Yui Okada Nozaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yui Okada Nozaki has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Shinichiro Fujimoto
Juntendo University Graduate School of Medicine
3 shared publications - Ayako Kudo
Department of Cardiovascular Biology and Medicine, Juntendo University Graduate School of Medicine, Tokyo 113-8421, Japan
2 shared publications - Chihiro Aoshima
Department of Cardiovascular Biology and Medicine, Juntendo University Graduate School of Medicine, Tokyo 113-8421, Japan
2 shared publications - Daigo Takahashi
Department of Cardiovascular Biology and Medicine, Juntendo University Graduate School of Medicine, Tokyo 113-8421, Japan
2 shared publications - Kazuhisa Takamura
Department of Cardiovascular Biology and Medicine, Juntendo University Graduate School of Medicine, Tokyo 113-8421, Japan
2 shared publications - Makoto Hiki
Department of Cardiovascular Biology and Medicine, Juntendo University Graduate School of Medicine, Tokyo 113-8421, Japan
2 shared publications
Latest Publications
- Open Access
- 3 March 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (2) , 025026
Automatic localization of cross sections corresponding to standard transesophageal echocardiographic views on computed tomography volume
Aims : Preoperative observation of computed tomography (CT) cross sections corresponding to standard transesophageal echocardiographic (TEE) views is useful for treatments using TEE. However, manually locating those CT cross sections from the CT volume is time consuming. This study aimed to develop a fully automatic method to locate those CT cross sections corresponding to standard TEE views. Methods : Developed method crops CT volume based on the heart segmentation model if input is a chest CT. CT cross sections corresponding to standard TEE views are coarsely located from cropped chest CT or cardiac CT based on the esophagus segmentation model and the plane localization model. The coarse cross sections are refined based on the anatomical landmark detection model. Accuracies of located CT cross sections were evaluated by five-fold cross validation with comparison to manually set cross sections, using 110 CT volumes. The results were also compared to the top and the middle axial section of the heart as baselines. Results : The mean of rotation error, probe position error, landmark error and structural similarity index between the predicted and manually set cross sections were 12.52 ± 8.27 degree, 13.90 ± 10.62 mm, 3.95 ± 3.48 mm and 0.64 ± 0.15, respectively, and these errors were significantly smaller than the baselines. The mean processing time was 41.34 ± 22.75 s. Conclusions : Our developed method can provide CT cross sections corresponding to standard TEE views without user operations, resulting in faster treatment planning with less effort and without inter user variability in treatments using TEE.
- 3 March 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (2) , 025026
Open AccessAutomatic localization of cross sections corresponding to standard transesophageal echocardiographic views on computed tomography volume
Aims : Preoperative observation of computed tomography (CT) cross sections corresponding to standard transesophageal echocardiographic (TEE) views is useful for treatments using TEE. However, manually locating those CT cross sections from the CT volume is time consuming. This study aimed to develop a fully automatic method to locate those CT cross sections corresponding to standard TEE views. Methods : Developed method crops CT volume based on the heart segmentation model if input is a chest CT. CT cross sections corresponding to standard TEE views are coarsely located from cropped chest CT or cardiac CT based on the esophagus segmentation model and the plane localization model. The coarse cross sections are refined based on the anatomical landmark detection model. Accuracies of located CT cross sections were evaluated by five-fold cross validation with comparison to manually set cross sections, using 110 CT volumes. The results were also compared to the top and the middle axial section of the heart as baselines. Results : The mean of rotation error, probe position error, landmark error and structural similarity index between the predicted and manually set cross sections were 12.52 ± 8.27 degree, 13.90 ± 10.62 mm, 3.95 ± 3.48 mm and 0.64 ± 0.15, respectively, and these errors were significantly smaller than the baselines. The mean processing time was 41.34 ± 22.75 s. Conclusions : Our developed method can provide CT cross sections corresponding to standard TEE views without user operations, resulting in faster treatment planning with less effort and without inter user variability in treatments using TEE.
- Open Access
- 24 February 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (5) , 1226
Identification of Risk Factors for Coronary Artery Disease in Asymptomatic Patients with Type 2 Diabetes Mellitus
Background: Patients with diabetes mellitus (DM) are a high-risk group for coronary artery disease (CAD). In the present study, we investigated predictive factors to identify patients at high risk of CAD among asymptomatic patients with type 2 DM based on coronary computed tomographic angiography (CCTA) findings. Methods: A single-center prospective study was performed on 452 consecutive patients with type 2 DM who were provided with a weekly hospital-based diabetes education program between 3 October 2015, and 31 March 2020. A total of 161 consecutive asymptomatic patients (male/female: 111/50, age: 57.3 ± 9.3 years) with type 2 DM without any known CAD underwent CCTA. Based on conventional coronary risk factors and non-invasive examination, i.e., measurement of intima-media thickness, subcutaneous and visceral fat area, a stress electrocardiogram test, and the Agatston score, patients with obstructive CAD, CT-verified high-risk plaques (CT-HRP), and optimal revascularization within 90 days were evaluated. Results: Current smoking (OR, 4.069; 95% C.I., 1.578–10.493, p = 0.0037) and the Agatston score ≥100 (OR, 18.034; 95% C.I., 6.337–51.324, p = 0.0001) were independent predictive factors for obstructive CAD, while current smoking (OR, 5.013; 95% C.I., 1.683–14.931, p = 0.0038) was an independent predictive factor for CT-HRP. Furthermore, insulin treatment (OR, 5.677; 95% C.I., 1.223–26.349, p = 0.0266) was the only predictive factor that correlated with optimal revascularization within 90 days. Conclusions: In asymptomatic patients with type 2 DM, current smoking, an Agatston score ≥100, and insulin treatment were independent predictive factors of patients being at high-risk for CAD. However, non-invasive examinations except for Agatston score were not independent predictors of patients being at high risk of CAD.
