Helena Jäntti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Helena Jäntti has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Eemu-Samuli Väliaho
Faculty of Medicine, University of Helsinki, Helsinki, Finland
8 shared publications - Juha Hartikainen
University of Eastern Finland
8 shared publications - Jukka Antero Lipponen
Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
8 shared publications - Onni E. Santala
School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 8, Kuopio, 70210, Finland, 358 443358523
8 shared publications - Tero J. Martikainen
Department of Prehospital Emergency Care, Acute Services, Kuopio University Hospital, Kuopio, Finland
8 shared publications - Tuomas T. Rissanen
Heart Center, North Karelia Central Hospital, Siunsote
8 shared publications
Latest Publications
- Open Access
- 30 June 2026
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 10, e83714
Deep Neural Networks for Automatic Atrial Fibrillation Detection Using Long-Term Ambulatory Electrocardiography: Retrospective Diagnostic Accuracy Study
Background: Atrial fibrillation (AF), the most prevalent cardiac arrhythmia, affects 2% to 4% of the global adult population and is associated with an increased risk of stroke. Early diagnosis of AF and atrial flutter (AFL) is crucial due to their association with stroke risk and the challenge posed by their often asymptomatic and episodic nature. Traditional electrocardiogram (ECG) interpretation requires substantial expert input and can be challenging, especially with poor-quality ECGs. Objective: This study aimed to evaluate the performance of a deep neural network (DNN) model in detecting AF/AFL from a large, heterogeneous set of long-term ambulatory ECG recordings, including clinical data collected over 6 months at a university hospital, and assess its effectiveness in a setting reflecting the diversity and complexity of real-world clinical data. Methods: The research combined public datasets totaling 10,248 patients, ECG data from our previous studies (648 patients), and authentic long-term ECG recordings from 4346 patients at Kuopio University Hospital for development of the DNN model. Its clinical accuracy and generalizability were assessed using a separate test dataset consisting of 1039 pseudonymized long-term ECG recordings from 1010 patients, all thoroughly reviewed and annotated by experts. Results: The DNN model demonstrated high effectiveness, achieving 96.4% sensitivity and more than 99.99% specificity for time-level AF and AFL detection. At the recording level, it identified AF and AFL with 100% sensitivity and 98.77% specificity, producing false positives in only 1.2% (11/897) of recordings, of which 81.8% (9/11) had other non–AF/AFL arrhythmias. The model maintained high performance across diverse patient characteristics, including varying ages, comorbidities, coexisting arrhythmias, and poor-quality ECG recordings. Conclusions: The results demonstrate that the proposed DNN model may support automated screening for AF and AFL in long-term ambulatory ECG recordings and may reduce manual review workload in clinical practice.
- 30 June 2026
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 10, e83714
Open AccessDeep Neural Networks for Automatic Atrial Fibrillation Detection Using Long-Term Ambulatory Electrocardiography: Retrospective Diagnostic Accuracy Study
Background: Atrial fibrillation (AF), the most prevalent cardiac arrhythmia, affects 2% to 4% of the global adult population and is associated with an increased risk of stroke. Early diagnosis of AF and atrial flutter (AFL) is crucial due to their association with stroke risk and the challenge posed by their often asymptomatic and episodic nature. Traditional electrocardiogram (ECG) interpretation requires substantial expert input and can be challenging, especially with poor-quality ECGs. Objective: This study aimed to evaluate the performance of a deep neural network (DNN) model in detecting AF/AFL from a large, heterogeneous set of long-term ambulatory ECG recordings, including clinical data collected over 6 months at a university hospital, and assess its effectiveness in a setting reflecting the diversity and complexity of real-world clinical data. Methods: The research combined public datasets totaling 10,248 patients, ECG data from our previous studies (648 patients), and authentic long-term ECG recordings from 4346 patients at Kuopio University Hospital for development of the DNN model. Its clinical accuracy and generalizability were assessed using a separate test dataset consisting of 1039 pseudonymized long-term ECG recordings from 1010 patients, all thoroughly reviewed and annotated by experts. Results: The DNN model demonstrated high effectiveness, achieving 96.4% sensitivity and more than 99.99% specificity for time-level AF and AFL detection. At the recording level, it identified AF and AFL with 100% sensitivity and 98.77% specificity, producing false positives in only 1.2% (11/897) of recordings, of which 81.8% (9/11) had other non–AF/AFL arrhythmias. The model maintained high performance across diverse patient characteristics, including varying ages, comorbidities, coexisting arrhythmias, and poor-quality ECG recordings. Conclusions: The results demonstrate that the proposed DNN model may support automated screening for AF and AFL in long-term ambulatory ECG recordings and may reduce manual review workload in clinical practice.
