Daria Sharova
Daria Sharova has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Anton Vyacheslavovich Vladzymyrskyy
Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department, 127051 Moscow, Russia
9 shared publications - Dmitry Sergeevich Semenov
Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department, Moscow, Russia
7 shared publications - Yuri Aleksandrovich Vasiliev
Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department, Moscow, Russia
7 shared publications - Alexey Vladimirovich Petraikin
Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies
6 shared publications - Aleksander V. Gusev
Federal Research Institute for Health Organization and Informatics
4 shared publications Петряйкин Алексей Владимирович
Научно-практический клинический центр диагностики и телемедицинских технологий
4 shared publications
Latest Publications
- Open Access
- 4 December 2024
- Published by ECO-Vector LLC (Publications) in Digital Diagnostics
- Vol. 5 (3) , 505-518
Experience with artificial intelligence algorithms for the diagnosis of vertebral compression fractures based on computed tomography: from testing to practical evaluation
BACKGROUND: Osteoporosis is often diagnosed at the stage with complications, i.e., low-energy fractures. Vertebral compression fractures, which are complications of osteoporosis and predictors of subsequent fractures, are often asymptomatic. Compression fractures can be found by computed tomography performed for other indications with vertebral morphometry. Approaches to using artificial intelligence algorithms designed for diagnosing vertebral compression fractures were analyzed. AIM: Testing artificial intelligence algorithms to conduct morphometric analysis of vertebrae on chest computed tomography scans and assess the possibility of their implementation in medical organizations of the Moscow Healthcare Department. MATERIALS AND METHODS: To set a clinical task for artificial intelligence algorithms, basic diagnostic requirements in the area of “vertebral compression fractures (osteoporosis)” were formulated. The testing of the artificial intelligence algorithms included the following stages: self-testing, functional and calibration testing, practical evaluation, and operation testing. The first three stages of testing were performed using previously generated datasets. At practical evaluation and operation testing, artificial intelligence algorithms analyzed the data from computed tomography performed in medical organizations. The expert group of radiologists assessed the diagnostic accuracy and functional capacity of the AI algorithms at all stages. The resulting quantitative metrics of the accuracy of artificial intelligence algorithms were compared with the required target values. RESULTS: From June 2021 to June 2022, two artificial intelligence algorithms (Nos. 1 and 2) with different methods of detecting compression fractures were tested. Both artificial intelligence algorithms successfully passed the self-testing (6 tests), functional (5 tests), and calibration (100 tests) stages. The area under the ROC curve for artificial intelligence algorithm No. 1 was 0.99 (95% CI, 0.98–1), and for artificial intelligence algorithm No. 2, it was 0.91 (95% CI, 0.85–0.96). Artificial intelligence algorithm No. 1 passed the practical evaluation stage without any significant remarks, whereas algorithm No. 2 was sent for fine-tuning. After the operation testing stage, the following accuracy metrics were obtained: the areas under the ROC curve for artificial intelligence algorithm Nos. 1 and 2 were 0.93 (95% CI, 0.89–0.96) and 0.92 (95% CI, 0.90–0.94), respectively. At all stages, both artificial intelligence algorithms demonstrated sufficient metrics for clinical validation. CONCLUSION: Artificial intelligence algorithms for the automatic diagnosis of vertebral compression fractures have been tested, demonstrating the high quality of their operation. artificial intelligence algorithms can be applied as a supplementary tool in the medical decision support system.
- 4 December 2024
- Published by ECO-Vector LLC (Publications) in Digital Diagnostics
- Vol. 5 (3) , 505-518
Open AccessExperience with artificial intelligence algorithms for the diagnosis of vertebral compression fractures based on computed tomography: from testing to practical evaluation
BACKGROUND: Osteoporosis is often diagnosed at the stage with complications, i.e., low-energy fractures. Vertebral compression fractures, which are complications of osteoporosis and predictors of subsequent fractures, are often asymptomatic. Compression fractures can be found by computed tomography performed for other indications with vertebral morphometry. Approaches to using artificial intelligence algorithms designed for diagnosing vertebral compression fractures were analyzed. AIM: Testing artificial intelligence algorithms to conduct morphometric analysis of vertebrae on chest computed tomography scans and assess the possibility of their implementation in medical organizations of the Moscow Healthcare Department. MATERIALS AND METHODS: To set a clinical task for artificial intelligence algorithms, basic diagnostic requirements in the area of “vertebral compression fractures (osteoporosis)” were formulated. The testing of the artificial intelligence algorithms included the following stages: self-testing, functional and calibration testing, practical evaluation, and operation testing. The first three stages of testing were performed using previously generated datasets. At practical evaluation and operation testing, artificial intelligence algorithms analyzed the data from computed tomography performed in medical organizations. The expert group of radiologists assessed the diagnostic accuracy and functional capacity of the AI algorithms at all stages. The resulting quantitative metrics of the accuracy of artificial intelligence algorithms were compared with the required target values. RESULTS: From June 2021 to June 2022, two artificial intelligence algorithms (Nos. 1 and 2) with different methods of detecting compression fractures were tested. Both artificial intelligence algorithms successfully passed the self-testing (6 tests), functional (5 tests), and calibration (100 tests) stages. The area under the ROC curve for artificial intelligence algorithm No. 1 was 0.99 (95% CI, 0.98–1), and for artificial intelligence algorithm No. 2, it was 0.91 (95% CI, 0.85–0.96). Artificial intelligence algorithm No. 1 passed the practical evaluation stage without any significant remarks, whereas algorithm No. 2 was sent for fine-tuning. After the operation testing stage, the following accuracy metrics were obtained: the areas under the ROC curve for artificial intelligence algorithm Nos. 1 and 2 were 0.93 (95% CI, 0.89–0.96) and 0.92 (95% CI, 0.90–0.94), respectively. At all stages, both artificial intelligence algorithms demonstrated sufficient metrics for clinical validation. CONCLUSION: Artificial intelligence algorithms for the automatic diagnosis of vertebral compression fractures have been tested, demonstrating the high quality of their operation. artificial intelligence algorithms can be applied as a supplementary tool in the medical decision support system.
