Wenyi Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wenyi Li has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Chuntao Li
HeBei North University, Zhangjiakou, Hebei, China
3 shared publications Can Cao
Spinal Surgery Medical Team of Orthopedics, Hebei General Hospital, Shijiazhuang, Hebei, China
2 shared publicationsChangren Li
HeBei North University, Zhangjiakou, Hebei, China
2 shared publicationsLiang He
HeBei North University, Zhangjiakou, Hebei, China
2 shared publicationsMeng Li
Hebei Medical University, Shijiazhuang, Hebei, China
2 shared publicationsShangju Gao
Spinal Surgery Medical Team of Orthopedics, Hebei General Hospital, Shijiazhuang, Hebei, China
2 shared publications
Latest Publications
- Open Access
- 30 September 2022
- Published by Wolters Kluwer Health in Medicine
- Vol. 101 (39) , e30412
Comparison of unilateral biportal endoscopic discectomy versus percutaneous endoscopic lumbar discectomy for the treatment of lumbar disc herniation: A systematic review and meta-analysis
Background: The purpose of this study was to analyze unilateral biportal endoscopic discectomy (UBE) and percutaneous endoscopic lumbar discectomy (PELD) for the treatment of lumbar disc herniation. Methods: PubMed, EMBASE, Web of Science, Cochrane Database, CNKI, and Wanfang databases were searched online. All statistical analyses were performed using STATA 16.0. Results: The selection criteria were met by 6 studies with a total of 281 patients (142 cases in the UBE group and 139 cases in the PELD group) and good methodological quality. PELD has the potential to improve outcomes such as operation time and intraoperative hemorrhage (MD = 36.808, 95% CI (23.766, 49.850), P = .000; MD = 59.269, 95% CI (21.527, 97.010), P = .000) compared with UBE. No differences were found in the back pain VAS score at preoperative (MD = −0.024, 95% CI [−0.572, 0.092], P = .998), at 1 day after operation (MD = −0.300, 95% CI [−0.845, 0.246], P = .878), the VAS score of leg pain at preoperative (MD = −0.099, 95% CI [−0.417, 0.220], P = .762), at 1 day after operation (MD = 0.843, 95% CI [0.193, 1.492], P = .420), at 1 month after operation (MD = −0.027, 95% CI [−0.433, 0.380], P = .386), at 6 months after operation (MD = 0.122, 95% CI [−0.035, 0.278], P = .946), hospital stay (MD = 3.708, 95% CI [3.202, 4.214], P = .000) and other clinical effects between UBE and PELD group. Conclusions: There are no significant differences in clinical efficacy between UBE and PELD, according to the research. However, PELD has the potential to improve outcomes such as operation time and intraoperative hemorrhage. As just a result, PELD is better suited in the treatment of lumbar disc herniation.
- 30 September 2022
- Published by Wolters Kluwer Health in Medicine
- Vol. 101 (39) , e30412
Open AccessComparison of unilateral biportal endoscopic discectomy versus percutaneous endoscopic lumbar discectomy for the treatment of lumbar disc herniation: A systematic review and meta-analysis
Background: The purpose of this study was to analyze unilateral biportal endoscopic discectomy (UBE) and percutaneous endoscopic lumbar discectomy (PELD) for the treatment of lumbar disc herniation. Methods: PubMed, EMBASE, Web of Science, Cochrane Database, CNKI, and Wanfang databases were searched online. All statistical analyses were performed using STATA 16.0. Results: The selection criteria were met by 6 studies with a total of 281 patients (142 cases in the UBE group and 139 cases in the PELD group) and good methodological quality. PELD has the potential to improve outcomes such as operation time and intraoperative hemorrhage (MD = 36.808, 95% CI (23.766, 49.850), P = .000; MD = 59.269, 95% CI (21.527, 97.010), P = .000) compared with UBE. No differences were found in the back pain VAS score at preoperative (MD = −0.024, 95% CI [−0.572, 0.092], P = .998), at 1 day after operation (MD = −0.300, 95% CI [−0.845, 0.246], P = .878), the VAS score of leg pain at preoperative (MD = −0.099, 95% CI [−0.417, 0.220], P = .762), at 1 day after operation (MD = 0.843, 95% CI [0.193, 1.492], P = .420), at 1 month after operation (MD = −0.027, 95% CI [−0.433, 0.380], P = .386), at 6 months after operation (MD = 0.122, 95% CI [−0.035, 0.278], P = .946), hospital stay (MD = 3.708, 95% CI [3.202, 4.214], P = .000) and other clinical effects between UBE and PELD group. Conclusions: There are no significant differences in clinical efficacy between UBE and PELD, according to the research. However, PELD has the potential to improve outcomes such as operation time and intraoperative hemorrhage. As just a result, PELD is better suited in the treatment of lumbar disc herniation.
