Nouf Abd Elmunim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nouf Abd Elmunim has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Mardina Abdullah
Universiti Kebangsaan Malaysia
3 shared publications - Siti Aminah Bahari
Space Science Centre (ANGKASA), Institute of Climate Change, Universiti Kebangsaan Malaysia, Bangi, Malaysia
3 shared publications Bal S. Virdee
Center for Communications Technology, London Metropolitan University, London, UK
2 shared publicationsEsraa Mousa Ali
Communications and Computer Engineering Department, Al-Ahliyya Amman University, Amman, Jordan
2 shared publications- Mohammad Alibakhshikenari
Lero, the Research Ireland Centre for Software, College of Science and Engineering, School of Computer Science, University of Galway, Galway, Ireland
2 shared publications Muhammad Akmal Chaudhary
Department of Electrical and Computer Engineering, Ajman University, Ajman, UAE
2 shared publications
Latest Publications
- Open Access
- 5 October 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
Channel quality predictions assisted by new algorithms for high throughput satellite and 5G systems
Variations in rainfall patterns across different regions reduce the accuracy of existing satellite channel models. As satellite services and 5G applications continue to advance, the development of accurate rain-impairment-aware channel models has become essential. This paper presents a prediction model for rain-induced impairments in High Throughput Satellite (HTS) and 5G satellite-to-land communication channels. The proposed model integrates three novel algorithms designed to characterize and analyze rain-induced attenuation and channel quality. Specifically, these algorithms calculate rain-specific attenuation, effective slant path lengths through rainfall, overall rain-induced attenuation, signal carrier-to-noise ratios, and symbol error rates across three conventional modulation schemes. Additionally, the study introduces a new database detailing rain-induced attenuation on HTS channels, considering various frequencies and rainfall intensities. Results indicate substantial fluctuations in HTS-to-land fade levels and signal quality during rainfall events, which could lead to communication link outages, particularly at higher-order modulation schemes. This study provides practical methods to analyze channel characteristics using actual rainfall measurements, thereby facilitating the effective design and deployment of future HTS and 5G system.
- 5 October 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
Open AccessChannel quality predictions assisted by new algorithms for high throughput satellite and 5G systems
Variations in rainfall patterns across different regions reduce the accuracy of existing satellite channel models. As satellite services and 5G applications continue to advance, the development of accurate rain-impairment-aware channel models has become essential. This paper presents a prediction model for rain-induced impairments in High Throughput Satellite (HTS) and 5G satellite-to-land communication channels. The proposed model integrates three novel algorithms designed to characterize and analyze rain-induced attenuation and channel quality. Specifically, these algorithms calculate rain-specific attenuation, effective slant path lengths through rainfall, overall rain-induced attenuation, signal carrier-to-noise ratios, and symbol error rates across three conventional modulation schemes. Additionally, the study introduces a new database detailing rain-induced attenuation on HTS channels, considering various frequencies and rainfall intensities. Results indicate substantial fluctuations in HTS-to-land fade levels and signal quality during rainfall events, which could lead to communication link outages, particularly at higher-order modulation schemes. This study provides practical methods to analyze channel characteristics using actual rainfall measurements, thereby facilitating the effective design and deployment of future HTS and 5G system.
- Open Access
- 5 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-14
Defected ground structure antenna array with metasurface inspired interlinked CSRR for 5G millimeter wave applications
This paper introduces a high-performance antenna array optimized for 5G millimeter-wave (mm-Wave) applications, efficiently operating within the 25–30 GHz frequency range. Three integrated techniques enhance performance without increasing physical size: First, a Defected Ground Structure (DGS) with a 25 × 25 mm2 square slot and embedded interlinked complementary split-ring resonators (CSRRs) inspired by metasurface (MTS) principles broaden bandwidth and improve impedance matching. Second, four oblique slots (4.5 × 0.4 mm2) placed at the ground plane’s corners enhance impedance matching, isolation, and extend the upper frequency to 30 GHz. Third, slotted radiation patches optimize radiation gain and efficiency. Initially, the design operated at 26.0–26.5 GHz and 27.5–28.0 GHz with a radiation gain of 2.8 dBi and efficiency of 56%. Incorporating DGS with CSRRs expanded bandwidth to 25–30 GHz, increased average radiation gain to 7.75 dBi, and improved efficiency to 68.75%. Introducing oblique slots further elevated the average gain to 9.15 dBi and efficiency to 79.5%. Finally, integrating open-loop slots into radiating patches raised the average gain to 12.4 dBi and efficiency to 86.25%. The final optimized antenna array, measuring 32 × 32 × 0.8 mm3, demonstrates significant improvements in radiation gain and efficiency, making it a compact, lightweight, cost-effective, and practical solution for 5G and other mm-Wave applications.
