Nicholas Bell‐Allen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nicholas Bell‐Allen has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Jaswinder S. Samra
Department of Upper Gastrointestinal Surgery Royal North Shore Hospital St Leonards New South Wales Australia
3 shared publications Lucian Roseverne
2 shared publicationsNicholas O'ROurke
Department of HPB Surgery Royal Brisbane & Women's Hospital Herston Brisbane Australia
2 shared publications- Adam McNamara
Cairns and Hinterland Hospital and Health Service Cairns Australia
1 shared publication Anubhav Mittal
1 shared publication- Anubhav Mittal
Department of Upper Gastrointestinal Surgery Royal North Shore Hospital St Leonards New South Wales Australia
1 shared publication
Latest Publications
- 8 April 2026
- Published by Wiley in Anz Journal of Surgery
- Vol. 96 (7-8) , 2211-2213
How to Do a Laparoscopic Caudate Lobectomy (With Video)
This paper describes the surgical technique for a laparoscopic caudate lobectomy, offering a detailed educational demonstration of this complex procedure. Our contribution focuses on the clear visualisation of the intricate anatomical relationships with major vascular structures and outlines the key steps to approach this technically challenging operation safely.
- 8 April 2026
- Published by Wiley in Anz Journal of Surgery
- Vol. 96 (7-8) , 2211-2213
How to Do a Laparoscopic Caudate Lobectomy (With Video)
This paper describes the surgical technique for a laparoscopic caudate lobectomy, offering a detailed educational demonstration of this complex procedure. Our contribution focuses on the clear visualisation of the intricate anatomical relationships with major vascular structures and outlines the key steps to approach this technically challenging operation safely.
- 10 December 2025
- Published by Wiley in Anz Journal of Surgery
- Vol. 96 (6) , 1669-1677
Three‐Dimensional Reconstruction of Hepatic Imaging to Tailor Complex Liver Resection: A Preliminary Australian Single Centre Experience
Background: Safe hepatic resection relies on precise understanding of patient‐specific anatomy. This is challenging with conventional two‐dimensional imaging and can lead to unnecessarily large resections. While three‐dimensional (3D) reconstruction offers superior visualisation, its adoption has been limited by complex workflows. This study reports an initial experience of an Australian centre using the streamlined Fujifilm Synapse 3D system for planning complex liver resections. Methods: We prospectively evaluated five patients undergoing complex hepatic resection. Patient‐specific 3D models were generated from preoperative computed tomography/magnetic resonance imaging scans. Two hepatobiliary surgeons used these interactive models to assess tumour anatomy, simulate resections, and devise a consensus operative strategy. The primary aim was to assess the technology's feasibility and its influence on bespoke surgical plans, particularly the adoption of parenchyma‐sparing surgery (PSS). Results: The 3D models directly influenced the surgical plan in four of five cases. In two patients with multifocal metastases and borderline liver function, 3D planning enabled complex PSS that increased the future liver remnant by an estimated 30%, avoiding high‐risk hepatectomies. In two others with large hepatocellular carcinomas, the models facilitated super‐selective anatomical resections that maximised parenchymal preservation. Conclusion: Our initial experience demonstrates the Synapse Fujifilm 3D reconstruction system is a practical and clinically valuable tool. By providing intuitive, patient‐specific anatomical detail, it facilitates a shift towards complex PSS, refining surgical approaches, enhancing operative safety for patients with challenging hepatic malignancies.