- Open Access
- 23 April 2026
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 14 (1) , e82475
A Deep Neural Network for Interpreting Wearable Electrocardiogram Data in Atrial Fibrillation: Prospective Observational Diagnostic Accuracy Study
Background: Atrial fibrillation (AF) and atrial flutter (AFL) are common arrhythmias associated with the risk of ischemic stroke, which can be reduced with anticoagulation therapy. Thus, early diagnosis of AF and AFL is essential. However, diagnosis may be challenging due to the paroxysmal and asymptomatic nature of these arrhythmias. Objective: Current diagnostic workflows involve time-consuming and resource-intensive manual review of noisy signals and prolonged recordings. We evaluated a mobile system that combines a wireless wearable single-lead chest strap electrocardiogram (ECG) and a novel deep neural network (DNN)–based artificial intelligence (AI) method for detecting AF/AFL episodes, AF/AFL burden, and rhythm change and estimated the delay in the detection of rhythm change from AF/AFL to sinus rhythm. We also assessed the rhythm classification performance. Methods: A total of 116 patients with recent-onset AF or AFL undergoing cardioversion were monitored using a mobile single-lead chest strap ECG system. Simultaneously, a 3-lead Holter ECG served as the reference. The DNN-based AI analyzed the single-lead chest strap ECG data to detect AF/AFL, non-AF/AFLrhythm, and noninterpretable segments, as well as to estimate AF/AFL burden and detect rhythm change. Performance metrics included sensitivity, specificity, positive predictive value, negative predictive value, and intraclass correlation coefficient for AF and AFL burden estimation. Results: The sensitivity and specificity for detecting AF/AFL were 91.9% (204.9/223.0 h) and 99.6% (242.4/243.5 h), respectively. The sensitivity for detecting AF was 96.2% (191.5/199.0 h), whereas it was 55.8% (13.4/24.0 h) for detecting AFL. The positive predictive value and negative predictive value for AF/AFL detection were 99.5% (204.9/206.0 h) and 93.1% (242.4/260.5 h), respectively. The intraclass correlation coefficient between the AF/AFL burden estimated by the DNN-based AI method and that derived from the physician-interpreted reference ECG was 0.96 (95% CI: 0.94‐0.97; P <.001). Rhythm change detection occurred within 1 minute in most cases. Conclusions: The mobile single-lead chest strap ECG system powered by a DNN-based AI algorithm demonstrated strong performance in detecting AF, estimating AF burden, and recognizing rhythm change to sinus rhythm. This AI-driven approach enables automated and accurate rhythm analysis, supporting clinical decision-making. Further validation in real-world ambulatory settings is warranted.
- 23 April 2026
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 14 (1) , e82475
Open AccessA Deep Neural Network for Interpreting Wearable Electrocardiogram Data in Atrial Fibrillation: Prospective Observational Diagnostic Accuracy Study
Background: Atrial fibrillation (AF) and atrial flutter (AFL) are common arrhythmias associated with the risk of ischemic stroke, which can be reduced with anticoagulation therapy. Thus, early diagnosis of AF and AFL is essential. However, diagnosis may be challenging due to the paroxysmal and asymptomatic nature of these arrhythmias. Objective: Current diagnostic workflows involve time-consuming and resource-intensive manual review of noisy signals and prolonged recordings. We evaluated a mobile system that combines a wireless wearable single-lead chest strap electrocardiogram (ECG) and a novel deep neural network (DNN)–based artificial intelligence (AI) method for detecting AF/AFL episodes, AF/AFL burden, and rhythm change and estimated the delay in the detection of rhythm change from AF/AFL to sinus rhythm. We also assessed the rhythm classification performance. Methods: A total of 116 patients with recent-onset AF or AFL undergoing cardioversion were monitored using a mobile single-lead chest strap ECG system. Simultaneously, a 3-lead Holter ECG served as the reference. The DNN-based AI analyzed the single-lead chest strap ECG data to detect AF/AFL, non-AF/AFLrhythm, and noninterpretable segments, as well as to estimate AF/AFL burden and detect rhythm change. Performance metrics included sensitivity, specificity, positive predictive value, negative predictive value, and intraclass correlation coefficient for AF and AFL burden estimation. Results: The sensitivity and specificity for detecting AF/AFL were 91.9% (204.9/223.0 h) and 99.6% (242.4/243.5 h), respectively. The sensitivity for detecting AF was 96.2% (191.5/199.0 h), whereas it was 55.8% (13.4/24.0 h) for detecting AFL. The positive predictive value and negative predictive value for AF/AFL detection were 99.5% (204.9/206.0 h) and 93.1% (242.4/260.5 h), respectively. The intraclass correlation coefficient between the AF/AFL burden estimated by the DNN-based AI method and that derived from the physician-interpreted reference ECG was 0.96 (95% CI: 0.94‐0.97; P <.001). Rhythm change detection occurred within 1 minute in most cases. Conclusions: The mobile single-lead chest strap ECG system powered by a DNN-based AI algorithm demonstrated strong performance in detecting AF, estimating AF burden, and recognizing rhythm change to sinus rhythm. This AI-driven approach enables automated and accurate rhythm analysis, supporting clinical decision-making. Further validation in real-world ambulatory settings is warranted.
- Open Access
- 13 September 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Deep Neural Networks for Automatic Atrial Fibrillation Detection Using Long-Term Ambulatory ECG: A Diagnostic Accuracy Study (Preprint)
UNSTRUCTURED Background and Aims: Atrial fibrillation (AF), the most prevalent cardiac arrhythmia, affects 2-4% of the global adult population and is linked with an increased risk of stroke. Early diagnosis of AF and atrial flutter (AFL) is crucial due to their association with stroke risk and the challenge posed by their often asymptomatic and episodic nature. Traditional ECG interpretation, requiring significant expert input, can be challenging, especially with poor-quality ECGs. This study evaluates the performance of a deep neural network (DNN) model in detecting AF/AFL from a large, heterogeneous set of long-term ambulatory ECG recordings, including real-world clinical data collected over six months at a university hospital. The aim was to assess its effectiveness in a setting reflecting the diversity and complexity of real-world clinical data. Methods: The research combined public datasets totaling 10,896 patients and authentic long-term ECG recordings from 4,346 patients at Kuopio University Hospital for the DNN model’s development. Its clinical accuracy and generalizability were assessed using clinical data and 1039 anonymized long-term ECG recordings from 1010 patients, all thoroughly reviewed and annotated by experts. Results: The DNN model demonstrated high effectiveness, achieving 96.35% sensitivity and over 99.99% specificity in time-level AF/AFL detection. At the patient level, it identified AF/AFL with 100% sensitivity and 98.77% specificity, producing false positives in only 11 (1.23%) patients, of which nine had other AF/AFL arrhythmias. The model was highly effective across diverse patient groups, including various ages, comorbidities, other arrhythmias, and poor-quality ECGs. Conclusions: This study showcases the potential of the DNN model to significantly enhance the interpretation of long-term ambulatory ECG recordings, offering an efficient tool for AF/AFL detection, which could decrease manual labor and streamline patient management.
