Tatsuya Kitamura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tatsuya Kitamura has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Tomohiro Umetani
Konan University
5 shared publications Hironori Takemoto
Chiba Institute of Technology, Narashino, Chiba, Japan
4 shared publications- Akiyo Nadamoto
Konan University, Kobe, Japan
3 shared publications Ryo Mashimo
Nara Inst Sci & Technol, Grad Sch Informat Sci, 8916-5 Takayama, Ikoma, Nara 6580072, Japan
3 shared publications- Akiyo Nadamoto
Konan University
2 shared publications - Hideki Kawahara
Center for Innovative Research and Liaison, Wakayama University 5 , Wakayama
2 shared publications
Latest Publications
- 19 February 2026
- Published by Taylor & Francis
- p. 213-221
Articulatory disfluency in healthy individuals experiencing speech clumsiness
- 19 February 2026
- Published by Taylor & Francis
- p. 213-221
Articulatory disfluency in healthy individuals experiencing speech clumsiness
- 27 September 2025
- Published by Elsevier in Journal of Voice
Gamification of Tube Phonation: A Feasibility Study for Voice Therapy Practice
- 27 September 2025
- Published by Elsevier in Journal of Voice
Gamification of Tube Phonation: A Feasibility Study for Voice Therapy Practice
- Open Access
- 1 June 2025
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 5 (6)
Ultrasound measurement of relative tongue size and its correlation with tongue mobility for healthy individuals
The size of an individual's tongue relative to the oral cavity is associated with articulation speed [Feng, Lu, Zheng, Chi, and Honda, in Proceedings of the 10th Biennial Asia Pacific Conference on Speech, Language, and Hearing (2017), pp. 17–19)] and may affect speech clarity. This study introduces an ultrasound-based method for measuring relative tongue size, termed ultrasound-based relative tongue size (uRTS), as a cost-effective alternative to the magnetic resonance imaging (MRI) based method. Using deep learning to extract the tongue contour, uRTS was calculated from tongue and oropharyngeal cavity sizes in the midsagittal plane. Results from ten speakers showed a strong correlation between uRTS and MRI-based measurements (r = 0.87) and a negative correlation with tongue movement speed (r = −0.73), indicating uRTS is a useful index for assessing tongue size.
- 1 June 2025
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 5 (6)
Open AccessUltrasound measurement of relative tongue size and its correlation with tongue mobility for healthy individuals
The size of an individual's tongue relative to the oral cavity is associated with articulation speed [Feng, Lu, Zheng, Chi, and Honda, in Proceedings of the 10th Biennial Asia Pacific Conference on Speech, Language, and Hearing (2017), pp. 17–19)] and may affect speech clarity. This study introduces an ultrasound-based method for measuring relative tongue size, termed ultrasound-based relative tongue size (uRTS), as a cost-effective alternative to the magnetic resonance imaging (MRI) based method. Using deep learning to extract the tongue contour, uRTS was calculated from tongue and oropharyngeal cavity sizes in the midsagittal plane. Results from ten speakers showed a strong correlation between uRTS and MRI-based measurements (r = 0.87) and a negative correlation with tongue movement speed (r = −0.73), indicating uRTS is a useful index for assessing tongue size.
