Sarmad Mehrdad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sarmad Mehrdad has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Seyed Farokh Atashzar
Department of Electrical and Computer Engineering, New York University (NYU), USA
4 shared publications - Jinghui Yang
University of Hartford, West Hartford, CT
2 shared publications - Rory O'KEeffe
Department of Electrical and Computer Engineering, New York University (NYU), New York, NY, USA
2 shared publications - Seyed Yahya Shirazi
Swartz Center for Computational Neuroscience, Institute for Neural Computation, University of California San Diego, La Jolla, CA, United States
2 shared publications - Smita Rao
Department of Physical Therapy, New York University, New York, New York
2 shared publications Aaron M. Johnson
NYU Grossman School of Medicine
1 shared publication
Latest Publications
- Open Access
- 3 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 2953-2963
Lower-Limb Non-Parametric Functional Muscle Network: Test-Retest Reliability Analysis
Objective : Functional muscle network analysis has attracted a great deal of interest in recent years, promising high sensitivity to changes of intermuscular synchronicity, studied mostly for healthy subjects and recently for patients living with neurological conditions (e.g., those caused by stroke). Despite the promising results, the between- and within-session reliability of the functional muscle network measures are yet to be established. Here, for the first time, we question and evaluate the test-retest reliability of non-parametric lower-limb functional muscle networks for controlled and lightly-controlled tasks, i.e., sit-to-stand, and over-the-ground walking, respectively, in healthy subjects. Method : Fifteen subjects (eight females) were included over two sessions on two different days. The muscle activity was recorded using 14 surface electromyography (sEMG) sensors. The intraclass correlation coefficient (ICC) of the within-session and between-session trials was quantified for the various network metrics, including degree and weighted clustering coefficient. In order to compare with common classical sEMG measures, the reliabilities of the root mean square (RMS) of sEMG and the median frequency (MDF) of sEMG were also calculated. Results : The ICC analysis revealed superior between-session reliability for muscle networks, with statistically significant differences when compared to classic measures. Conclusion and Significance : This paper proposed that the topographical metrics generated from functional muscle network can be reliably used for multi-session observations securing high reliability for quantifying the distribution of synergistic intermuscular synchronicities of both controlled and lightly controlled lower limb tasks. In addition, the low number of sessions required by the topographical network metrics to reach reliable measurements indicates the potential as biomarkers during rehabilitation.
- 3 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 2953-2963
Open AccessLower-Limb Non-Parametric Functional Muscle Network: Test-Retest Reliability Analysis
Objective : Functional muscle network analysis has attracted a great deal of interest in recent years, promising high sensitivity to changes of intermuscular synchronicity, studied mostly for healthy subjects and recently for patients living with neurological conditions (e.g., those caused by stroke). Despite the promising results, the between- and within-session reliability of the functional muscle network measures are yet to be established. Here, for the first time, we question and evaluate the test-retest reliability of non-parametric lower-limb functional muscle networks for controlled and lightly-controlled tasks, i.e., sit-to-stand, and over-the-ground walking, respectively, in healthy subjects. Method : Fifteen subjects (eight females) were included over two sessions on two different days. The muscle activity was recorded using 14 surface electromyography (sEMG) sensors. The intraclass correlation coefficient (ICC) of the within-session and between-session trials was quantified for the various network metrics, including degree and weighted clustering coefficient. In order to compare with common classical sEMG measures, the reliabilities of the root mean square (RMS) of sEMG and the median frequency (MDF) of sEMG were also calculated. Results : The ICC analysis revealed superior between-session reliability for muscle networks, with statistically significant differences when compared to classic measures. Conclusion and Significance : This paper proposed that the topographical metrics generated from functional muscle network can be reliably used for multi-session observations securing high reliability for quantifying the distribution of synergistic intermuscular synchronicities of both controlled and lightly controlled lower limb tasks. In addition, the low number of sessions required by the topographical network metrics to reach reliable measurements indicates the potential as biomarkers during rehabilitation.
