Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Issa Sy has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Feasibility and current limitations of matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) in identifying adult Moniezia spp. and Thysaniezia connochaeti (Cestoda) after prolonged storage in ethanol

    by Lucie Conrad, Antoine Huguenin, Emmanuel O. Ngbede, Mohammed I. Adah, Saheed T. Yusuf, Franco H. Falcone, Sören L. Becker, Issa Sy

    The cestodes Moniezia spp. and Thysaniezia connochaeti (Fuhrmann, 1943) occur worldwide and mainly affect ruminants. Infection may result in diarrhoea, anaemia and death, especially in young animals. The diagnosis of these cestodes is mainly based on the microscopic examination of faecal specimens to detect the eggs. Molecular techniques, which are more sensitive, are available, but they are also expensive and time-consuming, and require specific expertise. We aimed to evaluate the ability of matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) to identify adult Moniezia spp. and T. connochaeti after prolonged storage in ethanol. Protein extraction was performed, followed by MALDI-TOF MS analysis to generate specific main spectra profiles (MSPs) (n = 9) to be included in an existing in-house ‘Helminths’ database that was used as a reference. The newly expanded in-house database was tested for validation using a new subset of samples. Of 107 samples, 59 (55.1%) (14 M. benedeni and 45 T. connochaeti ) were correctly identified with a log score value (LSV) above 1.7, corresponding to the identification threshold at the genus level. Considering this limited performance, MALDI-TOF MS application for identifying adult Moniezia spp. and T. connochaeti stored in ethanol for a long time is not yet sufficiently effective for routine use.

  • Open Access

    Evaluation of Matrix-Assisted Laser Desorption/Ionization Time-of-Flight (MALDI-TOF) Mass Spectrometry for Identification of Adult Schistosoma mansoni Worms and Eggs

    by Lucie Conrad, Franco H. Falcone, Sören L. Becker, Issa Sy

    Schistosomiasis, a neglected tropical disease (NTD), affects humans and leads to considerable clinical morbidity and severe long-term sequelae. Laboratory diagnostics for Schistosoma mansoni are mainly based on microscopic identification of eggs in stool, but sensitivity varies with infection intensity. Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is the gold standard for bacterial identification in high-income countries. Here, we first evaluate the capacity of MALDI-TOF MS and our existing ‘in-house helminths’ database for the identification of S. mansoni worms and eggs. A subset of adult worms and egg samples was used to generate MALDI reference spectra, which were added to the database and evaluated by blind-test identification. Subsequently, egg-free human stool was spiked with purified S. mansoni eggs and analyzed by MALDI-TOF MS. Log score values (LSVs) were employed to assess the reliability of identification. A total of 62/90 (68.9%, 95% confidence interval (CI): 58.3–78.2%) adult samples were correctly identified. After database expansion, 90/90 (100%, 95% CI: 96.0–100%) and 59/60 (98.3%, 95% CI: 91.1–100%) were correctly identified for adult worms and purified eggs, respectively. In contrast, the analysis of 35 human stool samples spiked with S. mansoni as eggs did not yield identifiable spectra. MALDI-TOF MS can be applied for the identification of isolated adult S. mansoni worms and eggs. Further investigations and optimization are necessary before potential application to clinical samples (e.g., for egg detection in stool).

  • Open Access

    Human strongyloidiasis in rural villages of South Kalimantan, Indonesia: A case series

    by Priska Pp. Kristi, Peni Kusumasari, Puspawati Puspawati, Yurniah Tanzil, Dian Nurmansyah, Muhammad Syairaji, Rizqiani A. Kusumasari, Eti N. Sholikhah, Nina Buehler, Issa Sy, et al.