- 10 December 2025
- Published by Wiley in Anz Journal of Surgery
- Vol. 96 (6) , 1669-1677
Three‐Dimensional Reconstruction of Hepatic Imaging to Tailor Complex Liver Resection: A Preliminary Australian Single Centre Experience
Background: Safe hepatic resection relies on precise understanding of patient‐specific anatomy. This is challenging with conventional two‐dimensional imaging and can lead to unnecessarily large resections. While three‐dimensional (3D) reconstruction offers superior visualisation, its adoption has been limited by complex workflows. This study reports an initial experience of an Australian centre using the streamlined Fujifilm Synapse 3D system for planning complex liver resections. Methods: We prospectively evaluated five patients undergoing complex hepatic resection. Patient‐specific 3D models were generated from preoperative computed tomography/magnetic resonance imaging scans. Two hepatobiliary surgeons used these interactive models to assess tumour anatomy, simulate resections, and devise a consensus operative strategy. The primary aim was to assess the technology's feasibility and its influence on bespoke surgical plans, particularly the adoption of parenchyma‐sparing surgery (PSS). Results: The 3D models directly influenced the surgical plan in four of five cases. In two patients with multifocal metastases and borderline liver function, 3D planning enabled complex PSS that increased the future liver remnant by an estimated 30%, avoiding high‐risk hepatectomies. In two others with large hepatocellular carcinomas, the models facilitated super‐selective anatomical resections that maximised parenchymal preservation. Conclusion: Our initial experience demonstrates the Synapse Fujifilm 3D reconstruction system is a practical and clinically valuable tool. By providing intuitive, patient‐specific anatomical detail, it facilitates a shift towards complex PSS, refining surgical approaches, enhancing operative safety for patients with challenging hepatic malignancies.
- 22 January 2024
- Published by Wiley in Anz Journal of Surgery
- Vol. 94 (5) , 876-880
Laparoscopic partial splenectomy in distal pancreatectomy may preserve splenic function
Introduction: Splenectomy is known to carry a risk of infection with encapsulated organisms and associated sepsis. Current Australian guidelines recommend intensive vaccination schedules and long‐term antibiotic therapy. We postulate that in some clinical scenarios where distal pancreatectomy (DP) and splenectomy is being performed, a partial splenectomy is feasible. This may preserve splenic function and help retain immunocompetence.Methods: Five patients underwent laparoscopic distal pancreatectomy with partial splenectomy (LDPPS). The DP is performed with proximal division and resection of the splenic artery and vein. The inferior portion of the spleen is removed en bloc with the distal pancreas with ligasure and linear cutting staplers. The line of demarcation on the spleen after the division of the splenic artery identifies the portion supplied by the short gastric vessels. Temporary clamping of the short gastrics during splenic parenchymal transection reduces blood loss. All operations were completed laparoscopically and within 4 h.Results: The pathology of resected lesions includes a serous cystadenoma, a pseudocyst, an IPMN and two small medial pancreatic ductal adenocarcinomas. The benign lesions involved splenic vessels at the hilum, making Kimura or Warshaw procedures untenable. No patient required blood transfusion. One patient suffered a postoperative collection consistent with postoperative pancreatic fistula requiring a drain for 10 days. Follow‐up ranged from 6 to 24 months. Following surgery, all patients had a perfused splenic remnant on imaging and benign blood films, which suggests retained splenic function.Conclusion: Preserving some spleen when performing distal pancreatectomy may provide long‐term benefits for patients.
- 22 January 2024
- Published by Wiley in Anz Journal of Surgery
- Vol. 94 (5) , 876-880
Laparoscopic partial splenectomy in distal pancreatectomy may preserve splenic function
Introduction: Splenectomy is known to carry a risk of infection with encapsulated organisms and associated sepsis. Current Australian guidelines recommend intensive vaccination schedules and long‐term antibiotic therapy. We postulate that in some clinical scenarios where distal pancreatectomy (DP) and splenectomy is being performed, a partial splenectomy is feasible. This may preserve splenic function and help retain immunocompetence.Methods: Five patients underwent laparoscopic distal pancreatectomy with partial splenectomy (LDPPS). The DP is performed with proximal division and resection of the splenic artery and vein. The inferior portion of the spleen is removed en bloc with the distal pancreas with ligasure and linear cutting staplers. The line of demarcation on the spleen after the division of the splenic artery identifies the portion supplied by the short gastric vessels. Temporary clamping of the short gastrics during splenic parenchymal transection reduces blood loss. All operations were completed laparoscopically and within 4 h.Results: The pathology of resected lesions includes a serous cystadenoma, a pseudocyst, an IPMN and two small medial pancreatic ductal adenocarcinomas. The benign lesions involved splenic vessels at the hilum, making Kimura or Warshaw procedures untenable. No patient required blood transfusion. One patient suffered a postoperative collection consistent with postoperative pancreatic fistula requiring a drain for 10 days. Follow‐up ranged from 6 to 24 months. Following surgery, all patients had a perfused splenic remnant on imaging and benign blood films, which suggests retained splenic function.Conclusion: Preserving some spleen when performing distal pancreatectomy may provide long‐term benefits for patients.
