Steven R. Jefferts
Research Subjects
Steven R. Jefferts has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Alexandra B. Artusio-Glimpse
National Institute of Standards and Technology
2 shared publications - Brian C. Sawyer
Georgia Tech Research Institute
2 shared publications - Christopher L. Holloway
National Institute of Standards and Technology
2 shared publications - Eric Imhof
Northrop Grumman Mission Systems
2 shared publications - Matthew T. Simons
National Institute of Standards and Technology
2 shared publications - Robert Wyllie
Georgia Tech Research Institute, Atlanta, GA 30332, USA
2 shared publications
Latest Publications
- Open Access
- 25 August 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134 (8)
Investigating electromagnetically induced transparency spectral lineshape distortion due to non-uniform fields in Rydberg-atom electrometry
We investigate the effects of spatially non-uniform radio-frequency electric (E) field amplitudes on the spectral line shapes of electromagnetically induced transparency (EIT) signals in Rydberg atomic systems used in electrometry (i.e., the metrology of E-field strengths). Spatially non-uniform fields distort the EIT spectra from that of an ideal case, and understanding this distortion is important in the development of Rydberg atom-based sensors, as these distortions can limit accuracy and sensitivity. To characterize this distortion, we present a model that approximates the atom vapor as multi-layered media and then uses Beer’s law to combine the absorption through its many discrete thin segments. We present a set of expected line distortions caused by various RF electric-field distributions found in practice. This provides an intuitive diagnostic tool for experiments. We compare this model to measured experimental atomic spectra in both two-photon and three-photon excitation schemes in the presence of non-uniform radio-frequency fields. We show that we can accurately model and reproduce the EIT lineshape distortion observed in these experimental data.
- 25 August 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134 (8)
Open AccessInvestigating electromagnetically induced transparency spectral lineshape distortion due to non-uniform fields in Rydberg-atom electrometry
We investigate the effects of spatially non-uniform radio-frequency electric (E) field amplitudes on the spectral line shapes of electromagnetically induced transparency (EIT) signals in Rydberg atomic systems used in electrometry (i.e., the metrology of E-field strengths). Spatially non-uniform fields distort the EIT spectra from that of an ideal case, and understanding this distortion is important in the development of Rydberg atom-based sensors, as these distortions can limit accuracy and sensitivity. To characterize this distortion, we present a model that approximates the atom vapor as multi-layered media and then uses Beer’s law to combine the absorption through its many discrete thin segments. We present a set of expected line distortions caused by various RF electric-field distributions found in practice. This provides an intuitive diagnostic tool for experiments. We compare this model to measured experimental atomic spectra in both two-photon and three-photon excitation schemes in the presence of non-uniform radio-frequency fields. We show that we can accurately model and reproduce the EIT lineshape distortion observed in these experimental data.
- 24 September 2021
- Published by American Physical Society (APS) in Physical Review A
- Vol. 104 (3) , 032824
Continuous radio-frequency electric-field detection through adjacent Rydberg resonance tuning
We demonstrate the use of multiple atomic-level Rydberg-atom schemes for continuous frequency detection of radio-frequency (RF) fields. Resonant detection of RF fields by electromagnetically induced transparency and Autler-Townes (AT) splitting in Rydberg atoms is typically limited to frequencies within the narrow bandwidth of a Rydberg transition. By applying a second field resonant with an adjacent Rydberg transition, far-detuned fields can be detected through a two-photon resonance AT splitting. This two-photon AT splitting method is several orders of magnitude more sensitive than off-resonant detection using the Stark shift. We present the results of various experimental configurations and a theoretical analysis to illustrate the effectiveness of this multiple level scheme. These results show that this approach allows for the detection of frequencies in a continuous band between resonances with adjacent Rydberg states.
- 24 September 2021
- Published by American Physical Society (APS) in Physical Review A
- Vol. 104 (3) , 032824
Continuous radio-frequency electric-field detection through adjacent Rydberg resonance tuning
We demonstrate the use of multiple atomic-level Rydberg-atom schemes for continuous frequency detection of radio-frequency (RF) fields. Resonant detection of RF fields by electromagnetically induced transparency and Autler-Townes (AT) splitting in Rydberg atoms is typically limited to frequencies within the narrow bandwidth of a Rydberg transition. By applying a second field resonant with an adjacent Rydberg transition, far-detuned fields can be detected through a two-photon resonance AT splitting. This two-photon AT splitting method is several orders of magnitude more sensitive than off-resonant detection using the Stark shift. We present the results of various experimental configurations and a theoretical analysis to illustrate the effectiveness of this multiple level scheme. These results show that this approach allows for the detection of frequencies in a continuous band between resonances with adjacent Rydberg states.
- 13 September 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6673, 667303
Optical frequency standards based on mercury and aluminum ions
Single-trapped-ion frequency standards based on a 282 nm transition in 199Hg+ and on a 267 nm transition in 27Al+ have been developed at NIST over the past several years. Their frequencies are measured relative to each other and to the NIST primary frequency standard, the NIST-F1 cesium fountain, by means of a self-referenced femtosecond laser frequency comb. Both ion standards have demonstrated instabilities and inaccuracies of less than 1 × 10-16.
- 13 September 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6673, 667303
Optical frequency standards based on mercury and aluminum ions
Single-trapped-ion frequency standards based on a 282 nm transition in 199Hg+ and on a 267 nm transition in 27Al+ have been developed at NIST over the past several years. Their frequencies are measured relative to each other and to the NIST primary frequency standard, the NIST-F1 cesium fountain, by means of a self-referenced femtosecond laser frequency comb. Both ion standards have demonstrated instabilities and inaccuracies of less than 1 × 10-16.
- Open Access
- 8 July 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10756787,p. 1072-1075
PARCS magnetic field measurement: low frequency majorana transitions and magnetic field inhomogeneity
Knowledge of the magnetic field is required to determine the quadratic Zeeman bias of a cesium frequency standard. The small magnetic fields (C-field) used in PARCS (PARCS is the primary atomic reference clock in space project), may have sufficient inhomogeneity that it is not practical to measure the field by observing Ramsey fringes on a field-sensitive hyperfine line at low launch velocities. An alternative method is to observe low-frequency (Majorana) transitions among the Zeeman sublevels. However, this method does not average the C-field in the same way as Ramsey excitation. We have computed the error incurred in using this method for some simple models of inhomogeneity. We have then estimated the field homogeneity requirements needed for this method to produce adequate results. Experiments with the NIST cesium fountain are in qualitative agreement.
- 8 July 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10756787,p. 1072-1075
Open AccessPARCS magnetic field measurement: low frequency majorana transitions and magnetic field inhomogeneity
Knowledge of the magnetic field is required to determine the quadratic Zeeman bias of a cesium frequency standard. The small magnetic fields (C-field) used in PARCS (PARCS is the primary atomic reference clock in space project), may have sufficient inhomogeneity that it is not practical to measure the field by observing Ramsey fringes on a field-sensitive hyperfine line at low launch velocities. An alternative method is to observe low-frequency (Majorana) transitions among the Zeeman sublevels. However, this method does not average the C-field in the same way as Ramsey excitation. We have computed the error incurred in using this method for some simple models of inhomogeneity. We have then estimated the field homogeneity requirements needed for this method to produce adequate results. Experiments with the NIST cesium fountain are in qualitative agreement.