    Strongyloidiasis, caused by the nematode Strongyloides stercoralis, can lead to severe complications, including hyperinfection syndrome and disseminated disease, particularly in immunocompromised individuals. However, data on its epidemiology and clinical significance in Indonesia remain scarce and outdated. The aim of this study was to investigate the presence of S. stercoralis, identify potential sources of infection, and explore associated risk factors. A case series of strongyloidiasis was identified during a soil-transmitted helminth survey conducted in two villages in Banjar District, South Kalimantan, Indonesia, between May and July 2024. S. stercoralis larvae were detected in four individuals out of 224 fecal samples (1.8%) using the Baermann funnel method, with confirmation via quantitative polymerase chain reaction (qPCR). All infected individuals were female farmers who reported nonspecific clinical symptoms. Subsequent environmental sampling revealed viable S. stercoralis larvae in soil from one of the villages. The detection of asymptomatic, infected individuals suggests that humans serve as reservoirs for ongoing transmission. In the context of open defecation practices, sustained transmission is likely unless targeted interventions are implemented. Urgent actions are needed, including community education and the provision of basic sanitation infrastructure such as latrines and access to clean water. These interventions are especially critical given that ivermectin—the first-line treatment for strongyloidiasis—is not currently available in Indonesia.

  • Open Access

    MALDI-TOF mass spectrometry combined with machine learning algorithms to identify protein profiles related to malaria infection in human sera from Côte d’Ivoire

    by Fateneba Kone, Lucie Conrad, Jean T. Coulibaly, Kigbafori D. Silué, Sören L. Becker, Brama Kone, Issa Sy

    Background: In sub-Saharan Africa, Plasmodium falciparum is the most prevalent species of malaria parasites. In endemic areas, malaria is mainly diagnosed using microscopy or rapid diagnostic tests (RDTs), which have limited sensitivity, and microscopic expertise is waning in non-endemic regions. Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is nowadays the standard method in routine microbiology laboratories for bacteria and fungi identification in high-income countries, but is rarely used for parasite detection. This study aims to employ MALDI-TOF MS for identifying malaria by distinguishing P. falciparum-positive from P. falciparum-negative sera. Methods: Sera were obtained from 282 blood samples collected from non-febrile, asymptomatic people aged 5 to 58 years in southern Côte d’Ivoire. Infectious status and parasitaemia were determined by both RDTs and microscopy, followed by a categorization into two groups (P. falciparum-positive and P. falciparum-negative samples). MALDI-TOF MS analysis was carried out by generating protein spectra profiles from 131 Plasmodium-positive and 94 Plasmodium-negative sera as the training set. Machine learning (ML) algorithms were employed for distinguishing P. falciparum-positive from P. falciparum-negative samples. Subsequently, a subset of 57 sera (42 P. falciparum-positive and 15 P. falciparum-negative) was used as the validation set to evaluate the best two of the four models trained. Results: MALDI-TOF MS was able to generate good-quality spectra from both P. falciparum-positive and P. falciparum-negative serum samples. High similarities between the protein spectra profiles did not allow for distinguishing the two groups using principal component analysis (PCA). When four supervised ML algorithms were tested by tenfold cross-validation, P. falciparum-positive sera were discriminated against P. falciparum-negative sera with a global accuracy ranging from 73.28% to 81.30%, while sensitivity ranged from 70.23% to 83.97%. The independent test performed with a subset of 57 serum samples showed accuracies of 85.96% and 89.47%, and sensitivities of 90.48% and 92.86%, respectively, for LightGBM and RF. Conclusion: MALDI-TOF MS combined with ML might be applied for detection of protein profiles related to P. falciparum malaria infection in human serum samples. Additional research is warranted for further optimization such as specific biomarkers detection or using other ML models. Graphical


  • Open Access

    Evaluation of the Qvella FAST System and the FAST-PBC cartridge for rapid species identification and antimicrobial resistance testing directly from positive blood cultures

