ABA. A. Budaev

A. A. Budaev

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


A. A. Budaev has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The possibilities of chemical and physical modification of cortical bone grafts′ surface in order to increase their adhesive attractiveness to human cells

    by M. S. Makarov, M. V. Storozheva, A. A. Ofitserov, I. N. Ponomarev, A. S. Mironov, A. A. Budaev, N. V. Borovkova

    Introduction . The ability of cells to adhere on bone graft increases its reparative and regenerative properties. The native cortical bone has a very low biological conductivity, which greatly impedes cell migration and adhesion. Various methods of bone surface modification can be used to enhance the bioconductive properties of bone grafts. Objective . To evaluate the adhesion and proliferative activity of human cells on the surface of cortical bone grafts modified by various methods. Material and methods . Fragments of cortical bone grafts (CBGs) were used in the study. For physical modification the outer surface of the bone fragments was processed with a flat file with high or low density of grinding teeth. A 2N hydrochloric acid (HCl) solution, 0.005% collagenase I solution, and the collagenolytic enzyme preparation Fermenkol (0.05 mg/mL) were used for chemical modification. In vitro studies of the CBG adhesion were performed in culture of human fibroblasts M-22 line. Untreated CBGs (control) and modified CBGs were placed in the wells of culture vials; a cell suspension containing 10,000 cells was added to each well. Cells were cultured for 7 days. Results . After 3 days of cultivation, the cells were completely absent or detected in very small numbers on the control CBG samples and CBG samples subjected to mechanical processing. On CBGs treated with 2N hydrochloric acid solution for 3 and 6 hours, the average cell density on the CBG surface estimated 1.0–1.2 thousand/cm 2 ; on CBGs treated with 2N hydrochloric acid solution for 12 hours, the CBG adhesiveness acutely decreased. The highest cell density was observed on CBGs, treated with 0.005% collagenase 1 or Fermencol for 24 hours and amounted to 2.0–2.5 thousand/cm 2 . After 7 days of cultivation, the cell growth was completely absent on the control CBGs, on CBGs processed with a file with a high grinding tooth density, and CBGs treated with 2N hydrochloric acid solution for 12 hours. In experiments with collagenase 1 and Fermencol, as well as in experiments with the treatment with a 2N hydrochloric acid solution for 3 hours, an intensive cell growth was observed on the CBG surface, density of human fibroblasts of the M-22 line and their total number on CBGs increased 3–5-fold without affecting their viability. Conclusion . Physical modification did not effectively increase the adhesiveness of cortical bone grafts. Effectiveness of chemical modification depends on the duration of exposure to the chemical agent. To increase the adhesion, the cortical bone graft should be optimally treated either with 2N hydrochloric acid solution for 3 hours, or 0.005% collagenase 1 solution for 24 hours, or with Fermencol (0.05 mg/mL) for 24 hours.

  • Open Access

    Problems and prospects of bone-cartilage grafts′ preservation

    by A. A. Budaev, M. S. Makarov, N. V. Borovkova, A. A. Ofitcerov, I. N. Ponomarev, I. Yu. Miguleva

