Ya Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ya Feng has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Huizhi Zhong
China Southwest Architectural Design & Res Inst Co, Chengdu 610051, Peoples R China
3 shared publicationsJiandong Ran
Chongqing Univ, Sch Architecture & Urban Planning, Chongqing 400044, Peoples R China
3 shared publicationsDongsheng Liu
China Southwest Architecture Design and Research Institute Co. Ltd., Chengdu, China
1 shared publication- Huizhi Zhong
China Southwest Architectural Design and Research Institute Corp., Ltd., Chengdu 610051, China
1 shared publication - Jiandong Ran
School of Architecture and Urban Planning, Chongqing University, Chongqing 400044, China
1 shared publication Jikang Jia
China Southwest Architecture Design and Research Institute Co. Ltd., Chengdu, China
1 shared publication
Latest Publications
- 8 November 2023
- Published by Springer Nature in Building Simulation
- Vol. 17 (1) , 53-70
The noise spectral characteristics and noise reduction schemes of screw air-source heat pump: A case study
- 8 November 2023
- Published by Springer Nature in Building Simulation
- Vol. 17 (1) , 53-70
The noise spectral characteristics and noise reduction schemes of screw air-source heat pump: A case study
- Open Access
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 04004
Influence of External Surface Radiation Properties on Thermal Performance of Walls——Take a typical office building in Chengdu as an example
In this paper, taking a typical office building in Chengdu as an example, the coupling relationship between the radiation properties (short-wave absorption coefficient and long-wave emission coefficient) of the external surface materials of the wall and the insulation types and the insulation performance is studied by using software simulation method. The results show that the internal insulation wall is beneficial to reduce the heating load while the external insulation wall is beneficial to reduce the cooling load. And the external surface material's radiative properties hardly affect the wall insulation type choice. Still, in the case of Chengdu office buildings, interior insulated walls are more conducive to year-round building energy efficiency. In summer, the radiation characteristics of the outer surface material will affect the choice of the best heat transfer coefficient (U-value) of the wall. When the short-wave radiation absorption coefficient is small, the wall with good insulation performance will appear anti-energy-saving phenomenon. Therefore, it is recommended that the regions with high cooling loads fully consider the influence of the external surface material's radiation properties on the wall's thermal performance in the design of the thermal performance of the wall.
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 04004
Open AccessInfluence of External Surface Radiation Properties on Thermal Performance of Walls——Take a typical office building in Chengdu as an example
In this paper, taking a typical office building in Chengdu as an example, the coupling relationship between the radiation properties (short-wave absorption coefficient and long-wave emission coefficient) of the external surface materials of the wall and the insulation types and the insulation performance is studied by using software simulation method. The results show that the internal insulation wall is beneficial to reduce the heating load while the external insulation wall is beneficial to reduce the cooling load. And the external surface material's radiative properties hardly affect the wall insulation type choice. Still, in the case of Chengdu office buildings, interior insulated walls are more conducive to year-round building energy efficiency. In summer, the radiation characteristics of the outer surface material will affect the choice of the best heat transfer coefficient (U-value) of the wall. When the short-wave radiation absorption coefficient is small, the wall with good insulation performance will appear anti-energy-saving phenomenon. Therefore, it is recommended that the regions with high cooling loads fully consider the influence of the external surface material's radiation properties on the wall's thermal performance in the design of the thermal performance of the wall.
- Open Access
- 1 December 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (12) , 2020
Effect of Window Openable Area and Shading on Indoor Thermal Comfort and Energy Efficiency in Residential Buildings with Various Operating Modes
Solar heat gain and natural ventilation cooling of the indoor environment in buildings are highly influenced by the shading and openable area of windows. In addition to the ambient condition, the Heating, ventilation and air conditioning (HVAC) system’s mode of use can affect the windows’ performance, especially when multiple modes are used in combination (mixed-mode). Although many studies have investigated the mixed-mode application, their conditions for starting/shutting down HVAC equipment and controlling window ventilation are inconsistent with the relevant codes. Here, we propose a mixed-mode operation that resolves the gap between the air conditioning operation temperature and the adaptive comfort upper temperature. It investigates residential buildings’ indoor thermal environment and energy efficiency by combining the effective ventilation opening area ratio (REV) and shading design. Simulation results show that our mixed-mode can reduce the indoor overheating hours by about 50% and the building’s energy consumption by about 50%. We thereby conclude that the openable area of exterior windows in residential buildings in Chongqing should not be less than 10% of the room’s floor axis area where the exterior windows are located. In general, our study expands the existing knowledge of passive energy-saving measures and provides a method for further research on building energy design in hot summer and cold winter regions.
