Svea Deppe Mørup
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Svea Deppe Mørup has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Helle Precht
Discipline of Medical Imaging and Radiation Therapy, School of Medicine and Health, University College Cork, Cork, Ireland
5 shared publications - Shane Foley
Radiography and Diagnostic Imaging, School of Medicine, University College Dublin, Belfield, Dublin, Ireland
4 shared publications - Bo Mussmann
Department of Radiology, Odense University Hospital, Sdr. Boulevard 29, 5000 Odense C, Denmark; Department of Clinical Research, University of Southern Denmark, Campusvej 55, 5220, Odense, Denmark; Department of Life Sciences and Health, Oslo Metropolitan University, Pilestedet 48, N-0130 Oslo, Norway
2 shared publications - Jess Lambrechtsen
Department of Clinical Research (A.M., J.L., P.K., A.D., L.M.R., O.G.), University of Southern Denmark, Odense
2 shared publications - John Stowe
University College Dublin Radiography & Diagnostic Imaging, School of Medicine Belfield, Dublin 4 , Ireland
2 shared publications - Karen Brage
Education of Radiography, UCL University College Odense, DK, Denmark; Health Sciences Research Centre, UCL University College, Odense, DK, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, DK, Denmark
2 shared publications
Latest Publications
- Open Access
- 6 November 2026
- Published by Elsevier in European Journal of Radiology Artificial Intelligence
- Vol. 8
Acceptance of AI‑generated scan ranges and manual variability during head CT planning
- 6 November 2026
- Published by Elsevier in European Journal of Radiology Artificial Intelligence
- Vol. 8
Open AccessAcceptance of AI‑generated scan ranges and manual variability during head CT planning
- Open Access
- 20 June 2024
- Published by Elsevier in Radiography
- Vol. 30 (4) , 1219-1224
Perspectives on diagnostic radiographers’ motivation for becoming researchers: A qualitative focus group study
- 20 June 2024
- Published by Elsevier in Radiography
- Vol. 30 (4) , 1219-1224
Open AccessPerspectives on diagnostic radiographers’ motivation for becoming researchers: A qualitative focus group study
- Open Access
- 10 February 2024
- Published by Elsevier in Radiography
- Vol. 30 (2) , 651-658
Radiographers use of social media - SoMe in a Nordic perspective
- 10 February 2024
- Published by Elsevier in Radiography
- Vol. 30 (2) , 651-658
Open AccessRadiographers use of social media - SoMe in a Nordic perspective
- 22 November 2022
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (1) , 79-86
COMBINING HI-RESOLUTION SCAN MODE WITH DEEP LEARNING RECONSTRUCTION ALGORITHMS IN CARDIAC CT
To investigate the impact of combining the high-resolution (Hi-res) scan mode with deep learning image reconstruction (DLIR) algorithm in CT. Two phantoms (Catphan600® and Lungman, small, medium, large size) were CT scanned using combinations of Hi-res/standard mode and high-definition (HD)/standard kernels. Images were reconstructed with ASiR-V and three levels of DLIR. Spatial resolution, noise and contrast-to-noise ratio (CNR) were assessed. The radiation dose was recorded. The spatial resolution increased using Hi-res & HD. Image noise in the Catphan600® (69%) and the Lungman (10–70%) significantly increased when Hi-res & HD was applied. DLIR reduced the mean noise (54%). The CNR was reduced (64%) for Hi-res & HD. The radiation dose increased for both small (+70%) and medium (+43%) Lungman phantoms but decreased slightly for the large ones (−3%) when Hi-res was applied. In conclusion, the Hi-res scan mode improved the spatial resolution. The HD kernel significantly increased the image noise. DLIR improved the image noise and CNR and did not affect the spatial resolution.