    Introduction . Articular hyaline cartilage has special structural and functional characteristics, which are critically important for preserving tissue grafts, containing cartilage elements. Allogeneic bone-cartilage grafts (BCG) could be very perspective in the treatment of joint defects. However, the widespread clinical use of BCG shows significant difficulties, associated with effective choice of preservation and sterilization methods. The aim of the study was to analyze modern methods of allogeneic BCG-preserving, according to their effect on the structural integrity of tissue, biomechanical properties and cellular viability. Material and methods . We systematized data from scientific publications selected in the Scopus, PubMed, eLibrary, and CyberLeninka databases for the period from 1980 to 2024, with a focus on research published over the past 15 years. Results . Cryopreservation is considered as the most convenient method for long-term storage of BCG, however, its effectiveness significantly depends on the optimization of protocols, including the selection of adequate cryoprotectors, freezing and thawing modes. Lyophilization successfully allows to preserve bone part of BCG, but it causes significant deformation of cartilaginous part, loss of its structural organization and mechanical properties. BCG-storage in liquid culture media and solutions ensures short-term preservation of the graft (about 2–3 weeks), longer storage is accompanied with progressive decrease of biomechanical characteristics and the development of matrix edema. The use of chemical agents (aldehydes, alcohols, glycerol) for BCG-preservation seems impractical due to their pronounced cytotoxic effect and negative effect on tissue architecture. Supercritical CO 2 treatment is considered as potentially promising method, targeted on combining tissue sterilization and preservation of structural properties. Conclusion . The development of effective methods for preserving allogeneic BCG, ensuring the maintenance of their structural and functional characteristics, remains an urgent interdisciplinary task, requiring integration of advances in cell biology, cryobiology and tissue engineering. At the current stage, cryopreservation is the most reasonable approach, while other methods require further experimental and clinical verification.

  • Open Access

    Clinical efficacy of injectable autologous platelet preparations in patients after arthroscopic repair of the anterior cruciate ligament

    by A. A. Budaev, M. S. Makarov, N. V. Borovkova, A. M. Fain, K. I. Skuratovskaya, M. V. Storozheva, A. Yu. Vaza, I. I. Mazhorova

    Background. Platelet-rich plasma (PRP) can be used in the treatment of knee joint defects, including relief of complications in the early postoperative period after arthroscopic repair of the anterior cruciate ligament. Low-pulse laser radiation (LPLR) with wavelength 635 nm stimulates the platelet activity in PRP and increases their realization of reparative potential.Objective. To evaluate the clinical effect of injectable autologous platelet preparations in patients in the early postoperative period after arthroscopic repair of the anterior cruciate ligament.Material and methods. The study included 45 patients, who underwent arthroscopic prosthetics of the anterior cruciate ligament or its fixation to the place of attachment. The patients were divided into 3 groups: in the 1st group (15 people) the operation was performed without using platelet preparations (the comparison group); in the 2nd group (15 people), non-activated autologous PRP was intraoperatively administered; in the 3rd group (15 people), LPLR-activated autologous PRP was intraoperatively administered. The PRP was exposed to LPLR with wavelength 635 nm and power 2 W for 10 minutes. Two ml of the autologous platelet-rich preparation were injected intra-articularly; additionally 1 ml of the same preparation was applied in a fan-like pattern to the surrounding soft tissues.Results. After surgery patients in comparison group had moderate acute pain syndrome, while patients in main groups did not complain about severe pain in the area of surgery. The use of autologous PRP-preparations significantly reduced pain assessments by Visual Analogue Scale by 1.5 times in the 2nd group and 3 times in the 3rd group, comparing to patients without PRP treatment (pConclusions. Intra- and periarticular administration of non-activated and LPLR-activated PRP allowed to reduce pain and the incidence of hemarthrosis after knee surgery. The use of LPLR-activated PRP demonstrates more pronounced anti-inflammatory and hemostatic effects comparing to non-activated PRP.

  • Open Access

    Reconstruction of Cranial Vault With Autologous Graft in Combination With Allogeneic Bone-Plastic Material and Platelet Lysate in Delayed Cranioplasty

    by A. A. Ofitserov, N. V. Borovkova, M. S. Makarov, N. E. Kudryashova, O. V. Leshchinskay, A. S. Mironov, A. E. Talypov, A. A. Budaev, I. N. Ponomarev