- 5 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-14
Open AccessDefected ground structure antenna array with metasurface inspired interlinked CSRR for 5G millimeter wave applications
This paper introduces a high-performance antenna array optimized for 5G millimeter-wave (mm-Wave) applications, efficiently operating within the 25–30 GHz frequency range. Three integrated techniques enhance performance without increasing physical size: First, a Defected Ground Structure (DGS) with a 25 × 25 mm2 square slot and embedded interlinked complementary split-ring resonators (CSRRs) inspired by metasurface (MTS) principles broaden bandwidth and improve impedance matching. Second, four oblique slots (4.5 × 0.4 mm2) placed at the ground plane’s corners enhance impedance matching, isolation, and extend the upper frequency to 30 GHz. Third, slotted radiation patches optimize radiation gain and efficiency. Initially, the design operated at 26.0–26.5 GHz and 27.5–28.0 GHz with a radiation gain of 2.8 dBi and efficiency of 56%. Incorporating DGS with CSRRs expanded bandwidth to 25–30 GHz, increased average radiation gain to 7.75 dBi, and improved efficiency to 68.75%. Introducing oblique slots further elevated the average gain to 9.15 dBi and efficiency to 79.5%. Finally, integrating open-loop slots into radiating patches raised the average gain to 12.4 dBi and efficiency to 86.25%. The final optimized antenna array, measuring 32 × 32 × 0.8 mm3, demonstrates significant improvements in radiation gain and efficiency, making it a compact, lightweight, cost-effective, and practical solution for 5G and other mm-Wave applications.
- Open Access
- 9 May 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (5) , 762
Correction: Elnumin et al. Evaluating the Performance of IRI-2016 Using GPS-TEC Measurements over the Equatorial Region. Atmosphere 2021, 12, 1243
- 9 May 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (5) , 762
Open AccessCorrection: Elnumin et al. Evaluating the Performance of IRI-2016 Using GPS-TEC Measurements over the Equatorial Region. Atmosphere 2021, 12, 1243
- Open Access
- 23 September 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (10) , 1243
Evaluating the Performance of IRI-2016 Using GPS-TEC Measurements over the Equatorial Region
Total electron content (TEC) is an important parameter in the ionosphere that is extensively used to study the variability of the ionosphere as it significantly affects radio wave propagations, causing delays on GPS signals. Therefore, evaluating the performance of ionospheric models is crucial to reveal the variety of ionospheric behaviour in different solar activity periods during geomagnetically quiet and disturbed periods for further improvements of the IRI model performance over the equatorial region. This research aimed to investigate the variations of ionospheric VTEC and observe the improvement in the performance of the IRI-2016 (IRI-2001, IRI01-corr, and NeQuick). The IRI-2016 was evaluated with the IRI-2012 using NeQuick, IRI-2001, and IRI01-corr topside electron density options. The data were obtained using a dual-frequency GPS receiver installed at the Universiti Utara Malaysia Kedah (UUMK) (geographic coordinates 4.62° N–103.21° E, geomagnetic coordinates 5.64° N–174.98° E), Mukhtafibillah (MUKH) (geographic coordinates 6.46° N–100.50° E, geomagnetic coordinates 3.32° S–172.99° E), and Tanjung Pengerang (TGPG) (geographic coordinates 1.36° N–104.10°E, geomagnetic coordinates 8.43° S–176.53° E) stations, during ascending to high solar activity at the geomagnetically quiet and disturbed periods in October 2011, March 2012, and March 2013. The maximum hourly ionospheric VTEC was observed during the post-noon time, while the minimum was during the early morning time. The ionospheric VTEC modelled by IRI-2016 had a slight improvement from the IRI-2012. However, the differences were observed during the post-noon and night-time, while the modelled VTEC from both IRI models were almost similar during the early morning time. Regarding the daily quiet and disturbed period’s prediction capability of the IRI-2016 and IRI-2012, IRI-2016 gave better agreement with the measured VTEC. The overall results showed that the model’s prediction performance during the high solar activity period in 2013 was better than the one during the ascending solar activity period. The results of the comparison between IRI-2016 and IRI-2012 in high solar activity exhibited that during quiet periods, all the IRI models showed better agreement with the measured VTEC compared to the disturbed periods.