- Open Access
- 11 October 2024
- Published by Baltic Medical Education Center in Diagnostic radiology and radiotherapy
- Vol. 15 (3) , 92-105
Performing magnetic resonance imaging in patients with gunshot wounds: a guide for radiologists
INTRODUCTION: The safety of magnetic resonance imaging (MRI) in patients with metallic foreign bodies is an important aspect that has been the subject of many scientific papers and guidelines. The issue of MRI in patients with implanted medical devices is well researched. However, for gunshot wounds, there are no clear guidelines for practitioners, and most recommendations are to refuse to perform the study if there is the slightest doubt about its safety.OBJECTIVE: To systematize information on the safety and quality of MRI in patients with gunshot wounds and to develop practical guidelines for radiologists.MATERIALS AND METHODS: We have analyzed and summarized the main domestic and foreign recommendations for ensuring safety during MRI, generally accepted classifications and mechanisms of gunshot wounds.RESULTS: A review of physical risk factors in MRI, their causes, and recommendations for their minimization is presented. The influence of metallic objects on the appearance of artefacts on MRI images is considered. The algorithm of decision making on the safety of MRI in a patient with a bullet or shotgun wound is given. Two clinical observations are presented to illustrate the application of this algorithm.CONCLUSION: Performing MRI in gunshot wounds is feasible but requires careful analysis of the risks and the importance of diagnostic information. Interviewing the patient in these situations is often uninformative, so radiography or CT are the methods of choice for detection of metallic foreign bodies. To minimize the risks of MRI, a scan protocol should be prepared in advance and the patient should be monitored after each pulse sequence.
- 11 October 2024
- Published by Baltic Medical Education Center in Diagnostic radiology and radiotherapy
- Vol. 15 (3) , 92-105
Open AccessPerforming magnetic resonance imaging in patients with gunshot wounds: a guide for radiologists
INTRODUCTION: The safety of magnetic resonance imaging (MRI) in patients with metallic foreign bodies is an important aspect that has been the subject of many scientific papers and guidelines. The issue of MRI in patients with implanted medical devices is well researched. However, for gunshot wounds, there are no clear guidelines for practitioners, and most recommendations are to refuse to perform the study if there is the slightest doubt about its safety.OBJECTIVE: To systematize information on the safety and quality of MRI in patients with gunshot wounds and to develop practical guidelines for radiologists.MATERIALS AND METHODS: We have analyzed and summarized the main domestic and foreign recommendations for ensuring safety during MRI, generally accepted classifications and mechanisms of gunshot wounds.RESULTS: A review of physical risk factors in MRI, their causes, and recommendations for their minimization is presented. The influence of metallic objects on the appearance of artefacts on MRI images is considered. The algorithm of decision making on the safety of MRI in a patient with a bullet or shotgun wound is given. Two clinical observations are presented to illustrate the application of this algorithm.CONCLUSION: Performing MRI in gunshot wounds is feasible but requires careful analysis of the risks and the importance of diagnostic information. Interviewing the patient in these situations is often uninformative, so radiography or CT are the methods of choice for detection of metallic foreign bodies. To minimize the risks of MRI, a scan protocol should be prepared in advance and the patient should be monitored after each pulse sequence.
