Yushuang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yushuang Liu has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Wenfeng Hai
Inner Mongolia Key Laboratory of Solid State Chemistry for Battery, Inner Mongolia Engineering Research Center of Lithium-Sulfur Battery Energy Storage, College of Chemistry and Materials Science, Inner Mongolia Minzu University, Tongliao, People’s Republic of China
10 shared publications Mingxuan Wang
Inner Mongolia Key Laboratory of Solid State Chemistry for Battery, Inner Mongolia Engineering Research Center of Lithium-Sulfur Battery Energy Storage, College of Chemistry and Materials Science, Inner Mongolia Minzu University, Tongliao 028000, People's Republic of China
6 shared publicationsGuiqi Zhou
Inner Mongolia Key Laboratory of Solid State Chemistry for Battery, Inner Mongolia Engineering Research Center of Lithium-Sulfur Battery Energy Storage, College of Chemistry and Materials Science, Inner Mongolia Minzu University, Tongliao, People’s Republic of China
5 shared publicationsYing Zhang
Inner Mongolia Key Laboratory of Solid State Chemistry for Battery, Inner Mongolia Engineering Research Center of Lithium−Sulfur Battery Energy Storage, College of Chemistry and Materials Science
5 shared publicationsFurong Chen
Inner Mongolia Key Laboratory of Carbon Nanomaterials, Nano Innovation Institute (NII), College of Chemistry and Materials Science, Inner Mongolia Minzu University, Tongliao, 028000, China
4 shared publicationsChunyu Du
Inner Mongolia Key Laboratory of Solid State Chemistry for Battery, Inner Mongolia Engineering Research Center of Lithium-Sulfur Battery Energy Storage, College of Chemistry and Materials Science, Inner Mongolia Minzu University, Tongliao, People’s Republic of China
3 shared publications
Latest Publications
- 7 November 2026
- Published by Springer Nature in Microchimica Acta
- Vol. 193 (12) , 788
Field-effect transistor biosensors for biomedical applications: material platforms, interfacial engineering, and translational challenges
- 7 November 2026
- Published by Springer Nature in Microchimica Acta
- Vol. 193 (12) , 788
Field-effect transistor biosensors for biomedical applications: material platforms, interfacial engineering, and translational challenges
- 15 June 2026
- Published by Springer Nature in Microchimica Acta
- Vol. 193 (7)
Micromotor-assisted graphene field-effect transistor for label-free and ultrasensitive detection of SARS-CoV-2 in complex matrices
Outbreaks of infectious diseases pose a major challenge to public health and social development, creating an urgent need for rapid, sensitive, and field-deployable diagnostic platforms. We developed a label-free sensing strategy for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by integrating antibody-functionalized Fe3O4@TiO2@MnO2 magnetic micromotors with a graphene field-effect transistor (GFET). The micromotors exhibited self-propulsion in H2O2 solution due to catalytic oxygen generation, which enhanced target capture and enrichment efficiency. After magnetic separation, the collected micromotor-target complexes were directly analyzed by GFET for quantitative detection. Under optimized conditions, the platform showed a wide linear response and achieved an ultralow limit of detection of ag/mL in PBS. The sensing system also maintained reliable analytical performance in complex matrices, with detection limits of 37.5 ag/mL in human serum and 19.1 ag/mL in soil solution. In addition, the platform exhibited excellent reproducibility and favorable reusability. These results demonstrate that the proposed micromotor-assisted GFET platform provides a sensitive and robust approach for SARS-CoV-2 detection and holds considerable promise for on-site determination of infectious pathogens in complex real-sample environments.
- 15 June 2026
- Published by Springer Nature in Microchimica Acta
- Vol. 193 (7)
Micromotor-assisted graphene field-effect transistor for label-free and ultrasensitive detection of SARS-CoV-2 in complex matrices
Outbreaks of infectious diseases pose a major challenge to public health and social development, creating an urgent need for rapid, sensitive, and field-deployable diagnostic platforms. We developed a label-free sensing strategy for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by integrating antibody-functionalized Fe3O4@TiO2@MnO2 magnetic micromotors with a graphene field-effect transistor (GFET). The micromotors exhibited self-propulsion in H2O2 solution due to catalytic oxygen generation, which enhanced target capture and enrichment efficiency. After magnetic separation, the collected micromotor-target complexes were directly analyzed by GFET for quantitative detection. Under optimized conditions, the platform showed a wide linear response and achieved an ultralow limit of detection of ag/mL in PBS. The sensing system also maintained reliable analytical performance in complex matrices, with detection limits of 37.5 ag/mL in human serum and 19.1 ag/mL in soil solution. In addition, the platform exhibited excellent reproducibility and favorable reusability. These results demonstrate that the proposed micromotor-assisted GFET platform provides a sensitive and robust approach for SARS-CoV-2 detection and holds considerable promise for on-site determination of infectious pathogens in complex real-sample environments.