- 23 September 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (10) , 1243
Open AccessEvaluating the Performance of IRI-2016 Using GPS-TEC Measurements over the Equatorial Region
Total electron content (TEC) is an important parameter in the ionosphere that is extensively used to study the variability of the ionosphere as it significantly affects radio wave propagations, causing delays on GPS signals. Therefore, evaluating the performance of ionospheric models is crucial to reveal the variety of ionospheric behaviour in different solar activity periods during geomagnetically quiet and disturbed periods for further improvements of the IRI model performance over the equatorial region. This research aimed to investigate the variations of ionospheric VTEC and observe the improvement in the performance of the IRI-2016 (IRI-2001, IRI01-corr, and NeQuick). The IRI-2016 was evaluated with the IRI-2012 using NeQuick, IRI-2001, and IRI01-corr topside electron density options. The data were obtained using a dual-frequency GPS receiver installed at the Universiti Utara Malaysia Kedah (UUMK) (geographic coordinates 4.62° N–103.21° E, geomagnetic coordinates 5.64° N–174.98° E), Mukhtafibillah (MUKH) (geographic coordinates 6.46° N–100.50° E, geomagnetic coordinates 3.32° S–172.99° E), and Tanjung Pengerang (TGPG) (geographic coordinates 1.36° N–104.10°E, geomagnetic coordinates 8.43° S–176.53° E) stations, during ascending to high solar activity at the geomagnetically quiet and disturbed periods in October 2011, March 2012, and March 2013. The maximum hourly ionospheric VTEC was observed during the post-noon time, while the minimum was during the early morning time. The ionospheric VTEC modelled by IRI-2016 had a slight improvement from the IRI-2012. However, the differences were observed during the post-noon and night-time, while the modelled VTEC from both IRI models were almost similar during the early morning time. Regarding the daily quiet and disturbed period’s prediction capability of the IRI-2016 and IRI-2012, IRI-2016 gave better agreement with the measured VTEC. The overall results showed that the model’s prediction performance during the high solar activity period in 2013 was better than the one during the ascending solar activity period. The results of the comparison between IRI-2016 and IRI-2012 in high solar activity exhibited that during quiet periods, all the IRI models showed better agreement with the measured VTEC compared to the disturbed periods.
- Open Access
- 26 May 2020
- Published by Instituto Nazionale di Geofisica e Vulcanologia, INGV in Annals of Geophysics
- Vol. 63 (2) , PA211
Characterization of Ionospheric Delay and Forecasting Using GPS-TEC over Equatorial Region
This paper investigates the characteristic of the ionospheric delay and forecasting using modified statistical Holt-Winter method over Malaysia. This was carried out by using dual frequency GPS Ionospheric Scintillation and TEC Monitor (GISTM) receivers installed at the National University of Malaysia (UKM) (geographic coordinates 2.55°N, 101.46°E and geomagnetic coordinates 7.10°S, 174.05°E), and Langkawi national observatory (Langkawi) (geographical coordinates 6.19°N, 99.51°E and geomagnetic coordinates 3.39°S, 172.42°E), during 2011. In this work, the Holt-Winter forecasting method is modified to provide a better forecasting result over Malaysia. The diurnal, monthly, and seasonal variations of actual ionospheric delay have been analyzed and compared with forecasted ionospheric delay. Based on the results, the diurnal variability of ionospheric delay was maximal mostly between 12:00– 17:00 LT, and minimal nearly at 05:00 LT. The maximum monthly ionospheric delays occurred in October, which is attributed to the geomagnetic storm disturbance that caused increase in ionospheric delay. The lowest seasonal ionospheric delay occurred in the summer and the highest was during the equinox. The maximum ionospheric delay on a quiet day was around 41.9 TECU, while it reached up to 86.6 TECU during the geomagnetic storm. The Holt-Winter method exhibited the highest difference between the measurements and the forecasts in March, with an error of 6%. Hence, the modified Holt-Winter method forecast ionospheric delay effectively during quiet and disturbed periods over Malaysia.
- 26 May 2020
- Published by Instituto Nazionale di Geofisica e Vulcanologia, INGV in Annals of Geophysics
- Vol. 63 (2) , PA211
Open AccessCharacterization of Ionospheric Delay and Forecasting Using GPS-TEC over Equatorial Region
This paper investigates the characteristic of the ionospheric delay and forecasting using modified statistical Holt-Winter method over Malaysia. This was carried out by using dual frequency GPS Ionospheric Scintillation and TEC Monitor (GISTM) receivers installed at the National University of Malaysia (UKM) (geographic coordinates 2.55°N, 101.46°E and geomagnetic coordinates 7.10°S, 174.05°E), and Langkawi national observatory (Langkawi) (geographical coordinates 6.19°N, 99.51°E and geomagnetic coordinates 3.39°S, 172.42°E), during 2011. In this work, the Holt-Winter forecasting method is modified to provide a better forecasting result over Malaysia. The diurnal, monthly, and seasonal variations of actual ionospheric delay have been analyzed and compared with forecasted ionospheric delay. Based on the results, the diurnal variability of ionospheric delay was maximal mostly between 12:00– 17:00 LT, and minimal nearly at 05:00 LT. The maximum monthly ionospheric delays occurred in October, which is attributed to the geomagnetic storm disturbance that caused increase in ionospheric delay. The lowest seasonal ionospheric delay occurred in the summer and the highest was during the equinox. The maximum ionospheric delay on a quiet day was around 41.9 TECU, while it reached up to 86.6 TECU during the geomagnetic storm. The Holt-Winter method exhibited the highest difference between the measurements and the forecasts in March, with an error of 6%. Hence, the modified Holt-Winter method forecast ionospheric delay effectively during quiet and disturbed periods over Malaysia.