- 13 September 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessDeep Neural Networks for Automatic Atrial Fibrillation Detection Using Long-Term Ambulatory ECG: A Diagnostic Accuracy Study (Preprint)
UNSTRUCTURED Background and Aims: Atrial fibrillation (AF), the most prevalent cardiac arrhythmia, affects 2-4% of the global adult population and is linked with an increased risk of stroke. Early diagnosis of AF and atrial flutter (AFL) is crucial due to their association with stroke risk and the challenge posed by their often asymptomatic and episodic nature. Traditional ECG interpretation, requiring significant expert input, can be challenging, especially with poor-quality ECGs. This study evaluates the performance of a deep neural network (DNN) model in detecting AF/AFL from a large, heterogeneous set of long-term ambulatory ECG recordings, including real-world clinical data collected over six months at a university hospital. The aim was to assess its effectiveness in a setting reflecting the diversity and complexity of real-world clinical data. Methods: The research combined public datasets totaling 10,896 patients and authentic long-term ECG recordings from 4,346 patients at Kuopio University Hospital for the DNN model’s development. Its clinical accuracy and generalizability were assessed using clinical data and 1039 anonymized long-term ECG recordings from 1010 patients, all thoroughly reviewed and annotated by experts. Results: The DNN model demonstrated high effectiveness, achieving 96.35% sensitivity and over 99.99% specificity in time-level AF/AFL detection. At the patient level, it identified AF/AFL with 100% sensitivity and 98.77% specificity, producing false positives in only 11 (1.23%) patients, of which nine had other AF/AFL arrhythmias. The model was highly effective across diverse patient groups, including various ages, comorbidities, other arrhythmias, and poor-quality ECGs. Conclusions: This study showcases the potential of the DNN model to significantly enhance the interpretation of long-term ambulatory ECG recordings, offering an efficient tool for AF/AFL detection, which could decrease manual labor and streamline patient management.
- Open Access
- 23 May 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 6 (4) , 723-732
Photoplethysmography in recent-onset atrial fibrillation: automatic detection of rhythm change and burden
Aims: Atrial fibrillation (AF) is the most common arrhythmia, increasing stroke risk. Detecting AF is challenging due to its asymptomatic and paroxysmal nature. This study combines photoplethysmography (PPG) with automated techniques to detect AF, assess AF burden, and monitor rhythm changes from AF to sinus rhythm (SR). Methods and results: Ninety patients with recent-onset (duration <48 h) AF, scheduled for cardioversion, were monitored using a three-channel PPG armband on the upper arm. An ambulatory three-lead electrocardiogram (ECG) served as the gold standard. PPG recordings were segmented into 10-, 20-, 30-, and 60-min detection windows. Automated detection identified SR and AF episodes, rhythm changes, and AF burden. Sensitivities, specificities, positive predictive values (PPVs), and negative predictive values (NPVs) for rhythm detection were calculated, and the intraclass correlation coefficients (ICCs) for PPG-based AF burden were compared to the gold standard. Monitoring time ranged from 1.0 to 8.2 h per patient. Sensitivities, specificities, PPVs, and NPVs for AF detection were 93.9–94.6, 99.5–99.8, 99.4–99.7, and 93.7–95.0%, respectively. The ICC (0.97–0.98) indicated excellent agreement between PPG and the gold standard in estimating AF burden, with differences of −6.3 to −8.3 min (5.5–6.8%). Rhythm changes from AF to SR were detected in all patients (sensitivity 100%), with detection delays of 4.1 ± 1.4, 8.7 ± 2.8, 13.7 ± 3.9, and 27.8 ± 7.1 min depending on the detection window. Conclusion: Photoplethysmography with automated analysis shows promise in detecting AF, AF burden, and rhythm changes, indicating its potential in AF screening. Clinical trial registration: NCT04917653
- 23 May 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 6 (4) , 723-732
Open AccessPhotoplethysmography in recent-onset atrial fibrillation: automatic detection of rhythm change and burden
Aims: Atrial fibrillation (AF) is the most common arrhythmia, increasing stroke risk. Detecting AF is challenging due to its asymptomatic and paroxysmal nature. This study combines photoplethysmography (PPG) with automated techniques to detect AF, assess AF burden, and monitor rhythm changes from AF to sinus rhythm (SR). Methods and results: Ninety patients with recent-onset (duration <48 h) AF, scheduled for cardioversion, were monitored using a three-channel PPG armband on the upper arm. An ambulatory three-lead electrocardiogram (ECG) served as the gold standard. PPG recordings were segmented into 10-, 20-, 30-, and 60-min detection windows. Automated detection identified SR and AF episodes, rhythm changes, and AF burden. Sensitivities, specificities, positive predictive values (PPVs), and negative predictive values (NPVs) for rhythm detection were calculated, and the intraclass correlation coefficients (ICCs) for PPG-based AF burden were compared to the gold standard. Monitoring time ranged from 1.0 to 8.2 h per patient. Sensitivities, specificities, PPVs, and NPVs for AF detection were 93.9–94.6, 99.5–99.8, 99.4–99.7, and 93.7–95.0%, respectively. The ICC (0.97–0.98) indicated excellent agreement between PPG and the gold standard in estimating AF burden, with differences of −6.3 to −8.3 min (5.5–6.8%). Rhythm changes from AF to SR were detected in all patients (sensitivity 100%), with detection delays of 4.1 ± 1.4, 8.7 ± 2.8, 13.7 ± 3.9, and 27.8 ± 7.1 min depending on the detection window. Conclusion: Photoplethysmography with automated analysis shows promise in detecting AF, AF burden, and rhythm changes, indicating its potential in AF screening. Clinical trial registration: NCT04917653