- 3 April 2026
- Published by Elsevier in Bioelectrochemistry
- Vol. 171, 109299
A graphene FET biosensing platform integrated with Fe₃O₄@SiO₂@Ce-Zr bimetallic MOFs for rapid SARS-CoV-2 detection
- 3 April 2026
- Published by Elsevier in Bioelectrochemistry
- Vol. 171, 109299
A graphene FET biosensing platform integrated with Fe₃O₄@SiO₂@Ce-Zr bimetallic MOFs for rapid SARS-CoV-2 detection
- 29 October 2025
- Published by American Chemical Society (ACS) in ACS Infectious Diseases
- Vol. 11 (11) , 3106-3114
High-Sensitivity Detection of Infectious Disease via Fe 3 O 4 @UiO-66-NH 2 Combined with a Graphene Field-Effect Transistor
Infectious diseases remain a serious global health threat due to their high transmissibility and mortality, highlighting the urgent need for sensitive and rapid diagnostic tools to enable early detection and effective intervention. Herein, we report an ultrasensitive biosensing platform that integrates Fe3O4@UiO-66-NH2 nanocomposites with a graphene field-effect transistor (GFET) for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The nanocomposites were conjugated with antibodies against SARS-CoV-2, enabling selective capture of viral particles from complex biological matrices. Following magnetic enrichment, the GFET sensor was employed for signal transduction and quantitative analysis. The platform demonstrated a broad dynamic range (1 ag·mL-1 to 10 ng·mL-1) with an exceptionally low detection limit of 1.98 ag·mL-1. Furthermore, successful detection of SARS-CoV-2 antigens in serum samples highlights its potential for point-of-care and real-time diagnostic.
- 29 October 2025
- Published by American Chemical Society (ACS) in ACS Infectious Diseases
- Vol. 11 (11) , 3106-3114
High-Sensitivity Detection of Infectious Disease via Fe 3 O 4 @UiO-66-NH 2 Combined with a Graphene Field-Effect Transistor
Infectious diseases remain a serious global health threat due to their high transmissibility and mortality, highlighting the urgent need for sensitive and rapid diagnostic tools to enable early detection and effective intervention. Herein, we report an ultrasensitive biosensing platform that integrates Fe3O4@UiO-66-NH2 nanocomposites with a graphene field-effect transistor (GFET) for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The nanocomposites were conjugated with antibodies against SARS-CoV-2, enabling selective capture of viral particles from complex biological matrices. Following magnetic enrichment, the GFET sensor was employed for signal transduction and quantitative analysis. The platform demonstrated a broad dynamic range (1 ag·mL-1 to 10 ng·mL-1) with an exceptionally low detection limit of 1.98 ag·mL-1. Furthermore, successful detection of SARS-CoV-2 antigens in serum samples highlights its potential for point-of-care and real-time diagnostic.
- 6 March 2025
- Published by Elsevier in Bioelectrochemistry
- Vol. 165, 108951
Magnetic MOF-based sensing platform integrated with graphene field-effect transistors for ultrasensitive detection of infectious disease
- 6 March 2025
- Published by Elsevier in Bioelectrochemistry
- Vol. 165, 108951
Magnetic MOF-based sensing platform integrated with graphene field-effect transistors for ultrasensitive detection of infectious disease
- 4 June 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1315, 342804
Sensitive detection of infectious disease utilizing carbon Sphere@Fe3O4 micromotor combined with graphene field-effect transistor
- 4 June 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1315, 342804
Sensitive detection of infectious disease utilizing carbon Sphere@Fe3O4 micromotor combined with graphene field-effect transistor
- 11 April 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (5) , 1-8
On-site detection of infectious disease based on CaCO3-based magnetic micromotor integrated with graphene field effect transistor
A new detection platform based on CaCO3-based magnetic micromotor (CaCO3@Fe3O4) integrated with graphene field effect transistor (GFET) was construct and used for on-site SARS-CoV-2 coronavirus pathogen detection. The CaCO3@Fe3O4 micromotor, which was modified with anti-SARS-CoV-2 (labelled antibody, AntiE1), can self-moved in the solution containing hydrochloric acid (HCl) and effective to capture the SARS-CoV-2 coronavirus pathogens. After magnetic field separation, the capture micromotor was detected by GFET, exhibiting a good linear relationship within the range of 1 ag/mL to 100 ng/mL and low detection limit (0.39 ag/mL). Furthermore, the detection platform was also successfully applied to detection of SARS-CoV-2 coronavirus pathogens in soil solution, indicating the potential use in on-site application. Graphical Abstract
- 11 April 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (5) , 1-8
On-site detection of infectious disease based on CaCO3-based magnetic micromotor integrated with graphene field effect transistor
A new detection platform based on CaCO3-based magnetic micromotor (CaCO3@Fe3O4) integrated with graphene field effect transistor (GFET) was construct and used for on-site SARS-CoV-2 coronavirus pathogen detection. The CaCO3@Fe3O4 micromotor, which was modified with anti-SARS-CoV-2 (labelled antibody, AntiE1), can self-moved in the solution containing hydrochloric acid (HCl) and effective to capture the SARS-CoV-2 coronavirus pathogens. After magnetic field separation, the capture micromotor was detected by GFET, exhibiting a good linear relationship within the range of 1 ag/mL to 100 ng/mL and low detection limit (0.39 ag/mL). Furthermore, the detection platform was also successfully applied to detection of SARS-CoV-2 coronavirus pathogens in soil solution, indicating the potential use in on-site application. Graphical Abstract
- Open Access
NiCoP/g-C3N4 Nanocomposites-Based Electrochemical Immunosensor for Sensitive Detection of Procalcitonin
Herein, an ultra-sensitive and facile electrochemical biosensor for procalcitonin (PCT) detection was developed based on NiCoP/g-C3N4 nanocomposites. Firstly, NiCoP/g-C3N4 nanocomposites were synthesized using hydrothermal methods and then functionalized on the electrode surface by π-π stacking. Afterward, the monoclonal antibody that can specifically capture the PCT was successfully linked onto the surface of the nanocomposites with a 1-(3-Dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) and N-Hydroxysuccinimide (NHS) condensation reaction. Finally, the modified sensor was employed for the electrochemical analysis of PCT using differential Pulse Voltammetry(DPV). Notably, the larger surface area of g-C3N4 and the higher electron transfer capacity of NiCoP/g-C3N4 endow this sensor with a wider detection range (1 ag/mL to 10 ng/mL) and an ultra-low limit of detection (0.6 ag/mL, S/N = 3). In addition, this strategy was also successfully applied to the detection of PCT in the diluted human serum sample, demonstrating that the developed immunosensors have the potential for application in clinical testing.
