Rahul Radhakrishna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rahul Radhakrishna has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Joseph Jewell Pancrazio
The University of Texas at Dallas
4 shared publications - Brandon Scott Sturgill
Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA
3 shared publications - Sourav Sanchit Patnaik
Department of Anesthesiology and Pain Management, The University of Texas Southwestern Medical Center
3 shared publications - Stuart F. Cogan
Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA
3 shared publications - Ana G. Hernandez-Reynoso
Case Western Reserve University
2 shared publications - Jeffrey R. Capadona
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA
2 shared publications
Latest Publications
- Open Access
- 30 October 2026
- Published by IOP Publishing in Journal of Neural Engineering
Axonal spike-count regimes link spinal cord stimulation periodicity to artificial sensory detection and discrimination in rodents
Objective: Electrical stimulation is widely used to evoke artificial sensation, yet how temporal stimulation patterns are transformed into neural activity and perception remains poorly understood. Recent behavioral studies have shown that increasing the aperiodicity of spinal cord stimulation pulse trains alters both detection thresholds and discrimination performance despite constant pulse counts, suggesting a role for temporal structure beyond rate alone. However, the neural mechanisms underlying these effects remain unresolved. Approach: We coupled a finite-element spinal cord model to 420 conductance-based axons spanning 35 locations, six diameters, and two nodal phases. Nine index-axon spike-count regimes defined amplitudes applied to the entire population to produce heterogeneous recruitment and spike output. Population responses were used to investigate how stimulation periodicity shapes neural responses and resulting behavior. These regimes ranged from single spikes and small volleys to sustained spike trains, and they demonstrated stable operating ranges arising from interactions between stimulation timing and axonal membrane dynamics. Main results: No single regime sufficiently explained the experimentally observed detection threshold trends; instead, mixtures of regimes accurately reproduced frequency-dependent mean threshold behavior. Extending this framework to periodicity discrimination, rate and timing features derived from regime mixtures contained sufficient information to recover behavioral psychometric curves using constrained observer models. The per-frequency hybrid (rate + timing) model, with frequency-specific mixtures and block-specific decision parameters, had mean RMSE 0.0881, outperforming the individual rate (RMSE 0.1078) and timing (RMSE 0.0958) models in matching animal behavior. Model optimization (rate vs. timing) showed that discrimination from periodic stimuli incorporated greater rate information, while discrimination from aperiodic stimuli was more timing information-dependent. Significance: These results establish a mechanistic link between stimulation temporal structure, axonal spike generation, and perceptual behavior. This framework suggests that spinal cord stimulation does not operate within a single fixed neural regime but instead engages a spectrum of spike-count regimes whose mixtures can shape perception. These findings have important implications for the design of biomimetic stimulation strategies, highlighting temporal patterning as a key dimension for controlling sensory outcomes.
- 30 October 2026
- Published by IOP Publishing in Journal of Neural Engineering
Open AccessAxonal spike-count regimes link spinal cord stimulation periodicity to artificial sensory detection and discrimination in rodents
Objective: Electrical stimulation is widely used to evoke artificial sensation, yet how temporal stimulation patterns are transformed into neural activity and perception remains poorly understood. Recent behavioral studies have shown that increasing the aperiodicity of spinal cord stimulation pulse trains alters both detection thresholds and discrimination performance despite constant pulse counts, suggesting a role for temporal structure beyond rate alone. However, the neural mechanisms underlying these effects remain unresolved. Approach: We coupled a finite-element spinal cord model to 420 conductance-based axons spanning 35 locations, six diameters, and two nodal phases. Nine index-axon spike-count regimes defined amplitudes applied to the entire population to produce heterogeneous recruitment and spike output. Population responses were used to investigate how stimulation periodicity shapes neural responses and resulting behavior. These regimes ranged from single spikes and small volleys to sustained spike trains, and they demonstrated stable operating ranges arising from interactions between stimulation timing and axonal membrane dynamics. Main results: No single regime sufficiently explained the experimentally observed detection threshold trends; instead, mixtures of regimes accurately reproduced frequency-dependent mean threshold behavior. Extending this framework to periodicity discrimination, rate and timing features derived from regime mixtures contained sufficient information to recover behavioral psychometric curves using constrained observer models. The per-frequency hybrid (rate + timing) model, with frequency-specific mixtures and block-specific decision parameters, had mean RMSE 0.0881, outperforming the individual rate (RMSE 0.1078) and timing (RMSE 0.0958) models in matching animal behavior. Model optimization (rate vs. timing) showed that discrimination from periodic stimuli incorporated greater rate information, while discrimination from aperiodic stimuli was more timing information-dependent. Significance: These results establish a mechanistic link between stimulation temporal structure, axonal spike generation, and perceptual behavior. This framework suggests that spinal cord stimulation does not operate within a single fixed neural regime but instead engages a spectrum of spike-count regimes whose mixtures can shape perception. These findings have important implications for the design of biomimetic stimulation strategies, highlighting temporal patterning as a key dimension for controlling sensory outcomes.