- 5 October 2023
- Published by Wiley in Anz Journal of Surgery
- Vol. 93 (12) , 2897-2903
Robotic enucleation & uncinectomy of complex lesions of the proximal pancreas
BackgroundMalignant tumours within the proximal pancreas traditionally require pancreaticoduodenectomy (PD) for cure. For smaller lesions with borderline malignant potential the risk/benefit of PD becomes difficult to justify. Robotic approaches to these lesions allow for parenchymal preserving resection with reduced complication profile without oncological compromise.MethodsA review of a single surgeons prospectively collated database across two institutions of consecutive robotic enucleations or parenchyma preserving resections of the proximal pancreas was performed between July 2018 and October 2021. Standard demographic data, preoperative variables, intraoperative parameters, post-operative outcomes, morbidity and mortality were recorded.ResultsThirteen patients (8 female and 5 male) underwent robotic enucleation (EN) (8) and/or uncinectomy (UN) (5) in the proximal pancreas. Mean BMI was 32(kg/m2). Three patients (21%) underwent preoperative prophylactic pancreatic duct stenting. One patient required conversion to open. The median operative time in the EN group was 170 min (108-224 min) and the UN group was 160 min (110-204 min). The majority (8) of lesions were pNETs. Three lesions were IPMNs, with 1 solitary fibrous tumour and a serous cystic neoplasm (SCN) respectively. Median tumour size was 23 mm (11-58 mm) in the EN group, and 27 mm (17-38 mm) in the UN group. Ten of 13 patients had an R0 resection. There was no mortality in our series. Four (31%) patients across both groups developed clinically relevant POPF while none developed new endocrine or exocrine insufficiency. Average outpatient follow-up has been 6 months (1-18 months).ConclusionA robotic approach in proximal parenchymal preserving pancreatectomy is expanding, safe and feasible. Minimally invasive uncinectomy and enucleation of borderline malignant lesions of the proximal pancreas has become possible with the use of the robotic platform. With careful case selection, this allows a parenchymal preserving option to lesions traditionally necessitating morbid pancreaticoduodenectomy. We have proven that this is a developing, safe and effective technique.image
- 5 October 2023
- Published by Wiley in Anz Journal of Surgery
- Vol. 93 (12) , 2897-2903
Robotic enucleation & uncinectomy of complex lesions of the proximal pancreas
BackgroundMalignant tumours within the proximal pancreas traditionally require pancreaticoduodenectomy (PD) for cure. For smaller lesions with borderline malignant potential the risk/benefit of PD becomes difficult to justify. Robotic approaches to these lesions allow for parenchymal preserving resection with reduced complication profile without oncological compromise.MethodsA review of a single surgeons prospectively collated database across two institutions of consecutive robotic enucleations or parenchyma preserving resections of the proximal pancreas was performed between July 2018 and October 2021. Standard demographic data, preoperative variables, intraoperative parameters, post-operative outcomes, morbidity and mortality were recorded.ResultsThirteen patients (8 female and 5 male) underwent robotic enucleation (EN) (8) and/or uncinectomy (UN) (5) in the proximal pancreas. Mean BMI was 32(kg/m2). Three patients (21%) underwent preoperative prophylactic pancreatic duct stenting. One patient required conversion to open. The median operative time in the EN group was 170 min (108-224 min) and the UN group was 160 min (110-204 min). The majority (8) of lesions were pNETs. Three lesions were IPMNs, with 1 solitary fibrous tumour and a serous cystic neoplasm (SCN) respectively. Median tumour size was 23 mm (11-58 mm) in the EN group, and 27 mm (17-38 mm) in the UN group. Ten of 13 patients had an R0 resection. There was no mortality in our series. Four (31%) patients across both groups developed clinically relevant POPF while none developed new endocrine or exocrine insufficiency. Average outpatient follow-up has been 6 months (1-18 months).ConclusionA robotic approach in proximal parenchymal preserving pancreatectomy is expanding, safe and feasible. Minimally invasive uncinectomy and enucleation of borderline malignant lesions of the proximal pancreas has become possible with the use of the robotic platform. With careful case selection, this allows a parenchymal preserving option to lesions traditionally necessitating morbid pancreaticoduodenectomy. We have proven that this is a developing, safe and effective technique.image
