Jian Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jian Liu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Hong Mao
Astec Power, 35 New England Business Center, Andover, MA 01810, USA
1 shared publicationHong-Li Cheng
School of Electrical and Control Engineering, Xi’an University of Science and Technology, Xi’an, China
1 shared publication- Jian-Xin Wang
Electrical and Control Engineering College, Xi'an University of Science & Technology, Xi'an 710054, China
1 shared publication - Jian-Yuan Wang
Department of Electrical Engineering, Xi’an University of Technology, Xi’an, China
1 shared publication Jing-Qiu Xu
School of Electrical and Control Engineering, Xi’an University of Science and Technology, Xi’an, China
1 shared publicationLi Ze
Beijing State Grid Unite Power Co. Ltd. Beijing 100080. China
1 shared publication
Latest Publications
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
The Application of GSM and GPRS Technology in Monitoring System for HVDC System Earth Pole
The paper presented application and realization of GSM and GPRS network in on-line monitoring system of earth pole system. In its on-site unit, which is solar energy technology, the value of the current, temperature and depth of water variables are obtained from different sensors . These data are preprocessed in a DSP chip and then transmitted GSM and GPRS wireless communication networks. Based on software of system management ,the operating condition of HVDC system earth pole can be diagnosed. The monitoring system raise the fault alarm for based on SM.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
The Application of GSM and GPRS Technology in Monitoring System for HVDC System Earth Pole
The paper presented application and realization of GSM and GPRS network in on-line monitoring system of earth pole system. In its on-site unit, which is solar energy technology, the value of the current, temperature and depth of water variables are obtained from different sensors . These data are preprocessed in a DSP chip and then transmitted GSM and GPRS wireless communication networks. Based on software of system management ,the operating condition of HVDC system earth pole can be diagnosed. The monitoring system raise the fault alarm for based on SM.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Improved Approach to Theoretical Losses Analysis of Oil Field Distribution Networks
Not considering the periodic fast fluctuation of the loads of oil pumps, the results of traditional methods of theoretical line losses calculation are much lower than that measured in the practice. To solve above problem, an improved approach is put forward. The distinguishing feature of the loads of oil pumps, i.e., the active power varies periodically with its averaged value not changed while the reactive power maintains approximately unchanged, is made full used of. The active power of an oil pump is formulated in a sine form. In calculation of losses in a feeder or a transformer with many oil pumps, the integral function is simplified by utilizing the orthogonal behavior of sine functions. Combining the proposed approach with the effective current based method, the theoretical losses calculation with hybrid loads of oil pumps and residential customers is deduced. The way to further improve the proposed approach by taking the losses of the downstream devices is discussed. The loss of a typical feeder with 19 loads of Daqing oil filed is calculated by the proposed approach and the traditional method, respectively. Comparison with the measured value shows that the proposed approach is feasible and more accurate.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Improved Approach to Theoretical Losses Analysis of Oil Field Distribution Networks
Not considering the periodic fast fluctuation of the loads of oil pumps, the results of traditional methods of theoretical line losses calculation are much lower than that measured in the practice. To solve above problem, an improved approach is put forward. The distinguishing feature of the loads of oil pumps, i.e., the active power varies periodically with its averaged value not changed while the reactive power maintains approximately unchanged, is made full used of. The active power of an oil pump is formulated in a sine form. In calculation of losses in a feeder or a transformer with many oil pumps, the integral function is simplified by utilizing the orthogonal behavior of sine functions. Combining the proposed approach with the effective current based method, the theoretical losses calculation with hybrid loads of oil pumps and residential customers is deduced. The way to further improve the proposed approach by taking the losses of the downstream devices is discussed. The loss of a typical feeder with 19 loads of Daqing oil filed is calculated by the proposed approach and the traditional method, respectively. Comparison with the measured value shows that the proposed approach is feasible and more accurate.
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1-6
Analysis and Design of Boost DC-DC Converters for Intrinsic Safety
An improved boost DC-DC converter meeting the requirements of intrinsic safety is presented. The maximum values of output short-circuit discharged energy (OSDE) in CCM and DCM are analyzed, respectively. It is pointed out that the OSDE of a boost converter is the summation of the energy from the source and the inductor and the energy stored in the capacitor. It is proved that the maximal value of OSDE (MOSDE) in CCM is the largest within the total operating range. Once MOSDE is less than the minimum ignition discharged energy, the converter meets the requirement of output intrinsic safety. The design method of inductor and capacitor is proposed according to the requirement of output intrinsic safety and the desired output voltage ripple level within the total ranges of input voltage and the load. Experiment results are in positive with the analysis showing the feasibility of the described methods
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1-6
Analysis and Design of Boost DC-DC Converters for Intrinsic Safety
An improved boost DC-DC converter meeting the requirements of intrinsic safety is presented. The maximum values of output short-circuit discharged energy (OSDE) in CCM and DCM are analyzed, respectively. It is pointed out that the OSDE of a boost converter is the summation of the energy from the source and the inductor and the energy stored in the capacitor. It is proved that the maximal value of OSDE (MOSDE) in CCM is the largest within the total operating range. Once MOSDE is less than the minimum ignition discharged energy, the converter meets the requirement of output intrinsic safety. The design method of inductor and capacitor is proposed according to the requirement of output intrinsic safety and the desired output voltage ripple level within the total ranges of input voltage and the load. Experiment results are in positive with the analysis showing the feasibility of the described methods
- 1 June 2006
- Published by Springer Nature in Frontiers of Electrical and Electronic Engineering in China
- Vol. 1 (2) , 205-210
Fast restoration of large area breakdown for power distribution systems
- 1 June 2006
- Published by Springer Nature in Frontiers of Electrical and Electronic Engineering in China
- Vol. 1 (2) , 205-210
Fast restoration of large area breakdown for power distribution systems
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2160133X,p. 1088-1091
A Corrosion Diagnosis Approach for Grounding Grids Based on Tabu Search Algorithm
In order to detect the corrosion of grounding grids, a corrosion diagnosis approach based on Tabu search (TS) algorithm is put forward. A grounding grid is excited between couples of touchable nodes by a current source. Some voltages of touchable nodes are measured in each excitation. Minimizing the energy of the error between testing voltages and evaluation voltages is used as the index. The designed values of branches are used as the initial values. A Tabu list is formed for the branches. In each step of iteration, the resistance of each branch is increased and decreased with a certain value, respectively, forming a set of neighborhood. The aspiration criterion and stop criterion are adopted. An experimental grounding grid with sixty branches is used as an example to show the feasibility of the proposed approach. It is also shown that the proposed approach has the advantage of less sensitivity to testing errors
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2160133X,p. 1088-1091
A Corrosion Diagnosis Approach for Grounding Grids Based on Tabu Search Algorithm
In order to detect the corrosion of grounding grids, a corrosion diagnosis approach based on Tabu search (TS) algorithm is put forward. A grounding grid is excited between couples of touchable nodes by a current source. Some voltages of touchable nodes are measured in each excitation. Minimizing the energy of the error between testing voltages and evaluation voltages is used as the index. The designed values of branches are used as the initial values. A Tabu list is formed for the branches. In each step of iteration, the resistance of each branch is increased and decreased with a certain value, respectively, forming a set of neighborhood. The aspiration criterion and stop criterion are adopted. An experimental grounding grid with sixty branches is used as an example to show the feasibility of the proposed approach. It is also shown that the proposed approach has the advantage of less sensitivity to testing errors