- Open Access
- 1 March 2025
- Published by Acoustical Society of Japan in Acoustical Science and Technology
- Vol. 46 (2) , 167-172
Kymograph-based indicator for assessing articulatory motion in repetitive speech production
This study aimed to develop an indicator for assessing articulatory motion during fast and repetitive syllable production, focusing on fluency, periodicity, and consistency. The method utilizes a kymograph derived from the ultrasound imaging of tongue movements in the midsagittal plane. The kymograph was generated by juxtaposing pixels along an observation line through the point of the greatest tongue movement. Periodic patterns in the kymograph indicate controlled, consistent tongue and mandibular movements, whereas nonperiodic patterns suggest speech disturbances. The method employs power spectral image, obtained through two-dimensional discrete Fourier transforms of the kymograph. The resulting power spectrum represents the periodic components in the horizontal direction of the kymograph, with prominent peaks indicating consistent patterns. To validate the method, the authors analyzed ultrasound movies of healthy Japanese speakers—-both fluent speakers and those who experienced a sense of speech clumsiness—-producing repetitive syllables (/aka/, /aga/, /ata/, and /ada/). The results demonstrated the effectiveness of the indicator in distinguishing between periodic and nonperiodic tongue motions. This approach shows promise for application to real-time MRI movies, potentially opening new avenues for the in-depth analysis of motor speech function. This indicator contributes to the assessment and quantification of the articulatory motion.
- 1 March 2025
- Published by Acoustical Society of Japan in Acoustical Science and Technology
- Vol. 46 (2) , 167-172
Open AccessKymograph-based indicator for assessing articulatory motion in repetitive speech production
This study aimed to develop an indicator for assessing articulatory motion during fast and repetitive syllable production, focusing on fluency, periodicity, and consistency. The method utilizes a kymograph derived from the ultrasound imaging of tongue movements in the midsagittal plane. The kymograph was generated by juxtaposing pixels along an observation line through the point of the greatest tongue movement. Periodic patterns in the kymograph indicate controlled, consistent tongue and mandibular movements, whereas nonperiodic patterns suggest speech disturbances. The method employs power spectral image, obtained through two-dimensional discrete Fourier transforms of the kymograph. The resulting power spectrum represents the periodic components in the horizontal direction of the kymograph, with prominent peaks indicating consistent patterns. To validate the method, the authors analyzed ultrasound movies of healthy Japanese speakers—-both fluent speakers and those who experienced a sense of speech clumsiness—-producing repetitive syllables (/aka/, /aga/, /ata/, and /ada/). The results demonstrated the effectiveness of the indicator in distinguishing between periodic and nonperiodic tongue motions. This approach shows promise for application to real-time MRI movies, potentially opening new avenues for the in-depth analysis of motor speech function. This indicator contributes to the assessment and quantification of the articulatory motion.
- 23 January 2025
- Published by Springer Nature
- p. 187-202
Comparative Analysis with Multiple Large-Scale Language Models for Automatic Generation of Funny Dialogues
- 23 January 2025
- Published by Springer Nature
- p. 187-202
Comparative Analysis with Multiple Large-Scale Language Models for Automatic Generation of Funny Dialogues
- Open Access
- 1 January 2024
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 4 (1)
Mapping palatal shape to electromagnetic articulography data: An approach using 3D scanning and sensor matching
A method for superimposing the shape of the palate on three-dimensional (3D) electromagnetic articulography (EMA) data is proposed. A biteplate with a dental impression tray and EMA sensors is used to obtain the palatal shape and record the sensor positions. The biteplate is then 3D scanned, and the scanned palate is mapped to the EMA data by matching the sensor positions on the scanned image with those in the EMA readings. The average distance between the mapped palate and the EMA palate traces is roughly 1 mm for nine speakers and is comparable to the measurement error of the EMA.
- 1 January 2024
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 4 (1)
Open AccessMapping palatal shape to electromagnetic articulography data: An approach using 3D scanning and sensor matching
A method for superimposing the shape of the palate on three-dimensional (3D) electromagnetic articulography (EMA) data is proposed. A biteplate with a dental impression tray and EMA sensors is used to obtain the palatal shape and record the sensor positions. The biteplate is then 3D scanned, and the scanned palate is mapped to the EMA data by matching the sensor positions on the scanned image with those in the EMA readings. The average distance between the mapped palate and the EMA palate traces is roughly 1 mm for nine speakers and is comparable to the measurement error of the EMA.