- Open Access
- 21 June 2022
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 6 (1) , e31230
Continuous mHealth Patch Monitoring for the Algorithm-Based Detection of Atrial Fibrillation: Feasibility and Diagnostic Accuracy Study
Background: The detection of atrial fibrillation (AF) is a major clinical challenge as AF is often paroxysmal and asymptomatic. Novel mobile health (mHealth) technologies could provide a cost-effective and reliable solution for AF screening. However, many of these techniques have not been clinically validated. Objective: The purpose of this study is to evaluate the feasibility and reliability of artificial intelligence (AI) arrhythmia analysis for AF detection with an mHealth patch device designed for personal well-being. Methods: Patients (N=178) with an AF (n=79, 44%) or sinus rhythm (n=99, 56%) were recruited from the emergency care department. A single-lead, 24-hour, electrocardiogram-based heart rate variability (HRV) measurement was recorded with the mHealth patch device and analyzed with a novel AI arrhythmia analysis software. Simultaneously registered 3-lead electrocardiograms (Holter) served as the gold standard for the final rhythm diagnostics. Results: Of the HRV data produced by the single-lead mHealth patch, 81.5% (3099/3802 hours) were interpretable, and the subject-based median for interpretable HRV data was 99% (25th percentile=77% and 75th percentile=100%). The AI arrhythmia detection algorithm detected AF correctly in all patients in the AF group and suggested the presence of AF in 5 patients in the control group, resulting in a subject-based AF detection accuracy of 97.2%, a sensitivity of 100%, and a specificity of 94.9%. The time-based AF detection accuracy, sensitivity, and specificity of the AI arrhythmia detection algorithm were 98.7%, 99.6%, and 98.0%, respectively. Conclusions: The 24-hour HRV monitoring by the mHealth patch device enabled accurate automatic AF detection. Thus, the wearable mHealth patch device with AI arrhythmia analysis is a novel method for AF screening. Trial Registration: ClinicalTrials.gov NCT03507335; https://clinicaltrials.gov/ct2/show/NCT03507335
- 21 June 2022
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 6 (1) , e31230
Open AccessContinuous mHealth Patch Monitoring for the Algorithm-Based Detection of Atrial Fibrillation: Feasibility and Diagnostic Accuracy Study
Background: The detection of atrial fibrillation (AF) is a major clinical challenge as AF is often paroxysmal and asymptomatic. Novel mobile health (mHealth) technologies could provide a cost-effective and reliable solution for AF screening. However, many of these techniques have not been clinically validated. Objective: The purpose of this study is to evaluate the feasibility and reliability of artificial intelligence (AI) arrhythmia analysis for AF detection with an mHealth patch device designed for personal well-being. Methods: Patients (N=178) with an AF (n=79, 44%) or sinus rhythm (n=99, 56%) were recruited from the emergency care department. A single-lead, 24-hour, electrocardiogram-based heart rate variability (HRV) measurement was recorded with the mHealth patch device and analyzed with a novel AI arrhythmia analysis software. Simultaneously registered 3-lead electrocardiograms (Holter) served as the gold standard for the final rhythm diagnostics. Results: Of the HRV data produced by the single-lead mHealth patch, 81.5% (3099/3802 hours) were interpretable, and the subject-based median for interpretable HRV data was 99% (25th percentile=77% and 75th percentile=100%). The AI arrhythmia detection algorithm detected AF correctly in all patients in the AF group and suggested the presence of AF in 5 patients in the control group, resulting in a subject-based AF detection accuracy of 97.2%, a sensitivity of 100%, and a specificity of 94.9%. The time-based AF detection accuracy, sensitivity, and specificity of the AI arrhythmia detection algorithm were 98.7%, 99.6%, and 98.0%, respectively. Conclusions: The 24-hour HRV monitoring by the mHealth patch device enabled accurate automatic AF detection. Thus, the wearable mHealth patch device with AI arrhythmia analysis is a novel method for AF screening. Trial Registration: ClinicalTrials.gov NCT03507335; https://clinicaltrials.gov/ct2/show/NCT03507335
- Open Access
- 22 October 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (10) , e29933
Automatic Mobile Health Arrhythmia Monitoring for the Detection of Atrial Fibrillation: Prospective Feasibility, Accuracy, and User Experience Study
Background: Atrial fibrillation (AF) is the most common tachyarrhythmia and associated with a risk of stroke. The detection and diagnosis of AF represent a major clinical challenge due to AF’s asymptomatic and intermittent nature. Novel consumer-grade mobile health (mHealth) products with automatic arrhythmia detection could be an option for long-term electrocardiogram (ECG)-based rhythm monitoring and AF detection. Objective: We evaluated the feasibility and accuracy of a wearable automated mHealth arrhythmia monitoring system, including a consumer-grade, single-lead heart rate belt ECG device (heart belt), a mobile phone application, and a cloud service with an artificial intelligence (AI) arrhythmia detection algorithm for AF detection. The specific aim of this proof-of-concept study was to test the feasibility of the entire sequence of operations from ECG recording to AI arrhythmia analysis and ultimately to final AF detection. Methods: Patients (n=159) with an AF (n=73) or sinus rhythm (n=86) were recruited from the emergency department. A single-lead heart belt ECG was recorded for 24 hours. Simultaneously registered 3-lead ECGs (Holter) served as the gold standard for the final rhythm diagnostics and as a reference device in a user experience survey