- Open Access
- 17 December 2021
- Published by Wolters Kluwer Health in Medicine
- Vol. 100 (50) , e27970
Efficacy and safety of unilateral biportal endoscopy compared with microscopic decompression in the treatment of lumbar spinal stenosis
Objective: Systematic evaluation of the efficacy and safety of unilateral biportal endoscopic decompression in the treatment of lumbar spinal stenosis. Methods: We conducted a systematic literature search and compared the randomized controlled trials (RCTs) and retrospective studies of unilateral biportal endoscopy (UBE) and microscopic decompression (MD) in the treatment of lumbar spinal stenosis from several databases. Results: Seven studies were included. The results of meta-analysis showed that the operation time of UBE was shorter than that of MD. [SMD = −0.443, 95% CI (−0.717, −0.169), P = .002]. Compared with MD, the patients’ back pain was slighter on the 1st day, 1–2 months and 6 months after UBE. During the long-term follow-up, there was no significant difference in back pain between MD and UBE [SMD = −0.519, 95% CI (−0.934, −0.104), P = .014]. There was no significant difference in lower limb visual analogue score (VAS) score between UBE decompression and MD [SMD = −0.105, 95% CI (−0.356, 0.146), P = .412]. The results of meta-analysis showed that the C-reactive protein (CRP) level of UBE was lower than that of MD [weighted mean difference = −1.437, 95% CI (−2.347, −0.527), P = .002]. There was no significant difference in other clinical effects between the 2 groups. Conclusion: The operation time of UBE was shorter than that of MD, and it was superior to micro decompression in early back VAS score, lower limb VAS score and early postoperative CRP level. There was no statistical difference between UBE and MD in other outcomes.
- 17 December 2021
- Published by Wolters Kluwer Health in Medicine
- Vol. 100 (50) , e27970
Open AccessEfficacy and safety of unilateral biportal endoscopy compared with microscopic decompression in the treatment of lumbar spinal stenosis
Objective: Systematic evaluation of the efficacy and safety of unilateral biportal endoscopic decompression in the treatment of lumbar spinal stenosis. Methods: We conducted a systematic literature search and compared the randomized controlled trials (RCTs) and retrospective studies of unilateral biportal endoscopy (UBE) and microscopic decompression (MD) in the treatment of lumbar spinal stenosis from several databases. Results: Seven studies were included. The results of meta-analysis showed that the operation time of UBE was shorter than that of MD. [SMD = −0.443, 95% CI (−0.717, −0.169), P = .002]. Compared with MD, the patients’ back pain was slighter on the 1st day, 1–2 months and 6 months after UBE. During the long-term follow-up, there was no significant difference in back pain between MD and UBE [SMD = −0.519, 95% CI (−0.934, −0.104), P = .014]. There was no significant difference in lower limb visual analogue score (VAS) score between UBE decompression and MD [SMD = −0.105, 95% CI (−0.356, 0.146), P = .412]. The results of meta-analysis showed that the C-reactive protein (CRP) level of UBE was lower than that of MD [weighted mean difference = −1.437, 95% CI (−2.347, −0.527), P = .002]. There was no significant difference in other clinical effects between the 2 groups. Conclusion: The operation time of UBE was shorter than that of MD, and it was superior to micro decompression in early back VAS score, lower limb VAS score and early postoperative CRP level. There was no statistical difference between UBE and MD in other outcomes.