- 20 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27 (4) , 2105-2116
Non-Parametric Functional Muscle Network as a Robust Biomarker of Fatigue
Characterization of fatigue using surface electromyography (sEMG) data has been motivated for rehabilitation and injury-preventative technologies. Current sEMG-based models of fatigue are limited due to (a) linear and parametric assumptions, (b) lack of a holistic neurophysiological view, and (c) complex and heterogeneous responses. This paper proposes and validates a data-driven non-parametric functional muscle network analysis to reliably characterize fatigue-related changes in synergistic muscle coordination and distribution of neural drive at the peripheral level. The proposed approach was tested on data collected in this study from the lower extremities of 26 asymptomatic volunteers (13 subjects were assigned to the fatigue intervention group, and 13 age/gender-matched subjects were assigned to the control group). Volitional fatigue was induced in the intervention group by moderate-intensity unilateral leg press exercises. The proposed non-parametric functional muscle network demonstrated a consistent decrease in connectivity after the fatigue intervention, as indicated by network degree, weighted clustering coefficient (WCC), and global efficiency. The graph metrics displayed consistent and significant decreases at the group level, individual subject level, and individual muscle level. For the first time, this paper proposed a non-parametric functional muscle network and highlighted the corresponding potential as a sensitive biomarker of fatigue with superior performance to conventional spectrotemporal measures.
- 20 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27 (4) , 2105-2116
Non-Parametric Functional Muscle Network as a Robust Biomarker of Fatigue
Characterization of fatigue using surface electromyography (sEMG) data has been motivated for rehabilitation and injury-preventative technologies. Current sEMG-based models of fatigue are limited due to (a) linear and parametric assumptions, (b) lack of a holistic neurophysiological view, and (c) complex and heterogeneous responses. This paper proposes and validates a data-driven non-parametric functional muscle network analysis to reliably characterize fatigue-related changes in synergistic muscle coordination and distribution of neural drive at the peripheral level. The proposed approach was tested on data collected in this study from the lower extremities of 26 asymptomatic volunteers (13 subjects were assigned to the fatigue intervention group, and 13 age/gender-matched subjects were assigned to the control group). Volitional fatigue was induced in the intervention group by moderate-intensity unilateral leg press exercises. The proposed non-parametric functional muscle network demonstrated a consistent decrease in connectivity after the fatigue intervention, as indicated by network degree, weighted clustering coefficient (WCC), and global efficiency. The graph metrics displayed consistent and significant decreases at the group level, individual subject level, and individual muscle level. For the first time, this paper proposed a non-parametric functional muscle network and highlighted the corresponding potential as a sensitive biomarker of fatigue with superior performance to conventional spectrotemporal measures.
- Open Access
Characterization of Cervical-Cranial Muscle Network in Correlation with Vocal Features
Objective evaluation of physiological responses using non-invasive methods has attracted great interest regarding the assessment of vocal performance and disorders. This paper, for the first time, demonstrates that the topographical features of the cervical-cranial intermuscular coherence network generated using surface electromyography (sEMG) have a strong potential for detecting subtle changes in vocal performance. For this purpose, in this paper, 12 sEMG signals were collected from six cervical and cranial muscles bilaterally. Data were collected from four subjects without a history of a voice disorder performing a series of vocal tasks. The vocal tasks were varied phonation (an /a/ sustained for the maximal duration with combinations of two levels of loudness and two levels of pitch), a pitch glide from low to high, singing a familiar song, spontaneous speech, and reading with different loudness levels. The varied phonation tasks showed the median degree, and weighted clustering coefficient of the coherence-based intermuscular network ascends monotonically, with a high effect size (| r rb | = 0.52). The set of tasks, including pitch glide, singing, and speech, was significantly distinguishable using the network features as both degree and weighted clustering coefficient had a very high effect size (| r rb | > 0.83) across these tasks. Also, pitch glide has the highest degree and weighted clustering coefficient among all tasks (degree > 0.6, weighted clustering coefficient > 0.6). Spectrotemporal features performed far less effective than the proposed functional muscle network metrics to differentiate the vocal tasks. The highest effect size for spectrotemporal features was only | r rb | = 0.19. In this paper, for the first time, the power of a cervical-cranial muscle network has been demonstrated as a neurophysiological window to vocal performance. The results also shed light on the tasks with the highest network involvement, which may be potentially used in monitoring vocal disorders and tracking rehabilitation progress.
