Peter Andersson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Peter Andersson has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Roumiana Chakarova
Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden
4 shared publications A. Lindberg
Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
1 shared publication- Andreas Hallqvist
Department of Oncology, Sahlgrenska University Hospital, Gothenburg, Sweden; Department of Oncology, Institute of Clinical Sciences, University of Gothenburg, Gothenburg, Sweden
1 shared publication J. Swanpalmer
Institute of Clinical Sciences, Department of Medical Radiation Science, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
1 shared publication- John Swanpalmer
Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
1 shared publication M Båth
Sahlgrenska Academy, Institute of Clinical Sciences, Department of Medical Radiation Sciences, University of Gothenburg, Gothenburg, Sweden
1 shared publication
Latest Publications
- Open Access
- 9 April 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (3) , 035013
Portal dose image prediction using Monte Carlo generated transmission energy fluence maps of dynamic radiotherapy treatment plans: a deep learning approach
Aims. This work aims to develop and investigate the feasibility of a hybrid model combining Monte Carlo (MC) simulations and deep learning (DL) to predict electronic portal imaging device (EPID) images based on MC-generated exit phase space energy fluence maps from dynamic radiotherapy treatment plans. Such predicted images can be used as reference images during in vivo dosimetry. Materials and methods. MC simulations involving a Varian True Beam linear accelerator model were performed using the EGSnrc code package. Two custom variants of the U-Net architecture were employed. The MLC dynamic chair sequence and 17 clinical treatment plans, spanning various cancer types and delivery methods, were used to acquire experimental data, and in the MC simulations. The proposed method was tested through 2D gamma index analysis, comparing predicted and measured EPID images. Results. Results showed gamma passing rates of 38.65%, 74.16% and 96.17% (minimum, median, maximum) for a simpler model variant and 52.72%, 80.61% and 96.80% for the more complex model variant. Conclusion. The study highlights the feasibility of integrating MC and DL methodologies for in vivo dosimetry quality assurance in complex radiotherapy delivery.
- 9 April 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (3) , 035013
Open AccessPortal dose image prediction using Monte Carlo generated transmission energy fluence maps of dynamic radiotherapy treatment plans: a deep learning approach
Aims. This work aims to develop and investigate the feasibility of a hybrid model combining Monte Carlo (MC) simulations and deep learning (DL) to predict electronic portal imaging device (EPID) images based on MC-generated exit phase space energy fluence maps from dynamic radiotherapy treatment plans. Such predicted images can be used as reference images during in vivo dosimetry. Materials and methods. MC simulations involving a Varian True Beam linear accelerator model were performed using the EGSnrc code package. Two custom variants of the U-Net architecture were employed. The MLC dynamic chair sequence and 17 clinical treatment plans, spanning various cancer types and delivery methods, were used to acquire experimental data, and in the MC simulations. The proposed method was tested through 2D gamma index analysis, comparing predicted and measured EPID images. Results. Results showed gamma passing rates of 38.65%, 74.16% and 96.17% (minimum, median, maximum) for a simpler model variant and 52.72%, 80.61% and 96.80% for the more complex model variant. Conclusion. The study highlights the feasibility of integrating MC and DL methodologies for in vivo dosimetry quality assurance in complex radiotherapy delivery.