- Open Access
- 9 February 2022
- Published by Wiley in Anz Journal of Surgery
- Vol. 92 (10) , 2529-2533
Ventral hernia repair with a hybrid laparoscopic technique
Background: Ventral hernias are increasingly managed with minimally invasive laparoscopic surgery. Invasive open surgery is typically used for the repair of large‐sized hernias (>10 cm diameter). The two methods are often considered mutually exclusive. We report a hybrid technique for repair of medium to large‐sized hernias.Methods: Data was collected prospectively from 44 hernias repaired using the hybrid technique from 2012 to 2020. Operative data was examined and follow‐up conducted by both clinical and phone review. As for surgical technique, laparoscopic access was established via a 5 mm optical port and two (or more) 5 mm ports were added under vision. Hernia contents were reduced and extraperitoneal fat excised around the defect. Hernias with diameters ranging from 5 to 10 cm were fixed using the hybrid technique. A small incision was made directly over the hernia and polyester mesh was placed intraabdominally before defect closure with a transfascial suture. Pneumoperitoneum was re‐established and mesh fixation achieved using absorbable tacks and/or fixation sutures.Results: Of the 44 ventral hernias repaired with the hybrid technique, 43 were secondary hernias from incisional defects. Average hernia diameter was 6.6 cm. 86% of patients were discharged within the first 48 h. Four patients (9%) had recurrences during the study period. Minor complications occurred in 8 patients (18%): 3 (7%) had post‐operative wound infection, 3 patients (7%) developed post‐operative seroma. Two patients (5%) had clinically significant wound haematoma.Conclusion: Laparoscopic hybrid ventral hernia repair can be safely performed by a combination of laparoscopic and open techniques, offering an alternative method in the management of medium‐sized ventral hernias.
- 9 February 2022
- Published by Wiley in Anz Journal of Surgery
- Vol. 92 (10) , 2529-2533
Open AccessVentral hernia repair with a hybrid laparoscopic technique
Background: Ventral hernias are increasingly managed with minimally invasive laparoscopic surgery. Invasive open surgery is typically used for the repair of large‐sized hernias (>10 cm diameter). The two methods are often considered mutually exclusive. We report a hybrid technique for repair of medium to large‐sized hernias.Methods: Data was collected prospectively from 44 hernias repaired using the hybrid technique from 2012 to 2020. Operative data was examined and follow‐up conducted by both clinical and phone review. As for surgical technique, laparoscopic access was established via a 5 mm optical port and two (or more) 5 mm ports were added under vision. Hernia contents were reduced and extraperitoneal fat excised around the defect. Hernias with diameters ranging from 5 to 10 cm were fixed using the hybrid technique. A small incision was made directly over the hernia and polyester mesh was placed intraabdominally before defect closure with a transfascial suture. Pneumoperitoneum was re‐established and mesh fixation achieved using absorbable tacks and/or fixation sutures.Results: Of the 44 ventral hernias repaired with the hybrid technique, 43 were secondary hernias from incisional defects. Average hernia diameter was 6.6 cm. 86% of patients were discharged within the first 48 h. Four patients (9%) had recurrences during the study period. Minor complications occurred in 8 patients (18%): 3 (7%) had post‐operative wound infection, 3 patients (7%) developed post‐operative seroma. Two patients (5%) had clinically significant wound haematoma.Conclusion: Laparoscopic hybrid ventral hernia repair can be safely performed by a combination of laparoscopic and open techniques, offering an alternative method in the management of medium‐sized ventral hernias.
