WLWei Luo

Wei Luo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wei Luo has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Lei Chen

    Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei 230031, China

    2 shared publications
  • Rujing Wang

    Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

    2 shared publications
  • Zelin Hu

    Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei 230031, China

    2 shared publications
  • Fenglong Sun

    Institute of Intelligent Machines Chinese Academy of Sciences 230031 Hefei China

    1 shared publication
  • Hairong Li

    Nanjing Tech University, Nanjing 211816, China

    1 shared publication
  • He Huang

    Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei 230031, PR China

    1 shared publication

Latest Publications

  • Open Access

    A Novel Dual-Wavelength Method for Evaluating Temperature Effect in Fiber-Optic SPR Sensors

    by Ning Su, Wei Luo, Liusan Wang, Zhengyong Zhang, Rujing Wang

    The temperature effect is one of the critical factors to induce the resonance wavelength shift in fiber-optic surface plasmon resonance (SPR) sensors, which leads to the inaccuracy measurement of refractive index (RI) in practical applications. In this study, a novel dual-wavelength method is presented for fiber-optic SPR sensors to measure the changes of RI and temperature simultaneously in real time. A typical model of an SPR-based fiber optical sensor is constructed for theoretical analysis of temperature effect. Both the thermo-optic effect in the fiber core and phonon–electron scattering along with electron–electron scattering in the metal layer are studied systematically in the theoretical model. The linear and independent relationship, about the dependence of defined output signals on the RI and temperature, is validated by a theoretical calculation in specific dual wavelengths. A proof-of-concept experiment is conducted to demonstrate the capability of the presented dual-wavelength technique. The experimental results indicate that the presented dual-wavelength method is technically feasible and can be applied for practical application. Since the presented method only depends on the full advantages of the transfer spectrum data, it can be applied directly to the conventional single-channel fiber-optic SPR without any specific design structure of the sensor probe. The proposed method provides a new way to detect the RI under different thermal conditions and could lead to a better design for the fiber-optic SPR sensors.


  • Open Access

    Simultaneous measurement of refractive index and temperature for prism-based surface plasmon resonance sensors

    by Wei Luo, Rujing Wang, Hairong Li, Jieting Kou, Xinhua Zeng, He Huang, Xiaobo Hu, Wei Huang

    A detailed theoretical model is provided to analyze the effects of temperature on prism-based surface plasmon resonance (SPR) sensors, including temperature dependence of the metal and prism. A complete sensitivity matrix simultaneously measures variations in refractive index (RI) and temperatures using measurements at two wavelengths for the angular-interrogation mode, or at two angles of incidence for the wavelength-interrogation mode. Correction of matrix coefficients improves accuracy of the two modes. Validation is performed using a self-designed wavelength SPR system with an adjustable incident angle perform. This method provides a new way to detect the RI and may lead to the better design and fabrication of prism-based SPR sensors.


  • Open Access

    Dual-angle technique for simultaneous measurement of refractive index and temperature based on a surface plasmon resonance sensor

    by Wei Luo, Sheng Chen, Lei Chen, Hualong Li, Pengcheng Miao, Huiyi Gao, Zelin Hu, Miao Li

    We describe a theoretical model to analyze temperature effects on the Kretschmann surface plasmon resonance (SPR) sensor, and describe a new double-incident angle technique to simultaneously measure changes in refractive index (RI) and temperature. The method uses the observation that output signals obtained from two different incident angles each have a linear dependence on RI and temperature, and are independent. A proof-of-concept experiment using different NaCl concentration solutions as analytes demonstrates the ability of the technique. The optical design is as simple and robust as conventional SPR detection, but provides a way to discriminate between RI-induced and temperature-induced SPR changes. This technique facilitates a way for traditional SPR sensors to detect RI in different temperature environments, and may lead to better design and fabrication of SPR sensors against temperature variation.


  • Open Access

    Double-incident Angle Method for the Improvement of Angle Scan Surface Plasmon Resonance Sensor

    by Wei Luo, Zelin Hu, Jiarui Liu, Fenglong Sun, Hualong Li, Lei Chen, Huiyi Gao, Miao Li