absence of early therapy predispose eyes to chronic CSCR. SFCT plays a predictive role in persistent CSCR. What is new Age at presentation is a significant predictor of persistent SRF. Baseline CMT and NSD height may serve as practical risk stratifiers to identify eyes at high risk for chronicity.
- 11 October 2025
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 264 (1) , 73-80
Predictors of persistent central serous chorioretinopathy: a multicenter retrospective study – MICRoN report number four
Purpose While central serous chorioretinopathy (CSCR) frequently resolves after the first episode, in 30–50% of cases, subretinal fluid (SRF) persists and can substantially impair vision. To identify persistence predictors, this study compared demographic, clinical, and imaging data between patients with resolution and SRF persistence. Methods Retrospective data were collected at baseline and follow-up from 308 eyes of 295 patients with CSCR in collaboration with the Macula Society CSCR Study Group. Patients were divided into a resolved (RG) and a persistent CSCR group (PG). Patients with known recurrence after resolution were excluded. Optical coherence tomography (OCT) biomarkers including central macular thickness (CMT), subfoveal choroidal thickness (SFCT), neurosensory detachment height (NSD), Haller layer thickness, inner choroidal thickness (ICT), and choroidal vascularity index (CVI) were analysed. Results PG had 148 eyes and RG had 160 eyes. Mean age in PG vs RG was 47.62 ± 11.63 vs. 44.89 ± 10.12 years (p = 0.029). Mean presenting symptom duration was significantly greater in PG than RG (8.67 ± 23.33 vs. 4.33 ± 31.18 months) (p = 0.005). There was a higher frequency of complex cases (21.6%) in PG (p < 0.001). Baseline mean CMT (358.11 ± 157.02 microns) and NSD height (175.78 ± 134.34 microns) were significantly lower in PG (p = 0.007). Multivariate logistic regression analysis showed that each additional year of age was associated with a 22.3% increase in the odds of having persistent SRF. Conclusion Age at presentation, symptom duration, baseline CMT and NSD height may serve as practical risk stratifiers to identify eyes at high risk for chronicity in CSCR. Key messages What is known Delayed presentation and absence of early therapy predispose eyes to chronic CSCR. SFCT plays a predictive role in persistent CSCR. What is new Age at presentation is a significant predictor of persistent SRF. Baseline CMT and NSD height may serve as practical risk stratifiers to identify eyes at high risk for chronicity.
- 16 June 2025
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 35 (6) , 2222-2228
Embossing enhances visualization of retinal pigment epithelium alterations in fundus autofluorescence in central serous chorioretinopathy
Purpose: Central serous chorioretinopathy (CSCR) demonstrates retinal pigment epithelium (RPE) alterations visible on fundus autofluorescence (FAF). Embossing is an image processing technique that replaces pixels with a shadow or a highlight, improving image visualization. We explored how embossing improves the delineation of altered RPE areas in eyes with chronic CSCR on blue-FAF images. Methods: This study includes 52 eyes of 40 patients with chronic CSCR. Images were embossed with a coefficient of 0.5. The area of RPE alteration was assessed by two masked, double-blinded observers using ImageJ Fiji software. Accuracy was assessed based on inter-rater reliability (ICC) and compared before and after embossing using Fisher's z-transformation. Results: The mean age of the study patients was 53.02 ± 12.87 years. The RPE alteration area measurements by the first observer for the pre-embossed images was 12.1 ± 13.1 mm2, and for the post-embossed images was 11.9 ± 13.4 mm2 ( P = 0.7). The RPE alteration area measurements by the second observer for the pre-embossed images was 11.3 ± 13.3 mm2, and for the post-embossed images was 10.3 ± 12.8 mm2 ( P = 0.5). The mean area for both observers in the pre-embossed images was 11.7 ± 12.8 mm2, and in the post-embossed images was 11.1 ± 13.0 mm2 ( P = 0.217). The ICC in the pre-embossed images between two observers was 0.931 (CI 0.879–0.960), which increased to 0.983 (CI 0.970–0.990) in post-embossed images ( P < 0.001). Conclusions: Embossing FAF images can enhance the visibility of RPE alterations in CSCR, allowing for better delineation of borders, which improves accuracy.
