Soami Piara Satsangee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Soami Piara Satsangee has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Deepak Singh Rajawat
IIS University
4 shared publicationsShalini Srivastava
Dayalbagh Educational Institute
3 shared publicationsAbhishek Kardam
Amity Institute of Advanced Research and Studies, Amity University, Noida, India
2 shared publications- Abhishek Kardam
Amity University
1 shared publication - Deepak Singh Rajawat
Department of Chemistry, IIS (deemed to be University), Jaipur, India
1 shared publication Nitin Kumar
Department of Chemistry, MLS University, Udaipur 313001, India
1 shared publication
Latest Publications
- 4 May 2015
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 5 (3) , 140-148
Real Time Measurement of Biosorption Efficiency of Chemically Modified Coconut Powder for Pb(II) and Cd(II) Using Open Circuit Potential
The present communication reports a new method for the potentiometric determination of adsorbent efficiency of coconut shell powder for removal of lead and cadmium from water. A three-electrode system containing metal-coated copper wire electrode was used as a working electrode. At equilibrium Open Circuit Potential (OCP) values represents metal ion concentration in solution. With the addition of coconut powder an appreciable decrease in the OCP was observed, which is associated with the reduction of the metal ion concentration due to the uptake of metal ions by the coconut powder. Chemical modification of coconut biomass was carried out by graft co-polymerization of acrylic acid. Modified biopolymer has been characterized using FTIR technique. An increase in the adsorbent efficiency of the biomass was observed by graft-copolymerized biopolymer i.e. from 54.4 mg/g to 122.1 mg/g and 58.8 mg/g to 141 mg/g respectively for Pb (II) and Cd (II) ions. The OCP based method provides an easy and simple approach for real time measurement of adsorption efficiency, which is a low cost and less time consuming process.
- 4 May 2015
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 5 (3) , 140-148
Real Time Measurement of Biosorption Efficiency of Chemically Modified Coconut Powder for Pb(II) and Cd(II) Using Open Circuit Potential
The present communication reports a new method for the potentiometric determination of adsorbent efficiency of coconut shell powder for removal of lead and cadmium from water. A three-electrode system containing metal-coated copper wire electrode was used as a working electrode. At equilibrium Open Circuit Potential (OCP) values represents metal ion concentration in solution. With the addition of coconut powder an appreciable decrease in the OCP was observed, which is associated with the reduction of the metal ion concentration due to the uptake of metal ions by the coconut powder. Chemical modification of coconut biomass was carried out by graft co-polymerization of acrylic acid. Modified biopolymer has been characterized using FTIR technique. An increase in the adsorbent efficiency of the biomass was observed by graft-copolymerized biopolymer i.e. from 54.4 mg/g to 122.1 mg/g and 58.8 mg/g to 141 mg/g respectively for Pb (II) and Cd (II) ions. The OCP based method provides an easy and simple approach for real time measurement of adsorption efficiency, which is a low cost and less time consuming process.
- 31 October 2014
- Published by Springer Nature in National Academy Science Letters
- Vol. 37 (6) , 547-553
Mercury Free Anodic Stripping Voltammetric Determination of Pb(II) Using a Low Cost “Cocos nucifera” Shell Modified Carbon Paste Electrodes
- 31 October 2014
- Published by Springer Nature in National Academy Science Letters
- Vol. 37 (6) , 547-553
Mercury Free Anodic Stripping Voltammetric Determination of Pb(II) Using a Low Cost “Cocos nucifera” Shell Modified Carbon Paste Electrodes
- Open Access
- 8 May 2014
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 5 (1) , 19
Trace determination of cadmium in water using anodic stripping voltammetry at a carbon paste electrode modified with coconut shell powder
Background: Increasing awareness on the environmental impact of heavy metals has increased a considerable interest in the determination of metals in natural water bodies. The present paper describes the development and electrochemical application of carbon paste electrode modified with fibrous part of coconut shell for the determination of cadmium in water samples.Methods: Determination was carried out using anodic stripping voltammetry. It is a two-step process. First, the metal ions get accumulated at the electrode surface at open-circuit potential, followed by a potential scan for voltammetric determination of cadmium.Results: Different parameters affecting the determination of Cd (II) were optimized and are as follows: HCl as stripping solvent, acetate buffer of pH 5 as accumulating solvent, and 15-min accumulation time. Triton X-100, cetyltrimethylammonium bromide, and sodium dodecyl sulfate were used as representative for neutral, cationic, and anionic surfactants, respectively, to see the effect of surface active macromolecules. Interference caused by other metal ions on the determination of cadmium was also studied.Conclusions: The method shows the development of a sensor for the sensitive determination of cadmium with limit of detection at 105 μg L−1. This technique does not use mercury and, therefore, has a positive environmental benefit.