- Open Access
- 20 September 2024
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 5 (2) , 269-282
Optimization of magnetic resonance imaging of the hand
BACKGROUND: Magnetic resonance imaging is one of the leading imaging modalities of the musculoskeletal system. However, when imaging the hand, major problems in magnetic resonance imaging include the lack of specialized coils and reliable fixation devices for the hand, uncomfortable patient posture, motion artifacts, and small anatomical structures in the wrist. These factors inevitably lead to incorrect interpretation. AIM: To improve the quality of magnetic resonance imaging of the hand by developing an approach to coil selection, scanning protocol, and hand positioning and fixation. MATERIALS AND METHODS: A positioning device was developed to prevent hand movements. Two types of coils were evaluated. Magnetic resonance images were evaluated comparatively, as well as by a musculoskeletal radiologist. RESULTS: А head coil is more appropriate when scanning the entire hand, for example, in rheumatic diseases. A knee coil is more appropriate when studying smaller anatomical structures (including the wrist) owing to a smaller field of view and higher resolution. Based on the obtained data, guidelines for the selection of scanning parameters, sequences, and coils for magnetic resonance imaging of the hand were formulated. To prevent motion artifacts, a special fixation device of the patient’s hand was introduced. CONCLUSION: Certain factors directly affect the qualitative magnetic resonance imaging study of the hand, such as safety protocols, scanning parameters, and hand fixation. The guidelines presented in this study and the use of the developed specialized fixation device may improve the quality of magnetic resonance imaging of the hand.
- 20 September 2024
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 5 (2) , 269-282
Open AccessOptimization of magnetic resonance imaging of the hand
BACKGROUND: Magnetic resonance imaging is one of the leading imaging modalities of the musculoskeletal system. However, when imaging the hand, major problems in magnetic resonance imaging include the lack of specialized coils and reliable fixation devices for the hand, uncomfortable patient posture, motion artifacts, and small anatomical structures in the wrist. These factors inevitably lead to incorrect interpretation. AIM: To improve the quality of magnetic resonance imaging of the hand by developing an approach to coil selection, scanning protocol, and hand positioning and fixation. MATERIALS AND METHODS: A positioning device was developed to prevent hand movements. Two types of coils were evaluated. Magnetic resonance images were evaluated comparatively, as well as by a musculoskeletal radiologist. RESULTS: А head coil is more appropriate when scanning the entire hand, for example, in rheumatic diseases. A knee coil is more appropriate when studying smaller anatomical structures (including the wrist) owing to a smaller field of view and higher resolution. Based on the obtained data, guidelines for the selection of scanning parameters, sequences, and coils for magnetic resonance imaging of the hand were formulated. To prevent motion artifacts, a special fixation device of the patient’s hand was introduced. CONCLUSION: Certain factors directly affect the qualitative magnetic resonance imaging study of the hand, such as safety protocols, scanning parameters, and hand fixation. The guidelines presented in this study and the use of the developed specialized fixation device may improve the quality of magnetic resonance imaging of the hand.
- 23 April 2024
- Published by Media Sphere Publishing Group in Russian Journal of Preventive Medicine
- Vol. 27 (5)
The impact of artificial intelligence on double reading of mammograms
Mammography is a gold standard for early diagnosis of breast tumors. Independent double-reading of mammograms by two different radiologists is recommended to use in order to provide a high quality of preventive examination and to detect additional cases of malignant neoplasms. Nevertheless, this approach increases the work load and time of mammography results receiving. OBJECTIVE To assess the impact of artificial intelligence (AI) algorithm on the duration of double reading of mammograms. MATERIAL AND METHODS The study was conducted at the Moscow Reference Centre for Radiology Diagnostics (Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies, telemedai.ru). Mammograms were reviewed and radiology reports were prepared in the Unified Radiological Information Service of the Unified Medical Information and Analytical System in Moscow. Twelve radiologists who specialize in mammogram descriptions participated in the study. Russian-made softwarewas used for automatic analysis of mammograms. Two scenarios were implemented as a part of the study: the first — double-reading by radiologists, the second — first reading by AI algorithm, second reading by radiologist. RESULTS In the first scenario, a double reading was performed for 480 mammograms, in the second one — 510 mammograms. The average duration of the double-reading for the first scenario was 34:12:18 (hh:mm:ss), for the second one — 11:28:58. Application of AI algorithm allowed to reduce the duration of double-reading by 66.4% (p<0.0001). CONCLUSION The use of artificial intelligence algorithm in analysis of preventive mammography examinations allowed to reduce the duration of double-reading and work load on radiologists.
