DCDiego Celdran-Bonafonte

Diego Celdran-Bonafonte

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Diego Celdran-Bonafonte has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Computational and Experimental Evaluation of a Flow-Conditioning Anastomotic Device for Arteriovenous Fistula Maturation

    by Keith Saum, Begoña Campos, Diego Celdran Bonafonte, Liran Oren, Albert Phillip Owens, Prabir Roy-Chaudhury

    The arteriovenous fistula (AVF) is the preferred method of vascular access for hemodialysis; however, 30–50% of AVFs undergo primary maturation failure and are unsuitable for clinical use. As disturbed hemodynamics initiate endothelial injury and intimal hyperplasia, we designed an endovascular flow-conditioning anastomotic device (FCAD) to directly improve AVF hemodynamics and protect the anastomotic region. Using computational fluid dynamics, we characterized the flow field and wall shear stress (WSS) profiles in idealized AVF models with and without the FCAD. Incorporation of the FCAD into a brachiocephalic AVF model reduced regions of oscillatory WSS and generated a symmetrical flow profile in the draining vein compared to a reference AVF. Parametric studies identified an FCAD geometry with a tab angle, height, and aspect ratio of 30°, 0.1 diameters, and 1.0 that increased time-averaged WSS along the inner venous wall and achieved a physiological WSS (1–3 Pa) without inducing regions of oscillatory flow throughout the cardiac cycle. Similar findings were observed with an in vitro model using particle image velocimetry. This study demonstrates the feasibility of the FCAD to normalize venous flow and WSS while imposing minimal resistance to blood flow. Restoring physiological WSS levels on the venous wall may help preserve endothelial function and improve AVF maturation.

  • From exposure to evidence: The present and future of rodent surgical training in laboratory animal science

    by Diego Celdran-Bonafonte, Petra Seebeck

    Surgical training remains one of the most consequential yet historically underexamined components of laboratory animal science (LAS). While advances in anesthesia, analgesia, asepsis, and oversight have improved welfare and scientific rigor, training has often relied on decentralized apprenticeship models with variable structure and assessment, sometimes leaving foundational surgical standards such as aseptic workflow, sterile gowning, and gloving insufficiently formalized. As regulatory expectations, societal scrutiny, and research complexity have increased, the limitations of exposure-based training have become more apparent. This perspective examines the evolution of rodent surgical training in LAS, highlighting both the strengths of the modern training ecosystem and persistent gaps in standardization, access, and competency assessment. Emerging simulation technologies, including 3D-printed and hybrid models, offer scalable opportunities to reduce training-related animal use, shorten learning curves, and introduce objective performance benchmarks before live procedures. Evidence from surgical education and experimental microsurgery supports a hybrid, competency-based approach in which simulation prepares trainees for supervised live animal work rather than replacing it. Looking ahead, coordinated validation frameworks, shared assessment tools, and institutional commitment will be essential to transition toward a structured, data-driven, and ethically aligned post-apprenticeship model of laboratory animal surgical training.

  • Design and Validation of an Arduino-Based, Cost-Effective Heated Anesthesia Induction Chamber for Mice

    by Anthony Corea, Kyle Tucker, Colin E Benites, Christopher Arellano, Diego Celdran-Bonafonte

    Rodents are highly susceptible to peri-anesthetic hypothermia because of their small body size, large surface area to volume/mass ratio, and anesthetic-induced thermoregulatory depression. Early heat loss during induction is rapid and can be difficult to reverse, emphasizing the need for simple, reliable warming solutions during anesthetic induction. We designed and validated a low-cost, Arduino-controlled heated induction chamber for mice and evaluated its safety and efficacy in preventing early hypothermia. The device uses proportional integral derivative control to regulate a heated chamber floor. Bench testing quantified warm-up time, steady-state stability, and the temperature offset between the embedded thermistor and surface temperature. In a randomized, paired, repeated-measures design, 10 adult C57BL/6 mice underwent 2 experimental conditions, unheated induction compared with heated induction, followed by a standardized 10-minute anesthetic maintenance phase on a prewarmed, heated surgical monitoring platform. Core body temperature was measured with intraperitoneal radio frequency identification transponders, while rectal temperature and physiologic parameters (peripheral oxygen saturation, heart rate, respiratory rate) were recorded during maintenance. Recovery time was measured from isoflurane discontinuation until the first voluntary movement. The heated chamber reached thermal stability within 10 minutes; at steady state, a constant average surface temperature near 37.5 °C was reliably obtained. During induction, unheated controls showed a rapid decline in core temperature, while during the heated-chamber induction, they maintained normothermia. The control group did not regain baseline temperature until several minutes into the maintenance phase and stabilized at values ∼1 °C lower than those of the heated group. Both groups remained physiologically stable during anesthetic maintenance and recovered within comparable times. This cost-effective, Arduino-based chamber prevented early hypothermia without compromising physiologic stability and represents a practical refinement to improve rodent anesthetic procedures, animal welfare, and experimental reproducibility.