    INTRODUCTION In patients with cranial vault defects autologous cranioplasty with the bone flap is often accompanied by flap lysis. Bio-conductive factors, including additional biological structures and drugs, can be used to stimulate osteogenesis and integration of the bone flap.THE AIM OF THE STUDY To evaluate the safety of using a modified autologous cranial graft combined with bone-plastic material (BPM) and autologous platelets´ preparations, as well as the dynamics of cranial vault reconstruction in patients with delayed cranioplasty.MATERIAL AND METHODS 7 patients, aged from 32 to 69 years, with diagnoses involving delayed cranioplasty were examined and treated. To increase the bioconductive properties, the bone flap was perforated, saturated with 0,8% allogeneic solution of human type 1 collagen, lyophilized, sterilized with ionizing radiation and stored at 20–22°C. The diastasis region was filled with allogeneic BPM, consisted of 0,8% human type 1 collagen and bone chips. Autologous platelet lysate was used to stimulate the revitalization of the cranial graft. The assessment of reparative processes was performed by multispiral computed tomography (CT) and three-phase osteoscintigraphy after 6, 12 and 18–24 months.RESULTS In all the patients, the postoperative period was uneventful. Edges of the bone flap maintained their stability during all time of observation. In 6 of 7 patients the appearance of bone bridges was observed after 6 months, which led to formation of consolidation sites within 12–24 months. The X-ray density of the bone flap decreased slightly after 12 months without pronounced signs of flap lysis. In the postoperative period, steady decrease in the size of diastasis was noted from 2,0 (2,0; 3,1) mm to 0,9 (0,8; 1,5) mm after 18–24 months. Three-phase scintigraphy showed intensification of blood flow in the bone flap after 6–12 months, which was normalized by 12–24 months. Thus, active repair and regeneration of bone tissue in the area of diastasis began after 6–12 months and lasted for 18–24 months, followed by stabilization of the bone flap.CONCLUSION The use of autologous cranial graft in combination with allogeneic bone-plastic material and platelet preparations was safe for delayed cranioplasty. Within 24 months after surgery, high preservation of the bone flap is observed, followed by gradual regeneration and consolidation of the bone in the diastasis area, which could be observed by CT and three-phase scintigraphy.


  • Open Access

    The efficacy of using the allogeneic osteoplastic material in skull trepanation

    by A. A. Ofitserov, Н. В. Боровкова, A. E. Talypov, O. V. Leshchinskaya, N. E. Kudryashova, A. S. Mironov, M. S. Makarov, I. N. Ponomarev, A. S. Kozhanov, A. A. Budaev

    Introduction. When performing osteoplastic craniotomy, there is a need to fill the diastasis between the skull bone and the explanted bone fragment. Grafts based on allogeneic bone chips and collagen (bone-plastic material) may be very effective for cranial bone repair in diastasis area.Aim. To evaluate the safety and clinical efficacy of osteoplastic material during the osteoplastic craniotomy.Material and methods. A retrospective and prospective clinical study was conducted at the N.V. Sklifosovsky Research Institute for Emergency Medicine and included 12 patients treated in Urgent Neurosurgery Department with diagnoses suggesting the need for craniotomy. Allogenic osteoplastic material was obtained from a 0.7-0.9% solution of type I collagen and spongy bone chips with a fraction size of 315-630 microns. Osteoplastic material grafts were used intraoperatively at the cranioplastic stage of the operation after the main stages had been completed. The efficacy and safety of the use of osteoplastic material were evaluated clinically and radiologically in the early postoperative period.Results. In the early postoperative period, the study patients had no pyo-septic complications, severe pain or soft tissue swelling. All patients were discharged from the hospital in satisfactory condition to be followed-up by the physician or neurologist at the out-patient facility. The computed tomography performed in the early postoperative period visualized the diastasis lines along the bone flap line in the comparison group patients (without osteoplastic material); and in the main group, the osteoplastic material was clearly visualized. At computed tomography of the skull performed after 6–9 months and after 2–18 months, the signs of bone tissue consolidation were visualized in the patients of the main group. The radiodensity of the autologous bone flap in both groups did not significantly change at any periods. In the diastasis area, the radiodensity of diastasis in the main group was significantly higher than in the comparison group. After 1-1.15 years the radiodensity values in the diastasis area increased by average of 1.95 times (pConclusions. In patients with intraoperative cranioplasty osteoplastic material grafts did not cause complications in the early and late postoperative period. Intraoperative cranioplasty performed with using osteoplastic allogeneic material caused no complications in either early or late postoperative periods. The presence of osteoplastic material contributed to the consolidation of the autologous bone flap and healthy bone.