- 23 April 2024
- Published by Media Sphere Publishing Group in Russian Journal of Preventive Medicine
- Vol. 27 (5)
The impact of artificial intelligence on double reading of mammograms
Mammography is a gold standard for early diagnosis of breast tumors. Independent double-reading of mammograms by two different radiologists is recommended to use in order to provide a high quality of preventive examination and to detect additional cases of malignant neoplasms. Nevertheless, this approach increases the work load and time of mammography results receiving. OBJECTIVE To assess the impact of artificial intelligence (AI) algorithm on the duration of double reading of mammograms. MATERIAL AND METHODS The study was conducted at the Moscow Reference Centre for Radiology Diagnostics (Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies, telemedai.ru). Mammograms were reviewed and radiology reports were prepared in the Unified Radiological Information Service of the Unified Medical Information and Analytical System in Moscow. Twelve radiologists who specialize in mammogram descriptions participated in the study. Russian-made softwarewas used for automatic analysis of mammograms. Two scenarios were implemented as a part of the study: the first — double-reading by radiologists, the second — first reading by AI algorithm, second reading by radiologist. RESULTS In the first scenario, a double reading was performed for 480 mammograms, in the second one — 510 mammograms. The average duration of the double-reading for the first scenario was 34:12:18 (hh:mm:ss), for the second one — 11:28:58. Application of AI algorithm allowed to reduce the duration of double-reading by 66.4% (p<0.0001). CONCLUSION The use of artificial intelligence algorithm in analysis of preventive mammography examinations allowed to reduce the duration of double-reading and work load on radiologists.
- Open Access
- 19 April 2024
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 5 (1) , 29-40
Improving aortic aneurysm detection with artificial intelligence based on chest computed tomography data
BACKGROUND: Aortic aneurysms are known as “silent killers” because this potentially fatal condition can be asymptomatic. The annual incidence of thoracic aortic aneurysms and ruptures is approximately 10 and 1.6 per 100,000 individuals, respectively. The mortality rate for ruptured aneurysms ranges from 94% to 100%. Early diagnosis and treatment can be life-saving. Artificial intelligence technologies can significantly improve diagnostic accuracy and save the lives of patients with thoracic aortic aneurysms. AIM: This study aimed to assess the efficacy of artificial intelligence technologies for detecting thoracic aortic aneurysms on chest computed tomography scans, as well as the possibility of using artificial intelligence as a clinical decision support system for radiologists during the primary interpretation of radiological images. MATERIALS AND METHODS: The results of using artificial intelligence technologies for detecting thoracic aortic aneurysms on non-contrast chest computed tomography scans were evaluated. A sample of 84,405 patients 18 years old was generated, with 86 cases of suspected thoracic aortic aneurysms based on artificial intelligence data selected and retrospectively assessed by radiologists and vascular surgeons. To assess the age distribution of the aortic diameter, an additional sample of 968 cases was randomly selected from the total number. RESULTS: In 44 cases, aneurysms were initially identified by radiologists, whereas in 31 cases, aneurysms were not detected initially; however, artificial intelligence aided in their detection. Six studies were excluded, and five studies had false-positive results. Artificial intelligence aids in detecting and highlighting aortic pathological changes in medical images, increasing the detection rate of thoracic aortic aneurysms by 41% when interpreting chest computed tomography scans. The use of artificial intelligence technologies for primary interpretations of radiological studies and retrospective assessments is advisable to prevent underdiagnosis of clinically significant pathologies and improve the detection rate of pathological aortic enlargement. In the additional sample, the incidence of thoracic aortic dilation and thoracic aortic aneurysms in adults was 14.5% and 1.2%, respectively. The findings also revealed an age-dependent diameter of the thoracic aorta in both men and women. CONCLUSION: The use of artificial intelligence technologies in the primary interpretation of chest computed tomography scans can improve the detection rate of clinically significant pathologies such as thoracic aortic aneurysms. Expanding retrospective screening based on chest computed tomography scans using artificial intelligence can improve the diagnosis of concomitant pathologies and prevent negative consequences.
- 19 April 2024
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 5 (1) , 29-40
Open AccessImproving aortic aneurysm detection with artificial intelligence based on chest computed tomography data
BACKGROUND: Aortic aneurysms are known as “silent killers” because this potentially fatal condition can be asymptomatic. The annual incidence of thoracic aortic aneurysms and ruptures is approximately 10 and 1.6 per 100,000 individuals, respectively. The mortality rate for ruptured aneurysms ranges from 94% to 100%. Early diagnosis and treatment can be life-saving. Artificial intelligence technologies can significantly improve diagnostic accuracy and save the lives of patients with thoracic aortic aneurysms. AIM: This study aimed to assess the efficacy of artificial intelligence technologies for detecting thoracic aortic aneurysms on chest computed tomography scans, as well as the possibility of using artificial intelligence as a clinical decision support system for radiologists during the primary interpretation of radiological images. MATERIALS AND METHODS: The results of using artificial intelligence technologies for detecting thoracic aortic aneurysms on non-contrast chest computed tomography scans were evaluated. A sample of 84,405 patients 18 years old was generated, with 86 cases of suspected thoracic aortic aneurysms based on artificial intelligence data selected and retrospectively assessed by radiologists and vascular surgeons. To assess the age distribution of the aortic diameter, an additional sample of 968 cases was randomly selected from the total number. RESULTS: In 44 cases, aneurysms were initially identified by radiologists, whereas in 31 cases, aneurysms were not detected initially; however, artificial intelligence aided in their detection. Six studies were excluded, and five studies had false-positive results. Artificial intelligence aids in detecting and highlighting aortic pathological changes in medical images, increasing the detection rate of thoracic aortic aneurysms by 41% when interpreting chest computed tomography scans. The use of artificial intelligence technologies for primary interpretations of radiological studies and retrospective assessments is advisable to prevent underdiagnosis of clinically significant pathologies and improve the detection rate of pathological aortic enlargement. In the additional sample, the incidence of thoracic aortic dilation and thoracic aortic aneurysms in adults was 14.5% and 1.2%, respectively. The findings also revealed an age-dependent diameter of the thoracic aorta in both men and women. CONCLUSION: The use of artificial intelligence technologies in the primary interpretation of chest computed tomography scans can improve the detection rate of clinically significant pathologies such as thoracic aortic aneurysms. Expanding retrospective screening based on chest computed tomography scans using artificial intelligence can improve the diagnosis of concomitant pathologies and prevent negative consequences.