- 24 February 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (5) , 1226
Open AccessIdentification of Risk Factors for Coronary Artery Disease in Asymptomatic Patients with Type 2 Diabetes Mellitus
Background: Patients with diabetes mellitus (DM) are a high-risk group for coronary artery disease (CAD). In the present study, we investigated predictive factors to identify patients at high risk of CAD among asymptomatic patients with type 2 DM based on coronary computed tomographic angiography (CCTA) findings. Methods: A single-center prospective study was performed on 452 consecutive patients with type 2 DM who were provided with a weekly hospital-based diabetes education program between 3 October 2015, and 31 March 2020. A total of 161 consecutive asymptomatic patients (male/female: 111/50, age: 57.3 ± 9.3 years) with type 2 DM without any known CAD underwent CCTA. Based on conventional coronary risk factors and non-invasive examination, i.e., measurement of intima-media thickness, subcutaneous and visceral fat area, a stress electrocardiogram test, and the Agatston score, patients with obstructive CAD, CT-verified high-risk plaques (CT-HRP), and optimal revascularization within 90 days were evaluated. Results: Current smoking (OR, 4.069; 95% C.I., 1.578–10.493, p = 0.0037) and the Agatston score ≥100 (OR, 18.034; 95% C.I., 6.337–51.324, p = 0.0001) were independent predictive factors for obstructive CAD, while current smoking (OR, 5.013; 95% C.I., 1.683–14.931, p = 0.0038) was an independent predictive factor for CT-HRP. Furthermore, insulin treatment (OR, 5.677; 95% C.I., 1.223–26.349, p = 0.0266) was the only predictive factor that correlated with optimal revascularization within 90 days. Conclusions: In asymptomatic patients with type 2 DM, current smoking, an Agatston score ≥100, and insulin treatment were independent predictive factors of patients being at high-risk for CAD. However, non-invasive examinations except for Agatston score were not independent predictors of patients being at high risk of CAD.
- Open Access
- 26 September 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (19) , 4398
Incremental Diagnostic Value of CT Fractional Flow Reserve Using Subtraction Method in Patients with Severe Calcification: A Pilot Study
Although on-site workstation-based CT fractional flow reserve (CT-FFR) is an emerging method for assessing vessel-specific ischemia in coronary artery disease, severe calcification is a significant factor affecting CT-FFR’s diagnostic performance. The subtraction method significantly improves the diagnostic value with respect to anatomic stenosis for patients with severe calcification in coronary CT angiography (CCTA). We evaluated the diagnostic capability of CT-FFR using the subtraction method (subtraction CT-FFR) in patients with severe calcification. This study included 32 patients with 45 lesions with severe calcification (Agatston score >400) who underwent both CCTA and subtraction CCTA using 320-row area detector CT and also received invasive FFR within 90 days. The diagnostic capabilities of CT-FFR and subtraction CT-FFR were compared. The sensitivities, specificities, positive predictive values (PPVs), and negative predictive values (NPVs) of CT-FFR vs. subtraction CT-FFR for detecting hemodynamically significant stenosis, defined as FFR ≤ 0.8, were 84.6% vs. 92.3%, 59.4% vs. 75.0%, 45.8% vs. 60.0%, and 90.5% vs. 96.0%, respectively. The area under the curve for subtraction CT-FFR was significantly higher than for CT-FFR (0.84 vs. 0.70) (p = 0.04). The inter-observer and intra-observer variabilities of subtraction CT-FFR were 0.76 and 0.75, respectively. In patients with severe calcification, subtraction CT-FFR had an incremental diagnostic value over CT-FFR, increasing the specificity and PPV while maintaining the sensitivity and NPV with high reproducibility.
- 26 September 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (19) , 4398
Open AccessIncremental Diagnostic Value of CT Fractional Flow Reserve Using Subtraction Method in Patients with Severe Calcification: A Pilot Study
Although on-site workstation-based CT fractional flow reserve (CT-FFR) is an emerging method for assessing vessel-specific ischemia in coronary artery disease, severe calcification is a significant factor affecting CT-FFR’s diagnostic performance. The subtraction method significantly improves the diagnostic value with respect to anatomic stenosis for patients with severe calcification in coronary CT angiography (CCTA). We evaluated the diagnostic capability of CT-FFR using the subtraction method (subtraction CT-FFR) in patients with severe calcification. This study included 32 patients with 45 lesions with severe calcification (Agatston score >400) who underwent both CCTA and subtraction CCTA using 320-row area detector CT and also received invasive FFR within 90 days. The diagnostic capabilities of CT-FFR and subtraction CT-FFR were compared. The sensitivities, specificities, positive predictive values (PPVs), and negative predictive values (NPVs) of CT-FFR vs. subtraction CT-FFR for detecting hemodynamically significant stenosis, defined as FFR ≤ 0.8, were 84.6% vs. 92.3%, 59.4% vs. 75.0%, 45.8% vs. 60.0%, and 90.5% vs. 96.0%, respectively. The area under the curve for subtraction CT-FFR was significantly higher than for CT-FFR (0.84 vs. 0.70) (p = 0.04). The inter-observer and intra-observer variabilities of subtraction CT-FFR were 0.76 and 0.75, respectively. In patients with severe calcification, subtraction CT-FFR had an incremental diagnostic value over CT-FFR, increasing the specificity and PPV while maintaining the sensitivity and NPV with high reproducibility.