with patients over 65 years of age (high-risk group). Results: The heart belt provided a high-quality ECG recording for visual interpretation resulting in 100% accuracy, sensitivity, and specificity of AF detection. The accuracy of AF detection with the automatic AI arrhythmia detection from the heart belt ECG recording was also high (97.5%), and the sensitivity and specificity were 100% and 95.4%, respectively. The correlation between the automatic estimated AF burden and the true AF burden from Holter recording was >0.99 with a mean burden error of 0.05 (SD 0.26) hours. The heart belt demonstrated good user experience and did not significantly interfere with the patient’s daily activities. The patients preferred the heart belt over Holter ECG for rhythm monitoring (85/110, 77% heart belt vs 77/109, 71% Holter, P=.049). Conclusions: A consumer-grade, single-lead ECG heart belt provided good-quality ECG for rhythm diagnosis. The mHealth arrhythmia monitoring system, consisting of heart-belt ECG, a mobile phone application, and an automated AF detection achieved AF detection with high accuracy, sensitivity, and specificity. In addition, the mHealth arrhythmia monitoring system showed good user experience. Trial Registration: ClinicalTrials.gov NCT03507335; https://clinicaltrials.gov/ct2/show/NCT03507335
- 22 October 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (10) , e29933
Open AccessAutomatic Mobile Health Arrhythmia Monitoring for the Detection of Atrial Fibrillation: Prospective Feasibility, Accuracy, and User Experience Study
Background: Atrial fibrillation (AF) is the most common tachyarrhythmia and associated with a risk of stroke. The detection and diagnosis of AF represent a major clinical challenge due to AF’s asymptomatic and intermittent nature. Novel consumer-grade mobile health (mHealth) products with automatic arrhythmia detection could be an option for long-term electrocardiogram (ECG)-based rhythm monitoring and AF detection. Objective: We evaluated the feasibility and accuracy of a wearable automated mHealth arrhythmia monitoring system, including a consumer-grade, single-lead heart rate belt ECG device (heart belt), a mobile phone application, and a cloud service with an artificial intelligence (AI) arrhythmia detection algorithm for AF detection. The specific aim of this proof-of-concept study was to test the feasibility of the entire sequence of operations from ECG recording to AI arrhythmia analysis and ultimately to final AF detection. Methods: Patients (n=159) with an AF (n=73) or sinus rhythm (n=86) were recruited from the emergency department. A single-lead heart belt ECG was recorded for 24 hours. Simultaneously registered 3-lead ECGs (Holter) served as the gold standard for the final rhythm diagnostics and as a reference device in a user experience survey with patients over 65 years of age (high-risk group). Results: The heart belt provided a high-quality ECG recording for visual interpretation resulting in 100% accuracy, sensitivity, and specificity of AF detection. The accuracy of AF detection with the automatic AI arrhythmia detection from the heart belt ECG recording was also high (97.5%), and the sensitivity and specificity were 100% and 95.4%, respectively. The correlation between the automatic estimated AF burden and the true AF burden from Holter recording was >0.99 with a mean burden error of 0.05 (SD 0.26) hours. The heart belt demonstrated good user experience and did not significantly interfere with the patient’s daily activities. The patients preferred the heart belt over Holter ECG for rhythm monitoring (85/110, 77% heart belt vs 77/109, 71% Holter, P=.049). Conclusions: A consumer-grade, single-lead ECG heart belt provided good-quality ECG for rhythm diagnosis. The mHealth arrhythmia monitoring system, consisting of heart-belt ECG, a mobile phone application, and an automated AF detection achieved AF detection with high accuracy, sensitivity, and specificity. In addition, the mHealth arrhythmia monitoring system showed good user experience. Trial Registration: ClinicalTrials.gov NCT03507335; https://clinicaltrials.gov/ct2/show/NCT03507335
- Open Access
- 12 September 2021
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 66 (1) , 125-131
Frequency, indications and success of out‐of‐hospital intubations in Finnish children
Background: Earlier studies have shown variable results regarding the success of paediatric emergency endotracheal intubation between different settings and operators. We aimed to describe the paediatric population intubated by physician‐staffed helicopter emergency medical service (HEMS) and evaluate the factors associated with overall and first‐pass success (FPS).Methods: We conducted a retrospective observational cohort study in Finland including all children less than 16 years old who required endotracheal intubation by a HEMS physician from January 2014 to August 2019. Utilising a national HEMS database, we analysed the incidence, indications, overall and first‐pass success rates of endotracheal intubation.Results: A total of 2731 children were encountered by HEMS, and intubation was attempted in 245 (9%); of these, 22 were younger than 1 year, 103 were aged 1–5 years and 120 were aged 6–15 years. The most common indications for airway management were cardiac arrest for the youngest age group, neurological reasons (e.g., seizures) for those aged 1–5 years and trauma for those aged 6–15. The HEMS physicians had an overall success rate of 100% (95% CI: 98–100) and an FPS rate of 86% (95% CI: 82–90). The FPS rate was lower in the youngest age group (p = .002) and for patients in cardiac arrest (p < .001).Conclusions: Emergency endotracheal intubation of children is successfully performed by a physician staffed HEMS unit even though these procedures are rare. To improve the care, emphasis should be on airway management of infants and patients in cardiac arrest.
