CXChu Thi Xuan

Chu Thi Xuan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chu Thi Xuan has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ultrasensitive gas sensor based on 3D assembled SnS2/SnO2 nanoflowers for NO2 detection at room temperature

    by To Thi Nguyet, Nguyen Pham Yen Nhi, Pham Van Tong, Nguyen Viet Nhat, Chu Thi Xuan, Tran Thi Viet Nga, Nguyen Van Duy, Chu Manh Hung, Mingzhi Jiao, Nguyen Duc Hoa

  • Numerical investigation of droplet formation in T-junction microfluidic system with a semi-NACA-shaped squeezer

    by Ich Long Ngo, Van Nam Dao, Thi-Xuan Chu

    We present a numerical investigation of droplet formation in a T-junction microfluidic system with a semi-NACA-shaped squeezer. A two-dimensional numerical model is employed to simulate the droplet formation process using the Volume of Fluid method. The integration of this semi-NACA squeezer has a positive influence on the droplet formation dynamics under identical operating conditions. By varying the squeezer size, an inverse correlation is observed between squeezer size and droplet size. Additionally, the droplet formation process in the microfluidic T-junction device is highly dependent on the viscosity ratio, with droplet size decreasing as the viscosity ratio increases. These findings contribute to a better understanding of the droplet dynamic in T-junction devices, paving the way for new applications in microfluidic technology

  • Open Access

    Non-enzymatic glucose sensor based on Ni(OH)2/NF materials using different pulse voltammetry technique

    by Trinh Xuan Minh Do, Hieu Trung Dinh, Vu Diem Ngoc Tran, Van Tuan Chu, Hai Ha Nguyen, Tri Quang Le, Thi Xuan Chu, Thi Thanh Le Dang, Nhu Quynh Luc, Duc Hoa Nguyen

    Non-enzymatic glucose sensors have gained significant attention owing to their potential for accurate and cost-effective glucose detection. Nanomaterials play a pivotal role in enhancing performance of non-enzymatic glucose sensor. In this study, we introduce a novel non-enzymatic glucose sensor based on Ni(OH)2/NF (nickel hydroxide/nickel foam) materials using different pulse voltammetry technique. Chemical precipitation methods have been used to grow Ni(OH)2 nanostructures directly on a nickel foam electrode. The characterization of the synthesized materials was performed through field emission scanning electron microscopy (FESEM), energy dispersive spectroscopy (EDX), and X-ray diffraction (XRD). The performance of the Ni(OH)2/NF-based glucose sensor was evaluated through electrochemical measurements. Nanoscale hive-like structures of Ni(OH)2 with a diameter ranging from 450 to 530 μm and a thickness of 20 nm were formed on the NF surface. The sensor exhibited good performance, displaying a high sensitivity of 8.42 mA mM-1 cm-2 with a low detection limit of 0.84 μM. These results position the synthesized electrode as a promising contender for non-enzymatic electrochemical glucose sensors.


  • Hydrogen gas sensor based on self-heating effect of SnO2/Pt thin film with ultralow power consumption

    by Vo Thanh Duoc, Hugo Nguyen, Trinh Minh Ngoc, Chu Thi Xuan, Chu Manh Hung, Nguyen Van Duy, Nguyen Duc Hoa


  • One-Step Method for the Direct Growth of NiO Nanoflowers on Pencil Graphite Electrode for Highly Sensitive Non-Enzymatic Glucose Sensing

    by Do Thi Phong Thu, Chu Thi Xuan, Vu Thi Oanh, Nguyen Xuan Viet, Le Manh Tu, To Thanh Loan, Chu Van Tuan, Nguyen Hai Ha, Dang Thi Thanh Le, Nguyen Duc Hoa

    Electrochemical glucose sensors, including enzymatic and non-enzymatic sensors, have been considered as quick, accurate, and efficent means for glucose measurement. Recently, non-enzymatic electrochemical glucose sensor based on metal oxides have been paid attention to develop thank to their outstanding behaviours. In most of these studies, metal oxides were synthesized individually and subsequently deposited on the electrode surface using a binder. In this study, we aim at developing a non-enzymatic glucose sensor based on NiO nanoflowers directly grown on a commercial pencil graphite electrode. NiO matetials were deposited on the electrode without a binder via a facile and low-cost chemical procedure. The synthesised materials’ morphologies and components of were characterized by a field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray diffraction analyses. Electrocatalytic performance was recorded by cyclic voltammetry and chronoamperometry. The resulting NiO nanoflowers, characterized by funnel-shaped structures measuring 500–600 nm in diameter and 20 nm in thickness, were formed on the pencil graphite electrode. The fabricated electrode showed a remarkably high sensitivity of 337 μA mM−1 cm−2, a low limit of detection of 4 μM, and good selectivity. The fabricated electrode can be a potential candidate for clinically medical applications.