- 16 June 2025
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 35 (6) , 2222-2228
Embossing enhances visualization of retinal pigment epithelium alterations in fundus autofluorescence in central serous chorioretinopathy
Purpose: Central serous chorioretinopathy (CSCR) demonstrates retinal pigment epithelium (RPE) alterations visible on fundus autofluorescence (FAF). Embossing is an image processing technique that replaces pixels with a shadow or a highlight, improving image visualization. We explored how embossing improves the delineation of altered RPE areas in eyes with chronic CSCR on blue-FAF images. Methods: This study includes 52 eyes of 40 patients with chronic CSCR. Images were embossed with a coefficient of 0.5. The area of RPE alteration was assessed by two masked, double-blinded observers using ImageJ Fiji software. Accuracy was assessed based on inter-rater reliability (ICC) and compared before and after embossing using Fisher's z-transformation. Results: The mean age of the study patients was 53.02 ± 12.87 years. The RPE alteration area measurements by the first observer for the pre-embossed images was 12.1 ± 13.1 mm2, and for the post-embossed images was 11.9 ± 13.4 mm2 ( P = 0.7). The RPE alteration area measurements by the second observer for the pre-embossed images was 11.3 ± 13.3 mm2, and for the post-embossed images was 10.3 ± 12.8 mm2 ( P = 0.5). The mean area for both observers in the pre-embossed images was 11.7 ± 12.8 mm2, and in the post-embossed images was 11.1 ± 13.0 mm2 ( P = 0.217). The ICC in the pre-embossed images between two observers was 0.931 (CI 0.879–0.960), which increased to 0.983 (CI 0.970–0.990) in post-embossed images ( P < 0.001). Conclusions: Embossing FAF images can enhance the visibility of RPE alterations in CSCR, allowing for better delineation of borders, which improves accuracy.
- Open Access
- 18 October 2024
- Published by Elsevier in Survey of Ophthalmology
- Vol. 70 (2) , 167-183
Choroidal biomarkers in age-related macular degeneration
- 18 October 2024
- Published by Elsevier in Survey of Ophthalmology
- Vol. 70 (2) , 167-183
Open AccessChoroidal biomarkers in age-related macular degeneration
- Open Access
- 3 June 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (6) , 1629
Functional and Morphological Characteristics of the Retina of Patients with Drusen-like Deposits and Systemic Lupus Erythematosus Treated with Hydroxychloroquine: A Retrospective Study
Purpose: To evaluate the impact of drusen-like deposits (DLD) on retinal layer integrity and retinal function by optical coherence tomography (OCT) and multifocal electroretinography (mfERG) in patients with systemic lupus erythematosus (SLE). Methods: We identified 66 eyes of 33 SLE patients treated with hydroxychloroquine (HCQ) that were categorized into two groups according to whether DLDs were present (34 eyes, Group One) or absent (32 eyes, Group Two). The groups were matched for age, sex, HCQ treatment duration, daily, and cumulative dosage. OCT (retinal layer thicknesses, central retinal thickness, CRT) and mfERG concentric ring analysis were analyzed and compared. Results: CRT was significantly thicker in Group One compared to Group Two (273.21 ± 3.96 vs. 254.5 ± 7.62) (p = 0.023). Group One also demonstrated an overall thicker retinal pigment epithelium compared to Group Two; however, the other outer retinal layers, outer nuclear layer, and photoreceptor layer were found to be significantly thinner in Group One compared to Group Two. We found no differences in mfERG parameters between the two groups. Conclusions: DLDs in SLE patients lead to abnormal central retinal layer thickness, which has no measurable impact on cone-mediated retinal function assessed by mfERG.