- 12 September 2021
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 66 (1) , 125-131
Open AccessFrequency, indications and success of out‐of‐hospital intubations in Finnish children
Background: Earlier studies have shown variable results regarding the success of paediatric emergency endotracheal intubation between different settings and operators. We aimed to describe the paediatric population intubated by physician‐staffed helicopter emergency medical service (HEMS) and evaluate the factors associated with overall and first‐pass success (FPS).Methods: We conducted a retrospective observational cohort study in Finland including all children less than 16 years old who required endotracheal intubation by a HEMS physician from January 2014 to August 2019. Utilising a national HEMS database, we analysed the incidence, indications, overall and first‐pass success rates of endotracheal intubation.Results: A total of 2731 children were encountered by HEMS, and intubation was attempted in 245 (9%); of these, 22 were younger than 1 year, 103 were aged 1–5 years and 120 were aged 6–15 years. The most common indications for airway management were cardiac arrest for the youngest age group, neurological reasons (e.g., seizures) for those aged 1–5 years and trauma for those aged 6–15. The HEMS physicians had an overall success rate of 100% (95% CI: 98–100) and an FPS rate of 86% (95% CI: 82–90). The FPS rate was lower in the youngest age group (p = .002) and for patients in cardiac arrest (p < .001).Conclusions: Emergency endotracheal intubation of children is successfully performed by a physician staffed HEMS unit even though these procedures are rare. To improve the care, emphasis should be on airway management of infants and patients in cardiac arrest.
- Open Access
- 14 June 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Continuous mHealth Patch Monitoring for the Algorithm-Based Detection of Atrial Fibrillation: Feasibility and Diagnostic Accuracy Study (Preprint)
BACKGROUND The detection of atrial fibrillation (AF) is a major clinical challenge as AF is often paroxysmal and asymptomatic. Novel mobile health (mHealth) technologies could provide a cost-effective and reliable solution for AF screening. However, many of these techniques have not been clinically validated. OBJECTIVE The purpose of this study is to evaluate the feasibility and reliability of artificial intelligence (AI) arrhythmia analysis for AF detection with an mHealth patch device designed for personal well-being. METHODS Patients (N=178) with an AF (n=79, 44%) or sinus rhythm (n=99, 56%) were recruited from the emergency care department. A single-lead, 24-hour, electrocardiogram-based heart rate variability (HRV) measurement was recorded with the mHealth patch device and analyzed with a novel AI arrhythmia analysis software. Simultaneously registered 3-lead electrocardiograms (Holter) served as the gold standard for the final rhythm diagnostics. RESULTS Of the HRV data produced by the single-lead mHealth patch, 81.5% (3099/3802 hours) were interpretable, and the subject-based median for interpretable HRV data was 99% (25th percentile=77% and 75th percentile=100%). The AI arrhythmia detection algorithm detected AF correctly in all patients in the AF group and suggested the presence of AF in 5 patients in the control group, resulting in a subject-based AF detection accuracy of 97.2%, a sensitivity of 100%, and a specificity of 94.9%. The time-based AF detection accuracy, sensitivity, and specificity of the AI arrhythmia detection algorithm were 98.7%, 99.6%, and 98.0%, respectively. CONCLUSIONS The 24-hour HRV monitoring by the mHealth patch device enabled accurate automatic AF detection. Thus, the wearable mHealth patch device with AI arrhythmia analysis is a novel method for AF screening. CLINICALTRIAL ClinicalTrials.gov NCT03507335; https://clinicaltrials.gov/ct2/show/NCT03507335
- 14 June 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessContinuous mHealth Patch Monitoring for the Algorithm-Based Detection of Atrial Fibrillation: Feasibility and Diagnostic Accuracy Study (Preprint)
BACKGROUND The detection of atrial fibrillation (AF) is a major clinical challenge as AF is often paroxysmal and asymptomatic. Novel mobile health (mHealth) technologies could provide a cost-effective and reliable solution for AF screening. However, many of these techniques have not been clinically validated. OBJECTIVE The purpose of this study is to evaluate the feasibility and reliability of artificial intelligence (AI) arrhythmia analysis for AF detection with an mHealth patch device designed for personal well-being. METHODS Patients (N=178) with an AF (n=79, 44%) or sinus rhythm (n=99, 56%) were recruited from the emergency care department. A single-lead, 24-hour, electrocardiogram-based heart rate variability (HRV) measurement was recorded with the mHealth patch device and analyzed with a novel AI arrhythmia analysis software. Simultaneously registered 3-lead electrocardiograms (Holter) served as the gold standard for the final rhythm diagnostics. RESULTS Of the HRV data produced by the single-lead mHealth patch, 81.5% (3099/3802 hours) were interpretable, and the subject-based median for interpretable HRV data was 99% (25th percentile=77% and 75th percentile=100%). The AI arrhythmia detection algorithm detected AF correctly in all patients in the AF group and suggested the presence of AF in 5 patients in the control group, resulting in a subject-based AF detection accuracy of 97.2%, a sensitivity of 100%, and a specificity of 94.9%. The time-based AF detection accuracy, sensitivity, and specificity of the AI arrhythmia detection algorithm were 98.7%, 99.6%, and 98.0%, respectively. CONCLUSIONS The 24-hour HRV monitoring by the mHealth patch device enabled accurate automatic AF detection. Thus, the wearable mHealth patch device with AI arrhythmia analysis is a novel method for AF screening. CLINICALTRIAL ClinicalTrials.gov NCT03507335; https://clinicaltrials.gov/ct2/show/NCT03507335