- 1 December 2023
- Published by Vidar, Ltd. in Medical Visualization
- Vol. 28 (1) , 157-167
Radiomics of fetal magnetic resonance imaging in congenital diaphragmatic hernia
Objectives. Analysis of possibilities of radiomics as a source of additional diagnostic information about the structural maturity of the lungs Materials and methods. A retrospective study included 72 pregnant women: 35 with congenital fetal diaphragmatic hernia (group 1) and 37 without fetal lung pathology (group 2). Frontal or co-frontal T2 images (T2 FSE) were obtained. Segmentation of regions of interest at the fetal lung level was performed manually with ITK-Snap. A total of 107 radiomic features were extracted using pyradiomics. The statistical analysis was performed using the STATISTICA 10 statistical analysis package (USA) to detect correlation between trait values and the target variable (presence of lung pathology in CDH), and to show differences in the comparison groups according to the detected parameters. Results. Statistically significant features were identified for 2D and 3D segmentations (p < 0.05). For 2D and 3D segmentations, the number of significant features was 14 and 73, respectively. After exclusion of features with cross-correlations, their number decreased to 6 and 8 for single slices and 3D images, respectively. Correlation coefficients between the features and the presence of lung pathology were also calculated. In the case of 3D images, the number of features with significant correlation coefficients (r > 0.4, p < 0.05) equaled 20, while for single-slice images this number was 3. Conclusion. The data obtained allow to conclude that it is reasonable to use texture analysis of the 3D MRI images as a source of additional diagnostic information concerning the structural maturity of the lungs.
- 1 December 2023
- Published by Vidar, Ltd. in Medical Visualization
- Vol. 28 (1) , 157-167
Radiomics of fetal magnetic resonance imaging in congenital diaphragmatic hernia
Objectives. Analysis of possibilities of radiomics as a source of additional diagnostic information about the structural maturity of the lungs Materials and methods. A retrospective study included 72 pregnant women: 35 with congenital fetal diaphragmatic hernia (group 1) and 37 without fetal lung pathology (group 2). Frontal or co-frontal T2 images (T2 FSE) were obtained. Segmentation of regions of interest at the fetal lung level was performed manually with ITK-Snap. A total of 107 radiomic features were extracted using pyradiomics. The statistical analysis was performed using the STATISTICA 10 statistical analysis package (USA) to detect correlation between trait values and the target variable (presence of lung pathology in CDH), and to show differences in the comparison groups according to the detected parameters. Results. Statistically significant features were identified for 2D and 3D segmentations (p < 0.05). For 2D and 3D segmentations, the number of significant features was 14 and 73, respectively. After exclusion of features with cross-correlations, their number decreased to 6 and 8 for single slices and 3D images, respectively. Correlation coefficients between the features and the presence of lung pathology were also calculated. In the case of 3D images, the number of features with significant correlation coefficients (r > 0.4, p < 0.05) equaled 20, while for single-slice images this number was 3. Conclusion. The data obtained allow to conclude that it is reasonable to use texture analysis of the 3D MRI images as a source of additional diagnostic information concerning the structural maturity of the lungs.