Open AccessCharacterization of Cervical-Cranial Muscle Network in Correlation with Vocal Features
Objective evaluation of physiological responses using non-invasive methods has attracted great interest regarding the assessment of vocal performance and disorders. This paper, for the first time, demonstrates that the topographical features of the cervical-cranial intermuscular coherence network generated using surface electromyography (sEMG) have a strong potential for detecting subtle changes in vocal performance. For this purpose, in this paper, 12 sEMG signals were collected from six cervical and cranial muscles bilaterally. Data were collected from four subjects without a history of a voice disorder performing a series of vocal tasks. The vocal tasks were varied phonation (an /a/ sustained for the maximal duration with combinations of two levels of loudness and two levels of pitch), a pitch glide from low to high, singing a familiar song, spontaneous speech, and reading with different loudness levels. The varied phonation tasks showed the median degree, and weighted clustering coefficient of the coherence-based intermuscular network ascends monotonically, with a high effect size (| r rb | = 0.52). The set of tasks, including pitch glide, singing, and speech, was significantly distinguishable using the network features as both degree and weighted clustering coefficient had a very high effect size (| r rb | > 0.83) across these tasks. Also, pitch glide has the highest degree and weighted clustering coefficient among all tasks (degree > 0.6, weighted clustering coefficient > 0.6). Spectrotemporal features performed far less effective than the proposed functional muscle network metrics to differentiate the vocal tasks. The highest effect size for spectrotemporal features was only | r rb | = 0.19. In this paper, for the first time, the power of a cervical-cranial muscle network has been demonstrated as a neurophysiological window to vocal performance. The results also shed light on the tasks with the highest network involvement, which may be potentially used in monitoring vocal disorders and tracking rehabilitation progress.
- Open Access
- 28 December 2020
- Published by MDPI AG in Applied Sciences
- Vol. 11 (1) , 209
Review of Advanced Medical Telerobots
The advent of telerobotic systems has revolutionized various aspects of the industry and human life. This technology is designed to augment human sensorimotor capabilities to extend them beyond natural competence. Classic examples are space and underwater applications when distance and access are the two major physical barriers to be combated with this technology. In modern examples, telerobotic systems have been used in several clinical applications, including teleoperated surgery and telerehabilitation. In this regard, there has been a significant amount of research and development due to the major benefits in terms of medical outcomes. Recently telerobotic systems are combined with advanced artificial intelligence modules to better share the agency with the operator and open new doors of medical automation. In this review paper, we have provided a comprehensive analysis of the literature considering various topologies of telerobotic systems in the medical domain while shedding light on different levels of autonomy for this technology, starting from direct control, going up to command-tracking autonomous telerobots. Existing challenges, including instrumentation, transparency, autonomy, stochastic communication delays, and stability, in addition to the current direction of research related to benefit in telemedicine and medical automation, and future vision of this technology, are discussed in this review paper.
- 28 December 2020
- Published by MDPI AG in Applied Sciences
- Vol. 11 (1) , 209
Open AccessReview of Advanced Medical Telerobots
The advent of telerobotic systems has revolutionized various aspects of the industry and human life. This technology is designed to augment human sensorimotor capabilities to extend them beyond natural competence. Classic examples are space and underwater applications when distance and access are the two major physical barriers to be combated with this technology. In modern examples, telerobotic systems have been used in several clinical applications, including teleoperated surgery and telerehabilitation. In this regard, there has been a significant amount of research and development due to the major benefits in terms of medical outcomes. Recently telerobotic systems are combined with advanced artificial intelligence modules to better share the agency with the operator and open new doors of medical automation. In this review paper, we have provided a comprehensive analysis of the literature considering various topologies of telerobotic systems in the medical domain while shedding light on different levels of autonomy for this technology, starting from direct control, going up to command-tracking autonomous telerobots. Existing challenges, including instrumentation, transparency, autonomy, stochastic communication delays, and stability, in addition to the current direction of research related to benefit in telemedicine and medical automation, and future vision of this technology, are discussed in this review paper.