- Open Access
- 31 January 2023
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (2) , 025004
Cylindrical ionization chamber response in static and dynamic 6 and 15 MV photon beams
Purpose. To investigate the response of the CC13 ionization chamber under non-reference photon beam conditions, focusing on penumbra and build-up regions of static fields and on dynamic intensity-modulated beams. Methods. Measurements were performed in 6 MV 100 × 100, 20 × 100, and 20 × 20 mm2 static fields. Monte Carlo calculations were performed for the static fields and for 6 and 15 MV dynamic beam sequences using a Varian multi-leaf collimator. The chamber was modelled using EGSnrc egs_chamber software. Conversion factors were calculated by relating the absorbed dose to air in the chamber air cavity to the absorbed dose to water. Correction and point-dose correction factors were calculated to quantify the conversion factor variations. Results. The correction factors for positions on the beam central axis and at the penumbra centre were 0.98–1.02 for all static fields and depths investigated. The largest corrections were obtained for chamber positions beyond penumbra centre in the off-axis direction. Point-dose correction factors were 0.54–0.71 at 100 mm depth and their magnitude increased with decreasing field size and measurement depth. Factors of 0.99–1.03 were obtained inside and near the integrated penumbra of the dynamic field at 100 mm depth, and of 0.92–0.94 beyond the integrated penumbra centre. The variations in the ionization chamber response across the integrated dynamic penumbra qualitatively followed the behaviour across penumbra of static fields. Conclusions. Without corrections, the CC13 chamber was of limited usefulness for profile measurements in 20-mm-wide fields. However, measurements in dynamic small irregular beam openings resembling the conditions of pre-treatment patient quality assurance were feasible. Uncorrected ionization chamber response could be applied for dose verification at 100 mm depth inside and close to large gradients of dynamically accumulating high- and low-dose regions assuming 3% tolerance between measured and calculated doses.
- 31 January 2023
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (2) , 025004
Open AccessCylindrical ionization chamber response in static and dynamic 6 and 15 MV photon beams
Purpose. To investigate the response of the CC13 ionization chamber under non-reference photon beam conditions, focusing on penumbra and build-up regions of static fields and on dynamic intensity-modulated beams. Methods. Measurements were performed in 6 MV 100 × 100, 20 × 100, and 20 × 20 mm2 static fields. Monte Carlo calculations were performed for the static fields and for 6 and 15 MV dynamic beam sequences using a Varian multi-leaf collimator. The chamber was modelled using EGSnrc egs_chamber software. Conversion factors were calculated by relating the absorbed dose to air in the chamber air cavity to the absorbed dose to water. Correction and point-dose correction factors were calculated to quantify the conversion factor variations. Results. The correction factors for positions on the beam central axis and at the penumbra centre were 0.98–1.02 for all static fields and depths investigated. The largest corrections were obtained for chamber positions beyond penumbra centre in the off-axis direction. Point-dose correction factors were 0.54–0.71 at 100 mm depth and their magnitude increased with decreasing field size and measurement depth. Factors of 0.99–1.03 were obtained inside and near the integrated penumbra of the dynamic field at 100 mm depth, and of 0.92–0.94 beyond the integrated penumbra centre. The variations in the ionization chamber response across the integrated dynamic penumbra qualitatively followed the behaviour across penumbra of static fields. Conclusions. Without corrections, the CC13 chamber was of limited usefulness for profile measurements in 20-mm-wide fields. However, measurements in dynamic small irregular beam openings resembling the conditions of pre-treatment patient quality assurance were feasible. Uncorrected ionization chamber response could be applied for dose verification at 100 mm depth inside and close to large gradients of dynamically accumulating high- and low-dose regions assuming 3% tolerance between measured and calculated doses.
- Open Access
- 1 October 2021
- Published by Elsevier in Physica Medica
- Vol. 90, 83-90
Effects of lung tissue characterization in radiotherapy of breast cancer under deep inspiration breath hold when using Monte Carlo dosimetry
- 1 October 2021
- Published by Elsevier in Physica Medica
- Vol. 90, 83-90
Open AccessEffects of lung tissue characterization in radiotherapy of breast cancer under deep inspiration breath hold when using Monte Carlo dosimetry
- 1 July 2018
- Published by Elsevier in Physica Medica
- Vol. 51, 32-37
An automated Monte Carlo QC system for volumetric modulated arc therapy: Possibilities and challenges
- 1 July 2018
- Published by Elsevier in Physica Medica
- Vol. 51, 32-37
An automated Monte Carlo QC system for volumetric modulated arc therapy: Possibilities and challenges