  • Open Access

    Comparative analysis of the integration of autologous and allogeneic cryopreserved tendons in the femoral canal on a model of laboratory animals

    by A. A. Budaev, N. S. Tropskaya, N. V. Borovkova, A. M. Fayn, G. P. Titova, M. S. Makarov, A. Yu. Vaza, I. V. Ponomarev, E. A. Kislyakova, O. S. Kislitsyna, et al.

    Allogeneic tendon grafts are seriously demand in knee joint plastic surgery. The novel method of tendon cryopreservation, including sterilization with supercritical carbon dioxide, was developed in N.V. Sklifosovsky Research Institute for Emergency Cryopreserved tendons retain their normal fiber structure without significant loss of mechanical properties. At the next stage it was necessary to evaluate cryopreserved tendons′ integration inside bone canal in experimental animals.The aim of study. To evaluate morphologic changes of autologous and allogeneic tendons inside the femur in rats and to determine the effect of tendon transplantation on the physical activity.Material and methods. The study was conducted on white inbreed male rats. Three groups of animals were formed: the control group (animals without tendon transplantation), the 1st experimental group – animals with autologous tendon transplantation, the 2nd experimental group – animals with allogeneic tendon transplantation. In animals of the experimental groups the through channel was formed in the distal metaepiphysis of the femur and a tail tendon graft 0.5 x 0.1 cm was placed there. To assess the physical activity of the animals, we studied maximum distance that the animals could run 3 and 6 weeks after transplantation was determined, using treadmill test. The graft structure was evaluated on histological preparations in transmitted light, stained with hematoxylin-eosin and Van Gieson′s stain. To assess the preservation of collagen fibers we checked the autofluorescence intensity of collagen.Results. According to the treadmill test, the distance run by the animals of both experimental groups did not significantly differ from the values in the control group. Histological analysis after 3 weeks in both experimental groups revealed signs of fibers′ decomposition in the absence of inflammatory infiltration and maintaining close contact with bone trabeculae. The autofluorescence intensity of the collagen fibers in grafts corresponded to normal or was close to normal. After 6 weeks, the animals of both experimental groups revealed areas of graft fusion with their own bone, Sharpe fibers were actively formed. In both groups, numerous small vessels with diameters up to 10 microns were detected in the area of tendon-bone contact. Infiltration of grafts by inflammatory cells was absent or very insignificant, active migration of fibroblasts to the tendon area was also not observed. In both groups, tendon grafts had areas where fiber decompactization was observed. In the area of contact with the bone, the autofluorescence of tendon fibers was sharply increased, which indicates the chemical cleavage of collagen. At 3 and 6 weeks after transplantation the effect of fixation (integration) of the tendon with bone tissue was observed in both experimental groups.Conclusions. Allogeneic tendon grafts did not cause a pronounced inflammatory or immune reaction in experimental animals. 6 weeks after transplantation of autologous and allogeneic tendons, the integration of grafts inside the femoral canal was observed. Cryopreserved allogeneic tendons were able to integrate into the body's own tissues without pronounced structural and functional disorders. According to the treadmill test, the distance covered by the animals of both experimental groups did not differ statistically significantly from the values in the control group (without tendon transplantation) after 3 and 6 weeks

  • Open Access

    Evaluation of the effectiveness of allogeneic tendon graft sterilization with supercritical carbon dioxide

    by A. A. Budaev, N. V. Borovkova, A. M. Fayn, A. Yu. Nikolaev, M. S. Makarov, M. V. Storozheva, K. I. Skuratovskaya, A. Yu. Vaza, I. V. Fomicheva, T. V. Chernen'KAya, et al.