    by Issa Sy, Nina Bühler, Sören L. Becker, Philipp Jung

    Blood culture diagnostics require rapid and accurate identification (ID) of pathogens and antimicrobial susceptibility testing (AST). Standard procedures, involving conventional cultivation on agar plates, may take up to 48 hours or more until AST completion. Recent approaches aim to shorten the processing time of positive blood cultures (PBC). The FAST System is a new technology, capable of purifying and concentrating bacterial/fungal pathogens from positive blood culture media and producing a bacterial suspension called “liquid colony” (LC), which can be further used in downstream analyses (e.g., ID and AST). Here, we evaluated the performance of the FAST System LC generated from PBC in comparison to our routine workflow including ID by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using Sepsityper, AST by automatized MicroScan WalkAway plus and directly inoculated disk diffusion (DD), and MICRONAUT-AM for yeast/fungi. A total of 261 samples were analyzed, of which 86.6% (226/261) were eligible for the comparative ID and AST analyses. In comparison to the reference technique (culture-grown colonies), ID concordance of the FAST System LC and Sepsityper was 150/154 (97.4%) and 123/154 (79.9%), respectively, for Gram positive; 67/70 (95.7%) and 64/70 (91.4%), respectively, for Gram negative. For AST, categorical agreement (CA) of the FAST System LC in comparison to the routine workflow for Gram-positive bacteria was 96.1% and 98.7% for MicroScan and DD, respectively. Similar results were obtained for Gram-negative bacteria with 96.6% and 97.5% of CA for MicroScan and DD, respectively. Taken together, the FAST System LC allowed the laboratory to significantly reduce the time to obtain correct ID and AST (automated MicroScan) results 1 day earlier and represents a promising tool to expedite the processing of PBC.


  • Open Access

    Carriage of linezolid-resistant enterococci (LRE) among humans and animals in Nigeria: coexistence of the cfr, optrA, and poxtA genes in Enterococcus faecium of animal origin

    by Emmanuel O. Ngbede, Issa Sy, Chinedu A. Akwuobu, Maurice A. Nanven, Alex A. Adikwu, Paul O. Abba, Mohammed I. Adah, Sören L. Becker


  • Open Access

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for differential identification of adult Schistosoma worms

    by Jurena Christiane Ebersbach, Marcello Otake Sato, Matheus Pereira de Araújo, Megumi Sato, Sören L. Becker, Issa Sy

    Background: Schistosomiasis is a major neglected tropical disease that affects up to 250 million individuals worldwide. The diagnosis of human schistosomiasis is mainly based on the microscopic detection of the parasite’s eggs in the feces (i.e., for Schistosoma mansoni or Schistosoma japonicum) or urine (i.e., for Schistosoma haematobium) samples. However, these techniques have limited sensitivity, and microscopic expertise is waning outside endemic areas. Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) has become the gold standard diagnostic method for the identification of bacteria and fungi in many microbiological laboratories. Preliminary studies have recently shown promising results for parasite identification using this method. The aims of this study were to develop and validate a species-specific database for adult Schistosoma identification, and to evaluate the effects of different storage solutions (ethanol and RNAlater) on spectra profiles. Methods: Adult worms (males and females) of S. mansoni and S. japonicum were obtained from experimentally infected mice. Species identification was carried out morphologically and by cytochrome oxidase 1 gene sequencing. Reference protein spectra for the creation of an in-house MALDI-TOF MS database were generated, and the database evaluated using new samples. We employed unsupervised (principal component analysis) and supervised (support vector machine, k-nearest neighbor, Random Forest, and partial least squares discriminant analysis) machine learning algorithms for the identification and differentiation of the Schistosoma species. Results: All the spectra were correctly identified by internal validation. For external validation, 58 new Schistosoma samples were analyzed, of which 100% (58/58) were correctly identified to genus level (log score values ≥ 1.7) and 81% (47/58) were reliably identified to species level (log score values ≥ 2). The spectra profiles showed some differences depending on the storage solution used. All the machine learning algorithms classified the samples correctly. Conclusions: MALDI-TOF MS can reliably distinguish adult S. mansoni from S. japonicum. Graphical


  • Open Access

    Recent Advances and Potential Future Applications of MALDI-TOF Mass Spectrometry for Identification of Helminths

    by Issa Sy, Lucie Conrad, Sören L. Becker

    Helminth infections caused by nematodes, trematodes, and cestodes are major neglected tropical diseases and of great medical and veterinary relevance. At present, diagnosis of helminthic diseases is mainly based on microscopic observation of different parasite stages, but microscopy is associated with limited diagnostic accuracy. Against this background, recent studies described matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry as a potential, innovative tool for helminth identification and differentiation. MALDI-TOF mass spectrometry is based on the analysis of spectra profiles generated from protein extracts of a given pathogen. It requires an available spectra database containing reference spectra, also called main spectra profiles (MSPs), which are generated from well characterized specimens. At present, however, there are no commercially available databases for helminth identification using this approach. In this narrative review, we summarize recent developments and published studies between January 2019 and September 2022 that report on the use of MALDI-TOF mass spectrometry for helminths. Current challenges and future research needs are identified and briefly discussed.


