Chengfeng Yin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chengfeng Yin has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Yujun Guo
School of Electrical Engineering Southwest Jiaotong University Chengdu China
2 shared publications - Bing Luo
School of Computer and Software Engineering, Xihua University, Chengdu, China
1 shared publication Chaoqun Shi
School of Electrical Engineering Southwest Jiaotong University Chengdu China
1 shared publicationGuangning Wu
School of Electrical Engineering Southwest Jiaotong University Chengdu China
1 shared publication- Guangning Wu
Southwest Jiaotong University
1 shared publication - Guizao Huang
Southwest Jiaotong University
1 shared publication
Latest Publications
- 21 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
A Novel Method for Visualizing the Pollution Distribution of Insulators
Knowing more about insulator pollution is of guiding significance to the development of anti-pollution strategies. Traditional methods can be used to determine only the pollution degree of insulators. However, the pollution distribution also has a substantial influence on the flashover voltage of insulators even under the same equivalent salt deposit densities (ESDD). In this article, an ESDD spectral density method and a visualization method based on hyperspectral technology are proposed. The proposed method presents the ESDD distribution using hyperspectral images. A detection model based on characteristic wavelengths is established with partial least squares regression to detect the insulator ESDDs. Based on the ESDD detection results, the features of the ESDD spectral density process, including the building of the ESDD probability graph, the overall ESDD, and visualization of the ESDD, are presented. Example analyses of field-operating insulators were conducted, revealing that the ESDD spectral density can be used to track the pollution distribution of insulators and that the pollution degree can be calculated from the overall ESDD. The error of the overall ESDD calculated by this method is within 10%. In addition, visualization of the pollution distribution can more intuitively record the degree of pollution and the nonuniform distribution characteristics. Both the pollution degree and distribution can be obtained by this method. Therefore, hyperspectral technology can overcome the limitations of traditional methods and convert the ESDD results into an image to determine the ESDD distribution. These research results provide theoretical instruction for guiding insulation design and anti-pollution strategies for operating transmission lines.
- 21 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
A Novel Method for Visualizing the Pollution Distribution of Insulators
Knowing more about insulator pollution is of guiding significance to the development of anti-pollution strategies. Traditional methods can be used to determine only the pollution degree of insulators. However, the pollution distribution also has a substantial influence on the flashover voltage of insulators even under the same equivalent salt deposit densities (ESDD). In this article, an ESDD spectral density method and a visualization method based on hyperspectral technology are proposed. The proposed method presents the ESDD distribution using hyperspectral images. A detection model based on characteristic wavelengths is established with partial least squares regression to detect the insulator ESDDs. Based on the ESDD detection results, the features of the ESDD spectral density process, including the building of the ESDD probability graph, the overall ESDD, and visualization of the ESDD, are presented. Example analyses of field-operating insulators were conducted, revealing that the ESDD spectral density can be used to track the pollution distribution of insulators and that the pollution degree can be calculated from the overall ESDD. The error of the overall ESDD calculated by this method is within 10%. In addition, visualization of the pollution distribution can more intuitively record the degree of pollution and the nonuniform distribution characteristics. Both the pollution degree and distribution can be obtained by this method. Therefore, hyperspectral technology can overcome the limitations of traditional methods and convert the ESDD results into an image to determine the ESDD distribution. These research results provide theoretical instruction for guiding insulation design and anti-pollution strategies for operating transmission lines.
- 11 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Method for detection the non-soluble deposit density of insulators based on hyperspectral technology
The rapid development of agriculture and industry in China leads to a fast increase in the non-soluble deposit density (NSDD) of insulators. At present, the detection of NSDD is concentrated in the use of optical principles, which is difficult to achieve quantitative detection. Hyperspectral technique is a new comprehensive image data technique based on imaging spectroscopy, which has the advantages of multi-band, high resolution. Therefore, a non-contact detection method for detecting NSDD based on hyperspectral technique is proposed. The hyperspectral images of the insulator were obtained and preprocessed with black-and-white correction, which were used to establish the model based on the extreme learning machine with the kernel (KELM). Finally, the detection of NSDD was realized. Consequently, this study can guide the prevention of flash and configuration of external insulation in transmission lines.
- 11 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Method for detection the non-soluble deposit density of insulators based on hyperspectral technology
The rapid development of agriculture and industry in China leads to a fast increase in the non-soluble deposit density (NSDD) of insulators. At present, the detection of NSDD is concentrated in the use of optical principles, which is difficult to achieve quantitative detection. Hyperspectral technique is a new comprehensive image data technique based on imaging spectroscopy, which has the advantages of multi-band, high resolution. Therefore, a non-contact detection method for detecting NSDD based on hyperspectral technique is proposed. The hyperspectral images of the insulator were obtained and preprocessed with black-and-white correction, which were used to establish the model based on the extreme learning machine with the kernel (KELM). Finally, the detection of NSDD was realized. Consequently, this study can guide the prevention of flash and configuration of external insulation in transmission lines.
- Open Access
- 3 March 2021
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 6 (6) , 1031-1039
Method for detecting the pollution degree of naturally contaminated insulator based on hyperspectral characteristics
Insulator pollution degree detection is of great significance for preventing a flashover. Equivalent salt deposit density, leakage current, and surface pollution layer conductivity are commonly used to describe insulator pollution degree; however, all these parameters have limitations in field application and real‐time monitoring. Non‐contact detection methods, such as infrared thermal imaging and ultraviolet imaging, only image insulators in a specific band, which makes the extracted features limited. Hyperspectral technology is the new comprehensive image data technology based on imaging spectroscopy that has the advantages of multiband high resolution. Therefore, a method based on hyperspectral image and spectral characteristics is proposed to fully characterize natural pollution information and accurately detect the pollution degree of insulators. The hyperspectral spectral line characteristics, image texture, and colour characteristic data of insulators were extracted and fused and then used to establish the pollution degree detection model on the basis of integrated learning classification algorithms. The results show that the model based on fusion data has an accuracy rate of 95.0%, which is more accurate than the model based on spectral line features only. Consequently, hyperspectral technology can realize the non‐contact detection of pollution degree and provide some guidance for cleaning the contamination of external insulation.
- 3 March 2021
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 6 (6) , 1031-1039
Open AccessMethod for detecting the pollution degree of naturally contaminated insulator based on hyperspectral characteristics
Insulator pollution degree detection is of great significance for preventing a flashover. Equivalent salt deposit density, leakage current, and surface pollution layer conductivity are commonly used to describe insulator pollution degree; however, all these parameters have limitations in field application and real‐time monitoring. Non‐contact detection methods, such as infrared thermal imaging and ultraviolet imaging, only image insulators in a specific band, which makes the extracted features limited. Hyperspectral technology is the new comprehensive image data technology based on imaging spectroscopy that has the advantages of multiband high resolution. Therefore, a method based on hyperspectral image and spectral characteristics is proposed to fully characterize natural pollution information and accurately detect the pollution degree of insulators. The hyperspectral spectral line characteristics, image texture, and colour characteristic data of insulators were extracted and fused and then used to establish the pollution degree detection model on the basis of integrated learning classification algorithms. The results show that the model based on fusion data has an accuracy rate of 95.0%, which is more accurate than the model based on spectral line features only. Consequently, hyperspectral technology can realize the non‐contact detection of pollution degree and provide some guidance for cleaning the contamination of external insulation.