  • Instant Facile Method for the In Situ Growth of Ni(OH)2 Nanohives on Nickel Foam for Non-Enzymatic Electrochemical Glucose Sensor

    by Vu Thi Oanh, Chu Thi Xuan, Le Manh Tu, Nguyen Xuan Viet, Nguyen Duc Hoa

    Glucose sensor has attracted the attention of academic and industrial researchers because of its broad applications in diabetes management, food quality control, and bioprocess inspection. Compared with enzymatic glucose sensors, non-enzymatic glucose sensors are more relevant because of their stable, sensitive, and low-cost process. The simple and low-cost synthesis of advanced nanomaterials for a non-enzymatic glucose sensor is vital in practical applications. Here, we introduce a facile chemical method for the direct synthesis of nickel(II) hydroxide nanostructures on porous nickel foam (NF) for an electrochemical glucose sensor. The properties of the synthesized material were characterized by field-emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, high-resolution transmission electron microscopy, selected area electron diffraction, and Raman spectroscopy. The fabricated materials were applied for glucose concentration measurement in 0.1 M NaOH by cyclic voltammetry and chronoamperometry. The Ni(OH)2/NF sensor is stable and has excellent sensitivity (12.55 mA mM−1 cm−2) with a low detection limit of 57 μM (S/N = 3) and high selectivity for glucose detection in the presence of common interfering species. The Ni(OH)2/Ni electrode was successfully tested in measuring glucose concentration in real serum samples. The fabricated Ni(OH)2/NF electrode can be used as a low-cost, sensitive, stable and selective platform for non-enzymatic glucose sensors.


  • Open Access

    Novel Synthesis of Pani/Zno Nanohybrid for Enhanced No2 Gas Sensing Performance at Low Temperatures

    by Nguyet Thi To, Duy Van Lai, Nguyet Thi-Minh Quan, Xuan Thi Chu, Le Thi Thanh Dang, Hung Manh Chu, Duy Van Nguyen, Duc Hoa Nguyen

    Nanohybrids, which comprise organic and inorganic materials, have gained increasing interest in the application for enhanced sensing performance to both reducing and oxidation gases. In this study, using the hydrothermal route for high-performance nitrogen dioxide (NO2) gas sensing at low temperatures, we prepared nanohybrids of polyaniline (PANI) and ZnO nanoplates. The structure, morphology, and surface composition of synthesized nanohybrids were respectively examined via X-ray diffraction, scanning electron microscopy, transmission electron microscopy, and Fourier transform infrared spectroscopy. Gas sensing measurements of the samples indicated that the resistive sensor based on PANI/ZnO hybrid showed the highest response toward NO2 at 150°C with the response value Rg/Ra = 601 to 5 ppm NO2. We also investigated the sensing properties of vapor organic compounds (methanol, ethanol, triethylamine, toluene, and isopropanol). Indeed, the heterojunction reflects the characteristics of n-type semiconductor ZnO. Characterization and gas sensing measurements indicated the protonation and deprotonation process of PANI/ZnO heterojunction, which contribute to the nitrogen oxygen sensing mechanism. Overall, the obtained findings demonstrated that the PANI/ZnO nanoplates were promising materials for sensing applications in food analysis and environmental monitoring.

  • A highly sensitive non-enzymatic glucose electrochemical sensor based on NiO nanohives

    by Thi Oanh Vu, Thi Xuan Chu, Duc Hoa Nguyen

    Diabetes is a dangerous chronic disease leading to death. Regular glucose level monitoring in the blood is very important to reduce the risk of diabetes. A lot of methods have been developed to measure the glucose concentration. The non-enzymatic glucose sensor is one of the efficient methods, which has attracted much attention from researchers. In this work, a facile process for the synthesis of NiO nanohives on the surface of nickel foam substrate was reported to apply for the non-enzymatic glucose electrochemical sensing. Morphologies and components of the obtained materials were characterised by field emission scanning electron microscopy (FE-SEM) and energy-dispersive x-ray spectroscopy. FE-SEM images show homogeneous NiO nanohives covering the surface of nickel foam with each cavity diameter of 300–500 nm. Cyclic voltammetry and amperometry were conducted to measure the electrochemical properties of the synthesised NiO/Ni electrodes. The results show that the sensor is highly sensitive (10.08 mA mM −1 cm −2 ) with a low detection limit (7.25 μ A), which is evaluated highly potential to apply for the non-enzymatic glucose electrochemical sensor.


  • Open Access

    In‐Channel‐Grown Polypyrrole Nanowire for the Detection of DNA Hybridization in an Electrochemical Microfluidic Biosensor

    by Thi Luyen Tran, Thi Xuan Chu, Phuc Quan Do, Duc Thanh Pham, Van Vu Quan Trieu, Dang Chinh Huynh, Anh Tuan Mai

    A triple electrode setup with a Pt pseudo‐reference electrode integrated in a polydimethylsiloxane‐ (PDMS‐) based microchamber was designed and fabricated. The integrated electrodes were deposited onto SiO2/Si substrate by sputtering. The PDMS microchamber was patterned using an SU‐8 mold and sealed with electrodes in oxygen plasma. Polypyrrole nanowires (PPy NWs) were electrochemically grown in situ at an accurate position of the working electrode in the sealed microchamber instead of in an open system. The DNA probe sequences were simply introduced into the channel to form bonds with the nanowires. A detection limit of 20 pM was achieved using a lock‐in amplifier. The electrochemical characteristics produced by the hybridization of DNA strands in the microchamber showed a good signal/noise ratio and high sensitivity. Measurement of the DNA sensor in narrow space also required much less volume of the analytical sample compared with that in an open measuring cell. Results showed that this simple system can potentially fabricate nanostructures and detect bio/chemical molecules in a sealed system.