- 16 September 2023
- Published by Elsevier in Journal of Voice
- Vol. 40 (1) , 251.e17-251.e21
Effects of Increased Nasal Volume due to Topical Adrenaline on the Voice
- 16 September 2023
- Published by Elsevier in Journal of Voice
- Vol. 40 (1) , 251.e17-251.e21
Effects of Increased Nasal Volume due to Topical Adrenaline on the Voice
- Open Access
- 1 September 2023
- Published by Acoustical Society of Japan in Acoustical Science and Technology
- Vol. 44 (5) , 407-410
Vocal tract configuration during imitating voices: A case study for a professional impersonator
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 1 September 2023
- Published by Acoustical Society of Japan in Acoustical Science and Technology
- Vol. 44 (5) , 407-410
Open AccessVocal tract configuration during imitating voices: A case study for a professional impersonator
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- Open Access
An objective test tool for pitch extractors' response attributes
We propose an objective measurement method for pitch extractors' responses to frequency-modulated signals. It enables us to evaluate different pitch extractors with unified criteria. The method uses extended time-stretched pulses combined by binary orthogonal sequences. It provides simultaneous measurement results consisting of the linear and the non-linear time-invariant responses and random and time-varying responses. We tested representative pitch extractors using fundamental frequencies spanning 80~Hz to 800~Hz with 1/48 octave steps and produced more than 2000 modulation frequency response plots. We found that making scientific visualization by animating these plots enables us to understand different pitch extractors' behavior at once. Such efficient and effortless inspection is impossible by inspecting all individual plots. The proposed measurement method with visualization leads to further improvement of the performance of one of the extractors mentioned above. In other words, our procedure turns the specific pitch extractor into the best reliable measuring equipment that is crucial for scientific research. We open-sourced MATLAB codes of the proposed objective measurement method and visualization procedure.
Open AccessAn objective test tool for pitch extractors' response attributes
We propose an objective measurement method for pitch extractors' responses to frequency-modulated signals. It enables us to evaluate different pitch extractors with unified criteria. The method uses extended time-stretched pulses combined by binary orthogonal sequences. It provides simultaneous measurement results consisting of the linear and the non-linear time-invariant responses and random and time-varying responses. We tested representative pitch extractors using fundamental frequencies spanning 80~Hz to 800~Hz with 1/48 octave steps and produced more than 2000 modulation frequency response plots. We found that making scientific visualization by animating these plots enables us to understand different pitch extractors' behavior at once. Such efficient and effortless inspection is impossible by inspecting all individual plots. The proposed measurement method with visualization leads to further improvement of the performance of one of the extractors mentioned above. In other words, our procedure turns the specific pitch extractor into the best reliable measuring equipment that is crucial for scientific research. We open-sourced MATLAB codes of the proposed objective measurement method and visualization procedure.
- Open Access
Measuring pitch extractors' response to frequency-modulated multi-component signals
This article focuses on the research tool for investigating the fundamental frequencies of voiced sounds. We introduce an objective and informative measurement method of pitch extractors' response to frequency-modulated tones. The method uses a new test signal for acoustic system analysis. The test signal enables simultaneous measurement of the extractors' responses. They are the modulation frequency response and the total distortion, including intermodulation distortions. We applied this method to various pitch extractors and placed them on several performance maps. We used the proposed method to fine-tune one of the extractors to make it the best fit tool for scientific research of voice fundamental frequencies.
Open AccessMeasuring pitch extractors' response to frequency-modulated multi-component signals
This article focuses on the research tool for investigating the fundamental frequencies of voiced sounds. We introduce an objective and informative measurement method of pitch extractors' response to frequency-modulated tones. The method uses a new test signal for acoustic system analysis. The test signal enables simultaneous measurement of the extractors' responses. They are the modulation frequency response and the total distortion, including intermodulation distortions. We applied this method to various pitch extractors and placed them on several performance maps. We used the proposed method to fine-tune one of the extractors to make it the best fit tool for scientific research of voice fundamental frequencies.