- 21 March 2024
- Published by Elsevier in Biomaterials
- Vol. 308, 122543
Planar amorphous silicon carbide microelectrode arrays for chronic recording in rat motor cortex
- 21 March 2024
- Published by Elsevier in Biomaterials
- Vol. 308, 122543
Planar amorphous silicon carbide microelectrode arrays for chronic recording in rat motor cortex
- Open Access
- 1 November 2023
- Published by Elsevier in Biomaterials
- Vol. 303, 122351
The effect of a Mn(III)tetrakis(4-benzoic acid)porphyrin (MnTBAP) coating on the chronic recording performance of planar silicon intracortical microelectrode arrays
- 1 November 2023
- Published by Elsevier in Biomaterials
- Vol. 303, 122351
Open AccessThe effect of a Mn(III)tetrakis(4-benzoic acid)porphyrin (MnTBAP) coating on the chronic recording performance of planar silicon intracortical microelectrode arrays
- Open Access
- 20 March 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (3) , 480
Characterization of Active Electrode Yield for Intracortical Arrays: Awake versus Anesthesia
Intracortical microelectrode arrays are used for recording neural signals at single-unit resolution and are promising tools for studying brain function and developing neuroprosthetics. Research is being done to increase the chronic performance and reliability of these probes, which tend to decrease or fail within several months of implantation. Although recording paradigms vary, studies focused on assessing the reliability and performance of these devices often perform recordings under anesthesia. However, anesthetics—such as isoflurane—are known to alter neural activity and electrophysiologic function. Therefore, we compared the neural recording performance under anesthesia (2% isoflurane) followed by awake conditions for probes implanted in the motor cortex of both male and female Sprague-Dawley rats. While the single-unit spike rate was significantly higher by almost 600% under awake compared to anesthetized conditions, we found no difference in the active electrode yield between the two conditions two weeks after surgery. Additionally, the signal-to-noise ratio was greater under anesthesia due to the noise levels being nearly 50% greater in awake recordings, even though there was a 14% increase in the peak-to-peak voltage of distinguished single units when awake. We observe that these findings are similar for chronic time points as well. Our observations indicate that either anesthetized or awake recordings are acceptable for studies assessing the chronic reliability and performance of intracortical microelectrode arrays.
- 20 March 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (3) , 480
Open AccessCharacterization of Active Electrode Yield for Intracortical Arrays: Awake versus Anesthesia
Intracortical microelectrode arrays are used for recording neural signals at single-unit resolution and are promising tools for studying brain function and developing neuroprosthetics. Research is being done to increase the chronic performance and reliability of these probes, which tend to decrease or fail within several months of implantation. Although recording paradigms vary, studies focused on assessing the reliability and performance of these devices often perform recordings under anesthesia. However, anesthetics—such as isoflurane—are known to alter neural activity and electrophysiologic function. Therefore, we compared the neural recording performance under anesthesia (2% isoflurane) followed by awake conditions for probes implanted in the motor cortex of both male and female Sprague-Dawley rats. While the single-unit spike rate was significantly higher by almost 600% under awake compared to anesthetized conditions, we found no difference in the active electrode yield between the two conditions two weeks after surgery. Additionally, the signal-to-noise ratio was greater under anesthesia due to the noise levels being nearly 50% greater in awake recordings, even though there was a 14% increase in the peak-to-peak voltage of distinguished single units when awake. We observe that these findings are similar for chronic time points as well. Our observations indicate that either anesthetized or awake recordings are acceptable for studies assessing the chronic reliability and performance of intracortical microelectrode arrays.
- Open Access
- 27 September 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1158
Influence of Implantation Depth on the Performance of Intracortical Probe Recording Sites
Microelectrode arrays (MEAs) enable the recording of electrical activity from cortical neurons which has implications for basic neuroscience and neuroprosthetic applications. The design space for MEA technology is extremely wide where devices may vary with respect to the number of monolithic shanks as well as placement of microelectrode sites. In the present study, we examine the differences in recording ability between two different MEA configurations: single shank (SS) and multi-shank (MS), both of which consist of 16 recording sites implanted in the rat motor cortex. We observed a significant difference in the proportion of active microelectrode sites over the 8-week indwelling period, in which SS devices exhibited a consistent ability to record activity, in contrast to the MS arrays which showed a marked decrease in activity within 2 weeks post-implantation. Furthermore, this difference was revealed to be dependent on the depth at which the microelectrode sites were located and may be mediated by anatomical heterogeneity, as well as the distribution of inhibitory neurons within the cortical layers. Our results indicate that the implantation depth of microelectrodes within the cortex needs to be considered relative to the chronic performance characterization.
- 27 September 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1158
Open AccessInfluence of Implantation Depth on the Performance of Intracortical Probe Recording Sites
Microelectrode arrays (MEAs) enable the recording of electrical activity from cortical neurons which has implications for basic neuroscience and neuroprosthetic applications. The design space for MEA technology is extremely wide where devices may vary with respect to the number of monolithic shanks as well as placement of microelectrode sites. In the present study, we examine the differences in recording ability between two different MEA configurations: single shank (SS) and multi-shank (MS), both of which consist of 16 recording sites implanted in the rat motor cortex. We observed a significant difference in the proportion of active microelectrode sites over the 8-week indwelling period, in which SS devices exhibited a consistent ability to record activity, in contrast to the MS arrays which showed a marked decrease in activity within 2 weeks post-implantation. Furthermore, this difference was revealed to be dependent on the depth at which the microelectrode sites were located and may be mediated by anatomical heterogeneity, as well as the distribution of inhibitory neurons within the cortical layers. Our results indicate that the implantation depth of microelectrodes within the cortex needs to be considered relative to the chronic performance characterization.