THTerranna Haxton

Terranna Haxton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Terranna Haxton has a total of 32 co-authors. Here are the top co-authors by number of shared publications:

  • Regan Murray

    National Homeland Security Research Center, United States Environmental Protection Agency, 26. W. Martin Luther King Drive (MS 163), Cincinnati, OH 45268

    4 shared publications
  • David Hart

    Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2 shared publications
  • Katherine A. Klise

    Principal Member of Technical Staff, Sandia National Laboratories, Energy Water Systems Integration, P.O. Box 5800, Albuquerque, NM 87185

    2 shared publications
  • Katherine A. Klise

    Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2 shared publications
  • Katherine Klise

    Principal Member of Technical Staff, Sandia National Laboratories, Energy Water Systems Integration, P.O. Box 5800, Albuquerque, NM 87185

    2 shared publications
  • Regan Murray

    Division Director, United States Environmental Protection Agency, Office of Research and Development, 26 W. Martin Luther King Dr., Cincinnati, OH 45268

    2 shared publications

Latest Publications

  • Resilience Analysis and Emergency Response Evaluation for Drinking Water Systems

    by Lucinda‐Joi Chu‐Ketterer, William E. Platten, Sarah Bolenbaugh, Terranna Haxton


  • Performance and Resilience Analysis of a New York Drinking Water System to Localized and System-Wide Emergencies

    by Lucinda-Joi Chu-Ketterer, Regan Murray, Patrick Hassett, Josh Kogan, Katherine Klise, Terranna Haxton

    Drinking water utilities are vulnerable to both human-caused and natural disasters that can impact the system infrastructure and the delivery of potable water to consumers. Analyzing system performance and resilience can help utilities identify areas of high risk or concern, understand the impacts on consumers, and evaluate response actions during disasters. In this case study, the Water Network Tool for Resilience (WNTR) was used to investigate the performance and resilience of a drinking water system in New York during increased demands due to firefighting, pipe damage, and loss of the source water emergencies. This case study introduced a new combined performance index (CPI) resilience metric, which served to quantify system resilience as a ratio of system performance during an emergency to normal operations. The results revealed that this drinking water system was able to maintain service to most of the consumers during these emergencies due to high redundancy within the system, and conservation efforts extended water service for an additional 20 h. The analysis in this paper can be used by other drinking water utilities to understand their vulnerabilities and evaluate resilience-improving actions in similar disaster scenarios.


  • Resilience Analysis of Potable Water Service after Power Outages in the U.S. Virgin Islands

    by Katherine Klise, Rachel Moglen, Joseph Hogge, Daniel Eisenberg, Terranna Haxton

    The two Category-5 hurricanes that impacted the United States Virgin Islands in 2017 exposed critical infrastructure vulnerabilities that must be addressed. While the drinking water utility has first-hand knowledge about how the hurricanes affected their systems, the use of modeling and simulation tools can provide additional insight to aid investment planning and preparedness. This paper provides a case study on resilience analysis for the island’s potable water systems subject to long term power outages. Power outage scenarios help quantify differences in water delivery, water quality, and water quantity during and after the disruption. The analysis helps illustrate important differences in system operations and recovery time across the islands. Results from this case study can be used to better understand how the system might behave during future disruptions, provide justification for investment, and provide recommendations to increase resilience of the system. The analysis framework can also be used by other utilities to explore vulnerability to long term power outages.


  • Case Study Applications of Water Network Tool for Resilience (WNTR)

    by Terra Haxton

    Water distribution systems are among the most critical civil infrastructure and must be prepared to withstand or quickly recover from any disrupt |


  • Open Access

    Water network tool for resilience

    by Lucinda-Joi Chu-Ketterer, Jonathan Burkhardt, Katherine Klise, Terranna Haxton, Juneseok Lee, Jonathan Keck

    *Corresponding author: haxton.terra@epa.gov© 2022 The Editors2022


  • Evaluating Manual Sampling Locations for Regulatory and Emergency Response

    by Terranna Haxton, Katherine A. Klise, Daniel Laky, Regan Murray, Carl D. Laird, Jonathan B. Burkhardt

    Drinking water systems commonly use manual or grab sampling to monitor water quality, identify or confirm issues, and verify that corrective or emergency response actions have been effective. In this paper, the effectiveness of regulatory sampling locations for emergency response is explored. An optimization formulation based on the literature was used to identify manual sampling locations to maximize overall nodal coverage of the system. Results showed that sampling locations could be effective in confirming incidents for which they were not designed. When evaluating sampling locations optimized for emergency response against regulatory scenarios, the average performance was reduced by 3%–4%, while using optimized regulatory sampling locations for emergency response reduced performance by 7%–10%. Secondary constraints were also included in the formulation to ensure geographical and water age diversity with minimal impact on the performance. This work highlighted that regulatory sampling locations provide value in responding to an emergency for these networks.