- Open Access
- 26 September 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (3) , 292-305
Bone mineral density radiopaque templates for cone beam computed tomography and multidetector computed tomography
BACKGROUND: Cone beam computed tomography is widely applied for diagnostics and planning various manipulations in the maxillofacial region, for example, dental implantation. Its advantages include high spatial resolution, low radiation exposure, and cost-effectiveness. However, it has a significant drawback: the inability to determine the density of the jaw bone in Hounsfield Units (HU). AIMS: This study aimed to develop radiopaque templates with sets of X-ray density based on potassium hydrophosphate and beta-tricalcium phosphate, to study templates on various cone beam computed tomography and multidetector computed tomography devices, and to determine a cross-calibration algorithm for assessing the bone mineral density of the jaw in HU. MATERIALS AND METHODS: The bone mineral density template comprised microtubes (0.25 ml) with potassium hydrophosphate concentrations of 49.96, 99.98, 174.99, 349.99, and 549.98 mg/ml, and a suspension of beta-tricalcium phosphate with an equivalent concentration of potassium hydrophosphate 1,506 mg/ml, designed to simulate the types of bone density according to C. Mish. The study was carried out on two multidetector computed tomography and four cone beam computed tomography machines. Cross-calibration was referred on the standard multidetector computed tomography 1 mode 120 kV, 200 mA. RESULTS: There was a significant scatter of the X-ray values (HU for multidetector computed tomography and GV for cone beam computed tomography) vs. bone mineral density, with varying slopes, bias, and curve shapes. After cross-calibration, good comparability corresponding to the multidetector computed tomography 1 mode was shown. The median of the differences before cross-calibration was 160 relative units (HU, GV), after decreased by 10 times and amounted to 16 rel. units (p=0.000). The mean difference for cone beam computed tomography was significantly higher (30 rel. units) than for multidetector computed tomography (8 rel. units) (p=0.024, MannWhitney U test). CONCLUSION: The developed radiopaque template enables the standardization of densitometric indicators for cone beam computed tomography and various multidetector computed tomography modes. On average, the spread after cross-calibration is reduced by 10 times, which makes it possible to classify bone tissue in HU according to C. Mish.
- 26 September 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (3) , 292-305
Open AccessBone mineral density radiopaque templates for cone beam computed tomography and multidetector computed tomography
BACKGROUND: Cone beam computed tomography is widely applied for diagnostics and planning various manipulations in the maxillofacial region, for example, dental implantation. Its advantages include high spatial resolution, low radiation exposure, and cost-effectiveness. However, it has a significant drawback: the inability to determine the density of the jaw bone in Hounsfield Units (HU). AIMS: This study aimed to develop radiopaque templates with sets of X-ray density based on potassium hydrophosphate and beta-tricalcium phosphate, to study templates on various cone beam computed tomography and multidetector computed tomography devices, and to determine a cross-calibration algorithm for assessing the bone mineral density of the jaw in HU. MATERIALS AND METHODS: The bone mineral density template comprised microtubes (0.25 ml) with potassium hydrophosphate concentrations of 49.96, 99.98, 174.99, 349.99, and 549.98 mg/ml, and a suspension of beta-tricalcium phosphate with an equivalent concentration of potassium hydrophosphate 1,506 mg/ml, designed to simulate the types of bone density according to C. Mish. The study was carried out on two multidetector computed tomography and four cone beam computed tomography machines. Cross-calibration was referred on the standard multidetector computed tomography 1 mode 120 kV, 200 mA. RESULTS: There was a significant scatter of the X-ray values (HU for multidetector computed tomography and GV for cone beam computed tomography) vs. bone mineral density, with varying slopes, bias, and curve shapes. After cross-calibration, good comparability corresponding to the multidetector computed tomography 1 mode was shown. The median of the differences before cross-calibration was 160 relative units (HU, GV), after decreased by 10 times and amounted to 16 rel. units (p=0.000). The mean difference for cone beam computed tomography was significantly higher (30 rel. units) than for multidetector computed tomography (8 rel. units) (p=0.024, MannWhitney U test). CONCLUSION: The developed radiopaque template enables the standardization of densitometric indicators for cone beam computed tomography and various multidetector computed tomography modes. On average, the spread after cross-calibration is reduced by 10 times, which makes it possible to classify bone tissue in HU according to C. Mish.
- Open Access
- 26 September 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (3) , 439-447
Quality management system: A tool for the development of the organization or an additional burden?
A quality management system constitutes one of the organizations management systems that provides for the selection of a set of processes in the organizations activities designed to ensure the stable quality of products and services provided. The growth of global industrial production has underscored the need for the creation of such production and management systems. These systems are designed to ensure that enterprises remains prepared to meet the constantly changing consumer value of manufactured products in accordance with consumer requirements, as well as the satisfaction of consumers themselves. As a result, attention began to focus on the production processes implemented within the organization when creating products. Regarding the production of medical devices, a quality management system can be defined as an organizational structure encompassing its functions, procedures, processes, and resources necessary for the coordinated direction and management of a manufacturing organization with respect to the quality of medical products. The article reflects the principles of the quality management system and management processes. Noteworthy emphasis is placed on the features of quality management systems for medical devices, including the features of the quality management system for software that is a medical device. Furthermore, the conditions under which the quality management system becomes a tool for ensuring the sustainable development of the organization are noted.
- 26 September 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (3) , 439-447
Open AccessQuality management system: A tool for the development of the organization or an additional burden?