  • Open Access

    Computational and Experimental Evaluation of a Flow-Conditioning Anastomotic Device for Arteriovenous Fistula Maturation

    by Keith L Saum, Begona Campos, Diego Celdran-Bonafonte, Liran Oren, Albert Phillip Owens, Prabir Roy-Chaudhury

    The arteriovenous fistula (AVF) is the preferred method of vascular access for hemodialysis; however, 30-50% of AVFs undergo primary failure and are unsuitable for clinical use. As disturbed hemodynamics initiate endothelial injury and intimal hyperplasia, we designed an endovascular flow-conditioning anastomotic device (FCAD) to directly improve AVF hemodynamics and protect the anastomotic region. Using computational fluid dynamics, we characterized the flow field and wall shear stress (WSS) profiles in idealized AVF models with and without the FCAD. Incorporation of the FCAD into a brachiocephalic AVF model reduced regions of oscillatory WSS and generated a symmetrical flow profile in the draining vein compared to a reference AVF. Parametric studies also identified an FCAD geometry with a tab angle of 30 degrees, a height of 0.1 diameters, and an aspect ratio of 1.0 that restored time-averaged WSS along the inner venous wall, achieving a physiological level without inducing regions of oscillatory flow throughout the cardiac cycle. Similar findings were observed with an in vitro model using particle imaging velocimetry. This study demonstrates the feasibility of the FCAD to normalize venous flow and WSS while imposing minimal resistance to blood flow. Restoring physiological WSS levels on the venous wall is expected to preserve endothelial function and improve AVF maturation.

  • A Novel 3D-Printed Mouse Model for Surgical Training: Multicenter Construct, Face, and Content Validation Study

    by Diego Celdran-Bonafonte, Felix Gantenbein, Daniel Ruiz Perez, Regina Rumpel, Nina Eva Trimmel

    Advancements in laboratory animal training increasingly incorporate technological innovations aiming to better align training standards with the 3Rs (Replacement, Reduction, and Refinement). This trend is shifting away from traditional reliance on live animals and cadavers toward simulation-based methods. This study introduces and assesses the validity of a novel 3D-printed rodent surgical simulator designed for the practice and training of basic rodent surgical skills. To evaluate its potential to partially replace animal use, refine rodent surgical training, and reduce the number of animals needed, a multicenter validation study across 5 European and US research academic centers was conducted. The study assessed the simulator’s face, content, and construct validity, involving participants inexperienced and experts in rodent surgery. The construct validity was evaluated through task completion times and blinded quality assessments across multiple training iterations. The results revealed that inexperienced participants demonstrated significant improvements in both speed and quality of surgical tasks with repeated simulator use, eventually reaching performance levels comparable to experts’ initial attempts. Expert participants consistently outperformed the inexperienced group. Face and content validity were supported by postuse surveys, with high ratings from both groups regarding the simulator’s anatomic realism and its perceived usefulness for the acquisition and development of fundamental surgical skills. Overall, the findings of this study support that this 3D-printed rodent surgical simulator offers a realistic, effective, and ethically sound alternative for basic rodent surgical skills training and competency assessment.


  • Dolichocolon (redundant colon) in a rhesus macaque (Macaca mulatta)

    by Diego Celdran‐Bonafonte, Kathryn A. O'COnnell, Katalin M. Gothard, Iman Ghaderi, David Besselsen, Cynthia J. Doane

    Dolichocolon (redundant colon) is an underdiagnosed cause of severe constipation in humans. The clinical presentation reported here in a rhesus macaque closely resembles that of intestinal adenocarcinoma, the most common neoplasia in macaques. Dolichocolon should be considered in differential diagnosis of macaques with anorexia, weight loss, and constipation.

  • Functional analysis of arteriovenous fistulae in non-contrast magnetic resonance images

    by José A. Rosado-Toro, Rohit C. Philip, Samuel Thomas Dunn, Diego Celdran-Bonafonte, Yong He, Scott A Berceli, Prabir Roy-Chaudhury, Eleonora Tubaldi


  • A pig model of tunneled dialysis catheter (TDC) infection and dysfunction: Opportunities for therapeutic innovation

    by Diego Celdran-Bonafonte, Lihua H Wang, Aous Jarrouj, Begona Campos-Naciff, Jaroslav Janda, Prabir Roy-Chaudhury

    Background: Although tunneled dialysis catheters (TDC) are far from ideal, they still represent the main form of vascular access for most patients beginning dialysis. Catheters are easy to place and allow patients instant access to dialysis, but regardless of these benefits, catheters are associated with a high incidence of significant complications like bloodstream infections, central venous stenosis, thrombosis, and dysfunction. In the present study, we aim to describe and characterize a swine model of catheter dysfunction and bloodstream infection, that recreates the clinical scenario, to help to serve as a platform to develop therapeutic innovations for this important clinical problem. Methods: Six Yorkshire cross pigs were used in this study. Non-coated commercial catheters were implanted in the external jugular recreating the main features of common clinical practice. Catheters were aseptically accessed twice a week for a mock dialysis procedure (flushing in and out) to assess for and identify catheter dysfunction. Animals were monitored daily for infections; once detected, blood samples were collected for bacterial culture and antibiograms. Study animals were euthanized when nonresponsive to treatment. Tissue samples were collected in a standardized fashion for macroscopic inspection and histological analysis. Results: The data analysis revealed an early onset of infection with a median time to infection of 9 days, 40% of the isolates were polymicrobial, and the average time to euthanasia was 20.16 ± 7.3 days. Median time to catheter dysfunction onset was 6 days post-implantation. Postmortem dissection revealed external fibrin sheath and internal thrombosis as the main causes of catheter dysfunction. There was also evidence of central venous stenosis with positive cells for αSMA, CD68, Ki67, Smoothelin, and Vimentin within the venous neointima. Conclusions: The described model represents a reliable and reproducible large animal model of catheter dysfunction and bloodstream infection, which recreates all the main complications of TDC’s and so could be used as a validated large animal model to develop new therapies for TDC related infection, thrombosis/dysfunction and central venous stenosis.