  • Open Access

    Testing Contamination Source Identification Methods for Water Distribution Networks

    by Arpan Seth, Katherine A. Klise, John D. Siirola, Terranna Haxton, Carl D. Laird

    In the event of contamination in a water distribution network (WDN), source identification (SI) methods that analyze sensor data can be used to identify the source location(s). Knowledge of the source location and characteristics are important to inform contamination control and cleanup operations. Various SI strategies that have been developed by researchers differ in their underlying assumptions and solution techniques. The following manuscript presents a systematic procedure for testing and evaluating SI methods. The performance of these SI methods is affected by various factors including the size of WDN model, measurement error, modeling error, time and number of contaminant injections, and time and number of measurements. This paper includes test cases that vary these factors and evaluates three SI methods on the basis of accuracy and specificity. The tests are used to review and compare these different SI methods, highlighting their strengths in handling various identification scenarios. The...


  • Examining the Application of Modeling Tools to Identify Effective Flushing Locations

    by T. Haxton, R. Murray, K. Klise

    If contamination is detected in a water distribution system, water utilities will need to rapidly determine an effective way to mitigate potential public health and economic consequences. Water utilities could use modeling tools to quickly evaluate potential response options and support effective decision-making. EPA is developing a suite of water security tools that help provide the information necessary to make good decisions regarding consequence management resulting in the minimization of further human exposure to contaminants, and the maximization of the effectiveness of intervention strategies. These tools assist in the evaluation of multiple response actions in order to select the most beneficial consequence management strategy. For example, a tool could evaluate the end results of implementing different response actions, such as an official "Do Not Drink" order by a public health department, or a decision by a water utility to implement hydraulic changes that isolate a contaminant and flush it from the system. One of the modeling tools being developed combines hydraulic and water quality modeling with optimization to assist in the identification of effective hydrant locations to flush in order to remove contaminated water. To evaluate the application of this tool, a feasibility and sensitivity study was completed using real-world water distribution networks. Since water utilities are interested in mitigating both public heath and economic consequences, different objectives were utilized as part of the optimization process. The results from different objectives were examined for similarities in the hydrant locations as well as the objective values. In addition, various other parameters which influence the effectiveness of the response strategy were examined, such as the delay time associated with the response action, the number of hydrants flushed, and the length of time that a hydrant is open. As part of the evaluation, the optimal flushing locations were compared against results from a study that enumerated all possible flushing locations.


  • Flushing under Source Uncertainties

    by Terranna Haxton, James G. Uber

    Upon determination of a possible contamination threat in a water distribution network, a variety of response actions (e.g., public notification and operational changes) can be pursued in order to minimize public health and economic impacts and ultimately return the utility to normal operations. Flushing is a relatively common operational response option employed by utilities to address water quality concerns. Previously, an optimal hydraulic response tool was developed to help identify the best hydrant locations to flush. However, in order to apply this tool the contaminant injection location needs to be known. In previous research efforts, either the injection location was assumed to be known, or a sensor coverage map, which displays all contamination incidents potentially detected by a sensor, was employed to identify all possible injection locations. While the flushing locations selected for a known source location were effective in reducing impacts, the locations selected based on sensor coverage maps were not as effective. Therefore, in this study, a source location algorithm based on an event backtracking analysis is used to identify the most likely source locations. An example network model and multiple injection locations are used to evaluate the effectiveness of this approach. In addition, the reduction in impacts between the three different source identification approaches (i.e., known, sensor coverage map, backtracking) were compared. Overall, knowing the contaminant injection location greatly influences the effectiveness of the flushing response. For this study, the smaller amount of possible source locations, the greater the reduction in impacts. If only one source location is identified, the impact reduction could be as high as 98%. However, when 18 possible sources were identified from the sensor coverage map approach, only a reduction of 2% was achieved.


  • Assessing the Impact of Population Distribution on Sensor Network Design

    by Rakesh Bahadur, William B. Samuels, Robert Janke, Terra Baranowski Haxton

    This study examines the impact of dynamic population data on sensor network design. The primary driving force for managing and regulating distribution systems is to provide potable drinking water. Water distribution systems are inherently vulnerable to accidental or intentional contamination because of their distributed geography and numerous access points. The objective of a contamination warning system (CWS) is to minimize potential economic and public health impacts resulting from either an accidental release (such as a chemical spill) or a deliberate act of terrorism. Accidental or malicious introduction of a contaminant into water distribution systems could potentially have severe health effects on a population. Such intrusions can potentially be detected by deploying a number of sensing devices into the water distribution system. Optimal sensor placement needs to reflect variation in the timing of a contamination event and the distribution of the affected population. Population varies temporally (day versus night time) and spatially (different areas within city). The temporal population variation is not currently accounted for in sensor design studies. Previous studies of optimal sensor placement to support CWS design have considered only spatial variability using U.S. Census data or demand-based population models. This study included temporal variability by analyzing both day and night time population data. This was accomplished by using multiple population data sources such as LandScan and U.S. Census as input to the Threat Ensemble Vulnerability Assessment Sensor Placement Optimization Tool (TEVA-SPOT). This study showed that the temporal variation in population has a significant impact on sensor network design.