A quality management system constitutes one of the organizations management systems that provides for the selection of a set of processes in the organizations activities designed to ensure the stable quality of products and services provided. The growth of global industrial production has underscored the need for the creation of such production and management systems. These systems are designed to ensure that enterprises remains prepared to meet the constantly changing consumer value of manufactured products in accordance with consumer requirements, as well as the satisfaction of consumers themselves. As a result, attention began to focus on the production processes implemented within the organization when creating products. Regarding the production of medical devices, a quality management system can be defined as an organizational structure encompassing its functions, procedures, processes, and resources necessary for the coordinated direction and management of a manufacturing organization with respect to the quality of medical products. The article reflects the principles of the quality management system and management processes. Noteworthy emphasis is placed on the features of quality management systems for medical devices, including the features of the quality management system for software that is a medical device. Furthermore, the conditions under which the quality management system becomes a tool for ensuring the sustainable development of the organization are noted.
- Open Access
- 26 June 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (1S) , 76-78
Comparison of the duration of generating radiological protocols with keyboard and voice input
BACKGROUND: Speech recognition is becoming increasingly common in the national healthcare system. One of the first specialties to implement this technology on a large scale was radiology. However, the efficiency of voice input and its effect on the length of time required to complete medical records remain unresolved. AIM: To assess the efficiency of speech recognition in generating radiological protocols of different modalities and types. METHODS: The retrospective study was conducted at the Moscow Reference Center of the Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Department of Health. A total of 12,912 radiological reports on fluorography, mammography, chest computed tomography (CT), contrast-enhanced magnetic resonance imaging (MRI) of the brain, and contrast-enhanced CT of the abdomen and pelvis were included in the study by simple random sampling. The size of all samples exceeded 766 reports, calculated with regard to the size of the general population of over 100,000 reports. The Voice2Med software was used to fill in the radiological protocols. Intergroup comparison was performed using the MannWhitney U-test with a statistical significance level of 0.05. RESULTS: The average duration of generating fluorographic protocols in the keyboard and voice input groups was 189.9 s (0:03:09) and 236.2 s (0:03:56), respectively (p 0.0001). For mammographic reports, the duration was 387.1 s (0:06:27) and 444.8 s (0:07:24), respectively (p 0.0001). For radiographic reports, it amounted to 247.8 s (0:04:07) and 189.0 s (0: 03:09), respectively (p 0.0001), and for chest CT, it was 379.7 s (0:06:19) and 382.7 s (0:06:22), respectively (p=0.12). For MRI of the brain, the protocols were generated for 709.9 s (0:11:49) and 559.9 s (0: 09:19), respectively (p 0.0001), and for contrast-enhanced chest, abdominal, and pelvic CT scans, it took 2714.6 s (0:45:15) and 1778.4 s (0:29:38), respectively. Voice input slowed down the preparation time of mammographic and fluorographic protocols. This is due to the use of a structured electronic medical document in medical facilities to describe the results of the examinations. Speech recognition showed the greatest efficiency in generating MRI and CT protocols. Such reports contain a large number of pathological changes, both target and incidental findings, which requires a detailed description by the radiologist in the examination protocol. CONCLUSIONS: Speech recognition in generating radiological protocols showed different efficiency depending on the modality and type of the radiological protocol filled in using the voice input system. This approach is optimal for describing CT and MRI scans.
- 26 June 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (1S) , 76-78
Open AccessComparison of the duration of generating radiological protocols with keyboard and voice input
BACKGROUND: Speech recognition is becoming increasingly common in the national healthcare system. One of the first specialties to implement this technology on a large scale was radiology. However, the efficiency of voice input and its effect on the length of time required to complete medical records remain unresolved. AIM: To assess the efficiency of speech recognition in generating radiological protocols of different modalities and types. METHODS: The retrospective study was conducted at the Moscow Reference Center of the Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Department of Health. A total of 12,912 radiological reports on fluorography, mammography, chest computed tomography (CT), contrast-enhanced magnetic resonance imaging (MRI) of the brain, and contrast-enhanced CT of the abdomen and pelvis were included in the study by simple random sampling. The size of all samples exceeded 766 reports, calculated with regard to the size of the general population of over 100,000 reports. The Voice2Med software was used to fill in the radiological protocols. Intergroup comparison was performed using the MannWhitney U-test with a statistical significance level of 0.05. RESULTS: The average duration of generating fluorographic protocols in the keyboard and voice input groups was 189.9 s (0:03:09) and 236.2 s (0:03:56), respectively (p 0.0001). For mammographic reports, the duration was 387.1 s (0:06:27) and 444.8 s (0:07:24), respectively (p 0.0001). For radiographic reports, it amounted to 247.8 s (0:04:07) and 189.0 s (0: 03:09), respectively (p 0.0001), and for chest CT, it was 379.7 s (0:06:19) and 382.7 s (0:06:22), respectively (p=0.12). For MRI of the brain, the protocols were generated for 709.9 s (0:11:49) and 559.9 s (0: 09:19), respectively (p 0.0001), and for contrast-enhanced chest, abdominal, and pelvic CT scans, it took 2714.6 s (0:45:15) and 1778.4 s (0:29:38), respectively. Voice input slowed down the preparation time of mammographic and fluorographic protocols. This is due to the use of a structured electronic medical document in medical facilities to describe the results of the examinations. Speech recognition showed the greatest efficiency in generating MRI and CT protocols. Such reports contain a large number of pathological changes, both target and incidental findings, which requires a detailed description by the radiologist in the examination protocol. CONCLUSIONS: Speech recognition in generating radiological protocols showed different efficiency depending on the modality and type of the radiological protocol filled in using the voice input system. This approach is optimal for describing CT and MRI scans.