    Structural and functional properties of the human tendon tissue complicate process of tendon-based grafts preserving. In the process of preservation, it is necessary to maintain mechanical and functional parameters of the tendon tissue as well as to provide sterility and biological safety of the graft. One could conclude effectiveness of techniques, combining tendon conservation at low temperatures and sterilization with the supercritical carbon dioxide.Aim of work: to find optimal conditions for allogeneic tendon grafts sterilization with supercritical carbon dioxide.Materials and methods. Allogeneic tendons were prepared from the tissue donors, following the rules of asepsis and antisepsis. After quarantine and confirmation of the absence of blood-borne infections the tendon grafts were divided into 3 groups: in the control group the tendons were not subjected to cryopreservation and sterilization procedures; in 2 experimental groups tendons were treated with a cryoprotector 10 % dimethyl sulfoxide (DMSO) solution and sterilized with supercritical carbon dioxide with slow gas discharge (group 2) or with fast gas discharge (group 3); the duration of sterilization in both groups varied from 1 to 12 hours. The toxicity of the grafts was assessed in human mesenchymal multipotent stromal cells (MMSC) culture on the 3rd and 7th days. The sterility of the grafts was confirmed on the 7th and 14th day by bacteriological culture on thioglycol medium and Saburo broth. Mechanical tests were performed on testing machine LLOYD Instruments LR5K Plus with the tensile speed 5 mm/min.Results. Histological analysis showed, that in the group with slow gas discharge collagen fibers retained their integrity and topography and contained only local minor tears; in all terms of treatment, the tendon grafts were sterile and nontoxic. On the contrary, in the group with fast gas discharge there was marked damage of the collagen fibers and growth of bacterial and fungal flora was observed in the culture. The grafts of the control group and the group, where sterilization with supercritical carbon dioxide was performed with slow gas discharge for 1-12 hours, were used to evaluate mechanical characteristics. In the preserved tendons the stiffness and ultimate strain did not significantly differ from the similar values in the control (p > 0.05), on the contrary, the level of ultimate strain in all experimental specimens was significantly reduced by 1.5-2.1 times comparing to the control. Young's modulus and load at rupture in the control grafts and grafts, sterilized for 1 hour, had similar values, whereas in grafts, sterilized from 3 to 12 hours, these parameters were 1.4-2.1 times lower (p < 0.05).Conclusions. The suggested technique of tendon preservation, using cryoprotector DMSO and sterilization with the supercritical carbon dioxide, allows to obtain sterile and non-toxic grafts. The structure of cells and fibers of the preserved tendons did not significantly disturbed. For supercritical carbon dioxide sterilization of tendon grafts the most optimal processing time is 1 hour.


  • Reconstruction of the anterior cruciate ligament with cryopreserved allogeneous anterior tibia tendon graft

    by A.A. Budaev, V.B. Bondarev, N.V. Borovkova, A.M. Fine, M.S. Makarov, A.YU. Vaza, O.L. Evdokimova, M.V. Neznanova, M.V. Storozheva, A.S. Mironov, et al.

    Aim of study. To evaluate the effectiveness of allogeneic tendon, sterilized with supercritical carbon dioxide, in restoration of the anterior cruciate ligament (ACL) during clinical example. Material and methods. The patient was admitted at the N.V. Sklifosovsky Research Institute for Emergency Medicine with the diagnosis: an old rupture of the anterior cruciate ligament of the right knee joint, rupture of the internal meniscus, chondromalacia of the inner condyle of the right femur 2-3 art., according to the ICRS classification. From the anamnesis, it became known about the previous 2 operations for ruptures of the ligaments of the right knee joint and the use of autologous tendons as a plastic material. A conversation was held with the patient about all possible methods of ACL repair and a choice was made in favor of using a cryopreserved allogeneic tibialis anterior tendon graft as a graft due to a shortage of autologous tissues. Allogeneic tendons were taken from tissue donors, treated with 10% dimethyl sulfoxide, sterilized with supercritical carbon dioxide and frozen at -80°C. After confirming the absence of toxicity, as well as the results of bacteriological examination, the allogeneic tendon graft was used for ACL repair. Results. The early postoperative period was uneventful. On the 12th day postoperative wounds healed by primary intention. An MRI examination revealed a graft of the anterior cruciate ligament in the formed bone canals; the graft was not thickened and had a homogeneous structure. After 28 days, the patient gradually began active and passive development of movements in the knee joint. After 6 weeks the range of motion and strength in the right knee joint was comparable to the left knee joint. After 4 months, according to magnetic resonance imaging, ligamentation of the allogenic graft and "synovial sleeve" formation were observed. Conclusion. According to the clinical course and time of rehabilitation, the technique of using allogeneic tendons during ACL plastic surgery was comparable to the use of an autologous graft. The clinical experience of using allogeneic tendons at the early postoperative stage could be assessed as successful. Further observation is necessary to fully assess the reconstruction and integration of the tendon. Keywords: anterior cruciate ligament, arthroscopic repair, graft, tendons, allogeneic, sterilization.