  • Open Access

    Evaluating Different Storage Media for Identification of Taenia saginata Proglottids Using MALDI-TOF Mass Spectrometry

    by Tabea P. Wendel, Maureen Feucherolles, Jacqueline Rehner, Sven Poppert, Jürg Utzinger, Sören L. Becker, Issa Sy

    Taenia saginata is a helminth that can cause taeniasis in humans and cysticercosis in cattle. A species-specific diagnosis and differentiation from related species (e.g., Taenia solium) is crucial for individual patient management and disease control programs. Diagnostic stool microscopy is limited by low sensitivity and does not allow discrimination between T. saginata and T. solium. Molecular diagnostic approaches are not routinely available outside research laboratories. Recently, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) was proposed as a potentially suitable technique for species-specific helminth diagnosis. However, standardized protocols and commercial databases for parasite identification are currently unavailable, and pre-analytical factors have not yet been assessed. The purpose of this study was to employ MALDI-TOF MS for the identification of T. saginata proglottids obtained from a human patient, and to assess the effects of different sample storage media on the technique’s diagnostic accuracy. We generated T. saginata-specific main spectral profiles and added them to an in-house database for MALDI-TOF MS-based diagnosis of different helminths. Based on protein spectra, T. saginata proglottids could be successfully differentiated from other helminths, as well as bacteria and fungi. Additionally, we analyzed T. saginata proglottids stored in (i) LC–MS grade water; (ii) 0.45% sodium chloride; (iii) 70% ethanol; and (iv) 37% formalin after 2, 4, 6, 8, 12, and 24 weeks of storage. MALDI-TOF MS correctly identified 97.2–99.7% of samples stored in water, sodium chloride, and ethanol, with log-score values ≥2.5, thus indicating reliable species identification. In contrast, no protein spectra were obtained for samples stored in formalin. We conclude that MALDI-TOF-MS can be successfully employed for the identification of T. saginata, and that water, sodium chloride, and ethanol are equally effective storage solutions for prolonged periods of at least 24 weeks.


  • Open Access

    Identification of Adult Fasciola spp. Using Matrix-Assisted Laser/Desorption Ionization Time-of-Flight (MALDI-TOF) Mass Spectrometry

    by Issa Sy, Lena Margardt, Emmanuel O. Ngbede, Mohammed I. Adah, Saheed T. Yusuf, Jennifer Keiser, Jacqueline Rehner, Jürg Utzinger, Sven Poppert, Sören L. Becker

    Fascioliasis is a neglected trematode infection caused by Fasciola gigantica and Fasciola hepatica. Routine diagnosis of fascioliasis relies on macroscopic identification of adult worms in liver tissue of slaughtered animals, and microscopic detection of eggs in fecal samples of animals and humans. However, the diagnostic accuracy of morphological techniques and stool microscopy is low. Molecular diagnostics (e.g., polymerase chain reaction (PCR)) are more reliable, but these techniques are not routinely available in clinical microbiology laboratories. Matrix-assisted laser/desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is a widely-used technique for identification of bacteria and fungi; yet, standardized protocols and databases for parasite detection need to be developed. The purpose of this study was to develop and validate an in-house database for Fasciola species-specific identification. To achieve this goal, the posterior parts of seven adult F. gigantica and one adult F. hepatica were processed and subjected to MALDI-TOF MS to create main spectra profiles (MSPs). Repeatability and reproducibility tests were performed to develop the database. A principal component analysis revealed significant differences between the spectra of F. gigantica and F. hepatica. Subsequently, 78 Fasciola samples were analyzed by MALDI-TOF MS using the previously developed database, out of which 98.7% (n = 74) and 100% (n = 3) were correctly identified as F. gigantica and F. hepatica, respectively. Log score values ranged between 1.73 and 2.23, thus indicating a reliable identification. We conclude that MALDI-TOF MS can provide species-specific identification of medically relevant liver flukes.