- Open Access
- 26 April 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Automatic Mobile Health Arrhythmia Monitoring for the Detection of Atrial Fibrillation: Prospective Feasibility, Accuracy, and User Experience Study (Preprint)
BACKGROUND Atrial fibrillation (AF) is the most common tachyarrhythmia and associated with a risk of stroke. The detection and diagnosis of AF represent a major clinical challenge due to AF’s asymptomatic and intermittent nature. Novel consumer-grade mobile health (mHealth) products with automatic arrhythmia detection could be an option for long-term electrocardiogram (ECG)-based rhythm monitoring and AF detection. OBJECTIVE We evaluated the feasibility and accuracy of a wearable automated mHealth arrhythmia monitoring system, including a consumer-grade, single-lead heart rate belt ECG device (heart belt), a mobile phone application, and a cloud service with an artificial intelligence (AI) arrhythmia detection algorithm for AF detection. The specific aim of this proof-of-concept study was to test the feasibility of the entire sequence of operations from ECG recording to AI arrhythmia analysis and ultimately to final AF detection. METHODS Patients (n=159) with an AF (n=73) or sinus rhythm (n=86) were recruited from the emergency department. A single-lead heart belt ECG was recorded for 24 hours. Simultaneously registered 3-lead ECGs (Holter) served as the gold standard for the final rhythm diagnostics and as a reference device in a user experience survey with patients over 65 years of age (high-risk group). RESULTS The heart belt provided a high-quality ECG recording for visual interpretation resulting in 100% accuracy, sensitivity, and specificity of AF detection. The accuracy of AF detection with the automatic AI arrhythmia detection from the heart belt ECG recording was also high (97.5%), and the sensitivity and specificity were 100% and 95.4%, respectively. The correlation between the automatic estimated AF burden and the true AF burden from Holter recording was >0.99 with a mean burden error of 0.05 (SD 0.26) hours. The heart belt demonstrated good user experience and did not significantly interfere with the patient’s daily activities. The patients preferred the heart belt over Holter ECG for rhythm monitoring (85/110, 77% heart belt vs 77/109, 71% Holter, P=.049). CONCLUSIONS A consumer-grade, single-lead ECG heart belt provided good-quality ECG for rhythm diagnosis. The mHealth arrhythmia monitoring system, consisting of heart-belt ECG, a mobile phone application, and an automated AF detection achieved AF detection with high accuracy, sensitivity, and specificity. In addition, the mHealth arrhythmia monitoring system showed good user experience. CLINICALTRIAL ClinicalTrials.gov NCT03507335; https://clinicaltrials.gov/ct2/show/NCT03507335
- 26 April 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAutomatic Mobile Health Arrhythmia Monitoring for the Detection of Atrial Fibrillation: Prospective Feasibility, Accuracy, and User Experience Study (Preprint)
BACKGROUND Atrial fibrillation (AF) is the most common tachyarrhythmia and associated with a risk of stroke. The detection and diagnosis of AF represent a major clinical challenge due to AF’s asymptomatic and intermittent nature. Novel consumer-grade mobile health (mHealth) products with automatic arrhythmia detection could be an option for long-term electrocardiogram (ECG)-based rhythm monitoring and AF detection. OBJECTIVE We evaluated the feasibility and accuracy of a wearable automated mHealth arrhythmia monitoring system, including a consumer-grade, single-lead heart rate belt ECG device (heart belt), a mobile phone application, and a cloud service with an artificial intelligence (AI) arrhythmia detection algorithm for AF detection. The specific aim of this proof-of-concept study was to test the feasibility of the entire sequence of operations from ECG recording to AI arrhythmia analysis and ultimately to final AF detection. METHODS Patients (n=159) with an AF (n=73) or sinus rhythm (n=86) were recruited from the emergency department. A single-lead heart belt ECG was recorded for 24 hours. Simultaneously registered 3-lead ECGs (Holter) served as the gold standard for the final rhythm diagnostics and as a reference device in a user experience survey with patients over 65 years of age (high-risk group). RESULTS The heart belt provided a high-quality ECG recording for visual interpretation resulting in 100% accuracy, sensitivity, and specificity of AF detection. The accuracy of AF detection with the automatic AI arrhythmia detection from the heart belt ECG recording was also high (97.5%), and the sensitivity and specificity were 100% and 95.4%, respectively. The correlation between the automatic estimated AF burden and the true AF burden from Holter recording was >0.99 with a mean burden error of 0.05 (SD 0.26) hours. The heart belt demonstrated good user experience and did not significantly interfere with the patient’s daily activities. The patients preferred the heart belt over Holter ECG for rhythm monitoring (85/110, 77% heart belt vs 77/109, 71% Holter, P=.049). CONCLUSIONS A consumer-grade, single-lead ECG heart belt provided good-quality ECG for rhythm diagnosis. The mHealth arrhythmia monitoring system, consisting of heart-belt ECG, a mobile phone application, and an automated AF detection achieved AF detection with high accuracy, sensitivity, and specificity. In addition, the mHealth arrhythmia monitoring system showed good user experience. CLINICALTRIAL ClinicalTrials.gov NCT03507335; https://clinicaltrials.gov/ct2/show/NCT03507335