  • Open Access

    Selection of an optimal cryoprotectant for long-term storage of human tendon allografts

    by A. A. Budaev, N. V. Borovkova, A. M. Fayn, M. S. Makarov, M. V. Storozheva, Yu. V. Andreev, A. S. Mironov

    Introduction. Tendon grafts are widely demanded in reconstructive plastic surgery. Allogeneic tendons potentially have a number of advantages. However, the method of long-term storage of allogeneic tendons has not been optimized to date.Aim. Selection of an optimal cryoprotectant for the storage of human tendon allografts at ultra-low temperatures, which allows preserving the native tissue structure.Material and methods. We studied M. tibialis anterior tendon grafts taken from tissue donors. Endocellular/penetrating cryoprotectants (dimethyl sulfoxide, polyethylene glycol-400, glycerol) and exocellular/non-penetrating cryoprotectants (glucose solution, albumin solution) were used in the cryopreservation process. Tendon mechanical properties were evaluated using rupture and stretching-shear test, the general morphology of tendons, topography, dense and integrity of collagen fibers, preservation of cellular elements were microscopically evaluated.Results. Histological analysis showed that the safety of collagen and elastin fibers differed depending on the cryoprotectant used. At the same time, micro-fractures of collagen fibers were microscopically detected in all the experiments. In the presence of dimethyl sulfoxide, polyethylene glycol-400 and their combination the structure of collagen fibers and cells did not undergo visible changes compared to the control, whereas in all the experiments with non-penetrating cryoprotectants the topography and orientation of the fibers were clearly disturbed, deformation of many cells in the tendons was also observed.Conclusions. Cryoprotectants based on dimethyl sulfoxide, polyethylene glycol and their combinations allowed us to preserve the structural integrity of allogeneic tendons. Non-penetrating cryoprotectants did not effectively preserve the integrity of collagen fibers and cells in the tendons and cannot be recommended for cryopreservation.


  • Open Access

    Materials used for knee ligament grafting

    by A. A. Budaev, M. S. Makarov, V. V. Slastinin, N. V. Borovkova

    The authors have presented the review of scientific literature on producing grafts intended for surgical reconstruction of ligament ruptures. The treatment of ligament ruptures in reconstructive plastic surgery could be performed by using synthetic grafts, autologous and allogenic grafts from tissue donors. Advantages of synthetic grafts include the possibility of their regular manufacturing under sterile conditions, and providing mechanical properties, high biocompatibility. However, synthetic implants significantly increase the risk of synovitis and other complications, they can not be replaced by the native tissue, and have no ability to regeneration. Autologous grafts have ideal tissue compatibility and quick biointegration, could be harvested from different anatomical sites, but commonly the graft harvesting is followed by donor site morbidity and potential risk of injury nerves, elongates operation time, bad cosmetic results. The use of autografts may be also limited by anatomical features of the patient. Allogenic ligament biomaterial could provide wide range of grafts, but in our days there is no standardized methods for ligament graft sterilization and long storage. Wellknown sterilization methods, such as ionized radiation and chemical treatment, gave controversial results. One could conclude that estimation of ligament graft viability must include a complex study of biomechanical properties, cell and fibers integrity.