- 22 November 2022
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (1) , 79-86
COMBINING HI-RESOLUTION SCAN MODE WITH DEEP LEARNING RECONSTRUCTION ALGORITHMS IN CARDIAC CT
To investigate the impact of combining the high-resolution (Hi-res) scan mode with deep learning image reconstruction (DLIR) algorithm in CT. Two phantoms (Catphan600® and Lungman, small, medium, large size) were CT scanned using combinations of Hi-res/standard mode and high-definition (HD)/standard kernels. Images were reconstructed with ASiR-V and three levels of DLIR. Spatial resolution, noise and contrast-to-noise ratio (CNR) were assessed. The radiation dose was recorded. The spatial resolution increased using Hi-res & HD. Image noise in the Catphan600® (69%) and the Lungman (10–70%) significantly increased when Hi-res & HD was applied. DLIR reduced the mean noise (54%). The CNR was reduced (64%) for Hi-res & HD. The radiation dose increased for both small (+70%) and medium (+43%) Lungman phantoms but decreased slightly for the large ones (−3%) when Hi-res was applied. In conclusion, the Hi-res scan mode improved the spatial resolution. The HD kernel significantly increased the image noise. DLIR improved the image noise and CNR and did not affect the spatial resolution.
- Open Access
Is There Any Improvement in Image Quality in Obese Patients When Using a New X-ray Tube and Deep Learning Image Reconstruction in Coronary Computed Tomography Angiography?
Deep learning image reconstruction (DLIR) is a technique that should reduce noise and improve image quality. This study assessed the impact of using both higher tube currents as well as DLIR on the image quality and diagnostic accuracy. The study consisted of 51 symptomatic obese (BMI > 30 kg/m2) patients with low to moderate risk of coronary artery disease (CAD). All patients underwent coronary computed tomography angiography (CCTA) twice, first with the Revolution CT scanner and then with the upgraded Revolution Apex scanner with the ability to increase tube current. Images were reconstructed using ASiR-V 50% and DLIR. The image quality was evaluated by an observer using a Likert score and by ROI measurements in aorta and the myocardium. Image quality was significantly improved with the Revolution Apex scanner and reconstruction with DLIR resulting in an odds ratio of 1.23 (p = 0.017), and noise was reduced by 41%. A total of 88% of the image sets performed with Revolution Apex + DLIR were assessed as good enough for diagnosis compared to 69% of the image sets performed with Revolution Apex/CT + ASiR-V. In obese patients, the combination of higher tube current and DLIR significantly improves the subjective image quality and diagnostic utility and reduces noise.
Open AccessIs There Any Improvement in Image Quality in Obese Patients When Using a New X-ray Tube and Deep Learning Image Reconstruction in Coronary Computed Tomography Angiography?
Deep learning image reconstruction (DLIR) is a technique that should reduce noise and improve image quality. This study assessed the impact of using both higher tube currents as well as DLIR on the image quality and diagnostic accuracy. The study consisted of 51 symptomatic obese (BMI > 30 kg/m2) patients with low to moderate risk of coronary artery disease (CAD). All patients underwent coronary computed tomography angiography (CCTA) twice, first with the Revolution CT scanner and then with the upgraded Revolution Apex scanner with the ability to increase tube current. Images were reconstructed using ASiR-V 50% and DLIR. The image quality was evaluated by an observer using a Likert score and by ROI measurements in aorta and the myocardium. Image quality was significantly improved with the Revolution Apex scanner and reconstruction with DLIR resulting in an odds ratio of 1.23 (p = 0.017), and noise was reduced by 41%. A total of 88% of the image sets performed with Revolution Apex + DLIR were assessed as good enough for diagnosis compared to 69% of the image sets performed with Revolution Apex/CT + ASiR-V. In obese patients, the combination of higher tube current and DLIR significantly improves the subjective image quality and diagnostic utility and reduces noise.
- 15 July 2022
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 53 (3) , 453-459
The impact of ASiR-V on abdominal CT radiation dose and image quality – A phantom study
- 15 July 2022
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 53 (3) , 453-459
The impact of ASiR-V on abdominal CT radiation dose and image quality – A phantom study
- Open Access
- 1 May 2022
- Published by Elsevier in Radiography
- Vol. 28 (2) , 426-432
Design of a 3D printed coronary artery model for CT optimization
- 1 May 2022
- Published by Elsevier in Radiography
- Vol. 28 (2) , 426-432
Open AccessDesign of a 3D printed coronary artery model for CT optimization
- 1 February 2021
- Published by Elsevier in Radiography
- Vol. 27 (1) , 1-7
Organ-based tube current modulation in chest CT. A comparison of three vendors
- 1 February 2021
- Published by Elsevier in Radiography
- Vol. 27 (1) , 1-7
Organ-based tube current modulation in chest CT. A comparison of three vendors