- 8 May 2014
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 5 (1) , 19
Open AccessTrace determination of cadmium in water using anodic stripping voltammetry at a carbon paste electrode modified with coconut shell powder
Background: Increasing awareness on the environmental impact of heavy metals has increased a considerable interest in the determination of metals in natural water bodies. The present paper describes the development and electrochemical application of carbon paste electrode modified with fibrous part of coconut shell for the determination of cadmium in water samples.Methods: Determination was carried out using anodic stripping voltammetry. It is a two-step process. First, the metal ions get accumulated at the electrode surface at open-circuit potential, followed by a potential scan for voltammetric determination of cadmium.Results: Different parameters affecting the determination of Cd (II) were optimized and are as follows: HCl as stripping solvent, acetate buffer of pH 5 as accumulating solvent, and 15-min accumulation time. Triton X-100, cetyltrimethylammonium bromide, and sodium dodecyl sulfate were used as representative for neutral, cationic, and anionic surfactants, respectively, to see the effect of surface active macromolecules. Interference caused by other metal ions on the determination of cadmium was also studied.Conclusions: The method shows the development of a sensor for the sensitive determination of cadmium with limit of detection at 105 μg L−1. This technique does not use mercury and, therefore, has a positive environmental benefit.
- 20 April 2013
- Published by Springer Nature in National Academy Science Letters
- Vol. 36 (2) , 181-189
Adsorptive Stripping Voltammetric Technique for Monitoring of Mercury Ions in Aqueous Solution Using Nano Cellulosic Fibers Modified Carbon Paste Electrode
- 20 April 2013
- Published by Springer Nature in National Academy Science Letters
- Vol. 36 (2) , 181-189
Adsorptive Stripping Voltammetric Technique for Monitoring of Mercury Ions in Aqueous Solution Using Nano Cellulosic Fibers Modified Carbon Paste Electrode
- 4 October 2012
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 20 (5) , 3068-3076
Nanocellulosic fiber-modified carbon paste electrode for ultra trace determination of Cd (II) and Pb (II) in aqueous solution
In recent years, increasing awareness of the environmental impact of heavy metals has prompted a demand for monitoring and decontaminating industrial wastes prior to discharging into natural water bodies. This paper describes the preparation and electrochemical application of carbon paste electrode modified with nanocellulosic fibers for the determination of cadmium and lead in water samples using anodic stripping voltammetry. First, cadmium and lead were adsorbed on the carbon paste electrode surface at open circuit potential, followed by anodic stripping voltammetric scan from -1 to 0 V. Different factors affecting sensitivity and precision of the electrode, including accumulating solvent, pH of the accumulating solvent, accumulation time, supporting electrolyte, and scan rate were investigated. The proposed method was also applied to the determination of Cd (II) and Pb (II) in the presence of other interfering metal ions and cetyl trimethyl ammonium bromide, sodium dodecyl sulfate, and Triton X-100 as a representative of cationic, anionic, and neutral surfactants. Linear calibration curves were obtained in the concentration ranges of 150–650 μg L−1 and 80–300 μg L−1, respectively, for cadmium and lead at an accumulated time of 10 min with limits of detection 88 and 33 μg L−1. Optimized working conditions are defined as acetate buffer of pH 5 as accumulating solvent, hydrochloric acid as supporting electrolyte, and scan rate 50 mV/s. This technique does not use mercury and therefore has a positive environmental benefit. The method is reasonably sensitive and selective and has been successfully applied to the determination of trace amounts of Cd (II) and Pb (II) in water samples.
- 4 October 2012
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 20 (5) , 3068-3076
Nanocellulosic fiber-modified carbon paste electrode for ultra trace determination of Cd (II) and Pb (II) in aqueous solution
In recent years, increasing awareness of the environmental impact of heavy metals has prompted a demand for monitoring and decontaminating industrial wastes prior to discharging into natural water bodies. This paper describes the preparation and electrochemical application of carbon paste electrode modified with nanocellulosic fibers for the determination of cadmium and lead in water samples using anodic stripping voltammetry. First, cadmium and lead were adsorbed on the carbon paste electrode surface at open circuit potential, followed by anodic stripping voltammetric scan from -1 to 0 V. Different factors affecting sensitivity and precision of the electrode, including accumulating solvent, pH of the accumulating solvent, accumulation time, supporting electrolyte, and scan rate were investigated. The proposed method was also applied to the determination of Cd (II) and Pb (II) in the presence of other interfering metal ions and cetyl trimethyl ammonium bromide, sodium dodecyl sulfate, and Triton X-100 as a representative of cationic, anionic, and neutral surfactants. Linear calibration curves were obtained in the concentration ranges of 150–650 μg L−1 and 80–300 μg L−1, respectively, for cadmium and lead at an accumulated time of 10 min with limits of detection 88 and 33 μg L−1. Optimized working conditions are defined as acetate buffer of pH 5 as accumulating solvent, hydrochloric acid as supporting electrolyte, and scan rate 50 mV/s. This technique does not use mercury and therefore has a positive environmental benefit. The method is reasonably sensitive and selective and has been successfully applied to the determination of trace amounts of Cd (II) and Pb (II) in water samples.