- 3 June 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (6) , 1629
Open AccessFunctional and Morphological Characteristics of the Retina of Patients with Drusen-like Deposits and Systemic Lupus Erythematosus Treated with Hydroxychloroquine: A Retrospective Study
Purpose: To evaluate the impact of drusen-like deposits (DLD) on retinal layer integrity and retinal function by optical coherence tomography (OCT) and multifocal electroretinography (mfERG) in patients with systemic lupus erythematosus (SLE). Methods: We identified 66 eyes of 33 SLE patients treated with hydroxychloroquine (HCQ) that were categorized into two groups according to whether DLDs were present (34 eyes, Group One) or absent (32 eyes, Group Two). The groups were matched for age, sex, HCQ treatment duration, daily, and cumulative dosage. OCT (retinal layer thicknesses, central retinal thickness, CRT) and mfERG concentric ring analysis were analyzed and compared. Results: CRT was significantly thicker in Group One compared to Group Two (273.21 ± 3.96 vs. 254.5 ± 7.62) (p = 0.023). Group One also demonstrated an overall thicker retinal pigment epithelium compared to Group Two; however, the other outer retinal layers, outer nuclear layer, and photoreceptor layer were found to be significantly thinner in Group One compared to Group Two. We found no differences in mfERG parameters between the two groups. Conclusions: DLDs in SLE patients lead to abnormal central retinal layer thickness, which has no measurable impact on cone-mediated retinal function assessed by mfERG.
- 13 January 2022
- Published by BMJ in BMJ Case Reports
- Vol. 15 (1) , e246911
Unusual presentation of cornea verticillata with intravitreal methotrexate in a case of primary intraocular lymphoma
A 56-year-old woman presented with floaters and diminution of vision in the right eye for 1 week. On examination, visual acuity was 20/400 in the right eye and 20/60 in the left eye. Indirect ophthalmoscopy revealed vitritis in the right eye and subretinal deposits in both eyes. Vitreous biopsy of the right eye revealed large B-cell-type primary intraocular lymphoma and the patient underwent multiple intravitreal methotrexate injections (400 μg/0.1 mL) in the right eye and systemic chemotherapy for bilateral disease. Following biweekly injections of methotrexate, her visual acuity improved considerably from 20/400 to 20/60 with resolution of vitritis. However, following eighth dose of intravitreal methotrexate, she experienced visual decline to 20/120 along with photophobia, redness and watering. Whorl-shaped opacities, limbitis and corneal haze were noted on slit-lamp examination. Intravitreal methotrexate was stopped, and the patient was started on frequent topical lubricants, loteprednol, topical folinic acid and oral folic acid. Complete resolution of corneal toxicity was observed at 3 weeks and the injections were suspended as there was no recurrence at 6 months follow-up.
- 13 January 2022
- Published by BMJ in BMJ Case Reports
- Vol. 15 (1) , e246911
Unusual presentation of cornea verticillata with intravitreal methotrexate in a case of primary intraocular lymphoma
A 56-year-old woman presented with floaters and diminution of vision in the right eye for 1 week. On examination, visual acuity was 20/400 in the right eye and 20/60 in the left eye. Indirect ophthalmoscopy revealed vitritis in the right eye and subretinal deposits in both eyes. Vitreous biopsy of the right eye revealed large B-cell-type primary intraocular lymphoma and the patient underwent multiple intravitreal methotrexate injections (400 μg/0.1 mL) in the right eye and systemic chemotherapy for bilateral disease. Following biweekly injections of methotrexate, her visual acuity improved considerably from 20/400 to 20/60 with resolution of vitritis. However, following eighth dose of intravitreal methotrexate, she experienced visual decline to 20/120 along with photophobia, redness and watering. Whorl-shaped opacities, limbitis and corneal haze were noted on slit-lamp examination. Intravitreal methotrexate was stopped, and the patient was started on frequent topical lubricants, loteprednol, topical folinic acid and oral folic acid. Complete resolution of corneal toxicity was observed at 3 weeks and the injections were suspended as there was no recurrence at 6 months follow-up.