- Open Access
- 24 September 2021
- Published by Wolters Kluwer Health in Medicine
- Vol. 100 (38) , e27282
Comparison of accuracy and safety between robot-assisted and conventional fluoroscope assisted placement of pedicle screws in thoracolumbar spine
Objective: The purpose of this systematic review and meta-analysis is to explore the screw positioning accuracy, complications related to pedicle screw implantation, revision rate and radiation exposure between robot screw placement and traditional fluoroscopic screw placement. Methods: We searched several databases, including CNKI, Wanfang database, cqvip datebase, PubMed, Cochrane library and EMBASE, to identify articles that might meet the criteria. Meta-analysis was performed using Revman 5.3 software. Results: A total of 13 randomized controlled trial were included. The results showed that the pedicle screw accuracy of the robot assisted group was significantly better than that of the conventional freehand (FH) group (OR = 3.5, 95% confidence interval [CI] [2.75,4.45], P < .0001). There was no significant difference in the complications caused by pedicle screw implantation between the robot-assisted group and the conventional FH group [OR = 0.39, 95%CI (0.10,1.48), P = .17]. The rate of facet joint invasion in the robot-assisted group was significantly lower than that in the conventional FH group (OR = 0.06, 95%CI [0.01,0.29], P = .0006). The revision rate in the robot-assisted group was significantly lower than that in the conventional FH group (OR = 0.19, 95%CI [0.05,0.71], P = 0.0.01). There was no significant difference in the average radiation of pedicle screws implantation between the robot-assisted group and the conventional FH (mean difference = -7.94, 95%CI [-20.18,4.30], P = .20). Conclusion: The robot-assisted group was significantly better than the conventional FH in the accuracy of pedicle screw placement and facet joint invasion rate and revision rate. There was no significant difference in the complication and fluoroscopy time between the two groups.
- 24 September 2021
- Published by Wolters Kluwer Health in Medicine
- Vol. 100 (38) , e27282
Open AccessComparison of accuracy and safety between robot-assisted and conventional fluoroscope assisted placement of pedicle screws in thoracolumbar spine
Objective: The purpose of this systematic review and meta-analysis is to explore the screw positioning accuracy, complications related to pedicle screw implantation, revision rate and radiation exposure between robot screw placement and traditional fluoroscopic screw placement. Methods: We searched several databases, including CNKI, Wanfang database, cqvip datebase, PubMed, Cochrane library and EMBASE, to identify articles that might meet the criteria. Meta-analysis was performed using Revman 5.3 software. Results: A total of 13 randomized controlled trial were included. The results showed that the pedicle screw accuracy of the robot assisted group was significantly better than that of the conventional freehand (FH) group (OR = 3.5, 95% confidence interval [CI] [2.75,4.45], P < .0001). There was no significant difference in the complications caused by pedicle screw implantation between the robot-assisted group and the conventional FH group [OR = 0.39, 95%CI (0.10,1.48), P = .17]. The rate of facet joint invasion in the robot-assisted group was significantly lower than that in the conventional FH group (OR = 0.06, 95%CI [0.01,0.29], P = .0006). The revision rate in the robot-assisted group was significantly lower than that in the conventional FH group (OR = 0.19, 95%CI [0.05,0.71], P = 0.0.01). There was no significant difference in the average radiation of pedicle screws implantation between the robot-assisted group and the conventional FH (mean difference = -7.94, 95%CI [-20.18,4.30], P = .20). Conclusion: The robot-assisted group was significantly better than the conventional FH in the accuracy of pedicle screw placement and facet joint invasion rate and revision rate. There was no significant difference in the complication and fluoroscopy time between the two groups.