Open AccessNiCoP/g-C3N4 Nanocomposites-Based Electrochemical Immunosensor for Sensitive Detection of Procalcitonin
Herein, an ultra-sensitive and facile electrochemical biosensor for procalcitonin (PCT) detection was developed based on NiCoP/g-C3N4 nanocomposites. Firstly, NiCoP/g-C3N4 nanocomposites were synthesized using hydrothermal methods and then functionalized on the electrode surface by π-π stacking. Afterward, the monoclonal antibody that can specifically capture the PCT was successfully linked onto the surface of the nanocomposites with a 1-(3-Dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) and N-Hydroxysuccinimide (NHS) condensation reaction. Finally, the modified sensor was employed for the electrochemical analysis of PCT using differential Pulse Voltammetry(DPV). Notably, the larger surface area of g-C3N4 and the higher electron transfer capacity of NiCoP/g-C3N4 endow this sensor with a wider detection range (1 ag/mL to 10 ng/mL) and an ultra-low limit of detection (0.6 ag/mL, S/N = 3). In addition, this strategy was also successfully applied to the detection of PCT in the diluted human serum sample, demonstrating that the developed immunosensors have the potential for application in clinical testing.
- 14 December 2022
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 47 (3) , 1563-1572
Phenylboronic acid conjugated poly(3,4-ethylenedioxythiophene) (PEDOT) coated Ag dendrite for electrochemical non-enzymatic glucose sensing
Blood glucose monitoring is the premise and basis of diabetes diagnosis and treatment. Previously, we developed polythiophene modified by phenylboronic acid derivatives for non-enzyme detection of glucose and discussed the effect of the structure of phenylboronic acid on the response to glucose. In this study, we investigated the effect of the surface morphology of phenylboronic acid-modified polythiophene (poly(EDOT-PBA)) on glucose-sensing performance. To this end, we developed a fern leaf-like structured poly(EDOT-PBA) film and discussed the effect of surface morphology of poly(EDOT-PBA) for glucose sensing. The modified electrode surfaces were characterized by X-ray photoelectron spectroscopy, scanning electron microscopy, static water contact angle, and impedance measurements. The specific interaction between PBA and glucose was detected by impedancemetry. The concentration-dependent specific response was observed in glucose solution. The sensitivity was 426.1 Ω mM−1 cm−2 in 0.05–30 mM with a limit of detection of 0.01 mM. The glucose sensor has good selectivity and stability.
- 14 December 2022
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 47 (3) , 1563-1572
Phenylboronic acid conjugated poly(3,4-ethylenedioxythiophene) (PEDOT) coated Ag dendrite for electrochemical non-enzymatic glucose sensing
Blood glucose monitoring is the premise and basis of diabetes diagnosis and treatment. Previously, we developed polythiophene modified by phenylboronic acid derivatives for non-enzyme detection of glucose and discussed the effect of the structure of phenylboronic acid on the response to glucose. In this study, we investigated the effect of the surface morphology of phenylboronic acid-modified polythiophene (poly(EDOT-PBA)) on glucose-sensing performance. To this end, we developed a fern leaf-like structured poly(EDOT-PBA) film and discussed the effect of surface morphology of poly(EDOT-PBA) for glucose sensing. The modified electrode surfaces were characterized by X-ray photoelectron spectroscopy, scanning electron microscopy, static water contact angle, and impedance measurements. The specific interaction between PBA and glucose was detected by impedancemetry. The concentration-dependent specific response was observed in glucose solution. The sensitivity was 426.1 Ω mM−1 cm−2 in 0.05–30 mM with a limit of detection of 0.01 mM. The glucose sensor has good selectivity and stability.