- Open Access
- 11 July 2017
- Published by Springer Nature in BMC Emergency Medicine
- Vol. 17 (1) , 1-10
Hypoxia and hypotension in patients intubated by physician staffed helicopter emergency medical services - a prospective observational multi-centre study
The effective treatment of airway compromise in trauma and non-trauma patients is important. Hypoxia and hypotension are predictors of negative patient outcomes and increased mortality, and may be important quality indicators of care provided by emergency medical services. Excluding cardiac arrests, critical trauma and non-trauma patients remain the two major groups to which helicopter emergency medical services (HEMS) are dispatched. Several studies describe the impact of pre-hospital hypoxia or hypotension on trauma patients, but few studies compare this in trauma and non-trauma patients. The primary aim was to describe the incidence of pre-hospital hypoxia and hypotension in the two groups receiving pre-hospital tracheal intubation (TI) by physician-staffed HEMS. Data were collected prospectively over a 12-month period, using a uniform Utstein-style airway template. Twenty-one physician-staffed HEMS in Europe and Australia participated. We compared peripheral oxygen saturation and systolic blood pressure before and after definitive airway management. Data were analysed using Cochran–Mantel–Haenszel methods and mixed-effects models. Eight hundred forty three trauma patients and 422 non-trauma patients receiving pre-hospital TI were included. Non-trauma patients had significantly lower predicted mean pre-intervention SpO2 compared to trauma patients. Post-intervention and admission SpO2 for the two groups were comparable. However, 3% in both groups were still hypoxic at admission. For hypotension, the differences between the groups were less prominent. However, 9% of trauma and 10% of non-trauma patients were still hypotensive at admission. There was no difference in short-term survival between trauma (97%) and non-trauma patients (95%). Decreased level of consciousness was the most frequent indication for TI, and was associated with increased survival to hospital (cOR 2.8; 95% CI: 1.4–5.4). Our results showed that non-trauma patients had a higher incidence of hypoxia before TI than trauma patients, but few were hypoxic at admission. The difference for hypotension was less prominent, but one in ten patients were still hypotensive at admission. Further investigations are needed to identify reversible causes that may be corrected to improve haemodynamics in the pre-hospital setting. We found high survival rates to hospital in both groups, suggesting that physician-staffed HEMS provide high-quality emergency airway management in trauma and non-trauma patients. Clinicaltrials.gov Identifier: NCT01502111 . Registered 22 Desember 2011.
- 11 July 2017
- Published by Springer Nature in BMC Emergency Medicine
- Vol. 17 (1) , 1-10
Open AccessHypoxia and hypotension in patients intubated by physician staffed helicopter emergency medical services - a prospective observational multi-centre study
The effective treatment of airway compromise in trauma and non-trauma patients is important. Hypoxia and hypotension are predictors of negative patient outcomes and increased mortality, and may be important quality indicators of care provided by emergency medical services. Excluding cardiac arrests, critical trauma and non-trauma patients remain the two major groups to which helicopter emergency medical services (HEMS) are dispatched. Several studies describe the impact of pre-hospital hypoxia or hypotension on trauma patients, but few studies compare this in trauma and non-trauma patients. The primary aim was to describe the incidence of pre-hospital hypoxia and hypotension in the two groups receiving pre-hospital tracheal intubation (TI) by physician-staffed HEMS. Data were collected prospectively over a 12-month period, using a uniform Utstein-style airway template. Twenty-one physician-staffed HEMS in Europe and Australia participated. We compared peripheral oxygen saturation and systolic blood pressure before and after definitive airway management. Data were analysed using Cochran–Mantel–Haenszel methods and mixed-effects models. Eight hundred forty three trauma patients and 422 non-trauma patients receiving pre-hospital TI were included. Non-trauma patients had significantly lower predicted mean pre-intervention SpO2 compared to trauma patients. Post-intervention and admission SpO2 for the two groups were comparable. However, 3% in both groups were still hypoxic at admission. For hypotension, the differences between the groups were less prominent. However, 9% of trauma and 10% of non-trauma patients were still hypotensive at admission. There was no difference in short-term survival between trauma (97%) and non-trauma patients (95%). Decreased level of consciousness was the most frequent indication for TI, and was associated with increased survival to hospital (cOR 2.8; 95% CI: 1.4–5.4). Our results showed that non-trauma patients had a higher incidence of hypoxia before TI than trauma patients, but few were hypoxic at admission. The difference for hypotension was less prominent, but one in ten patients were still hypotensive at admission. Further investigations are needed to identify reversible causes that may be corrected to improve haemodynamics in the pre-hospital setting. We found high survival rates to hospital in both groups, suggesting that physician-staffed HEMS provide high-quality emergency airway management in trauma and non-trauma patients. Clinicaltrials.gov Identifier: NCT01502111 . Registered 22 Desember 2011.