- Open Access
- 26 June 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (1S) , 93-95
Artificial intelligence ethics code in healthcare. Sustainability of artificial intelligence systems: Why do we talk about their impact on the environment?
Environmental problems have a tremendous impact on the entire world population, particularly on human health, which plays a leading role in individual well-being. Environmental pollution, according to some estimates, kills approximately 9 million people every year. The introduction of artificial intelligence (AI) systems in many areas has enormous potential in reducing human impact on the environment; however, such systems have negative effects. The potential of AI systems to improve healthcare is inextricably linked to the ethical challenges posed by the complexity of these systems and their impact on the lives and health of communities, patients, and staff. In addition to aspects that relate directly to the algorithms, data, and clinical application of AI systems, long-term risks exist that are not obvious at first glance. One of these risks is the negative impact of AI systems on the environment, which may harm human health indirectly. AI systems are more than software, having physical components that are necessary for their functioning, such as processors, memory, and sensors. The manufacture and the energy consumption of the components has a profound effect on the environment. One study showed that when a single AI algorithm is trained, carbon emissions may reach values corresponding to the total carbon emissions from five cars lifetime. This study analyzes existing literature linking the development of AI systems, especially in healthcare, to their effects on the environment. The study is intended to complement the emerging AI Ethics Code for healthcare, specifically the principles of sustainability that will be included in this code. The study concludes that the environmental impact of AI systems should be considered when formulating ethical standards for AI in healthcare. These standards must be considered during the development, testing, and application phases of AI systems. All the people involved in the creation and use of AI systems (developers, physicians, and regulators) must monitor the environmental impact and minimize the environmental consequences of such systems at all stages of their existence. This principle calls for minimizing negative impacts, improving the energy efficiency, and disposing physical components in strict compliance with current legislation. Moreover, the rapid development of AI systems and the ethical dilemmas require that solutions be proposed jointly and ethical standards be developed in a manner that is consistent and sensitive to emerging technologies.
- 26 June 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (1S) , 93-95
Open AccessArtificial intelligence ethics code in healthcare. Sustainability of artificial intelligence systems: Why do we talk about their impact on the environment?
Environmental problems have a tremendous impact on the entire world population, particularly on human health, which plays a leading role in individual well-being. Environmental pollution, according to some estimates, kills approximately 9 million people every year. The introduction of artificial intelligence (AI) systems in many areas has enormous potential in reducing human impact on the environment; however, such systems have negative effects. The potential of AI systems to improve healthcare is inextricably linked to the ethical challenges posed by the complexity of these systems and their impact on the lives and health of communities, patients, and staff. In addition to aspects that relate directly to the algorithms, data, and clinical application of AI systems, long-term risks exist that are not obvious at first glance. One of these risks is the negative impact of AI systems on the environment, which may harm human health indirectly. AI systems are more than software, having physical components that are necessary for their functioning, such as processors, memory, and sensors. The manufacture and the energy consumption of the components has a profound effect on the environment. One study showed that when a single AI algorithm is trained, carbon emissions may reach values corresponding to the total carbon emissions from five cars lifetime. This study analyzes existing literature linking the development of AI systems, especially in healthcare, to their effects on the environment. The study is intended to complement the emerging AI Ethics Code for healthcare, specifically the principles of sustainability that will be included in this code. The study concludes that the environmental impact of AI systems should be considered when formulating ethical standards for AI in healthcare. These standards must be considered during the development, testing, and application phases of AI systems. All the people involved in the creation and use of AI systems (developers, physicians, and regulators) must monitor the environmental impact and minimize the environmental consequences of such systems at all stages of their existence. This principle calls for minimizing negative impacts, improving the energy efficiency, and disposing physical components in strict compliance with current legislation. Moreover, the rapid development of AI systems and the ethical dilemmas require that solutions be proposed jointly and ethical standards be developed in a manner that is consistent and sensitive to emerging technologies.