- 12 October 2017
- Published by Wiley in Anz Journal of Surgery
- Vol. 88 (7-8) , 718-722
Laparoscopic ventral hernia repair using only 5‐mm ports
Background: The technique of laparoscopic ventral hernia repair has been evolving since it was first described over 20 years ago. We report a new technique where polyester mesh was back loaded through a 5‐mm port site, coming into contact with the skin. This avoids the need for any 10–12‐mm ports.Methods: A prospective database of laparoscopic ventral hernia repairs was examined. A single surgeon performed 344 laparoscopic ventral hernia repairs using this technique over 60 months. Follow‐up was conducted by both clinical and independent phone review. Surgical technique: Laparoscopic access was achieved via a 5‐mm optical port, adding two, or occasionally three, 5‐mm extra ports. Hernia contents were reduced and the extra‐peritoneal fat excised; 5‐mm tooth graspers were placed through the lateral port and then in a retrograde fashion through the uppermost port. The port was removed, and the mesh pulled back into the abdominal cavity and positioned with a minimum of 3‐cm overlap. The mesh was fixed using absorbable tacks and sutures.Results: Most patients had primary umbilical hernias. There was one case of mesh infection due to enteric organisms. This occurred in a patient undergoing repair of a stoma site hernia, resulting from a Hartmann's procedure for perforated diverticulitis. There was no other evidence of acute or chronic mesh infection despite cutaneous contact with the mesh. In this series, there was an overall hernia recurrence rate of 2.4%.Conclusion: Laparoscopic ventral hernia repair using only 5‐mm ports is a safe, effective technique with no extra risk of infection.
- 12 October 2017
- Published by Wiley in Anz Journal of Surgery
- Vol. 88 (7-8) , 718-722
Laparoscopic ventral hernia repair using only 5‐mm ports
Background: The technique of laparoscopic ventral hernia repair has been evolving since it was first described over 20 years ago. We report a new technique where polyester mesh was back loaded through a 5‐mm port site, coming into contact with the skin. This avoids the need for any 10–12‐mm ports.Methods: A prospective database of laparoscopic ventral hernia repairs was examined. A single surgeon performed 344 laparoscopic ventral hernia repairs using this technique over 60 months. Follow‐up was conducted by both clinical and independent phone review. Surgical technique: Laparoscopic access was achieved via a 5‐mm optical port, adding two, or occasionally three, 5‐mm extra ports. Hernia contents were reduced and the extra‐peritoneal fat excised; 5‐mm tooth graspers were placed through the lateral port and then in a retrograde fashion through the uppermost port. The port was removed, and the mesh pulled back into the abdominal cavity and positioned with a minimum of 3‐cm overlap. The mesh was fixed using absorbable tacks and sutures.Results: Most patients had primary umbilical hernias. There was one case of mesh infection due to enteric organisms. This occurred in a patient undergoing repair of a stoma site hernia, resulting from a Hartmann's procedure for perforated diverticulitis. There was no other evidence of acute or chronic mesh infection despite cutaneous contact with the mesh. In this series, there was an overall hernia recurrence rate of 2.4%.Conclusion: Laparoscopic ventral hernia repair using only 5‐mm ports is a safe, effective technique with no extra risk of infection.