- 11 June 2007
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 128 (1) , 124-127
First intercomparison of Tn-Rn discriminative measurements in China
The intercomparison measurements with Tn-Rn discriminative monitor were conducted at the Radon Laboratory of Nanhua University. The intercomparison results indicates that the Tn-Rn discrimination of most monitors (including the solid-state nuclear track detector of participant A and participant B, continuous monitors of RAD7 and RTM2100) keeps well in a wide range of the ratio of Tn to Rn. There are great differences of Tn measurement results among RAD7, RTM2100 and reference instrument. The discussion on the reason of these differences reveals the necessity of improvement on monitor calibration, Tn source make and the necessity of more international intercomparisons.
- 11 June 2007
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 128 (1) , 124-127
First intercomparison of Tn-Rn discriminative measurements in China
The intercomparison measurements with Tn-Rn discriminative monitor were conducted at the Radon Laboratory of Nanhua University. The intercomparison results indicates that the Tn-Rn discrimination of most monitors (including the solid-state nuclear track detector of participant A and participant B, continuous monitors of RAD7 and RTM2100) keeps well in a wide range of the ratio of Tn to Rn. There are great differences of Tn measurement results among RAD7, RTM2100 and reference instrument. The discussion on the reason of these differences reveals the necessity of improvement on monitor calibration, Tn source make and the necessity of more international intercomparisons.
- 10 August 2006
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 45 (3) , 215-220
Calibration of a 220Rn flow-through source
Two reference methods have been established to calibrate the yield of a self-made 220Rn flow-through source. These reference methods include (a) a small scintillation cell flow-through method and (b) a gamma spectrometry method that takes advantage of an activated charcoal. The methods were validated theoretically and experimentally including intercomparison measurements. It is shown that the source is stable with a relative deviation less than 2.5% over 5 years, when the relative humidity ranged from 50 to 90%, and the temperature from 5 to 38°C. The 220Rn monitor used in these reference methods is calibrated without a 220Rn gas source with determinate yield. On the basis of the calibration of the 220Rn source by the methods mentioned above, the accurate calibration of any 220Rn monitor by the self-made 220Rn source with stable yield is feasible.
- 10 August 2006
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 45 (3) , 215-220
Calibration of a 220Rn flow-through source
Two reference methods have been established to calibrate the yield of a self-made 220Rn flow-through source. These reference methods include (a) a small scintillation cell flow-through method and (b) a gamma spectrometry method that takes advantage of an activated charcoal. The methods were validated theoretically and experimentally including intercomparison measurements. It is shown that the source is stable with a relative deviation less than 2.5% over 5 years, when the relative humidity ranged from 50 to 90%, and the temperature from 5 to 38°C. The 220Rn monitor used in these reference methods is calibrated without a 220Rn gas source with determinate yield. On the basis of the calibration of the 220Rn source by the methods mentioned above, the accurate calibration of any 220Rn monitor by the self-made 220Rn source with stable yield is feasible.