- 1 December 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (12) , 2020
Open AccessEffect of Window Openable Area and Shading on Indoor Thermal Comfort and Energy Efficiency in Residential Buildings with Various Operating Modes
Solar heat gain and natural ventilation cooling of the indoor environment in buildings are highly influenced by the shading and openable area of windows. In addition to the ambient condition, the Heating, ventilation and air conditioning (HVAC) system’s mode of use can affect the windows’ performance, especially when multiple modes are used in combination (mixed-mode). Although many studies have investigated the mixed-mode application, their conditions for starting/shutting down HVAC equipment and controlling window ventilation are inconsistent with the relevant codes. Here, we propose a mixed-mode operation that resolves the gap between the air conditioning operation temperature and the adaptive comfort upper temperature. It investigates residential buildings’ indoor thermal environment and energy efficiency by combining the effective ventilation opening area ratio (REV) and shading design. Simulation results show that our mixed-mode can reduce the indoor overheating hours by about 50% and the building’s energy consumption by about 50%. We thereby conclude that the openable area of exterior windows in residential buildings in Chongqing should not be less than 10% of the room’s floor axis area where the exterior windows are located. In general, our study expands the existing knowledge of passive energy-saving measures and provides a method for further research on building energy design in hot summer and cold winter regions.
- Open Access
- 30 June 2020
- Published by EDP Sciences
- Vol. 172, 16003
Energy performance assessment and optimization of extensive green roofs in different climate zones of China
There are many research and engineering projects on extensive green roofs, however, there is still no design guide for green roofs` climate energy efficiency, which limits the further promotion and usage of it, especially in China containing five climate zones. Taking different climate zones of China as examples, the verified building model is used in the DesignBuilder software, and 2-4 typical cities in each climate zone are selected, then combined the genetic algorithm (GA-Ⅱ) to optimize the energy efficiency of the building under green roofs. The results show that in all the cities studied in the five climatic zones, extensive green roofs are more energy efficient than ordinary thermal insulation roofs, and the energy saving rate is between 1-26.4%; except for the Nenjiang, which the energy is mainly used for heating, the cooling energy consumption is reduced and the heating energy consumption is increased after the optimized green roof is adopted in other cities; it is also found that the energy saving rate of the green roof with optimization has a high correlation with the total annual solar radiation value of the city. In addition, the energy efficiency optimization of green roofs in all cities shows that a larger leaf area index is more conducive to energy conservation; however, in southern China, it is not recommended to use a thermal insulation layer in the roof structural layer below the soil.
- 30 June 2020
- Published by EDP Sciences
- Vol. 172, 16003
Open AccessEnergy performance assessment and optimization of extensive green roofs in different climate zones of China
There are many research and engineering projects on extensive green roofs, however, there is still no design guide for green roofs` climate energy efficiency, which limits the further promotion and usage of it, especially in China containing five climate zones. Taking different climate zones of China as examples, the verified building model is used in the DesignBuilder software, and 2-4 typical cities in each climate zone are selected, then combined the genetic algorithm (GA-Ⅱ) to optimize the energy efficiency of the building under green roofs. The results show that in all the cities studied in the five climatic zones, extensive green roofs are more energy efficient than ordinary thermal insulation roofs, and the energy saving rate is between 1-26.4%; except for the Nenjiang, which the energy is mainly used for heating, the cooling energy consumption is reduced and the heating energy consumption is increased after the optimized green roof is adopted in other cities; it is also found that the energy saving rate of the green roof with optimization has a high correlation with the total annual solar radiation value of the city. In addition, the energy efficiency optimization of green roofs in all cities shows that a larger leaf area index is more conducive to energy conservation; however, in southern China, it is not recommended to use a thermal insulation layer in the roof structural layer below the soil.
- 1 October 2013
- Published by Springer Nature in Lecture Notes in Electrical Engineering
- p. 167-173
Study on Thermal Resistance of Basement Exterior Wall in Hot Summer and Cold Winter Zone
- 1 October 2013
- Published by Springer Nature in Lecture Notes in Electrical Engineering
- p. 167-173
Study on Thermal Resistance of Basement Exterior Wall in Hot Summer and Cold Winter Zone